Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2021-32948 (GCVE-0-2021-32948)
Vulnerability from cvelistv5
- CWE-787 - OUT-OF-BOUNDS WRITE
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Drawings SDK |
Version: All versions prior to 2022.4 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:33:56.055Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf" }, { "tags": [ "x_transferred" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-984/" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Drawings SDK", "vendor": "n/a", "versions": [ { "status": "affected", "version": "All versions prior to 2022.4" } ] } ], "descriptions": [ { "lang": "en", "value": "An out-of-bounds write issue exists in the DWG file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "OUT-OF-BOUNDS WRITE CWE-787", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-14T00:00:00", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf" }, { "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-984/" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-32948", "datePublished": "2021-06-17T00:00:00", "dateReserved": "2021-05-13T00:00:00", "dateUpdated": "2024-08-03T23:33:56.055Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-32948\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2021-06-17T13:15:08.167\",\"lastModified\":\"2024-11-21T06:07:59.170\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An out-of-bounds write issue exists in the DWG file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.\"},{\"lang\":\"es\",\"value\":\"Se presenta un problema de escritura fuera de l\u00edmites en el procedimiento de lectura de archivos DWG en Drawings SDK (todas las versiones anteriores a 2022.4) resultando en una falta de comprobaci\u00f3n apropiada de los datos suministrados por el usuario. Esto puede resultar en una escritura m\u00e1s all\u00e1 del final de un b\u00fafer asignado y permitir a atacantes causar una condici\u00f3n de denegaci\u00f3n de servicio o ejecutar c\u00f3digo en el contexto del proceso actual\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:opendesign:drawings_sdk:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2022.4\",\"matchCriteriaId\":\"FEFEE0EB-BDA4-4D1A-85B5-0D0A80EE26FA\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:comos:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"10.4.1\",\"matchCriteriaId\":\"0F0CFB85-CD4F-424C-8B9F-9289D08FA665\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.2.0.1\",\"matchCriteriaId\":\"C811E8B2-CA0C-4A71-A803-A30C4DAF1476\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.2.0.1\",\"matchCriteriaId\":\"87BB2370-46C4-4BEC-8189-1F7FE4C1E12D\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-984/\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-984/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}" } }
ICSA-21-159-02
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Mat Powell", "Brian Gorenc" ], "organization": "Trend Micro\u0027s Zero Day Initiative", "summary": "reporting these vulnerabilities to CISA" }, { "organization": "Siemens ProductCERT", "summary": "assisting coordination with Open Design Alliance." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities may allow code execution in the context of the current process or cause a denial-of-service condition.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "United States", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Recommended Practices" } ], "publisher": { "category": "coordinator", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-21-159-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-159-02.json" }, { "category": "self", "summary": "ICSA Advisory ICSA-21-159-02 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-159-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014" } ], "title": "Open Design Alliance Drawings SDK", "tracking": { "current_release_date": "2021-06-08T06:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-159-02", "initial_release_date": "2021-06-08T06:00:00.000000Z", "revision_history": [ { "date": "2021-06-08T06:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Initial Publication" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c2022.4", "product": { "name": "Open Design Alliance Drawings SDK: \u003c2022.4", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Drawings SDK" }, { "branches": [ { "category": "product_version", "name": "2022.4", "product": { "name": "Open Design Alliance Drawings SDK: 2022.4", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Drawings SDK" } ], "category": "vendor", "name": "Open Design Alliance" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-32938", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected products are vulnerable to an out-of-bounds read due to parsing of DWG files resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of service condition or read sensitive information from memory.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32938" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0001" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-32936", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "An out-of-bounds write issue exists in the DXF file-recovering procedure resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32936" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0001" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-32940", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds read issue exists in the DWG file-recovering procedure resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or read sensitive information from memory locations.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32940" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0001" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-32946", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "An improper check for unusual or exceptional conditions issue exists within the parsing DGN files resulting from the lack of proper validation of the user-supplied data. This may result in several of out-of-bounds problems and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32946" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2021-32948", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "An out-of-bounds write issue exists in the DWG file-reading procedure resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32948" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0001" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-32950", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds read issue exists within the parsing of DXF files in the affected product resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of-service condition or read sensitive information from memory locations.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32950" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0001" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-32952", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "An out-of-bounds write issue exists in the DGN file-reading procedure in the affected product resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32952" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2021-32944", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free issue exists in the DGN file-reading procedure in the affected product resulting from the lack of proper validation of user-supplied data. This can result in a memory corruption or arbitrary code execution, allowing attackers to cause a denial-of-service condition or execute code in the context of the current process.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32944" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0001" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ] } ] }
icsa-21-222-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting this vulnerability to CISA." }, { "organization": "Trend Micro Zero Day Initiative", "summary": "coordinated disclosure" }, { "organization": "Open Design Alliance", "summary": "coordination efforts" }, { "names": [ "Kai Wang" ], "organization": "Codesafe Team of Legendsec at Qi\u0027anxin Group", "summary": "coordinated disclosure of CVE-2021-33717" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "Siemens has released version V13.2.0.1 for JT2Go and Teamcenter Visualization to fix multiple vulnerabilities that could be triggered when the products read files in different file formats (CGM, DGN, DXF, and DWG). If a user is tricked to open a malicious file with the affected products, this could lead the application to crash or potentially arbitrary code execution.\n\nSiemens recommends to update to the latest versions and to limit opening of untrusted files from unknown sources in the affected products.\n\nNote:\n\n- This advisory also covers security vulnerabilities recently disclosed by Open Design Alliance [0]\n\n[0] https://www.opendesign.com/security-advisories", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-365397: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.2.0.1 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-365397.json" }, { "category": "self", "summary": "SSA-365397: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.2.0.1 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-365397.txt" }, { "category": "self", "summary": "SSA-365397: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.2.0.1 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-21-222-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-222-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-222-01 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-222-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens JT2Go and Teamcenter Visualization products", "tracking": { "current_release_date": "2025-05-06T06:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-222-01", "initial_release_date": "2021-08-10T00:00:00.000000Z", "revision_history": [ { "date": "2021-08-10T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2025-05-06T06:00:00.000000Z", "legacy_version": "Revision", "number": "2", "summary": "Revision - Fixing typos" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV13.2.0.1", "product": { "name": "JT2Go", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "JT2Go" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV13.2.0.1", "product": { "name": "Teamcenter Visualization", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Teamcenter Visualization" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-32936", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "An out-of-bounds write issue exists in the DXF file-recovering procedure in the Open Design Alliance Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-32936 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-32936 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32936.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-32936" }, { "cve": "CVE-2021-32938", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK (All versions prior to 2022.4) are vulnerable to an out-of-bounds read due to parsing of DWG files resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of service condition or read sensitive information from memory.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-32938 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-32938 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32938.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-32938" }, { "cve": "CVE-2021-32940", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds read issue exists in the DWG file-recovering procedure in the Open Design Alliance Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or read sensitive information from memory locations.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-32940 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-32940 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32940.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-32940" }, { "cve": "CVE-2021-32944", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free issue exists in the DGN file-reading procedure in the Open Design Alliance Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a memory corruption or arbitrary code execution, allowing attackers to cause a denial-of-service condition or execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-32944 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-32944 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32944.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-32944" }, { "cve": "CVE-2021-32948", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "An out-of-bounds write issue exists in the DWG file-reading procedure in the Open Design Alliance Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-32948 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-32948 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32948.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-32948" }, { "cve": "CVE-2021-32950", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds read issue exists within the parsing of DXF files in the Open Design Alliance Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of-service condition or read sensitive information from memory locations.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-32950 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-32950 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32950.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-32950" }, { "cve": "CVE-2021-33717", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "When parsing specially crafted CGM Files, a NULL pointer deference condition could cause the application to crash. The application must be restarted to restore the service. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-33717 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-33717 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-33717.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-33717" } ] }
ICSA-21-222-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting this vulnerability to CISA." }, { "organization": "Trend Micro Zero Day Initiative", "summary": "coordinated disclosure" }, { "organization": "Open Design Alliance", "summary": "coordination efforts" }, { "names": [ "Kai Wang" ], "organization": "Codesafe Team of Legendsec at Qi\u0027anxin Group", "summary": "coordinated disclosure of CVE-2021-33717" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "Siemens has released version V13.2.0.1 for JT2Go and Teamcenter Visualization to fix multiple vulnerabilities that could be triggered when the products read files in different file formats (CGM, DGN, DXF, and DWG). If a user is tricked to open a malicious file with the affected products, this could lead the application to crash or potentially arbitrary code execution.\n\nSiemens recommends to update to the latest versions and to limit opening of untrusted files from unknown sources in the affected products.\n\nNote:\n\n- This advisory also covers security vulnerabilities recently disclosed by Open Design Alliance [0]\n\n[0] https://www.opendesign.com/security-advisories", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-365397: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.2.0.1 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-365397.json" }, { "category": "self", "summary": "SSA-365397: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.2.0.1 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-365397.txt" }, { "category": "self", "summary": "SSA-365397: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.2.0.1 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-21-222-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-222-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-222-01 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-222-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens JT2Go and Teamcenter Visualization products", "tracking": { "current_release_date": "2025-05-06T06:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-222-01", "initial_release_date": "2021-08-10T00:00:00.000000Z", "revision_history": [ { "date": "2021-08-10T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2025-05-06T06:00:00.000000Z", "legacy_version": "Revision", "number": "2", "summary": "Revision - Fixing typos" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV13.2.0.1", "product": { "name": "JT2Go", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "JT2Go" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV13.2.0.1", "product": { "name": "Teamcenter Visualization", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Teamcenter Visualization" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-32936", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "An out-of-bounds write issue exists in the DXF file-recovering procedure in the Open Design Alliance Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-32936 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-32936 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32936.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-32936" }, { "cve": "CVE-2021-32938", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK (All versions prior to 2022.4) are vulnerable to an out-of-bounds read due to parsing of DWG files resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of service condition or read sensitive information from memory.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-32938 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-32938 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32938.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-32938" }, { "cve": "CVE-2021-32940", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds read issue exists in the DWG file-recovering procedure in the Open Design Alliance Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or read sensitive information from memory locations.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-32940 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-32940 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32940.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-32940" }, { "cve": "CVE-2021-32944", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free issue exists in the DGN file-reading procedure in the Open Design Alliance Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a memory corruption or arbitrary code execution, allowing attackers to cause a denial-of-service condition or execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-32944 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-32944 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32944.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-32944" }, { "cve": "CVE-2021-32948", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "An out-of-bounds write issue exists in the DWG file-reading procedure in the Open Design Alliance Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-32948 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-32948 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32948.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-32948" }, { "cve": "CVE-2021-32950", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds read issue exists within the parsing of DXF files in the Open Design Alliance Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of-service condition or read sensitive information from memory locations.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-32950 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-32950 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32950.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-32950" }, { "cve": "CVE-2021-33717", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "When parsing specially crafted CGM Files, a NULL pointer deference condition could cause the application to crash. The application must be restarted to restore the service. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-33717 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-33717 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-33717.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.2.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-33717" } ] }
icsa-23-047-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." }, { "organization": "Michael Heinzl", "summary": "coordinating disclosure of vulnerabilities from CVE-2023-24549 to CVE-2023-24563 and CVE-2023-25140" }, { "organization": "Trend Micro Zero Day Initiative", "summary": "coordinating disclosure of CVE-2023-24564, CVE-2023-22670, CVE-2022-46348, CVE-2022-46345, CVE-2022-46346, CVE-2022-46349, CVE-2022-46347, CVE-2023-24565, CVE-2023-24566, CVE-2023-23579, CVE-2023-22354, CVE-2023-22295, CVE-2023-22321 and CVE-2023-22846" }, { "organization": "Open Design Alliance", "summary": "coordination efforts of CVE-2021-43336, CVE-2021-32938, CVE-2021-32948, CVE-2021-43391, CVE-2021-32936, CVE-2023-22669 and CVE-2023-22670" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "Solid Edge is affected by multiple memory corruption vulnerabilities that could be triggered when the application reads specially crafted files in various formats such as X_B, DWG, DXF, STL, STP, SLDPRT and PAR format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to crash the application, extract data or potentially lead to arbitrary code execution.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-491245.json" }, { "category": "self", "summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-491245.txt" }, { "category": "self", "summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-23-047-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-047-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-047-01 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-047-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Solid Edge", "tracking": { "current_release_date": "2023-03-14T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-047-01", "initial_release_date": "2023-02-14T00:00:00.000000Z", "revision_history": [ { "date": "2023-02-14T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2023-03-14T00:00:00.000000Z", "legacy_version": "1.1", "number": "2", "summary": "Correction in version formats of fixes" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Solid Edge SE2022", "product_id": "CSAFPID-0001" } }, { "category": "product_version_range", "name": "\u003cV222.0MP12", "product": { "name": "Solid Edge SE2022", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Solid Edge SE2022" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV223.0Update2", "product": { "name": "Solid Edge SE2023", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Solid Edge SE2023" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-32936", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DXF files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13408, ZDI-CAN-19072)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-32936" }, { "cve": "CVE-2021-32938", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DWG files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service (crash). (ZDI-CAN-13378, ZDI-CAN-19073)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-32938" }, { "cve": "CVE-2021-32948", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DWG files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-19074, ZDI-CAN-13410)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-32948" }, { "cve": "CVE-2021-43336", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.11 used in affected products contains an out of bounds write vulnerability when parsing a DXF file. An attacker can leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15107, ZDI-CAN-19080, ZDI-CAN-19075)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-43336" }, { "cve": "CVE-2021-43391", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.11 used in affected products contains an out of bounds write vulnerability when parsing a DXF file. An attacker can leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19082)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-43391" }, { "cve": "CVE-2022-46345", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19070)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46345" }, { "cve": "CVE-2022-46346", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19071)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46346" }, { "cve": "CVE-2022-46347", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19079)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46347" }, { "cve": "CVE-2022-46348", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19383)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46348" }, { "cve": "CVE-2022-46349", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19384)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46349" }, { "cve": "CVE-2023-22295", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19448)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22295" }, { "cve": "CVE-2023-22321", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19501)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22321" }, { "cve": "CVE-2023-22354", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products \r\n contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19424)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22354" }, { "cve": "CVE-2023-22669", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK used in affected application is vulnerable to heap-based buffer while parsing specially crafted DWG files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19104)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22669" }, { "cve": "CVE-2023-22670", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK used in affected application is vulnerable to heap-based buffer while parsing specially crafted DWG files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19382)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22670" }, { "cve": "CVE-2023-22846", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19473)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22846" }, { "cve": "CVE-2023-23579", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This could allow an attacker to to execute code in the context of the current process. (ZDI-CAN-19423)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-23579" }, { "cve": "CVE-2023-24549", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24549" }, { "cve": "CVE-2023-24550", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to heap-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24550" }, { "cve": "CVE-2023-24551", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to heap-based buffer underflow while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24551" }, { "cve": "CVE-2023-24552", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24552" }, { "cve": "CVE-2023-24553", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24553" }, { "cve": "CVE-2023-24554", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24554" }, { "cve": "CVE-2023-24555", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24555" }, { "cve": "CVE-2023-24556", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24556" }, { "cve": "CVE-2023-24557", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24557" }, { "cve": "CVE-2023-24558", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24558" }, { "cve": "CVE-2023-24559", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24559" }, { "cve": "CVE-2023-24560", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24560" }, { "cve": "CVE-2023-24561", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24561" }, { "cve": "CVE-2023-24562", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24562" }, { "cve": "CVE-2023-24563", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24563" }, { "cve": "CVE-2023-24564", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "The affected application contains a memory corruption vulnerability while parsing specially crafted DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19069)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-24564" }, { "cve": "CVE-2023-24565", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted STL file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19428)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-24565" }, { "cve": "CVE-2023-24566", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19472)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-24566" }, { "cve": "CVE-2023-24581", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted STP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19425)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-24581" }, { "cve": "CVE-2023-25140", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2023-25140" } ] }
icsa-22-069-06
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "COMOS uses Drawings SDK from Open Design Alliance that is affected by multiple vulnerabilities that could be triggered when the application reads files in DGN, DXF or DWG file formats. If a user is tricked to open a malicious file with the affected application, an attacker could leverage the vulnerability to leak information or potentially perform remote code execution in the context of the current process.\n\nSiemens has released an update for the COMOS and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-155599: File Parsing Vulnerabilities in COMOS - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-155599.json" }, { "category": "self", "summary": "SSA-155599: File Parsing Vulnerabilities in COMOS - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-155599.txt" }, { "category": "self", "summary": "SSA-155599: File Parsing Vulnerabilities in COMOS - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-22-069-06 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-069-06.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-069-06 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-069-06" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens COMOS", "tracking": { "current_release_date": "2025-05-06T06:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-069-06", "initial_release_date": "2022-03-08T00:00:00.000000Z", "revision_history": [ { "date": "2022-03-08T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2025-05-06T06:00:00.000000Z", "legacy_version": "Revision", "number": "2", "summary": "Revision - Fixing typos" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV10.4.1", "product": { "name": "COMOS", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "COMOS" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-25173", "cwe": { "id": "CWE-789", "name": "Memory Allocation with Excessive Size Value" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.12 contains a memory allocation with excessive size vulnerability while parsing specially crafted DGN files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-12019)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25173 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25173 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25173.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25173" }, { "cve": "CVE-2021-25174", "cwe": { "id": "CWE-789", "name": "Memory Allocation with Excessive Size Value" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.12 contains a memory allocation with excessive size vulnerability while parsing specially crafted DGN files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-12026)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25174 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25174 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25174.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25174" }, { "cve": "CVE-2021-25175", "cwe": { "id": "CWE-822", "name": "Untrusted Pointer Dereference" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.11 contains a type conversion vulnerability while parsing specially crafted DXF and DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-11912, ZDI-CAN-11993, ZDI-CAN-11988)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25175 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25175 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25175.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25175" }, { "cve": "CVE-2021-25176", "cwe": { "id": "CWE-822", "name": "Untrusted Pointer Dereference" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.11 contains a NULL pointer dereference vulnerability while parsing DXF and DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-11913, ZDI-CAN-11989)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25176 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25176 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25176.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25176" }, { "cve": "CVE-2021-25177", "cwe": { "id": "CWE-843", "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.11 contains a type confusion issue while parsing specially crafted DXF and DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-11927)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25177 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25177 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25177.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25177" }, { "cve": "CVE-2021-25178", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.11 contains a stack-based buffer overflow vulnerability while parsing specially crafted DXF or DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-11901, ZDI-CAN-12165, ZDI-CAN-12166)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25178 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25178 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25178.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25178" }, { "cve": "CVE-2021-31784", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.6 contains an out-of-bounds write issue while parsing specially crafted DXF files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-11915)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-31784 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-31784 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-31784.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-31784" }, { "cve": "CVE-2021-32936", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DXF files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13408)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32936 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32936 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32936.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32936" }, { "cve": "CVE-2021-32938", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DWG files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service (crash). (ZDI-CAN-13378)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32938 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32938 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32938.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32938" }, { "cve": "CVE-2021-32940", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DWG files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service. (ZDI-CAN-13412)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32940 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32940 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32940.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32940" }, { "cve": "CVE-2021-32944", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.11 contains a use-after-free vulnerability while parsing specially crafted DGN files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-13468, ZDI-CAN-13413)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32944 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32944 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32944.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32944" }, { "cve": "CVE-2021-32946", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to improper check for unusual or exceptional conditions while parsing specially crafted DGN files. This could allow an attacker to cause a denial-of-service condition or execute code in the context of the current process. (ZDI-CAN-13411, ZDI-CAN-13409)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32946 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32946 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32946.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32946" }, { "cve": "CVE-2021-32948", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DWG files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13410)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32948 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32948 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32948.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32948" }, { "cve": "CVE-2021-32950", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DXF files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service. (ZDI-CAN-13415)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32950 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32950 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32950.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32950" }, { "cve": "CVE-2021-32952", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DGN files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13417)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32952 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32952 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32952.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32952" } ] }
ICSA-23-047-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." }, { "organization": "Michael Heinzl", "summary": "coordinating disclosure of vulnerabilities from CVE-2023-24549 to CVE-2023-24563 and CVE-2023-25140" }, { "organization": "Trend Micro Zero Day Initiative", "summary": "coordinating disclosure of CVE-2023-24564, CVE-2023-22670, CVE-2022-46348, CVE-2022-46345, CVE-2022-46346, CVE-2022-46349, CVE-2022-46347, CVE-2023-24565, CVE-2023-24566, CVE-2023-23579, CVE-2023-22354, CVE-2023-22295, CVE-2023-22321 and CVE-2023-22846" }, { "organization": "Open Design Alliance", "summary": "coordination efforts of CVE-2021-43336, CVE-2021-32938, CVE-2021-32948, CVE-2021-43391, CVE-2021-32936, CVE-2023-22669 and CVE-2023-22670" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "Solid Edge is affected by multiple memory corruption vulnerabilities that could be triggered when the application reads specially crafted files in various formats such as X_B, DWG, DXF, STL, STP, SLDPRT and PAR format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to crash the application, extract data or potentially lead to arbitrary code execution.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-491245.json" }, { "category": "self", "summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-491245.txt" }, { "category": "self", "summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-23-047-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-047-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-047-01 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-047-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Solid Edge", "tracking": { "current_release_date": "2023-03-14T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-047-01", "initial_release_date": "2023-02-14T00:00:00.000000Z", "revision_history": [ { "date": "2023-02-14T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2023-03-14T00:00:00.000000Z", "legacy_version": "1.1", "number": "2", "summary": "Correction in version formats of fixes" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Solid Edge SE2022", "product_id": "CSAFPID-0001" } }, { "category": "product_version_range", "name": "\u003cV222.0MP12", "product": { "name": "Solid Edge SE2022", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Solid Edge SE2022" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV223.0Update2", "product": { "name": "Solid Edge SE2023", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Solid Edge SE2023" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-32936", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DXF files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13408, ZDI-CAN-19072)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-32936" }, { "cve": "CVE-2021-32938", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DWG files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service (crash). (ZDI-CAN-13378, ZDI-CAN-19073)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-32938" }, { "cve": "CVE-2021-32948", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DWG files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-19074, ZDI-CAN-13410)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-32948" }, { "cve": "CVE-2021-43336", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.11 used in affected products contains an out of bounds write vulnerability when parsing a DXF file. An attacker can leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15107, ZDI-CAN-19080, ZDI-CAN-19075)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-43336" }, { "cve": "CVE-2021-43391", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.11 used in affected products contains an out of bounds write vulnerability when parsing a DXF file. An attacker can leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19082)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2021-43391" }, { "cve": "CVE-2022-46345", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19070)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46345" }, { "cve": "CVE-2022-46346", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19071)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46346" }, { "cve": "CVE-2022-46347", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19079)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46347" }, { "cve": "CVE-2022-46348", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19383)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46348" }, { "cve": "CVE-2022-46349", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19384)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2022-46349" }, { "cve": "CVE-2023-22295", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19448)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22295" }, { "cve": "CVE-2023-22321", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19501)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22321" }, { "cve": "CVE-2023-22354", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products \r\n contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19424)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22354" }, { "cve": "CVE-2023-22669", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK used in affected application is vulnerable to heap-based buffer while parsing specially crafted DWG files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19104)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22669" }, { "cve": "CVE-2023-22670", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK used in affected application is vulnerable to heap-based buffer while parsing specially crafted DWG files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19382)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22670" }, { "cve": "CVE-2023-22846", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19473)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-22846" }, { "cve": "CVE-2023-23579", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This could allow an attacker to to execute code in the context of the current process. (ZDI-CAN-19423)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-23579" }, { "cve": "CVE-2023-24549", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24549" }, { "cve": "CVE-2023-24550", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to heap-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24550" }, { "cve": "CVE-2023-24551", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to heap-based buffer underflow while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24551" }, { "cve": "CVE-2023-24552", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24552" }, { "cve": "CVE-2023-24553", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24553" }, { "cve": "CVE-2023-24554", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24554" }, { "cve": "CVE-2023-24555", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24555" }, { "cve": "CVE-2023-24556", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24556" }, { "cve": "CVE-2023-24557", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24557" }, { "cve": "CVE-2023-24558", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24558" }, { "cve": "CVE-2023-24559", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24559" }, { "cve": "CVE-2023-24560", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24560" }, { "cve": "CVE-2023-24561", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24561" }, { "cve": "CVE-2023-24562", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24562" }, { "cve": "CVE-2023-24563", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2023-24563" }, { "cve": "CVE-2023-24564", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "The affected application contains a memory corruption vulnerability while parsing specially crafted DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19069)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-24564" }, { "cve": "CVE-2023-24565", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted STL file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19428)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-24565" }, { "cve": "CVE-2023-24566", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19472)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-24566" }, { "cve": "CVE-2023-24581", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted STP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19425)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V223.0Update2 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2023-24581" }, { "cve": "CVE-2023-25140", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V222.0MP12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2023-25140" } ] }
icsa-21-159-02
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Mat Powell", "Brian Gorenc" ], "organization": "Trend Micro\u0027s Zero Day Initiative", "summary": "reporting these vulnerabilities to CISA" }, { "organization": "Siemens ProductCERT", "summary": "assisting coordination with Open Design Alliance." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities may allow code execution in the context of the current process or cause a denial-of-service condition.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "United States", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Recommended Practices" } ], "publisher": { "category": "coordinator", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-21-159-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-159-02.json" }, { "category": "self", "summary": "ICSA Advisory ICSA-21-159-02 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-159-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014" } ], "title": "Open Design Alliance Drawings SDK", "tracking": { "current_release_date": "2021-06-08T06:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-159-02", "initial_release_date": "2021-06-08T06:00:00.000000Z", "revision_history": [ { "date": "2021-06-08T06:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Initial Publication" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c2022.4", "product": { "name": "Open Design Alliance Drawings SDK: \u003c2022.4", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Drawings SDK" }, { "branches": [ { "category": "product_version", "name": "2022.4", "product": { "name": "Open Design Alliance Drawings SDK: 2022.4", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Drawings SDK" } ], "category": "vendor", "name": "Open Design Alliance" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-32938", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected products are vulnerable to an out-of-bounds read due to parsing of DWG files resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of service condition or read sensitive information from memory.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32938" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0001" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-32936", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "An out-of-bounds write issue exists in the DXF file-recovering procedure resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32936" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0001" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-32940", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds read issue exists in the DWG file-recovering procedure resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or read sensitive information from memory locations.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32940" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0001" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-32946", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "An improper check for unusual or exceptional conditions issue exists within the parsing DGN files resulting from the lack of proper validation of the user-supplied data. This may result in several of out-of-bounds problems and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32946" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2021-32948", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "An out-of-bounds write issue exists in the DWG file-reading procedure resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32948" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0001" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-32950", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "An out-of-bounds read issue exists within the parsing of DXF files in the affected product resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of-service condition or read sensitive information from memory locations.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32950" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0001" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-32952", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "An out-of-bounds write issue exists in the DGN file-reading procedure in the affected product resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32952" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2021-32944", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "A use-after-free issue exists in the DGN file-reading procedure in the affected product resulting from the lack of proper validation of user-supplied data. This can result in a memory corruption or arbitrary code execution, allowing attackers to cause a denial-of-service condition or execute code in the context of the current process.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "www.cve.org", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32944" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Open Design Alliance recommends updating to v2022.5 or later (login and ODA membership required).", "product_ids": [ "CSAFPID-0001" ], "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "category": "mitigation", "details": "For more information refer to Open Design Alliance\u0027s Security Advisories.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.opendesign.com/security-advisories" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ] } ] }
ICSA-22-069-06
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "COMOS uses Drawings SDK from Open Design Alliance that is affected by multiple vulnerabilities that could be triggered when the application reads files in DGN, DXF or DWG file formats. If a user is tricked to open a malicious file with the affected application, an attacker could leverage the vulnerability to leak information or potentially perform remote code execution in the context of the current process.\n\nSiemens has released an update for the COMOS and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-155599: File Parsing Vulnerabilities in COMOS - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-155599.json" }, { "category": "self", "summary": "SSA-155599: File Parsing Vulnerabilities in COMOS - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-155599.txt" }, { "category": "self", "summary": "SSA-155599: File Parsing Vulnerabilities in COMOS - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-22-069-06 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-069-06.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-069-06 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-069-06" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens COMOS", "tracking": { "current_release_date": "2025-05-06T06:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-069-06", "initial_release_date": "2022-03-08T00:00:00.000000Z", "revision_history": [ { "date": "2022-03-08T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2025-05-06T06:00:00.000000Z", "legacy_version": "Revision", "number": "2", "summary": "Revision - Fixing typos" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV10.4.1", "product": { "name": "COMOS", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "COMOS" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-25173", "cwe": { "id": "CWE-789", "name": "Memory Allocation with Excessive Size Value" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.12 contains a memory allocation with excessive size vulnerability while parsing specially crafted DGN files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-12019)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25173 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25173 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25173.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25173" }, { "cve": "CVE-2021-25174", "cwe": { "id": "CWE-789", "name": "Memory Allocation with Excessive Size Value" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.12 contains a memory allocation with excessive size vulnerability while parsing specially crafted DGN files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-12026)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25174 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25174 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25174.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25174" }, { "cve": "CVE-2021-25175", "cwe": { "id": "CWE-822", "name": "Untrusted Pointer Dereference" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.11 contains a type conversion vulnerability while parsing specially crafted DXF and DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-11912, ZDI-CAN-11993, ZDI-CAN-11988)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25175 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25175 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25175.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25175" }, { "cve": "CVE-2021-25176", "cwe": { "id": "CWE-822", "name": "Untrusted Pointer Dereference" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.11 contains a NULL pointer dereference vulnerability while parsing DXF and DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-11913, ZDI-CAN-11989)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25176 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25176 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25176.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25176" }, { "cve": "CVE-2021-25177", "cwe": { "id": "CWE-843", "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.11 contains a type confusion issue while parsing specially crafted DXF and DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-11927)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25177 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25177 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25177.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25177" }, { "cve": "CVE-2021-25178", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.11 contains a stack-based buffer overflow vulnerability while parsing specially crafted DXF or DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-11901, ZDI-CAN-12165, ZDI-CAN-12166)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25178 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25178 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25178.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25178" }, { "cve": "CVE-2021-31784", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.6 contains an out-of-bounds write issue while parsing specially crafted DXF files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-11915)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-31784 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-31784 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-31784.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-31784" }, { "cve": "CVE-2021-32936", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DXF files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13408)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32936 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32936 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32936.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32936" }, { "cve": "CVE-2021-32938", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DWG files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service (crash). (ZDI-CAN-13378)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32938 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32938 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32938.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32938" }, { "cve": "CVE-2021-32940", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DWG files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service. (ZDI-CAN-13412)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32940 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32940 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32940.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32940" }, { "cve": "CVE-2021-32944", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.11 contains a use-after-free vulnerability while parsing specially crafted DGN files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-13468, ZDI-CAN-13413)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32944 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32944 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32944.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32944" }, { "cve": "CVE-2021-32946", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to improper check for unusual or exceptional conditions while parsing specially crafted DGN files. This could allow an attacker to cause a denial-of-service condition or execute code in the context of the current process. (ZDI-CAN-13411, ZDI-CAN-13409)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32946 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32946 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32946.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32946" }, { "cve": "CVE-2021-32948", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DWG files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13410)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32948 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32948 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32948.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32948" }, { "cve": "CVE-2021-32950", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DXF files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service. (ZDI-CAN-13415)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32950 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32950 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32950.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32950" }, { "cve": "CVE-2021-32952", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DGN files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13417)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32952 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32952 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32952.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32952" } ] }
CERTFR-2021-AVI-608
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneVendor | Product | Description | ||
---|---|---|---|---|
Siemens | N/A | SIMATIC NET CP 1545-1 | ||
Siemens | N/A | SIMATIC Drive Controller family versions antérieures à V2.9.2 | ||
Siemens | N/A | SIMATIC S7-1500 Software Controller | ||
Siemens | N/A | TIM 1531 IRC (incl. SIPLUS NET variants) versions antérieures à V2.2 | ||
Siemens | N/A | Automation License Manager 6 versions antérieures à V6.0 SP9 Update 2 | ||
Siemens | N/A | SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) versions antérieures à V2.9.2 | ||
Siemens | N/A | SINEC NMS versions antérieures à V1.0 SP2 | ||
Siemens | N/A | Automation License Manager 5 | ||
Siemens | N/A | SIMATIC S7-1200 CPU family (incl. SIPLUS variants) versions V4.4.x antérieures à V4.4.1 | ||
Siemens | N/A | SIMATIC S7-1200 CPU family (incl. SIPLUS variants) versions V4.5.x antérieures à V4.5.1 | ||
Siemens | N/A | SIMATIC S7 PLCSIM Advanced versions antérieures à V4 | ||
Siemens | N/A | T2Go versions antérieures à V13.2.0.2 | ||
Siemens | N/A | Solid Edge SE2021 versions antérieures à SE2021MP7 | ||
Siemens | N/A | Teamcenter Visualization versions antérieures à V13.2.0.2 | ||
Siemens | N/A | SGT-100, SGT-200, SGT-300, SGT-400, SGT-A20, SGT-A35 et SGT-A65 | ||
Siemens | N/A | de nombreux produits SIMATIC et SINUMERIK (cf. avis de sécurité ssa-309571) | ||
Siemens | N/A | SIMATIC NET CP 1543-1 (incl. SIPLUS NET variants) versions antérieures à V3.0 | ||
Siemens | N/A | SIMATIC ET 200SP Open Controller CPU 515SP PC2 (incl. SIPLUS variants) |
Title | Publication Time | Tags | ||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "SIMATIC NET CP 1545-1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC Drive Controller family versions ant\u00e9rieures \u00e0 V2.9.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-1500 Software Controller", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "TIM 1531 IRC (incl. SIPLUS NET variants) versions ant\u00e9rieures \u00e0 V2.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Automation License Manager 6 versions ant\u00e9rieures \u00e0 V6.0 SP9 Update 2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) versions ant\u00e9rieures \u00e0 V2.9.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINEC NMS versions ant\u00e9rieures \u00e0 V1.0 SP2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Automation License Manager 5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants) versions V4.4.x ant\u00e9rieures \u00e0 V4.4.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants) versions V4.5.x ant\u00e9rieures \u00e0 V4.5.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7 PLCSIM Advanced versions ant\u00e9rieures \u00e0 V4", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "T2Go versions ant\u00e9rieures \u00e0 V13.2.0.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Solid Edge SE2021 versions ant\u00e9rieures \u00e0 SE2021MP7", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter Visualization versions ant\u00e9rieures \u00e0 V13.2.0.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SGT-100, SGT-200, SGT-300, SGT-400, SGT-A20, SGT-A35 et SGT-A65", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "de nombreux produits SIMATIC et SINUMERIK (cf. avis de s\u00e9curit\u00e9 ssa-309571)", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC NET CP 1543-1 (incl. SIPLUS NET variants) versions ant\u00e9rieures \u00e0 V3.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC ET 200SP Open Controller CPU 515SP PC2 (incl. SIPLUS variants)", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2021-33721", "url": "https://www.cve.org/CVERecord?id=CVE-2021-33721" }, { "name": "CVE-2021-32944", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32944" }, { "name": "CVE-2021-37178", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37178" }, { "name": "CVE-2021-32936", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32936" }, { "name": "CVE-2016-20009", "url": "https://www.cve.org/CVERecord?id=CVE-2016-20009" }, { "name": "CVE-2021-33717", "url": "https://www.cve.org/CVERecord?id=CVE-2021-33717" }, { "name": "CVE-2021-32946", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32946" }, { "name": "CVE-2020-12360", "url": "https://www.cve.org/CVERecord?id=CVE-2020-12360" }, { "name": "CVE-2020-9272", "url": "https://www.cve.org/CVERecord?id=CVE-2020-9272" }, { "name": "CVE-2021-32938", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32938" }, { "name": "CVE-2021-32940", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32940" }, { "name": "CVE-2020-8703", "url": "https://www.cve.org/CVERecord?id=CVE-2020-8703" }, { "name": "CVE-2020-12357", "url": "https://www.cve.org/CVERecord?id=CVE-2020-12357" }, { "name": "CVE-2021-32948", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32948" }, { "name": "CVE-2021-37172", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37172" }, { "name": "CVE-2020-24513", "url": "https://www.cve.org/CVERecord?id=CVE-2020-24513" }, { "name": "CVE-2021-32952", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32952" }, { "name": "CVE-2020-24507", "url": "https://www.cve.org/CVERecord?id=CVE-2020-24507" }, { "name": "CVE-2021-33738", "url": "https://www.cve.org/CVERecord?id=CVE-2021-33738" }, { "name": "CVE-2020-12358", "url": "https://www.cve.org/CVERecord?id=CVE-2020-12358" }, { "name": "CVE-2021-32950", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32950" }, { "name": "CVE-2020-9273", "url": "https://www.cve.org/CVERecord?id=CVE-2020-9273" }, { "name": "CVE-2021-37180", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37180" }, { "name": "CVE-2020-8670", "url": "https://www.cve.org/CVERecord?id=CVE-2020-8670" }, { "name": "CVE-2020-8704", "url": "https://www.cve.org/CVERecord?id=CVE-2020-8704" }, { "name": "CVE-2021-25659", "url": "https://www.cve.org/CVERecord?id=CVE-2021-25659" }, { "name": "CVE-2020-24486", "url": "https://www.cve.org/CVERecord?id=CVE-2020-24486" }, { "name": "CVE-2020-24506", "url": "https://www.cve.org/CVERecord?id=CVE-2020-24506" }, { "name": "CVE-2020-24512", "url": "https://www.cve.org/CVERecord?id=CVE-2020-24512" }, { "name": "CVE-2021-37179", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37179" }, { "name": "CVE-2020-24511", "url": "https://www.cve.org/CVERecord?id=CVE-2020-24511" }, { "name": "CVE-2020-28397", "url": "https://www.cve.org/CVERecord?id=CVE-2020-28397" } ], "initial_release_date": "2021-08-10T00:00:00", "last_revision_date": "2021-08-10T00:00:00", "links": [], "reference": "CERTFR-2021-AVI-608", "revisions": [ { "description": "Version initiale", "revision_date": "2021-08-10T00:00:00.000000" } ], "risks": [ { "description": "D\u00e9ni de service \u00e0 distance" }, { "description": "Ex\u00e9cution de code arbitraire \u00e0 distance" }, { "description": "Contournement de la politique de s\u00e9curit\u00e9" }, { "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es" }, { "description": "\u00c9l\u00e9vation de privil\u00e8ges" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-309571 du 10 ao\u00fbt 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-309571.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-865327 du 10 ao\u00fbt 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-365397 du 10 ao\u00fbt 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-938030 du 10 ao\u00fbt 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-679335 du 10 ao\u00fbt 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-679335.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-553445 du 10 ao\u00fbt 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-553445.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-158827 du 10 ao\u00fbt 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-158827.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-818688 du 10 ao\u00fbt 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-818688.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-756744 du 10 ao\u00fbt 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-756744.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-830194 du 10 ao\u00fbt 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-830194.pdf" } ] }
CERTFR-2022-AVI-216
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
- Mendix Forgot Password Appstore module versions 3.2.x antérieures à 3.2.2
- Mendix Forgot Password Appstore module versions 3.3.x à 3.5.x antérieures à 3.5.1
- Mendix Applications utilisant Mendix versions 7.x antérieures à 7.23.29
- Mendix Applications utilisant Mendix versions 8.x antérieures à 8.18.16
- COMOS versions antérieures à 10.4.1
- Simcenter STAR-CCM+ Viewer versions antérieures à V2022.1
- SIMOTICS CONNECT 400 versions antérieures à 1.0.0.0
- Climatix POL909 (module AWB) versions antérieures à 11.44
- Climatix POL909 (module AWM) versions antérieures à 11.36
- RUGGEDCOM ROS M2100, RMC8388, RS416v2, RS900G, RS900G (32M), RSG900, RSG920P, RSG2100 (32M), RSG2100P, RSG2100P (32M), RSG2288, RSG2300, RSG2300P, RSG2488, RSL910, RST916C, RST916P et RST2228 versions antérieures à 5.6.0
- SINUMERIK MC versions antérieures à 1.15 SP1
- SINUMERIK ONE versions antérieures à 6.15 SP1
- SINEC INS versions antérieures à 1.0.1.1
- RUGGEDCOM ROX MX5000, RX1400, RX1500, RX1501, RX1510, RX1511, RX1512, RX1524, RX1536 et RX5000 versions antérieures à 2.15.0
- Polarion Subversion Webclient versions antérieures à 21 R2 P2
- RUGGEDCOM ROS i800, i801, i802, i803, M969, M2100, M2200, RMC, RMC20, RMC30, RMC40, RMC41, RMC8388, RP110, RS400, RS401, RS416, RS416v2, RS900 (32M), RS900G, RS900G (32M), RS900GP, RS900L, RS900L, RS900W, RS910, RS910L, RS910W, RS920L, RS920W, RS930L, RS930W, RS940G, RS969, RS8000, RS8000A, RS8000H, RS8000T, RSG900, RSG900C, RSG900G, RSG900R, RSG907R, RSG908C, RSG909R, RSG910C, RSG920P, RSG2100, RSG2100 (32M), RSG2100P, RSG2100P (32M), RSG2200, RSG2288, RSG2300, RSG2300P, RSG2488, RSL910, RST916C, RST916P et RST2228 versions antérieures à 5.6.0
L'éditeur ne propose pas de correctif pour :
- Mendix Applications utilisant Mendix versions 9
- SINEC NMS toutes versions
Se référer aux mesures de contournement proposées dans la section Documentation.
Vendor | Product | Description |
---|
Title | Publication Time | Tags | ||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [], "affected_systems_content": "\u003cul\u003e \u003cli\u003eMendix Forgot Password Appstore module versions 3.2.x ant\u00e9rieures \u00e0 3.2.2\u003c/li\u003e \u003cli\u003eMendix Forgot Password Appstore module versions 3.3.x \u00e0 3.5.x ant\u00e9rieures \u00e0 3.5.1\u003c/li\u003e \u003cli\u003eMendix Applications utilisant Mendix versions 7.x ant\u00e9rieures \u00e0 7.23.29\u003c/li\u003e \u003cli\u003eMendix Applications utilisant Mendix versions 8.x ant\u00e9rieures \u00e0 8.18.16\u003c/li\u003e \u003cli\u003eCOMOS versions ant\u00e9rieures \u00e0 10.4.1\u003c/li\u003e \u003cli\u003eSimcenter STAR-CCM+ Viewer versions ant\u00e9rieures \u00e0 V2022.1\u003c/li\u003e \u003cli\u003eSIMOTICS CONNECT 400 versions ant\u00e9rieures \u00e0 1.0.0.0\u003c/li\u003e \u003cli\u003eClimatix POL909 (module AWB) versions ant\u00e9rieures \u00e0 11.44\u003c/li\u003e \u003cli\u003eClimatix POL909 (module AWM) versions ant\u00e9rieures \u00e0 11.36\u003c/li\u003e \u003cli\u003eRUGGEDCOM ROS M2100, RMC8388, RS416v2, RS900G, RS900G (32M), RSG900, RSG920P, RSG2100 (32M), RSG2100P, RSG2100P (32M), RSG2288, RSG2300, RSG2300P, RSG2488, RSL910, RST916C, RST916P et RST2228 versions ant\u00e9rieures \u00e0 5.6.0\u003c/li\u003e \u003cli\u003eSINUMERIK MC versions ant\u00e9rieures \u00e0 1.15 SP1\u003c/li\u003e \u003cli\u003eSINUMERIK ONE versions ant\u00e9rieures \u00e0 6.15 SP1\u003c/li\u003e \u003cli\u003eSINEC INS versions ant\u00e9rieures \u00e0 1.0.1.1\u003c/li\u003e \u003cli\u003eRUGGEDCOM ROX MX5000, RX1400, RX1500, RX1501, RX1510, RX1511, RX1512, RX1524, RX1536 et RX5000 versions ant\u00e9rieures \u00e0 2.15.0\u003c/li\u003e \u003cli\u003ePolarion Subversion Webclient versions ant\u00e9rieures \u00e0 21 R2 P2\u003c/li\u003e \u003cli\u003eRUGGEDCOM ROS i800, i801, i802, i803, M969, M2100, M2200, RMC, RMC20, RMC30, RMC40, RMC41, RMC8388, RP110, RS400, RS401, RS416, RS416v2, RS900 (32M), RS900G, RS900G (32M), RS900GP, RS900L, RS900L, RS900W, RS910, RS910L, RS910W, RS920L, RS920W, RS930L, RS930W, RS940G, RS969, RS8000, RS8000A, RS8000H, RS8000T, RSG900, RSG900C, RSG900G, RSG900R, RSG907R, RSG908C, RSG909R, RSG910C, RSG920P, RSG2100, RSG2100 (32M), RSG2100P, RSG2100P (32M), RSG2200, RSG2288, RSG2300, RSG2300P, RSG2488, RSL910, RST916C, RST916P et RST2228 versions ant\u00e9rieures \u00e0 5.6.0\u003c/li\u003e \u003c/ul\u003e \u003cp\u003eL\u0027\u00e9diteur ne propose pas de correctif pour :\u003c/p\u003e \u003cul\u003e \u003cli\u003eMendix Applications utilisant Mendix versions 9\u003c/li\u003e \u003cli\u003eSINEC NMS toutes versions\u003c/li\u003e \u003c/ul\u003e \u003cp\u003eSe r\u00e9f\u00e9rer aux mesures de contournement propos\u00e9es dans la section Documentation.\u003c/p\u003e \u003cp\u003e\u0026nbsp;\u003c/p\u003e ", "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2021-44478", "url": "https://www.cve.org/CVERecord?id=CVE-2021-44478" }, { "name": "CVE-2021-22898", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22898" }, { "name": "CVE-2020-13871", "url": "https://www.cve.org/CVERecord?id=CVE-2020-13871" }, { "name": "CVE-2021-42017", "url": "https://www.cve.org/CVERecord?id=CVE-2021-42017" }, { "name": "CVE-2022-24282", "url": "https://www.cve.org/CVERecord?id=CVE-2022-24282" }, { "name": "CVE-2021-25215", "url": "https://www.cve.org/CVERecord?id=CVE-2021-25215" }, { "name": "CVE-2019-19317", "url": "https://www.cve.org/CVERecord?id=CVE-2019-19317" }, { "name": "CVE-2020-8169", "url": "https://www.cve.org/CVERecord?id=CVE-2020-8169" }, { "name": "CVE-2021-25174", "url": "https://www.cve.org/CVERecord?id=CVE-2021-25174" }, { "name": "CVE-2021-22925", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22925" }, { "name": "CVE-2021-37701", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37701" }, { "name": "CVE-2021-32944", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32944" }, { "name": "CVE-2019-19244", "url": "https://www.cve.org/CVERecord?id=CVE-2019-19244" }, { "name": "CVE-2021-27290", "url": "https://www.cve.org/CVERecord?id=CVE-2021-27290" }, { "name": "CVE-2021-42020", "url": "https://www.cve.org/CVERecord?id=CVE-2021-42020" }, { "name": "CVE-2020-8285", "url": "https://www.cve.org/CVERecord?id=CVE-2020-8285" }, { "name": "CVE-2021-22901", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22901" }, { "name": "CVE-2021-22940", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22940" }, { "name": "CVE-2021-32804", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32804" }, { "name": "CVE-2020-13632", "url": "https://www.cve.org/CVERecord?id=CVE-2020-13632" }, { "name": "CVE-2022-24281", "url": "https://www.cve.org/CVERecord?id=CVE-2022-24281" }, { "name": "CVE-2021-32936", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32936" }, { "name": "CVE-2021-22930", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22930" }, { "name": "CVE-2019-19926", "url": "https://www.cve.org/CVERecord?id=CVE-2019-19926" }, { "name": "CVE-2020-9327", "url": "https://www.cve.org/CVERecord?id=CVE-2020-9327" }, { "name": "CVE-2020-8286", "url": "https://www.cve.org/CVERecord?id=CVE-2020-8286" }, { "name": "CVE-2020-7774", "url": "https://www.cve.org/CVERecord?id=CVE-2020-7774" }, { "name": "CVE-2021-22918", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22918" }, { "name": "CVE-2020-27304", "url": "https://www.cve.org/CVERecord?id=CVE-2020-27304" }, { "name": "CVE-2021-32946", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32946" }, { "name": "CVE-2021-41543", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41543" }, { "name": "CVE-2020-8177", "url": "https://www.cve.org/CVERecord?id=CVE-2020-8177" }, { "name": "CVE-2020-1971", "url": "https://www.cve.org/CVERecord?id=CVE-2020-1971" }, { "name": "CVE-2020-13630", "url": "https://www.cve.org/CVERecord?id=CVE-2020-13630" }, { "name": "CVE-2021-3450", "url": "https://www.cve.org/CVERecord?id=CVE-2021-3450" }, { "name": "CVE-2021-22939", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22939" }, { "name": "CVE-2019-19646", "url": "https://www.cve.org/CVERecord?id=CVE-2019-19646" }, { "name": "CVE-2021-40366", "url": "https://www.cve.org/CVERecord?id=CVE-2021-40366" }, { "name": "CVE-2021-41542", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41542" }, { "name": "CVE-2021-41541", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41541" }, { "name": "CVE-2021-22924", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22924" }, { "name": "CVE-2022-24309", "url": "https://www.cve.org/CVERecord?id=CVE-2022-24309" }, { "name": "CVE-2020-8265", "url": "https://www.cve.org/CVERecord?id=CVE-2020-8265" }, { "name": "CVE-2021-37713", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37713" }, { "name": "CVE-2021-22947", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22947" }, { "name": "CVE-2019-19925", "url": "https://www.cve.org/CVERecord?id=CVE-2019-19925" }, { "name": "CVE-2021-22922", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22922" }, { "name": "CVE-2019-19924", "url": "https://www.cve.org/CVERecord?id=CVE-2019-19924" }, { "name": "CVE-2021-32938", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32938" }, { "name": "CVE-2020-11656", "url": "https://www.cve.org/CVERecord?id=CVE-2020-11656" }, { "name": "CVE-2022-26317", "url": "https://www.cve.org/CVERecord?id=CVE-2022-26317" }, { "name": "CVE-2021-22946", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22946" }, { "name": "CVE-2021-37712", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37712" }, { "name": "CVE-2020-8284", "url": "https://www.cve.org/CVERecord?id=CVE-2020-8284" }, { "name": "CVE-2021-32940", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32940" }, { "name": "CVE-2021-3711", "url": "https://www.cve.org/CVERecord?id=CVE-2021-3711" }, { "name": "CVE-2021-37208", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37208" }, { "name": "CVE-2021-32948", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32948" }, { "name": "CVE-2021-3449", "url": "https://www.cve.org/CVERecord?id=CVE-2021-3449" }, { "name": "CVE-2022-26313", "url": "https://www.cve.org/CVERecord?id=CVE-2022-26313" }, { "name": "CVE-2021-22921", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22921" }, { "name": "CVE-2021-25216", "url": "https://www.cve.org/CVERecord?id=CVE-2021-25216" }, { "name": "CVE-2020-15358", "url": "https://www.cve.org/CVERecord?id=CVE-2020-15358" }, { "name": "CVE-2021-43527", "url": "https://www.cve.org/CVERecord?id=CVE-2021-43527" }, { "name": "CVE-2019-19242", "url": "https://www.cve.org/CVERecord?id=CVE-2019-19242" }, { "name": "CVE-2021-22897", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22897" }, { "name": "CVE-2021-32803", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32803" }, { "name": "CVE-2021-25177", "url": "https://www.cve.org/CVERecord?id=CVE-2021-25177" }, { "name": "CVE-2021-25175", "url": "https://www.cve.org/CVERecord?id=CVE-2021-25175" }, { "name": "CVE-2021-22884", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22884" }, { "name": "CVE-2021-32952", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32952" }, { "name": "CVE-2019-19880", "url": "https://www.cve.org/CVERecord?id=CVE-2019-19880" }, { "name": "CVE-2018-7160", "url": "https://www.cve.org/CVERecord?id=CVE-2018-7160" }, { "name": "CVE-2021-32950", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32950" }, { "name": "CVE-2021-3672", "url": "https://www.cve.org/CVERecord?id=CVE-2021-3672" }, { "name": "CVE-2021-31346", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31346" }, { "name": "CVE-2022-26314", "url": "https://www.cve.org/CVERecord?id=CVE-2022-26314" }, { "name": "CVE-2021-31784", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31784" }, { "name": "CVE-2021-22883", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22883" }, { "name": "CVE-2020-8231", "url": "https://www.cve.org/CVERecord?id=CVE-2020-8231" }, { "name": "CVE-2020-13631", "url": "https://www.cve.org/CVERecord?id=CVE-2020-13631" }, { "name": "CVE-2021-25214", "url": "https://www.cve.org/CVERecord?id=CVE-2021-25214" }, { "name": "CVE-2021-22931", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22931" }, { "name": "CVE-2021-31889", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31889" }, { "name": "CVE-2022-24408", "url": "https://www.cve.org/CVERecord?id=CVE-2022-24408" }, { "name": "CVE-2021-42016", "url": "https://www.cve.org/CVERecord?id=CVE-2021-42016" }, { "name": "CVE-2021-3712", "url": "https://www.cve.org/CVERecord?id=CVE-2021-3712" }, { "name": "CVE-2021-39134", "url": "https://www.cve.org/CVERecord?id=CVE-2021-39134" }, { "name": "CVE-2019-19645", "url": "https://www.cve.org/CVERecord?id=CVE-2019-19645" }, { "name": "CVE-2020-11655", "url": "https://www.cve.org/CVERecord?id=CVE-2020-11655" }, { "name": "CVE-2020-8287", "url": "https://www.cve.org/CVERecord?id=CVE-2020-8287" }, { "name": "CVE-2021-22926", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22926" }, { "name": "CVE-2022-24661", "url": "https://www.cve.org/CVERecord?id=CVE-2022-24661" }, { "name": "CVE-2021-22890", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22890" }, { "name": "CVE-2021-25219", "url": "https://www.cve.org/CVERecord?id=CVE-2021-25219" }, { "name": "CVE-2021-23840", "url": "https://www.cve.org/CVERecord?id=CVE-2021-23840" }, { "name": "CVE-2021-42018", "url": "https://www.cve.org/CVERecord?id=CVE-2021-42018" }, { "name": "CVE-2021-22923", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22923" }, { "name": "CVE-2019-19923", "url": "https://www.cve.org/CVERecord?id=CVE-2019-19923" }, { "name": "CVE-2021-39135", "url": "https://www.cve.org/CVERecord?id=CVE-2021-39135" }, { "name": "CVE-2021-25176", "url": "https://www.cve.org/CVERecord?id=CVE-2021-25176" }, { "name": "CVE-2021-31890", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31890" }, { "name": "CVE-2021-25178", "url": "https://www.cve.org/CVERecord?id=CVE-2021-25178" }, { "name": "CVE-2021-22876", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22876" }, { "name": "CVE-2021-23362", "url": "https://www.cve.org/CVERecord?id=CVE-2021-23362" }, { "name": "CVE-2019-19603", "url": "https://www.cve.org/CVERecord?id=CVE-2019-19603" }, { "name": "CVE-2021-25217", "url": "https://www.cve.org/CVERecord?id=CVE-2021-25217" }, { "name": "CVE-2021-25173", "url": "https://www.cve.org/CVERecord?id=CVE-2021-25173" }, { "name": "CVE-2021-22945", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22945" }, { "name": "CVE-2022-25311", "url": "https://www.cve.org/CVERecord?id=CVE-2022-25311" }, { "name": "CVE-2021-31344", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31344" }, { "name": "CVE-2021-37209", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37209" }, { "name": "CVE-2021-42019", "url": "https://www.cve.org/CVERecord?id=CVE-2021-42019" }, { "name": "CVE-2020-8625", "url": "https://www.cve.org/CVERecord?id=CVE-2020-8625" } ], "initial_release_date": "2022-03-08T00:00:00", "last_revision_date": "2022-03-08T00:00:00", "links": [], "reference": "CERTFR-2022-AVI-216", "revisions": [ { "description": "Version initiale", "revision_date": "2022-03-08T00:00:00.000000" } ], "risks": [ { "description": "Ex\u00e9cution de code arbitraire \u00e0 distance" }, { "description": "\u00c9l\u00e9vation de privil\u00e8ges" }, { "description": "D\u00e9ni de service \u00e0 distance" }, { "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es" }, { "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es" }, { "description": "Contournement de la politique de s\u00e9curit\u00e9" }, { "description": "Injection de code indirecte \u00e0 distance (XSS)" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-166747 du 8 mars 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-166747.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-252466 du 8 mars 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-252466.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-562051 du 8 mars 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-562051.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-223353 du 8 mars 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-223353.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-337210 du 8 mars 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-337210.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-148641 du 8 mars 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-148641.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-389290 du 8 mars 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-389290.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-764417 du 8 mars 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-764417.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-256353 du 8 mars 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-256353.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-703715 du 8 mars 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-703715.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-594438 du 8 mars 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-594438.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-415938 du 8 mars 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-415938.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-134279 du 8 mars 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-134279.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-155599 du 8 mars 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-155599.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-406691 du 8 mars 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-406691.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-250085 du 8 mars 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-250085.html" } ] }
CERTFR-2023-AVI-0121
Vulnerability from certfr_avis
De multiples vulnérabilités ont été corrigées dans les produits Siemens. Elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneVendor | Product | Description | ||
---|---|---|---|---|
Siemens | N/A | JT Utilities versions antérieures à V13.2.3.0 | ||
Siemens | N/A | Parasolid V35.0 versions antérieures à V35.0.170 | ||
Siemens | N/A | TIA Project-Server versions antérieures à V1.1 | ||
Siemens | N/A | COMOS V10.3.3.4 versions antérieures à V10.3.3.4.6 | ||
Siemens | N/A | SCALANCE X204IRT (6GK5204-0BA00-2BA3) versions antérieures à V5.5.0 | ||
Siemens | N/A | Parasolid V34.1 versions antérieures à V34.1.242 | ||
Siemens | N/A | TIA Multiuser Server V16 toutes les versions | ||
Siemens | N/A | COMOS V10.2 toutes les versions | ||
Siemens | N/A | Simcenter Femap versions antérieures à V2023.1 | ||
Siemens | N/A | Applications utilisant Mendix versions 9 (V9.12) antérieures à V9.12.10 | ||
Siemens | N/A | Parasolid V35.1 versions antérieures à V35.1.150 | ||
Siemens | N/A | COMOS V10.3.3.3 versions antérieures à V10.3.3.3.9 | ||
Siemens | N/A | SCALANCE XF204IRT (6GK5204-0BA00-2BF2) versions antérieures à V5.5.0 | ||
Siemens | N/A | Brownfield Connectivity - Client versions antérieures à V2.15 | ||
Siemens | N/A | COMOS V10.4.2.0 versions antérieures à V10.4.2.0.25 | ||
Siemens | N/A | TIA Multiuser Server V14 toutes les versions | ||
Siemens | N/A | COMOS V10.3.3.1 versions antérieures à V10.3.3.1.45 | ||
Siemens | N/A | Parasolid V34.0 versions antérieures à V34.0.254 | ||
Siemens | N/A | SiPass integrated AC5102 (ACC-G2) versions antérieures à V2.85.44 | ||
Siemens | N/A | Solid Edge SE2023 versions antérieures à V2023Update2 | ||
Siemens | N/A | SiPass integrated ACC-AP versions antérieures à V2.85.43 | ||
Siemens | N/A | SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2) versions antérieures à V5.5.0 | ||
Siemens | N/A | COMOS V10.4.0.0 versions antérieures à V10.4.0.0.31 | ||
Siemens | N/A | Applications utilisant Mendix versions 7 antérieures à V7.23.34 | ||
Siemens | N/A | Applications utilisant Mendix versions 9 (V9.18) antérieures à V9.18.4 | ||
Siemens | N/A | SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6) versions antérieures à V5.5.0 | ||
Siemens | N/A | SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6) versions antérieures à V5.5.0 | ||
Siemens | N/A | SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3) versions antérieures à V5.5.0 | ||
Siemens | N/A | SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2) versions antérieures à V5.5.0 | ||
Siemens | N/A | TIA Multiuser Server V15 versions antérieures à V15.1 Update 8 | ||
Siemens | N/A | SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6) versions antérieures à V5.5.0 | ||
Siemens | N/A | SCALANCE X202-2IRT (6GK5202-2BB00-2BA3) versions antérieures à V5.5.0 | ||
Siemens | N/A | Applications utilisant Mendix versions 8 antérieures à V8.18.23 | ||
Siemens | N/A | Famille de produits SIMATIC Field PG, SIMATIC IPC et SIMATIC ITP toutes les versions | ||
Siemens | N/A | SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3) versions antérieures à V5.5.0 | ||
Siemens | N/A | Brownfield Connectivity - Gateway versions antérieures à V1.11 | ||
Siemens | N/A | SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3) versions antérieures à V5.5.0 | ||
Siemens | N/A | TIA Multiuser Server V17 toutes les versions | ||
Siemens | N/A | Famille de produits RUGGEDCOM APE1808 toutes les versions | ||
Siemens | N/A | SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3) versions antérieures à V5.5.0 | ||
Siemens | N/A | Applications utilisant Mendix versions 9 (V9.6) antérieures à V9.6.15 | ||
Siemens | N/A | COMOS V10.4.1.0 versions antérieures à V10.4.1.0.32 | ||
Siemens | N/A | SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2) versions antérieures à V5.5.0 | ||
Siemens | N/A | COMOS V10.3.3.2 versions antérieures à V10.3.3.2.33 | ||
Siemens | N/A | Tecnomatix Plant Simulation versions antérieures à V2201.0006 | ||
Siemens | N/A | JT Open versions antérieures à V11.2.3.0 | ||
Siemens | N/A | Applications utilisant Mendix versions 9 antérieures à V9.22.0 |
Title | Publication Time | Tags | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "JT Utilities versions ant\u00e9rieures \u00e0 V13.2.3.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Parasolid V35.0 versions ant\u00e9rieures \u00e0 V35.0.170", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "TIA Project-Server versions ant\u00e9rieures \u00e0 V1.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "COMOS V10.3.3.4 versions ant\u00e9rieures \u00e0 V10.3.3.4.6", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X204IRT (6GK5204-0BA00-2BA3) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Parasolid V34.1 versions ant\u00e9rieures \u00e0 V34.1.242", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "TIA Multiuser Server V16 toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "COMOS V10.2 toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Simcenter Femap versions ant\u00e9rieures \u00e0 V2023.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Applications utilisant Mendix versions 9 (V9.12) ant\u00e9rieures \u00e0 V9.12.10", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Parasolid V35.1 versions ant\u00e9rieures \u00e0 V35.1.150", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "COMOS V10.3.3.3 versions ant\u00e9rieures \u00e0 V10.3.3.3.9", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF204IRT (6GK5204-0BA00-2BF2) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Brownfield Connectivity - Client versions ant\u00e9rieures \u00e0 V2.15", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "COMOS V10.4.2.0 versions ant\u00e9rieures \u00e0 V10.4.2.0.25", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "TIA Multiuser Server V14 toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "COMOS V10.3.3.1 versions ant\u00e9rieures \u00e0 V10.3.3.1.45", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Parasolid V34.0 versions ant\u00e9rieures \u00e0 V34.0.254", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SiPass integrated AC5102 (ACC-G2) versions ant\u00e9rieures \u00e0 V2.85.44", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Solid Edge SE2023 versions ant\u00e9rieures \u00e0 V2023Update2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SiPass integrated ACC-AP versions ant\u00e9rieures \u00e0 V2.85.43", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "COMOS V10.4.0.0 versions ant\u00e9rieures \u00e0 V10.4.0.0.31", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Applications utilisant Mendix versions 7 ant\u00e9rieures \u00e0 V7.23.34", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Applications utilisant Mendix versions 9 (V9.18) ant\u00e9rieures \u00e0 V9.18.4", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "TIA Multiuser Server V15 versions ant\u00e9rieures \u00e0 V15.1 Update 8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X202-2IRT (6GK5202-2BB00-2BA3) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Applications utilisant Mendix versions 8 ant\u00e9rieures \u00e0 V8.18.23", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Famille de produits SIMATIC Field PG, SIMATIC IPC et SIMATIC ITP toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Brownfield Connectivity - Gateway versions ant\u00e9rieures \u00e0 V1.11", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "TIA Multiuser Server V17 toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Famille de produits RUGGEDCOM APE1808 toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Applications utilisant Mendix versions 9 (V9.6) ant\u00e9rieures \u00e0 V9.6.15", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "COMOS V10.4.1.0 versions ant\u00e9rieures \u00e0 V10.4.1.0.32", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2) versions ant\u00e9rieures \u00e0 V5.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "COMOS V10.3.3.2 versions ant\u00e9rieures \u00e0 V10.3.3.2.33", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Tecnomatix Plant Simulation versions ant\u00e9rieures \u00e0 V2201.0006", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "JT Open versions ant\u00e9rieures \u00e0 V11.2.3.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Applications utilisant Mendix versions 9 ant\u00e9rieures \u00e0 V9.22.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2023-24556", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24556" }, { "name": "CVE-2022-1343", "url": "https://www.cve.org/CVERecord?id=CVE-2022-1343" }, { "name": "CVE-2022-1473", "url": "https://www.cve.org/CVERecord?id=CVE-2022-1473" }, { "name": "CVE-2023-24990", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24990" }, { "name": "CVE-2022-39157", "url": "https://www.cve.org/CVERecord?id=CVE-2022-39157" }, { "name": "CVE-2022-46345", "url": "https://www.cve.org/CVERecord?id=CVE-2022-46345" }, { "name": "CVE-2023-22669", "url": "https://www.cve.org/CVERecord?id=CVE-2023-22669" }, { "name": "CVE-2023-24549", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24549" }, { "name": "CVE-2023-24560", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24560" }, { "name": "CVE-2022-31808", "url": "https://www.cve.org/CVERecord?id=CVE-2022-31808" }, { "name": "CVE-2022-46347", "url": "https://www.cve.org/CVERecord?id=CVE-2022-46347" }, { "name": "CVE-2022-27536", "url": "https://www.cve.org/CVERecord?id=CVE-2022-27536" }, { "name": "CVE-2022-46349", "url": "https://www.cve.org/CVERecord?id=CVE-2022-46349" }, { "name": "CVE-2022-24921", "url": "https://www.cve.org/CVERecord?id=CVE-2022-24921" }, { "name": "CVE-2022-28327", "url": "https://www.cve.org/CVERecord?id=CVE-2022-28327" }, { "name": "CVE-2022-1292", "url": "https://www.cve.org/CVERecord?id=CVE-2022-1292" }, { "name": "CVE-2023-24552", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24552" }, { "name": "CVE-2021-43391", "url": "https://www.cve.org/CVERecord?id=CVE-2021-43391" }, { "name": "CVE-2023-24980", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24980" }, { "name": "CVE-2021-32936", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32936" }, { "name": "CVE-2022-33984", "url": "https://www.cve.org/CVERecord?id=CVE-2022-33984" }, { "name": "CVE-2023-24551", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24551" }, { "name": "CVE-2022-46346", "url": "https://www.cve.org/CVERecord?id=CVE-2022-46346" }, { "name": "CVE-2023-24992", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24992" }, { "name": "CVE-2022-21198", "url": "https://www.cve.org/CVERecord?id=CVE-2022-21198" }, { "name": "CVE-2007-5846", "url": "https://www.cve.org/CVERecord?id=CVE-2007-5846" }, { "name": "CVE-2022-33906", "url": "https://www.cve.org/CVERecord?id=CVE-2022-33906" }, { "name": "CVE-2023-24562", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24562" }, { "name": "CVE-2023-24482", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24482" }, { "name": "CVE-2023-24994", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24994" }, { "name": "CVE-2021-41771", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41771" }, { "name": "CVE-2022-43397", "url": "https://www.cve.org/CVERecord?id=CVE-2022-43397" }, { "name": "CVE-2023-24561", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24561" }, { "name": "CVE-2023-24995", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24995" }, { "name": "CVE-2022-30774", "url": "https://www.cve.org/CVERecord?id=CVE-2022-30774" }, { "name": "CVE-2023-24553", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24553" }, { "name": "CVE-2023-24984", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24984" }, { "name": "CVE-2021-32938", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32938" }, { "name": "CVE-2023-24993", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24993" }, { "name": "CVE-2023-24558", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24558" }, { "name": "CVE-2022-46348", "url": "https://www.cve.org/CVERecord?id=CVE-2022-46348" }, { "name": "CVE-2023-22295", "url": "https://www.cve.org/CVERecord?id=CVE-2023-22295" }, { "name": "CVE-2021-32948", "url": "https://www.cve.org/CVERecord?id=CVE-2021-32948" }, { "name": "CVE-2022-33982", "url": "https://www.cve.org/CVERecord?id=CVE-2022-33982" }, { "name": "CVE-2023-22846", "url": "https://www.cve.org/CVERecord?id=CVE-2023-22846" }, { "name": "CVE-2023-24983", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24983" }, { "name": "CVE-2022-47936", "url": "https://www.cve.org/CVERecord?id=CVE-2022-47936" }, { "name": "CVE-2022-47977", "url": "https://www.cve.org/CVERecord?id=CVE-2022-47977" }, { "name": "CVE-2023-24550", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24550" }, { "name": "CVE-2023-24565", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24565" }, { "name": "CVE-2023-25140", "url": "https://www.cve.org/CVERecord?id=CVE-2023-25140" }, { "name": "CVE-2023-24988", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24988" }, { "name": "CVE-2022-35868", "url": "https://www.cve.org/CVERecord?id=CVE-2022-35868" }, { "name": "CVE-2023-24554", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24554" }, { "name": "CVE-2022-33907", "url": "https://www.cve.org/CVERecord?id=CVE-2022-33907" }, { "name": "CVE-2021-43336", "url": "https://www.cve.org/CVERecord?id=CVE-2021-43336" }, { "name": "CVE-2023-24581", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24581" }, { "name": "CVE-2023-22321", "url": "https://www.cve.org/CVERecord?id=CVE-2023-22321" }, { "name": "CVE-2022-24675", "url": "https://www.cve.org/CVERecord?id=CVE-2022-24675" }, { "name": "CVE-2023-24557", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24557" }, { "name": "CVE-2023-24566", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24566" }, { "name": "CVE-2023-24978", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24978" }, { "name": "CVE-2023-24555", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24555" }, { "name": "CVE-2023-24979", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24979" }, { "name": "CVE-2023-22354", "url": "https://www.cve.org/CVERecord?id=CVE-2023-22354" }, { "name": "CVE-2021-41772", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41772" }, { "name": "CVE-2023-24987", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24987" }, { "name": "CVE-2023-24986", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24986" }, { "name": "CVE-2021-44716", "url": "https://www.cve.org/CVERecord?id=CVE-2021-44716" }, { "name": "CVE-2023-23579", "url": "https://www.cve.org/CVERecord?id=CVE-2023-23579" }, { "name": "CVE-2023-24564", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24564" }, { "name": "CVE-2023-24982", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24982" }, { "name": "CVE-2023-24996", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24996" }, { "name": "CVE-2022-31243", "url": "https://www.cve.org/CVERecord?id=CVE-2022-31243" }, { "name": "CVE-2023-24563", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24563" }, { "name": "CVE-2023-24985", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24985" }, { "name": "CVE-2023-24991", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24991" }, { "name": "CVE-2023-24981", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24981" }, { "name": "CVE-2021-44717", "url": "https://www.cve.org/CVERecord?id=CVE-2021-44717" }, { "name": "CVE-2022-1434", "url": "https://www.cve.org/CVERecord?id=CVE-2022-1434" }, { "name": "CVE-2022-33908", "url": "https://www.cve.org/CVERecord?id=CVE-2022-33908" }, { "name": "CVE-2023-23835", "url": "https://www.cve.org/CVERecord?id=CVE-2023-23835" }, { "name": "CVE-2023-24559", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24559" }, { "name": "CVE-2023-24989", "url": "https://www.cve.org/CVERecord?id=CVE-2023-24989" }, { "name": "CVE-2023-22670", "url": "https://www.cve.org/CVERecord?id=CVE-2023-22670" } ], "initial_release_date": "2023-02-14T00:00:00", "last_revision_date": "2023-02-14T00:00:00", "links": [ { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-953464.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-617755.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-658793.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-686975.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-744259.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-693110.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-565356.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-640968.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-450613.pdf" }, { "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-252808.pdf" } ], "reference": "CERTFR-2023-AVI-0121", "revisions": [ { "description": "Version initiale", "revision_date": "2023-02-14T00:00:00.000000" } ], "risks": [ { "description": "D\u00e9ni de service \u00e0 distance" }, { "description": "Ex\u00e9cution de code arbitraire \u00e0 distance" }, { "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es" }, { "description": "Contournement de la politique de s\u00e9curit\u00e9" }, { "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es" }, { "description": "\u00c9l\u00e9vation de privil\u00e8ges" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 corrig\u00e9es dans \u003cspan\nclass=\"textit\"\u003eles produits Siemens\u003c/span\u003e. Elles permettent \u00e0 un\nattaquant de provoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un\nd\u00e9ni de service \u00e0 distance et un contournement de la politique de\ns\u00e9curit\u00e9.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-847261 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-693110 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-953464 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-744259 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-617755 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-658793 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-450613 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-491245 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-686975 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-836777 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-565356 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-252808 du 14 f\u00e9vrier 2023", "url": null }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-640968 du 14 f\u00e9vrier 2023", "url": null } ] }
var-202106-1194
Vulnerability from variot
An out-of-bounds write issue exists in the DWG file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process. Open Design Alliance Provided by Drawings SDK is a drafting software development kit. This product contains multiple vulnerabilities listed below. * Out-of-bounds read (CWE-125) - CVE-2021-32938 It was * Out-of-bounds writing (CWE-787) - CVE-2021-32936 It was * Out-of-bounds read (CWE-125) - CVE-2021-32940 It was * DGN Improper checking of files for abnormal or exceptional conditions (CWE-754) - CVE-2021-32946 It was * Out-of-bounds writing (CWE-787) - CVE-2021-32948 It was * Out-of-bounds read (CWE-125) - CVE-2021-32950 It was * Out-of-bounds writing (CWE-787) - CVE-2021-32952 It was * Use of freed memory (use-after-free) (CWE-416) - CVE-2021-32944The expected impact depends on each vulnerability, but it may be affected as follows. It was * crafted by the attacker DWG Denial of service by opening the file (DoS) triggering a condition or reading sensitive information from memory - CVE-2021-32938 It was * crafted by the attacker DXF Denial of service by opening files via recovery (DoS) state is triggered or code is executed - CVE-2021-32936 It was * crafted by the attacker DWG Denial of service by opening files via recovery (DoS) triggering a condition or reading sensitive information from memory - CVE-2021-32940 It was * crafted by the attacker DGN Denial of service by reading the file (DoS) state is triggered or code is executed - CVE-2021-32946 , CVE-2021-32952 It was * crafted by the attacker DWG Denial of service by opening the file (DoS) state is triggered or code is executed - CVE-2021-32948 It was * crafted by the attacker DXF Denial of service by opening the file (DoS) triggering a condition or reading sensitive information from memory - CVE-2021-32950 It was * Crafted by an attacker by an attacker DGN Denial of service by opening the file (DoS) A condition is triggered or arbitrary code is executed - CVE-2021-32944. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of DWG files. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "affected_products": { "_id": null, "data": [ { "_id": null, "model": "drawing sdk", "scope": null, "trust": 1.4, "vendor": "open design alliance oda", "version": null }, { "_id": null, "model": "teamcenter visualization", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "13.2.0.1" }, { "_id": null, "model": "drawings sdk", "scope": "lt", "trust": 1.0, "vendor": "opendesign", "version": "2022.4" }, { "_id": null, "model": "jt2go", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "13.2.0.1" }, { "_id": null, "model": "comos", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "10.4.1" }, { "_id": null, "model": "drawings sdk", "scope": "eq", "trust": 0.8, "vendor": "open design alliance", "version": "2022.4 all previous s - cve-2021-32938 , cve-2021-32936 , cve-2021-32940 , cve-2021-32948 , cve-2021-32950 , cve-2021-32944" }, { "_id": null, "model": "drawings sdk", "scope": "eq", "trust": 0.8, "vendor": "open design alliance", "version": "2022.5 all previous s - cve-2021-32946 , cve-2021-32952" }, { "_id": null, "model": "drawings sdk", "scope": "eq", "trust": 0.8, "vendor": "open design alliance", "version": null }, { "_id": null, "model": "jt2go", "scope": null, "trust": 0.7, "vendor": "siemens", "version": null }, { "_id": null, "model": "solid edge viewer", "scope": null, "trust": 0.7, "vendor": "siemens", "version": null } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-984" }, { "db": "ZDI", "id": "ZDI-23-128" }, { "db": "ZDI", "id": "ZDI-23-121" }, { "db": "ZDI", "id": "ZDI-23-208" }, { "db": "JVNDB", "id": "JVNDB-2021-001881" }, { "db": "NVD", "id": "CVE-2021-32948" } ] }, "credits": { "_id": null, "data": "Mat Powell of Trend Micro Zero Day Initiative", "sources": [ { "db": "ZDI", "id": "ZDI-21-984" }, { "db": "ZDI", "id": "ZDI-23-208" }, { "db": "CNNVD", "id": "CNNVD-202106-684" } ], "trust": 2.0 }, "cve": "CVE-2021-32948", "cvss": { "_id": null, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CVE-2021-32948", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.1, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "VHN-392934", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "ZDI", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2021-32948", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.8, "userInteraction": "REQUIRED", "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2021-32948", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "IPA", "availabilityImpact": "High", "baseScore": 7.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-001881", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "ZDI", "id": "CVE-2021-32948", "trust": 2.8, "value": "HIGH" }, { "author": "nvd@nist.gov", "id": "CVE-2021-32948", "trust": 1.0, "value": "HIGH" }, { "author": "IPA", "id": "JVNDB-2021-001881", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202106-684", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-392934", "trust": 0.1, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-32948", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-984" }, { "db": "ZDI", "id": "ZDI-23-128" }, { "db": "ZDI", "id": "ZDI-23-121" }, { "db": "ZDI", "id": "ZDI-23-208" }, { "db": "VULHUB", "id": "VHN-392934" }, { "db": "VULMON", "id": "CVE-2021-32948" }, { "db": "JVNDB", "id": "JVNDB-2021-001881" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202106-684" }, { "db": "NVD", "id": "CVE-2021-32948" } ] }, "description": { "_id": null, "data": "An out-of-bounds write issue exists in the DWG file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process. Open Design Alliance Provided by Drawings SDK is a drafting software development kit. This product contains multiple vulnerabilities listed below. * Out-of-bounds read (CWE-125) - CVE-2021-32938 It was * Out-of-bounds writing (CWE-787) - CVE-2021-32936 It was * Out-of-bounds read (CWE-125) - CVE-2021-32940 It was * DGN Improper checking of files for abnormal or exceptional conditions (CWE-754) - CVE-2021-32946 It was * Out-of-bounds writing (CWE-787) - CVE-2021-32948 It was * Out-of-bounds read (CWE-125) - CVE-2021-32950 It was * Out-of-bounds writing (CWE-787) - CVE-2021-32952 It was * Use of freed memory (use-after-free) (CWE-416) - CVE-2021-32944The expected impact depends on each vulnerability, but it may be affected as follows. It was * crafted by the attacker DWG Denial of service by opening the file (DoS) triggering a condition or reading sensitive information from memory - CVE-2021-32938 It was * crafted by the attacker DXF Denial of service by opening files via recovery (DoS) state is triggered or code is executed - CVE-2021-32936 It was * crafted by the attacker DWG Denial of service by opening files via recovery (DoS) triggering a condition or reading sensitive information from memory - CVE-2021-32940 It was * crafted by the attacker DGN Denial of service by reading the file (DoS) state is triggered or code is executed - CVE-2021-32946 , CVE-2021-32952 It was * crafted by the attacker DWG Denial of service by opening the file (DoS) state is triggered or code is executed - CVE-2021-32948 It was * crafted by the attacker DXF Denial of service by opening the file (DoS) triggering a condition or reading sensitive information from memory - CVE-2021-32950 It was * Crafted by an attacker by an attacker DGN Denial of service by opening the file (DoS) A condition is triggered or arbitrary code is executed - CVE-2021-32944. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of DWG files. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-32948" }, { "db": "JVNDB", "id": "JVNDB-2021-001881" }, { "db": "ZDI", "id": "ZDI-21-984" }, { "db": "ZDI", "id": "ZDI-23-128" }, { "db": "ZDI", "id": "ZDI-23-121" }, { "db": "ZDI", "id": "ZDI-23-208" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULHUB", "id": "VHN-392934" }, { "db": "VULMON", "id": "CVE-2021-32948" } ], "trust": 4.86 }, "external_ids": { "_id": null, "data": [ { "db": "NVD", "id": "CVE-2021-32948", "trust": 6.2 }, { "db": "ICS CERT", "id": "ICSA-21-159-02", "trust": 2.6 }, { "db": "ZDI", "id": "ZDI-21-984", "trust": 2.5 }, { "db": "SIEMENS", "id": "SSA-155599", "trust": 1.8 }, { "db": "SIEMENS", "id": "SSA-491245", "trust": 1.8 }, { "db": "SIEMENS", "id": "SSA-365397", "trust": 1.8 }, { "db": "JVN", "id": "JVNVU97514209", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU95145431", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-23-047-01", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-001881", "trust": 0.8 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-13410", "trust": 0.7 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-19145", "trust": 0.7 }, { "db": "ZDI", "id": "ZDI-23-128", "trust": 0.7 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-19135", "trust": 0.7 }, { "db": "ZDI", "id": "ZDI-23-121", "trust": 0.7 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-19074", "trust": 0.7 }, { "db": "ZDI", "id": "ZDI-23-208", "trust": 0.7 }, { "db": "ICS CERT", "id": "ICSA-22-069-06", "trust": 0.7 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2023.0960", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.2700", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2022.1047", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.2046", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2022031102", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021081108", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021060909", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-222-01", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202106-684", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-392934", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2021-32948", "trust": 0.1 } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-984" }, { "db": "ZDI", "id": "ZDI-23-128" }, { "db": "ZDI", "id": "ZDI-23-121" }, { "db": "ZDI", "id": "ZDI-23-208" }, { "db": "VULHUB", "id": "VHN-392934" }, { "db": "VULMON", "id": "CVE-2021-32948" }, { "db": "JVNDB", "id": "JVNDB-2021-001881" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202106-684" }, { "db": "NVD", "id": "CVE-2021-32948" } ] }, "id": "VAR-202106-1194", "iot": { "_id": null, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-392934" } ], "trust": 0.01 }, "last_update_date": "2024-08-14T13:13:19.099000Z", "patch": { "_id": null, "data": [ { "title": "", "trust": 1.4, "url": "https://www.opendesign.com/security-advisories" }, { "title": "Open\u00a0Design\u00a0Alliance\u00a0( Login required ) Open\u00a0Design\u00a0Alliance", "trust": 0.8, "url": "https://docs.opendesign.com/td/frames.html?frmname=topic\u0026frmfile=MovingToNewVersion.html" }, { "title": "", "trust": 0.7, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-222-01https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf" }, { "title": "Siemens has issued an update to correct this vulnerability.", "trust": 0.7, "url": "https://cert-portal.siemens.com/productcert/html/ssa-491245.html" }, { "title": "Open Design Alliance Drawings SDK Buffer error vulnerability fix", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=154861" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=dce38d2a1ec28e091a143e851596b2e8" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=b2237aa5ac819041f827cc4fd4128631" } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-984" }, { "db": "ZDI", "id": "ZDI-23-128" }, { "db": "ZDI", "id": "ZDI-23-121" }, { "db": "ZDI", "id": "ZDI-23-208" }, { "db": "VULMON", "id": "CVE-2021-32948" }, { "db": "JVNDB", "id": "JVNDB-2021-001881" }, { "db": "CNNVD", "id": "CNNVD-202106-684" } ] }, "problemtype_data": { "_id": null, "data": [ { "problemtype": "CWE-787", "trust": 1.1 }, { "problemtype": "Out-of-bounds read (CWE-125) [IPA evaluation ]", "trust": 0.8 }, { "problemtype": " Use of freed memory (CWE-416) [IPA evaluation ]", "trust": 0.8 }, { "problemtype": " Improper checking in exceptional conditions (CWE-754) [IPA evaluation ]", "trust": 0.8 }, { "problemtype": " Out-of-bounds writing (CWE-787) [IPA evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "VULHUB", "id": "VHN-392934" }, { "db": "JVNDB", "id": "JVNDB-2021-001881" }, { "db": "NVD", "id": "CVE-2021-32948" } ] }, "references": { "_id": null, "data": [ { "trust": 2.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02" }, { "trust": 2.5, "url": "https://www.zerodayinitiative.com/advisories/zdi-21-984/" }, { "trust": 1.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" }, { "trust": 1.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf" }, { "trust": 1.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "trust": 1.4, "url": "https://www.opendesign.com/security-advisories" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-32948" }, { "trust": 0.8, "url": "http://jvn.jp/cert/jvnvu95145431" }, { "trust": 0.8, "url": "http://jvn.jp/vu/jvnvu97514209/index.html" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-32936" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-32938" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-32940" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-32944" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-32946" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-32950" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-32952" }, { "trust": 0.8, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-047-01" }, { "trust": 0.7, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-222-01https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf" }, { "trust": 0.7, "url": "https://cert-portal.siemens.com/productcert/html/ssa-491245.html" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-222-01" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2022.1047" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.2046" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021081108" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2023.0960" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.2700" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021060909" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2022031102" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-069-06" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-155599.txt" }, { "trust": 0.1, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-069-06" } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-984" }, { "db": "ZDI", "id": "ZDI-23-128" }, { "db": "ZDI", "id": "ZDI-23-121" }, { "db": "ZDI", "id": "ZDI-23-208" }, { "db": "VULHUB", "id": "VHN-392934" }, { "db": "VULMON", "id": "CVE-2021-32948" }, { "db": "JVNDB", "id": "JVNDB-2021-001881" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202106-684" }, { "db": "NVD", "id": "CVE-2021-32948" } ] }, "sources": { "_id": null, "data": [ { "db": "ZDI", "id": "ZDI-21-984", "ident": null }, { "db": "ZDI", "id": "ZDI-23-128", "ident": null }, { "db": "ZDI", "id": "ZDI-23-121", "ident": null }, { "db": "ZDI", "id": "ZDI-23-208", "ident": null }, { "db": "VULHUB", "id": "VHN-392934", "ident": null }, { "db": "VULMON", "id": "CVE-2021-32948", "ident": null }, { "db": "JVNDB", "id": "JVNDB-2021-001881", "ident": null }, { "db": "CNNVD", "id": "CNNVD-202104-975", "ident": null }, { "db": "CNNVD", "id": "CNNVD-202106-684", "ident": null }, { "db": "NVD", "id": "CVE-2021-32948", "ident": null } ] }, "sources_release_date": { "_id": null, "data": [ { "date": "2021-08-18T00:00:00", "db": "ZDI", "id": "ZDI-21-984", "ident": null }, { "date": "2023-02-09T00:00:00", "db": "ZDI", "id": "ZDI-23-128", "ident": null }, { "date": "2023-02-09T00:00:00", "db": "ZDI", "id": "ZDI-23-121", "ident": null }, { "date": "2023-03-01T00:00:00", "db": "ZDI", "id": "ZDI-23-208", "ident": null }, { "date": "2021-06-17T00:00:00", "db": "VULHUB", "id": "VHN-392934", "ident": null }, { "date": "2021-06-17T00:00:00", "db": "VULMON", "id": "CVE-2021-32948", "ident": null }, { "date": "2021-06-11T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-001881", "ident": null }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975", "ident": null }, { "date": "2021-06-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202106-684", "ident": null }, { "date": "2021-06-17T13:15:08.167000", "db": "NVD", "id": "CVE-2021-32948", "ident": null } ] }, "sources_update_date": { "_id": null, "data": [ { "date": "2021-08-18T00:00:00", "db": "ZDI", "id": "ZDI-21-984", "ident": null }, { "date": "2023-02-09T00:00:00", "db": "ZDI", "id": "ZDI-23-128", "ident": null }, { "date": "2023-02-09T00:00:00", "db": "ZDI", "id": "ZDI-23-121", "ident": null }, { "date": "2023-03-01T00:00:00", "db": "ZDI", "id": "ZDI-23-208", "ident": null }, { "date": "2023-02-14T00:00:00", "db": "VULHUB", "id": "VHN-392934", "ident": null }, { "date": "2023-02-14T00:00:00", "db": "VULMON", "id": "CVE-2021-32948", "ident": null }, { "date": "2023-02-17T05:48:00", "db": "JVNDB", "id": "JVNDB-2021-001881", "ident": null }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975", "ident": null }, { "date": "2023-02-17T00:00:00", "db": "CNNVD", "id": "CNNVD-202106-684", "ident": null }, { "date": "2023-02-14T12:15:11.183000", "db": "NVD", "id": "CVE-2021-32948", "ident": null } ] }, "threat_type": { "_id": null, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202106-684" } ], "trust": 0.6 }, "title": { "_id": null, "data": "Open\u00a0Design\u00a0Alliance\u00a0 Made \u00a0Drawings\u00a0SDK\u00a0 Multiple vulnerabilities in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-001881" } ], "trust": 0.8 }, "type": { "_id": null, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" } ], "trust": 0.6 } }
fkie_cve-2021-32948
Vulnerability from fkie_nvd
URL | Tags | ||
---|---|---|---|
ics-cert@hq.dhs.gov | https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf | Patch, Third Party Advisory | |
ics-cert@hq.dhs.gov | https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf | Patch, Third Party Advisory | |
ics-cert@hq.dhs.gov | https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf | ||
ics-cert@hq.dhs.gov | https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02 | Third Party Advisory, US Government Resource | |
ics-cert@hq.dhs.gov | https://www.zerodayinitiative.com/advisories/ZDI-21-984/ | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf | Patch, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf | Patch, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf | ||
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.zerodayinitiative.com/advisories/ZDI-21-984/ | Third Party Advisory, VDB Entry |
Vendor | Product | Version | |
---|---|---|---|
opendesign | drawings_sdk | * | |
siemens | comos | * | |
siemens | jt2go | * | |
siemens | teamcenter_visualization | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:opendesign:drawings_sdk:*:*:*:*:*:*:*:*", "matchCriteriaId": "FEFEE0EB-BDA4-4D1A-85B5-0D0A80EE26FA", "versionEndExcluding": "2022.4", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:comos:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F0CFB85-CD4F-424C-8B9F-9289D08FA665", "versionEndExcluding": "10.4.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*", "matchCriteriaId": "C811E8B2-CA0C-4A71-A803-A30C4DAF1476", "versionEndExcluding": "13.2.0.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "matchCriteriaId": "87BB2370-46C4-4BEC-8189-1F7FE4C1E12D", "versionEndExcluding": "13.2.0.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An out-of-bounds write issue exists in the DWG file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process." }, { "lang": "es", "value": "Se presenta un problema de escritura fuera de l\u00edmites en el procedimiento de lectura de archivos DWG en Drawings SDK (todas las versiones anteriores a 2022.4) resultando en una falta de comprobaci\u00f3n apropiada de los datos suministrados por el usuario. Esto puede resultar en una escritura m\u00e1s all\u00e1 del final de un b\u00fafer asignado y permitir a atacantes causar una condici\u00f3n de denegaci\u00f3n de servicio o ejecutar c\u00f3digo en el contexto del proceso actual" } ], "id": "CVE-2021-32948", "lastModified": "2024-11-21T06:07:59.170", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-06-17T13:15:08.167", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf" }, { "source": "ics-cert@hq.dhs.gov", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-984/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-984/" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "ics-cert@hq.dhs.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
cnvd-2021-44993
Vulnerability from cnvd
厂商已发布了漏洞修复程序,请及时关注更新: https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02
Name | Open Design Alliance Drawings SDK <2022.4 |
---|
{ "cves": { "cve": { "cveNumber": "CVE-2021-32948", "cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2021-32948" } }, "description": "Open Design Alliance Drawings SDK\u662f\u7f8e\u56fdOpen Design Alliance\u516c\u53f8\u7684\u4e00\u6b3e\u5e94\u7528\u4e8e\u56fe\u7eb8\u8bbe\u8ba1\u7684\u8f6f\u4ef6\u5f00\u53d1\u5305\u3002\u8be5\u5f00\u53d1\u5305\u901a\u8fc7\u65b9\u4fbf\u7684\uff0c\u9762\u5411\u5bf9\u8c61\u7684API\u8bbf\u95ee.dwg\u548c.dgn\u4e2d\u7684\u6570\u636e\uff0c\u63d0\u4f9bC++API\u3001\u652f\u6301\u4fee\u590d\u6587\u4ef6\u3001.NET\uff0cJAVA\uff0cPython\u5f00\u53d1\u8bed\u8a00\u7684\u652f\u6301\u7b49\u529f\u80fd\u3002\n\nOpen Design Alliance Drawings SDK 2022.4\u4e4b\u524d\u7248\u672c\u7684DWG\u6587\u4ef6\u8bfb\u53d6\u8fc7\u7a0b\u5b58\u5728\u8d8a\u754c\u5199\u5165\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u5bf9\u7528\u6237\u63d0\u4f9b\u7684\u6570\u636e\u7f3a\u5c11\u9002\u5f53\u7684\u9a8c\u8bc1\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5bfc\u81f4\u62d2\u7edd\u670d\u52a1\u6216\u5728\u5f53\u524d\u8fdb\u7a0b\u7684\u4e0a\u4e0b\u6587\u4e2d\u6267\u884c\u4ee3\u7801\u3002", "formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://us-cert.cisa.gov/ics/advisories/icsa-21-159-02", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2021-44993", "openTime": "2021-06-25", "patchDescription": "Open Design Alliance Drawings SDK\u662f\u7f8e\u56fdOpen Design Alliance\u516c\u53f8\u7684\u4e00\u6b3e\u5e94\u7528\u4e8e\u56fe\u7eb8\u8bbe\u8ba1\u7684\u8f6f\u4ef6\u5f00\u53d1\u5305\u3002\u8be5\u5f00\u53d1\u5305\u901a\u8fc7\u65b9\u4fbf\u7684\uff0c\u9762\u5411\u5bf9\u8c61\u7684API\u8bbf\u95ee.dwg\u548c.dgn\u4e2d\u7684\u6570\u636e\uff0c\u63d0\u4f9bC++API\u3001\u652f\u6301\u4fee\u590d\u6587\u4ef6\u3001.NET\uff0cJAVA\uff0cPython\u5f00\u53d1\u8bed\u8a00\u7684\u652f\u6301\u7b49\u529f\u80fd\u3002\r\n\r\nOpen Design Alliance Drawings SDK 2022.4\u4e4b\u524d\u7248\u672c\u7684DWG\u6587\u4ef6\u8bfb\u53d6\u8fc7\u7a0b\u5b58\u5728\u8d8a\u754c\u5199\u5165\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u5bf9\u7528\u6237\u63d0\u4f9b\u7684\u6570\u636e\u7f3a\u5c11\u9002\u5f53\u7684\u9a8c\u8bc1\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5bfc\u81f4\u62d2\u7edd\u670d\u52a1\u6216\u5728\u5f53\u524d\u8fdb\u7a0b\u7684\u4e0a\u4e0b\u6587\u4e2d\u6267\u884c\u4ee3\u7801\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002", "patchName": "Open Design Alliance Drawings SDK\u8d8a\u754c\u5199\u5165\u6f0f\u6d1e\uff08CNVD-2021-44993\uff09\u7684\u8865\u4e01", "products": { "product": "Open Design Alliance Drawings SDK \u003c2022.4" }, "referenceLink": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02", "serverity": "\u4e2d", "submitTime": "2021-06-09", "title": "Open Design Alliance Drawings SDK\u8d8a\u754c\u5199\u5165\u6f0f\u6d1e\uff08CNVD-2021-44993\uff09" }
gsd-2021-32948
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2021-32948", "description": "An out-of-bounds write issue exists in the DWG file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.", "id": "GSD-2021-32948" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2021-32948" ], "details": "An out-of-bounds write issue exists in the DWG file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.", "id": "GSD-2021-32948", "modified": "2023-12-13T01:23:08.669219Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2021-32948", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Drawings SDK", "version": { "version_data": [ { "version_value": "All versions prior to 2022.4" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An out-of-bounds write issue exists in the DWG file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "OUT-OF-BOUNDS WRITE CWE-787" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-984/", "refsource": "MISC", "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-984/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:opendesign:drawings_sdk:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2022.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "13.2.0.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "13.2.0.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:comos:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "10.4.1", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2021-32948" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "An out-of-bounds write issue exists in the DWG file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-787" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02", "refsource": "MISC", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf", "refsource": "CONFIRM", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-984/", "refsource": "MISC", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-984/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf", "refsource": "CONFIRM", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf", "refsource": "CONFIRM", "tags": [], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": true }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } }, "lastModifiedDate": "2023-02-14T12:15Z", "publishedDate": "2021-06-17T13:15Z" } } }
ghsa-h38g-9w3j-3782
Vulnerability from github
An out-of-bounds write issue exists in the DWG file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.
{ "affected": [], "aliases": [ "CVE-2021-32948" ], "database_specific": { "cwe_ids": [ "CWE-787" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2021-06-17T13:15:00Z", "severity": "HIGH" }, "details": "An out-of-bounds write issue exists in the DWG file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.", "id": "GHSA-h38g-9w3j-3782", "modified": "2022-05-24T19:05:36Z", "published": "2022-05-24T19:05:36Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-32948" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf" }, { "type": "WEB", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02" }, { "type": "WEB", "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-984" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.