cve-2021-27394
Vulnerability from cvelistv5
Published
2021-04-16 20:00
Modified
2024-08-03 20:48
Severity ?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.19), Mendix Applications using Mendix 8 (All versions < V8.17.0), Mendix Applications using Mendix 8 (V8.12) (All versions < V8.12.5), Mendix Applications using Mendix 8 (V8.6) (All versions < V8.6.9), Mendix Applications using Mendix 9 (All versions < V9.0.5). Authenticated, non-administrative users could modify their privileges by manipulating the user role under certain circumstances, allowing them to gain administrative privileges.
Impacted products
Vendor Product Version
Siemens Mendix Applications using Mendix 8 Version: All versions < V8.17.0
Siemens Mendix Applications using Mendix 8 (V8.12) Version: All versions < V8.12.5
Siemens Mendix Applications using Mendix 8 (V8.6) Version: All versions < V8.6.9
Siemens Mendix Applications using Mendix 9 Version: All versions < V9.0.5
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:48:16.703Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-875726.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.23.19"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 8",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.17.0"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 8 (V8.12)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.12.5"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 8 (V8.6)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.6.9"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.19), Mendix Applications using Mendix 8 (All versions \u003c V8.17.0), Mendix Applications using Mendix 8 (V8.12) (All versions \u003c V8.12.5), Mendix Applications using Mendix 8 (V8.6) (All versions \u003c V8.6.9), Mendix Applications using Mendix 9 (All versions \u003c V9.0.5). Authenticated, non-administrative users could modify their privileges by manipulating the user role under certain circumstances, allowing them to gain administrative privileges."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269: Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-04-16T20:00:14",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-875726.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-27394",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 7",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.23.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 8",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.17.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 8 (V8.12)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.12.5"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 8 (V8.6)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.6.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.19), Mendix Applications using Mendix 8 (All versions \u003c V8.17.0), Mendix Applications using Mendix 8 (V8.12) (All versions \u003c V8.12.5), Mendix Applications using Mendix 8 (V8.6) (All versions \u003c V8.6.9), Mendix Applications using Mendix 9 (All versions \u003c V9.0.5). Authenticated, non-administrative users could modify their privileges by manipulating the user role under certain circumstances, allowing them to gain administrative privileges."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-269: Improper Privilege Management"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-875726.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-875726.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-27394",
    "datePublished": "2021-04-16T20:00:14",
    "dateReserved": "2021-02-18T00:00:00",
    "dateUpdated": "2024-08-03T20:48:16.703Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-27394\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-04-16T20:15:12.387\",\"lastModified\":\"2024-11-21T05:57:54.453\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.19), Mendix Applications using Mendix 8 (All versions \u003c V8.17.0), Mendix Applications using Mendix 8 (V8.12) (All versions \u003c V8.12.5), Mendix Applications using Mendix 8 (V8.6) (All versions \u003c V8.6.9), Mendix Applications using Mendix 9 (All versions \u003c V9.0.5). Authenticated, non-administrative users could modify their privileges by manipulating the user role under certain circumstances, allowing them to gain administrative privileges.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Mendix Applications usando Mendix 7 (todas las versiones anteriores a V7.23.19), Mendix Applications usando Mendix 8 (todas las versiones anteriores a V8.17.0), Mendix Applications usando Mendix 8 (V8.12) (todas las versiones anteriores a V8. 12.5), Mendix Applications usando Mendix 8 (V8.6) (Todas las versiones anteriores a V8.6.9), Mendix Applications usando Mendix 9 (Todas las versiones anteriores a V9.0.5).\u0026#xa0;Los usuarios no administrativos autenticados pueden modificar sus privilegios al manipular la funci\u00f3n del usuario en determinadas circunstancias, permiti\u00e9ndoles alcanzar privilegios administrativos\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-269\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0.2\",\"versionEndExcluding\":\"7.23.19\",\"matchCriteriaId\":\"46727C96-E577-40DC-9CB7-84B1F9FE2761\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.0.0\",\"versionEndExcluding\":\"8.17.0\",\"matchCriteriaId\":\"619470AA-8464-4830-8EEF-0F3A19136A3D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.0.0\",\"versionEndExcluding\":\"9.0.5\",\"matchCriteriaId\":\"1454FE73-9896-48DF-92C7-7B64F0F200E6\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.6.0\",\"versionEndExcluding\":\"8.6.9\",\"matchCriteriaId\":\"F0774932-F62C-413A-878C-A346609D5CBF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.12.0\",\"versionEndExcluding\":\"8.12.5\",\"matchCriteriaId\":\"DA73E222-A316-4EA9-8C25-DAB0D63182A7\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-875726.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-875726.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.