Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2020-7584 (GCVE-0-2020-7584)
Vulnerability from cvelistv5
- CWE-400 - Uncontrolled Resource Consumption
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens AG | SIMATIC S7-200 SMART CPU family |
Version: All versions >= V2.2 < V2.5.1 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.577Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC S7-200 SMART CPU family",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.2 \u003c V2.5.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC S7-200 SMART CPU family (All versions \u003e= V2.2 \u003c V2.5.1). Affected devices do not properly handle large numbers of new incomming connections and could crash under certain circumstances. An attacker may leverage this to cause a Denial-of-Service situation."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-14T13:18:05",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-7584",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC S7-200 SMART CPU family",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V2.2 \u003c V2.5.1"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC S7-200 SMART CPU family (All versions \u003e= V2.2 \u003c V2.5.1). Affected devices do not properly handle large numbers of new incomming connections and could crash under certain circumstances. An attacker may leverage this to cause a Denial-of-Service situation."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400: Uncontrolled Resource Consumption"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-7584",
"datePublished": "2020-07-14T13:18:05",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:19.577Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2020-7584\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2020-07-14T14:15:18.650\",\"lastModified\":\"2024-11-21T05:37:25.200\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC S7-200 SMART CPU family (All versions \u003e= V2.2 \u003c V2.5.1). Affected devices do not properly handle large numbers of new incomming connections and could crash under certain circumstances. An attacker may leverage this to cause a Denial-of-Service situation.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en la familia de CPU SIMATIC S7-200 SMART (Todas las versiones posteriores e incluyendo a V2.2 anteriores a V2.5.1). Los dispositivos afectados no manejan apropiadamente un gran n\u00famero de nuevas conexiones entrantes y podr\u00edan bloquearse bajo determinadas circunstancias. Un atacante puede aprovechar esto para causar una situaci\u00f3n de Denegaci\u00f3n de Servicio\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-200_smart_sr_cpu_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2.2\",\"versionEndExcluding\":\"2.5.1\",\"matchCriteriaId\":\"4FE8A428-3F0B-4A1C-BE47-2C1E82C47923\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-200_smart_sr_cpu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CD87FA1B-10BF-4712-B229-A9AE3A9DECEC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-200_smart_st_cpu_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2.2\",\"versionEndExcluding\":\"2.5.1\",\"matchCriteriaId\":\"CCB78749-4917-4060-8403-685790A1F12C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-200_smart_st_cpu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0E97C885-E63F-4979-AD91-30A7B4F88AC8\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
ICSA-20-196-06
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"names": [
"Ezequiel Fernandez"
],
"organization": "Siemens",
"summary": "reporting this vulnerability to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Chemical, Critical Manufacturing, Energy, Food and Agriculture, Water and Wastewater Systems",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target this vulnerability.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-20-196-06 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2020/icsa-20-196-06.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-20-196-06 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-196-06"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens SIMATIC S7-200 SMART CPU Family",
"tracking": {
"current_release_date": "2020-07-14T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-20-196-06",
"initial_release_date": "2020-07-14T00:00:00.000000Z",
"revision_history": [
{
"date": "2020-07-14T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-20-196-06 Siemens SIMATIC S7-200 SMART CPU Family"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e= \u003c= 2.2 | 2.5.1",
"product": {
"name": "SIMATIC S7-200 SMART CPU family: v2.2 and later prior to v2.5.1",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-200 SMART CPU family"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-7584",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"category": "summary",
"text": "The affected devices do not properly handle large numbers of new incoming connections and could crash under certain circumstances.CVE-2020-7584 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7584"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Siemens recommends users update to v2.5.1 and limit network access to device to trusted sources.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109765009/"
},
{
"category": "vendor_fix",
"details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for Industrial Security and following the recommendations in the product manuals.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.siemens.com/cert/operational-guidelines-industrial-security"
},
{
"category": "vendor_fix",
"details": "Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.siemens.com/industrialsecurity"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
}
]
}
icsa-20-196-06
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"names": [
"Ezequiel Fernandez"
],
"organization": "Siemens",
"summary": "reporting this vulnerability to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Chemical, Critical Manufacturing, Energy, Food and Agriculture, Water and Wastewater Systems",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target this vulnerability.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-20-196-06 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2020/icsa-20-196-06.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-20-196-06 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-196-06"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens SIMATIC S7-200 SMART CPU Family",
"tracking": {
"current_release_date": "2020-07-14T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-20-196-06",
"initial_release_date": "2020-07-14T00:00:00.000000Z",
"revision_history": [
{
"date": "2020-07-14T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-20-196-06 Siemens SIMATIC S7-200 SMART CPU Family"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e= \u003c= 2.2 | 2.5.1",
"product": {
"name": "SIMATIC S7-200 SMART CPU family: v2.2 and later prior to v2.5.1",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-200 SMART CPU family"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-7584",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"category": "summary",
"text": "The affected devices do not properly handle large numbers of new incoming connections and could crash under certain circumstances.CVE-2020-7584 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7584"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Siemens recommends users update to v2.5.1 and limit network access to device to trusted sources.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109765009/"
},
{
"category": "vendor_fix",
"details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens \u0027 operational guidelines for Industrial Security and following the recommendations in the product manuals.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.siemens.com/cert/operational-guidelines-industrial-security"
},
{
"category": "vendor_fix",
"details": "Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.siemens.com/industrialsecurity"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
}
]
}
ghsa-vpvj-7qfp-4qgg
Vulnerability from github
A vulnerability has been identified in SIMATIC S7-200 SMART CPU family (All versions >= V2.2 < V2.5.1). Affected devices do not properly handle large numbers of new incomming connections and could crash under certain circumstances. An attacker may leverage this to cause a Denial-of-Service situation.
{
"affected": [],
"aliases": [
"CVE-2020-7584"
],
"database_specific": {
"cwe_ids": [],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2020-07-14T14:15:00Z",
"severity": "MODERATE"
},
"details": "A vulnerability has been identified in SIMATIC S7-200 SMART CPU family (All versions \u003e= V2.2 \u003c V2.5.1). Affected devices do not properly handle large numbers of new incomming connections and could crash under certain circumstances. An attacker may leverage this to cause a Denial-of-Service situation.",
"id": "GHSA-vpvj-7qfp-4qgg",
"modified": "2022-05-24T17:22:55Z",
"published": "2022-05-24T17:22:55Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2020-7584"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf"
}
],
"schema_version": "1.4.0",
"severity": []
}
fkie_cve-2020-7584
Vulnerability from fkie_nvd
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-200_smart_sr_cpu_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4FE8A428-3F0B-4A1C-BE47-2C1E82C47923",
"versionEndExcluding": "2.5.1",
"versionStartIncluding": "2.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-200_smart_sr_cpu:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CD87FA1B-10BF-4712-B229-A9AE3A9DECEC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-200_smart_st_cpu_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CCB78749-4917-4060-8403-685790A1F12C",
"versionEndExcluding": "2.5.1",
"versionStartIncluding": "2.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-200_smart_st_cpu:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0E97C885-E63F-4979-AD91-30A7B4F88AC8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC S7-200 SMART CPU family (All versions \u003e= V2.2 \u003c V2.5.1). Affected devices do not properly handle large numbers of new incomming connections and could crash under certain circumstances. An attacker may leverage this to cause a Denial-of-Service situation."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en la familia de CPU SIMATIC S7-200 SMART (Todas las versiones posteriores e incluyendo a V2.2 anteriores a V2.5.1). Los dispositivos afectados no manejan apropiadamente un gran n\u00famero de nuevas conexiones entrantes y podr\u00edan bloquearse bajo determinadas circunstancias. Un atacante puede aprovechar esto para causar una situaci\u00f3n de Denegaci\u00f3n de Servicio"
}
],
"id": "CVE-2020-7584",
"lastModified": "2024-11-21T05:37:25.200",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-07-14T14:15:18.650",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-400"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-400"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
gsd-2020-7584
Vulnerability from gsd
{
"GSD": {
"alias": "CVE-2020-7584",
"description": "A vulnerability has been identified in SIMATIC S7-200 SMART CPU family (All versions \u003e= V2.2 \u003c V2.5.1). Affected devices do not properly handle large numbers of new incomming connections and could crash under certain circumstances. An attacker may leverage this to cause a Denial-of-Service situation.",
"id": "GSD-2020-7584"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2020-7584"
],
"details": "A vulnerability has been identified in SIMATIC S7-200 SMART CPU family (All versions \u003e= V2.2 \u003c V2.5.1). Affected devices do not properly handle large numbers of new incomming connections and could crash under certain circumstances. An attacker may leverage this to cause a Denial-of-Service situation.",
"id": "GSD-2020-7584",
"modified": "2023-12-13T01:21:51.967477Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-7584",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC S7-200 SMART CPU family",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V2.2 \u003c V2.5.1"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC S7-200 SMART CPU family (All versions \u003e= V2.2 \u003c V2.5.1). Affected devices do not properly handle large numbers of new incomming connections and could crash under certain circumstances. An attacker may leverage this to cause a Denial-of-Service situation."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400: Uncontrolled Resource Consumption"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-200_smart_sr_cpu_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.5.1",
"versionStartIncluding": "2.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-200_smart_sr_cpu:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-200_smart_st_cpu_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.5.1",
"versionStartIncluding": "2.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-200_smart_st_cpu:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-7584"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC S7-200 SMART CPU family (All versions \u003e= V2.2 \u003c V2.5.1). Affected devices do not properly handle large numbers of new incomming connections and could crash under certain circumstances. An attacker may leverage this to cause a Denial-of-Service situation."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-400"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
},
"lastModifiedDate": "2020-07-17T18:33Z",
"publishedDate": "2020-07-14T14:15Z"
}
}
}
var-202007-1235
Vulnerability from variot
A vulnerability has been identified in SIMATIC S7-200 SMART CPU family (All versions >= V2.2 < V2.5.1). Affected devices do not properly handle large numbers of new incomming connections and could crash under certain circumstances. An attacker may leverage this to cause a Denial-of-Service situation. SIMATIC S7-200 SMART CPU Is vulnerable to a resource exhaustion.Denial of service (DoS) It may be put in a state. Siemens SIMATIC S7-200 Smart is a programmable logic controller (PLC) of Germany's Siemens (Siemens) company used in small and medium-sized automation systems. Attackers can use vulnerabilities to cause denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202007-1235",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic s7-200 smart st cpu",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "2.2"
},
{
"model": "simatic s7-200 smart sr cpu",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.5.1"
},
{
"model": "simatic s7-200 smart st cpu",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.5.1"
},
{
"model": "simatic s7-200 smart sr cpu",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "2.2"
},
{
"model": "simatic s7-200 smart",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic s7-200 smart",
"scope": "lt",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": "simatic s7-200 smart firmware 2.2 that\u0027s all 2.5.1"
},
{
"model": "simatic s7-200 smart cpu family",
"scope": "gte",
"trust": 0.6,
"vendor": "siemens",
"version": "v2.2,\u003cv2.5.1"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-40865"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007898"
},
{
"db": "NVD",
"id": "CVE-2020-7584"
}
]
},
"cve": "CVE-2020-7584",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CVE-2020-7584",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2020-40865",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2020-7584",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2020-7584",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2020-7584",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2020-7584",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2020-40865",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202007-582",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-40865"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007898"
},
{
"db": "CNNVD",
"id": "CNNVD-202007-582"
},
{
"db": "NVD",
"id": "CVE-2020-7584"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SIMATIC S7-200 SMART CPU family (All versions \u003e= V2.2 \u003c V2.5.1). Affected devices do not properly handle large numbers of new incomming connections and could crash under certain circumstances. An attacker may leverage this to cause a Denial-of-Service situation. SIMATIC S7-200 SMART CPU Is vulnerable to a resource exhaustion.Denial of service (DoS) It may be put in a state. Siemens SIMATIC S7-200 Smart is a programmable logic controller (PLC) of Germany\u0027s Siemens (Siemens) company used in small and medium-sized automation systems. Attackers can use vulnerabilities to cause denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-7584"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007898"
},
{
"db": "CNVD",
"id": "CNVD-2020-40865"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-7584",
"trust": 3.0
},
{
"db": "SIEMENS",
"id": "SSA-589181",
"trust": 2.2
},
{
"db": "ICS CERT",
"id": "ICSA-20-196-06",
"trust": 1.4
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007898",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2020-40865",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2020.2387",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202007-582",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-40865"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007898"
},
{
"db": "CNNVD",
"id": "CNNVD-202007-582"
},
{
"db": "NVD",
"id": "CVE-2020-7584"
}
]
},
"id": "VAR-202007-1235",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-40865"
}
],
"trust": 1.37777775
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-40865"
}
]
},
"last_update_date": "2024-11-23T21:35:29.652000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-589181",
"trust": 0.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf"
},
{
"title": "Patch for Denial of Service Vulnerability in Siemens SIMATIC S7-200 Smart CPU Series",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/226103"
},
{
"title": "SIMATIC S7-200 SMART SR CPU and ST CPU Remediation of resource management error vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=124357"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-40865"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007898"
},
{
"db": "CNNVD",
"id": "CNNVD-202007-582"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-400",
"trust": 1.0
},
{
"problemtype": "Resource exhaustion (CWE-400) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007898"
},
{
"db": "NVD",
"id": "CVE-2020-7584"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.2,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-7584"
},
{
"trust": 1.4,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-196-06"
},
{
"trust": 0.6,
"url": "https://vigilance.fr/vulnerability/simatic-denial-of-service-via-incomming-connection-32814"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2020.2387/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-40865"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007898"
},
{
"db": "CNNVD",
"id": "CNNVD-202007-582"
},
{
"db": "NVD",
"id": "CVE-2020-7584"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2020-40865"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007898"
},
{
"db": "CNNVD",
"id": "CNNVD-202007-582"
},
{
"db": "NVD",
"id": "CVE-2020-7584"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-07-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-40865"
},
{
"date": "2020-08-28T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-007898"
},
{
"date": "2020-07-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202007-582"
},
{
"date": "2020-07-14T14:15:18.650000",
"db": "NVD",
"id": "CVE-2020-7584"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-07-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-40865"
},
{
"date": "2020-09-01T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-007898"
},
{
"date": "2020-07-20T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202007-582"
},
{
"date": "2024-11-21T05:37:25.200000",
"db": "NVD",
"id": "CVE-2020-7584"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202007-582"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "SIMATIC\u00a0S7-200\u00a0SMART\u00a0CPU\u00a0 Resource Depletion Vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007898"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "resource management error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202007-582"
}
],
"trust": 0.6
}
}
cnvd-2020-40865
Vulnerability from cnvd
用户可参考如下供应商提供的安全公告获得补丁信息: https://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf
| Name | Siemens SIMATIC S7-200 SMART CPU family >= V2.2,< V2.5.1 |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2020-7584"
}
},
"description": "Siemens SIMATIC S7-200 Smart\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u5e94\u7528\u4e8e\u4e2d\u5c0f\u578b\u81ea\u52a8\u5316\u7cfb\u7edf\u4e2d\u7684\u53ef\u7f16\u7a0b\u903b\u8f91\u63a7\u5236\u5668\uff08PLC\uff09\u3002\n\nSiemens SIMATIC S7-200 Smart CPU\u7cfb\u5217\u5b58\u5728\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u9020\u6210\u62d2\u7edd\u670d\u52a1\u60c5\u51b5\u3002",
"formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u4f9b\u5e94\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u516c\u544a\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2020-40865",
"openTime": "2020-07-19",
"patchDescription": "Siemens SIMATIC S7-200 Smart\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u5e94\u7528\u4e8e\u4e2d\u5c0f\u578b\u81ea\u52a8\u5316\u7cfb\u7edf\u4e2d\u7684\u53ef\u7f16\u7a0b\u903b\u8f91\u63a7\u5236\u5668\uff08PLC\uff09\u3002\r\n\r\nSiemens SIMATIC S7-200 Smart CPU\u7cfb\u5217\u5b58\u5728\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u9020\u6210\u62d2\u7edd\u670d\u52a1\u60c5\u51b5\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Siemens SIMATIC S7-200 Smart CPU\u7cfb\u5217\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": "Siemens SIMATIC S7-200 SMART CPU family \u003e= V2.2\uff0c\u003c V2.5.1"
},
"referenceLink": "https://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf",
"serverity": "\u9ad8",
"submitTime": "2020-07-15",
"title": "Siemens SIMATIC S7-200 Smart CPU\u7cfb\u5217\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e"
}
CERTFR-2020-AVI-439
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une élévation de privilèges.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | LOGO! 8 BM (incl. variantes SIPLUS) versions antérieures à V1.82.04 | ||
| Siemens | N/A | SIMATIC S7-300 CPU (incl. variantes ET200CPUs et SIPLUS) versions antérieures à V3.X.17 | ||
| Siemens | N/A | SIMATIC TDC CP51M1 versions antérieures à V1.1.8 | ||
| Siemens | N/A | SICAM T versions antérieures à V2.18 | ||
| Siemens | N/A | Opcenter Execution Process versions antérieures à v3.2 | ||
| Siemens | N/A | SICAM MMU versions antérieures à V2.05 | ||
| Siemens | N/A | Camstar Enterprise Platform : une migration vers Opcenter Execution Core 8.2 est requise | ||
| Siemens | N/A | SIMATIC IT LMS, Production Suite, Notifier Server for Windows, PCS neo | ||
| Siemens | N/A | SICAM SGU | ||
| Siemens | N/A | LOGO! 8 BM (incl. variantes SIPLUS) versions antérieures à V1.82.03 | ||
| Siemens | N/A | Opcenter RD&L versions antérieures à 8.1 | ||
| Siemens | N/A | SIMATIC WinCC Runtime Advanced | ||
| Siemens | N/A | SPPA-T3000 APC UPS avec carte NMC AP9630 ou AP9631 | ||
| Siemens | N/A | SIMATIC STEP 7 (TIA Portal) v16 versions antérieures à V16 update 2 | ||
| Siemens | N/A | SPPA-T3000 Application Server et Terminal Server | ||
| Siemens | N/A | SIMATIC TDC CPU555 versions antérieures à V1.1.1 | ||
| Siemens | N/A | Opcenter Execution Discrete versions antérieures à v3.2 | ||
| Siemens | N/A | Opcenter Execution Core versions antérieures à v8.2 | ||
| Siemens | N/A | SIMATIC S7-200 SMART CPU versions antérieures à V2.5.1 | ||
| Siemens | N/A | Opcenter Quality versions antérieures à 11.3 | ||
| Siemens | N/A | Opcenter Intelligence | ||
| Siemens | N/A | LOGO! 8 BM (incl. variantes SIPLUS) versions antérieures à V1.81.04 | ||
| Siemens | N/A | SIMATIC HMI Basic Panels première et seconde génération, Comfort Panels, Mobile Panels de seconde génération (incl. variantes SIPLUS) | ||
| Siemens | N/A | SIMATIC STEP 7 (TIA Portal) v15 | ||
| Siemens | N/A | SINUMERIK 840D sl versions antérieures à V4.8.6 | ||
| Siemens | N/A | SIMATIC HMI KTP700F Mobile Arctic | ||
| Siemens | N/A | Opcenter Execution Foundation versions antérieures à v3.2 | ||
| Siemens | N/A | SIMOCODE ES et Soft Starter ES | ||
| Siemens | N/A | SINUMERIK 840D sl versions antérieures à V4.94 |
| Title | Publication Time | Tags | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "LOGO! 8 BM (incl. variantes SIPLUS) versions ant\u00e9rieures \u00e0 V1.82.04",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU (incl. variantes ET200CPUs et SIPLUS) versions ant\u00e9rieures \u00e0 V3.X.17",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC TDC CP51M1 versions ant\u00e9rieures \u00e0 V1.1.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SICAM T versions ant\u00e9rieures \u00e0 V2.18",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Opcenter Execution Process versions ant\u00e9rieures \u00e0 v3.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SICAM MMU versions ant\u00e9rieures \u00e0 V2.05",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Camstar Enterprise Platform : une migration vers Opcenter Execution Core 8.2 est requise",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IT LMS, Production Suite, Notifier Server for Windows, PCS neo",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SICAM SGU",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "LOGO! 8 BM (incl. variantes SIPLUS) versions ant\u00e9rieures \u00e0 V1.82.03",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Opcenter RD\u0026L versions ant\u00e9rieures \u00e0 8.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC Runtime Advanced",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SPPA-T3000 APC UPS avec carte NMC AP9630 ou AP9631",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC STEP 7 (TIA Portal) v16 versions ant\u00e9rieures \u00e0 V16 update 2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SPPA-T3000 Application Server et Terminal Server",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC TDC CPU555 versions ant\u00e9rieures \u00e0 V1.1.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Opcenter Execution Discrete versions ant\u00e9rieures \u00e0 v3.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Opcenter Execution Core versions ant\u00e9rieures \u00e0 v8.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-200 SMART CPU versions ant\u00e9rieures \u00e0 V2.5.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Opcenter Quality versions ant\u00e9rieures \u00e0 11.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Opcenter Intelligence",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "LOGO! 8 BM (incl. variantes SIPLUS) versions ant\u00e9rieures \u00e0 V1.81.04",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI Basic Panels premi\u00e8re et seconde g\u00e9n\u00e9ration, Comfort Panels, Mobile Panels de seconde g\u00e9n\u00e9ration (incl. variantes SIPLUS)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC STEP 7 (TIA Portal) v15",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK 840D sl versions ant\u00e9rieures \u00e0 V4.8.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI KTP700F Mobile Arctic",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Opcenter Execution Foundation versions ant\u00e9rieures \u00e0 v3.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOCODE ES et Soft Starter ES",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK 840D sl versions ant\u00e9rieures \u00e0 V4.94",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2020-7584",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7584"
},
{
"name": "CVE-2020-7577",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7577"
},
{
"name": "CVE-2020-7587",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7587"
},
{
"name": "CVE-2020-7576",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7576"
},
{
"name": "CVE-2019-18336",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18336"
},
{
"name": "CVE-2020-10042",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-10042"
},
{
"name": "CVE-2020-7592",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7592"
},
{
"name": "CVE-2020-10043",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-10043"
},
{
"name": "CVE-2020-10045",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-10045"
},
{
"name": "CVE-2020-7578",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7578"
},
{
"name": "CVE-2020-7588",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7588"
},
{
"name": "CVE-2020-10044",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-10044"
},
{
"name": "CVE-2020-10041",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-10041"
},
{
"name": "CVE-2020-7581",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7581"
},
{
"name": "CVE-2020-10039",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-10039"
},
{
"name": "CVE-2020-10038",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-10038"
},
{
"name": "CVE-2020-10040",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-10040"
},
{
"name": "CVE-2020-11896",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-11896"
},
{
"name": "CVE-2020-7593",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7593"
},
{
"name": "CVE-2020-10037",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-10037"
},
{
"name": "CVE-2020-0545",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-0545"
}
],
"initial_release_date": "2020-07-15T00:00:00",
"last_revision_date": "2020-07-15T00:00:00",
"links": [],
"reference": "CERTFR-2020-AVI-439",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2020-07-15T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et une \u00e9l\u00e9vation de privil\u00e8ges.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-589181 du 14 juillet 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-631949 du 14 juillet 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-631949.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-573753 du 14 juillet 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-573753.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-604937 du 14 juillet 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-604937.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-508982 du 10 mars 2020, mis \u00e0 jour le 14 juillet 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508982.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-841348 du 14 juillet 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-364335 du 14 juillet 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-305120 du 14 juillet 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf"
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.