CVE-2020-7546 (GCVE-0-2020-7546)
Vulnerability from cvelistv5
Published
2020-12-01 14:44
Modified
2024-08-04 09:33
Severity ?
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation
Summary
A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage.
Impacted products
Vendor Product Version
n/a EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) Version: EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:33:19.932Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79: Improper Neutralization of Input During Web Page Generation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-12-01T14:44:31",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2020-7546",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79: Improper Neutralization of Input During Web Page Generation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/",
              "refsource": "MISC",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2020-7546",
    "datePublished": "2020-12-01T14:44:31",
    "dateReserved": "2020-01-21T00:00:00",
    "dateUpdated": "2024-08-04T09:33:19.932Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2020-7546\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2020-12-01T15:15:12.563\",\"lastModified\":\"2024-11-21T05:37:21.363\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage.\"},{\"lang\":\"es\",\"value\":\"Una CWE-79: Se presenta una vulnerabilidad Neutralizaci\u00f3n Inapropiada de la Entrada Durante la Generaci\u00f3n de P\u00e1ginas Web en el Software EcoStruxure\u00aa y SmartStruxure\u00aa Power Monitoring and SCADA (v\u00e9ase la notificaci\u00f3n de seguridad para la informaci\u00f3n de la versi\u00f3n) que podr\u00eda permitir a un atacante llevar a cabo acciones en nombre del usuario autorizado cuando se acceder a un p\u00e1gina web afectada\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":5.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:S/C:N/I:P/A:N\",\"baseScore\":3.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":6.8,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_energy_expert:2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CDF7DFC6-6F41-491B-A703-6AB0143FE5B1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:7.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6819EA7A-C803-480F-98DF-44DA144FE488\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:8.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"66E928C4-87C8-4BD6-9131-B7D558330CBA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:9.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0BEB4F4B-0B22-47CA-B173-C06C1A925348\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:power_manager:1.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2FC0093C-00CE-43A8-80EC-0509992E637B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:power_manager:1.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CE9A1DF0-42B8-4123-8276-1D4BED156034\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:power_manager:1.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"54A54A8D-40F5-4E75-A524-B81E487DB274\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:powerscada_expert_with_advanced_reporting_and_dashboards:8.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3CC2CF9D-8D0C-4FD3-94A2-34A63E297B81\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:powerscada_operation_with_advanced_reporting_and_dashboards:9.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DC8F406C-868A-443C-8842-6CFFFF17C236\"}]}]}],\"references\":[{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2020-287-04/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2020-287-04/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…