CVE-2020-5538 (GCVE-0-2020-5538)
Vulnerability from cvelistv5
Published
2020-05-11 04:40
Modified
2024-08-04 08:30
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Improper Access Control
Summary
Improper Access Control in PALLET CONTROL Ver. 6.3 and earlier allows authenticated attackers to execute arbitrary code with the SYSTEM privilege on the computer where PALLET CONTROL is installed via unspecified vectors. PalletControl 7 to 9.1 are not affected by this vulnerability, however under the environment where PLS Management Add-on Module is used, all versions are affected.
References
| URL | Tags | ||
|---|---|---|---|
|
|
|||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| JAL Information Technology Co., Ltd. | PALLET CONTROL |
Version: Ver. 6.3 and earlier |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:30:24.604Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.jalinfotec.co.jp/product/pallet/support/Info/notices.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/jp/JVN61849442/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PALLET CONTROL",
"vendor": "JAL Information Technology Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "Ver. 6.3 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Access Control in PALLET CONTROL Ver. 6.3 and earlier allows authenticated attackers to execute arbitrary code with the SYSTEM privilege on the computer where PALLET CONTROL is installed via unspecified vectors. PalletControl 7 to 9.1 are not affected by this vulnerability, however under the environment where PLS Management Add-on Module is used, all versions are affected."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Improper Access Control",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-05-11T04:40:14",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.jalinfotec.co.jp/product/pallet/support/Info/notices.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/jp/JVN61849442/index.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2020-5538",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PALLET CONTROL",
"version": {
"version_data": [
{
"version_value": "Ver. 6.3 and earlier"
}
]
}
}
]
},
"vendor_name": "JAL Information Technology Co., Ltd."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Access Control in PALLET CONTROL Ver. 6.3 and earlier allows authenticated attackers to execute arbitrary code with the SYSTEM privilege on the computer where PALLET CONTROL is installed via unspecified vectors. PalletControl 7 to 9.1 are not affected by this vulnerability, however under the environment where PLS Management Add-on Module is used, all versions are affected."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.jalinfotec.co.jp/product/pallet/support/Info/notices.html",
"refsource": "MISC",
"url": "https://www.jalinfotec.co.jp/product/pallet/support/Info/notices.html"
},
{
"name": "https://jvn.jp/en/jp/JVN61849442/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/jp/JVN61849442/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2020-5538",
"datePublished": "2020-05-11T04:40:14",
"dateReserved": "2020-01-06T00:00:00",
"dateUpdated": "2024-08-04T08:30:24.604Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2020-5538\",\"sourceIdentifier\":\"vultures@jpcert.or.jp\",\"published\":\"2020-05-11T05:15:11.933\",\"lastModified\":\"2024-11-21T05:34:14.293\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper Access Control in PALLET CONTROL Ver. 6.3 and earlier allows authenticated attackers to execute arbitrary code with the SYSTEM privilege on the computer where PALLET CONTROL is installed via unspecified vectors. PalletControl 7 to 9.1 are not affected by this vulnerability, however under the environment where PLS Management Add-on Module is used, all versions are affected.\"},{\"lang\":\"es\",\"value\":\"Un Control de Acceso Inapropiado en PALLET CONTROL versiones 6.3 y anteriores, permite a atacantes autenticados ejecutar c\u00f3digo arbitrario con el privilegio SYSTEM en la computadora donde se instala PALLET CONTROL por medio de vectores no especificados. PalletControl versiones 7 hasta 9.1 no est\u00e1 afectado por esta vulnerabilidad, sin embargo, bajo el entorno donde PLS Management Add-on Module es usado, todas las versiones est\u00e1n afectadas.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":7.2,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:jalinfotec:pallet_control:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"6.3\",\"matchCriteriaId\":\"27D38602-581D-424C-B62C-3B16C481B721\"}]}]}],\"references\":[{\"url\":\"https://jvn.jp/en/jp/JVN61849442/index.html\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.jalinfotec.co.jp/product/pallet/support/Info/notices.html\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://jvn.jp/en/jp/JVN61849442/index.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.jalinfotec.co.jp/product/pallet/support/Info/notices.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…