Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2020-36475 (GCVE-0-2020-36475)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T17:30:08.223Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0" }, { "tags": [ "x_transferred" ], "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9" }, { "tags": [ "x_transferred" ], "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf" }, { "name": "[debian-lts-announce] 20211123 [SECURITY] [DLA 2826-1] mbedtls security update", "tags": [ "mailing-list", "x_transferred" ], "url": "https://lists.debian.org/debian-lts-announce/2021/11/msg00021.html" }, { "name": "[debian-lts-announce] 20221225 [SECURITY] [DLA 3249-1] mbedtls security update", "tags": [ "mailing-list", "x_transferred" ], "url": "https://lists.debian.org/debian-lts-announce/2022/12/msg00036.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An issue was discovered in Mbed TLS before 2.25.0 (and before 2.16.9 LTS and before 2.7.18 LTS). The calculations performed by mbedtls_mpi_exp_mod are not limited; thus, supplying overly large parameters could lead to denial of service when generating Diffie-Hellman key pairs." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-26T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0" }, { "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9" }, { "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf" }, { "name": "[debian-lts-announce] 20211123 [SECURITY] [DLA 2826-1] mbedtls security update", "tags": [ "mailing-list" ], "url": "https://lists.debian.org/debian-lts-announce/2021/11/msg00021.html" }, { "name": "[debian-lts-announce] 20221225 [SECURITY] [DLA 3249-1] mbedtls security update", "tags": [ "mailing-list" ], "url": "https://lists.debian.org/debian-lts-announce/2022/12/msg00036.html" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-36475", "datePublished": "2021-08-23T00:00:00", "dateReserved": "2021-08-23T00:00:00", "dateUpdated": "2024-08-04T17:30:08.223Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-36475\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2021-08-23T02:15:06.930\",\"lastModified\":\"2024-11-21T05:29:37.603\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue was discovered in Mbed TLS before 2.25.0 (and before 2.16.9 LTS and before 2.7.18 LTS). The calculations performed by mbedtls_mpi_exp_mod are not limited; thus, supplying overly large parameters could lead to denial of service when generating Diffie-Hellman key pairs.\"},{\"lang\":\"es\",\"value\":\"Se ha detectado un problema en Mbed TLS versiones anteriores a 2.25.0 (y versiones anteriores a 2.16.9 LTS y versiones anteriores a 2.7.18 LTS). Los c\u00e1lculos llevado a cabo por la funci\u00f3n mbedtls_mpi_exp_mod no est\u00e1n limitados; por lo tanto, el suministro de par\u00e1metros demasiado grandes podr\u00eda conllevar a una denegaci\u00f3n de servicio cuando se generan pares de claves Diffie-Hellman.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-131\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:arm:mbed_tls:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.7.18\",\"matchCriteriaId\":\"D1399656-491A-428C-B290-5303A59B7C0E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:arm:mbed_tls:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2.8.0\",\"versionEndExcluding\":\"2.16.9\",\"matchCriteriaId\":\"9DD8F7D9-7E6F-4C31-A38C-D4B246F713FF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:arm:mbed_tls:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2.17.0\",\"versionEndExcluding\":\"2.25.0\",\"matchCriteriaId\":\"57294BAA-C692-4C66-96E9-7B653E32D88C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:logo\\\\!_cmr2020_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.2\",\"matchCriteriaId\":\"FE9FB0B2-71ED-4208-B908-1C78CB15E372\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:logo\\\\!_cmr2020:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E8E5F42B-63E3-4B2D-A03F-983F51EE0648\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:logo\\\\!_cmr2040_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.2\",\"matchCriteriaId\":\"ECD83A4C-DB7F-425C-882C-0DC809AD4A21\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:logo\\\\!_cmr2040:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6ED47A12-5637-40E2-BE39-B76B789C0DFD\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_rtu3031c_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"64954FA1-0F30-4D1D-8218-C3BA84C5AAF0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_rtu3031c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"48F0595C-286F-4EB1-8C25-D20FB92A95A0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_rtu3041c_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0307A2DD-B616-4551-8C31-0B0EBE4A4B12\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_rtu3041c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E57561E2-DC49-4D11-BBF1-40E7B14A6873\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_rtu3030c_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"61C3C191-5CEE-46F7-9231-BD2E246130E1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_rtu3030c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6A66DD04-4C58-45D8-A8C5-6817B05DBA14\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_rtu3000c_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6B3325EA-59B3-4BB6-923D-0D89CB8AAC25\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_rtu3000c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D2E902CE-D319-4FC9-BC9B-7D8DB83FAD9B\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DEECE5FC-CACF-4496-A3E7-164736409252\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"07B237A9-69A3-4A9C-9DA0-4E06BD37AE73\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9\",\"source\":\"cve@mitre.org\",\"tags\":[\"Release Notes\",\"Third Party Advisory\"]},{\"url\":\"https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0\",\"source\":\"cve@mitre.org\",\"tags\":[\"Release Notes\",\"Third Party Advisory\"]},{\"url\":\"https://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18\",\"source\":\"cve@mitre.org\",\"tags\":[\"Release Notes\",\"Third Party Advisory\"]},{\"url\":\"https://lists.debian.org/debian-lts-announce/2021/11/msg00021.html\",\"source\":\"cve@mitre.org\",\"tags\":[\"Mailing List\",\"Third Party Advisory\"]},{\"url\":\"https://lists.debian.org/debian-lts-announce/2022/12/msg00036.html\",\"source\":\"cve@mitre.org\",\"tags\":[\"Mailing List\",\"Third Party Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Release Notes\",\"Third Party Advisory\"]},{\"url\":\"https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Release Notes\",\"Third Party Advisory\"]},{\"url\":\"https://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Release Notes\",\"Third Party Advisory\"]},{\"url\":\"https://lists.debian.org/debian-lts-announce/2021/11/msg00021.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mailing List\",\"Third Party Advisory\"]},{\"url\":\"https://lists.debian.org/debian-lts-announce/2022/12/msg00036.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mailing List\",\"Third Party Advisory\"]}]}}" } }
fkie_cve-2020-36475
Vulnerability from fkie_nvd
URL | Tags | ||
---|---|---|---|
cve@mitre.org | https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf | Patch, Third Party Advisory | |
cve@mitre.org | https://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9 | Release Notes, Third Party Advisory | |
cve@mitre.org | https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0 | Release Notes, Third Party Advisory | |
cve@mitre.org | https://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18 | Release Notes, Third Party Advisory | |
cve@mitre.org | https://lists.debian.org/debian-lts-announce/2021/11/msg00021.html | Mailing List, Third Party Advisory | |
cve@mitre.org | https://lists.debian.org/debian-lts-announce/2022/12/msg00036.html | Mailing List, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf | Patch, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9 | Release Notes, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0 | Release Notes, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18 | Release Notes, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://lists.debian.org/debian-lts-announce/2021/11/msg00021.html | Mailing List, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://lists.debian.org/debian-lts-announce/2022/12/msg00036.html | Mailing List, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
arm | mbed_tls | * | |
arm | mbed_tls | * | |
arm | mbed_tls | * | |
siemens | logo\!_cmr2020_firmware | * | |
siemens | logo\!_cmr2020 | - | |
siemens | logo\!_cmr2040_firmware | * | |
siemens | logo\!_cmr2040 | - | |
siemens | simatic_rtu3031c_firmware | * | |
siemens | simatic_rtu3031c | - | |
siemens | simatic_rtu3041c_firmware | * | |
siemens | simatic_rtu3041c | - | |
siemens | simatic_rtu3030c_firmware | * | |
siemens | simatic_rtu3030c | - | |
siemens | simatic_rtu3000c_firmware | * | |
siemens | simatic_rtu3000c | - | |
debian | debian_linux | 9.0 | |
debian | debian_linux | 10.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:arm:mbed_tls:*:*:*:*:*:*:*:*", "matchCriteriaId": "D1399656-491A-428C-B290-5303A59B7C0E", "versionEndExcluding": "2.7.18", "vulnerable": true }, { "criteria": "cpe:2.3:a:arm:mbed_tls:*:*:*:*:*:*:*:*", "matchCriteriaId": "9DD8F7D9-7E6F-4C31-A38C-D4B246F713FF", "versionEndExcluding": "2.16.9", "versionStartIncluding": "2.8.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:arm:mbed_tls:*:*:*:*:*:*:*:*", "matchCriteriaId": "57294BAA-C692-4C66-96E9-7B653E32D88C", "versionEndExcluding": "2.25.0", "versionStartIncluding": "2.17.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:logo\\!_cmr2020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE9FB0B2-71ED-4208-B908-1C78CB15E372", "versionEndExcluding": "2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:logo\\!_cmr2020:-:*:*:*:*:*:*:*", "matchCriteriaId": "E8E5F42B-63E3-4B2D-A03F-983F51EE0648", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:logo\\!_cmr2040_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ECD83A4C-DB7F-425C-882C-0DC809AD4A21", "versionEndExcluding": "2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:logo\\!_cmr2040:-:*:*:*:*:*:*:*", "matchCriteriaId": "6ED47A12-5637-40E2-BE39-B76B789C0DFD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rtu3031c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64954FA1-0F30-4D1D-8218-C3BA84C5AAF0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rtu3031c:-:*:*:*:*:*:*:*", "matchCriteriaId": "48F0595C-286F-4EB1-8C25-D20FB92A95A0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rtu3041c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0307A2DD-B616-4551-8C31-0B0EBE4A4B12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rtu3041c:-:*:*:*:*:*:*:*", "matchCriteriaId": "E57561E2-DC49-4D11-BBF1-40E7B14A6873", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rtu3030c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61C3C191-5CEE-46F7-9231-BD2E246130E1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rtu3030c:-:*:*:*:*:*:*:*", "matchCriteriaId": "6A66DD04-4C58-45D8-A8C5-6817B05DBA14", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rtu3000c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6B3325EA-59B3-4BB6-923D-0D89CB8AAC25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rtu3000c:-:*:*:*:*:*:*:*", "matchCriteriaId": "D2E902CE-D319-4FC9-BC9B-7D8DB83FAD9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*", "matchCriteriaId": "DEECE5FC-CACF-4496-A3E7-164736409252", "vulnerable": true }, { "criteria": "cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*", "matchCriteriaId": "07B237A9-69A3-4A9C-9DA0-4E06BD37AE73", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered in Mbed TLS before 2.25.0 (and before 2.16.9 LTS and before 2.7.18 LTS). The calculations performed by mbedtls_mpi_exp_mod are not limited; thus, supplying overly large parameters could lead to denial of service when generating Diffie-Hellman key pairs." }, { "lang": "es", "value": "Se ha detectado un problema en Mbed TLS versiones anteriores a 2.25.0 (y versiones anteriores a 2.16.9 LTS y versiones anteriores a 2.7.18 LTS). Los c\u00e1lculos llevado a cabo por la funci\u00f3n mbedtls_mpi_exp_mod no est\u00e1n limitados; por lo tanto, el suministro de par\u00e1metros demasiado grandes podr\u00eda conllevar a una denegaci\u00f3n de servicio cuando se generan pares de claves Diffie-Hellman." } ], "id": "CVE-2020-36475", "lastModified": "2024-11-21T05:29:37.603", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-08-23T02:15:06.930", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf" }, { "source": "cve@mitre.org", "tags": [ "Release Notes", "Third Party Advisory" ], "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9" }, { "source": "cve@mitre.org", "tags": [ "Release Notes", "Third Party Advisory" ], "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0" }, { "source": "cve@mitre.org", "tags": [ "Release Notes", "Third Party Advisory" ], "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18" }, { "source": "cve@mitre.org", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "https://lists.debian.org/debian-lts-announce/2021/11/msg00021.html" }, { "source": "cve@mitre.org", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "https://lists.debian.org/debian-lts-announce/2022/12/msg00036.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Release Notes", "Third Party Advisory" ], "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Release Notes", "Third Party Advisory" ], "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Release Notes", "Third Party Advisory" ], "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "https://lists.debian.org/debian-lts-announce/2021/11/msg00021.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "https://lists.debian.org/debian-lts-announce/2022/12/msg00036.html" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-131" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
CERTFR-2021-AVI-706
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneVendor | Product | Description | ||
---|---|---|---|---|
Siemens | N/A | Industrial Edge Management versions antérieures à V1.3 | ||
Siemens | N/A | SIMATIC RF350M toutes versions | ||
Siemens | N/A | SIPROTEC 5 relays with CPU variants CP050 versions antérieures à V8.80 | ||
Siemens | N/A | SCALANCE X204-2TS versions antérieures à V5.2.5 | ||
Siemens | N/A | SCALANCE X306-1LD FE toutes versions | ||
Siemens | N/A | TALON TC Modular (BACnet) versions antérieures à V3.5.3 | ||
Siemens | N/A | SIMATIC CP 443-1 Advanced (incl. SIPLUS variants) toutes versions | ||
Siemens | N/A | RUGGEDCOM ROX RX1501 versions antérieures à V2.14.1 | ||
Siemens | N/A | SCALANCE X201-3P IRT PRO toutes versions | ||
Siemens | N/A | APOGEE MBC (PPC) (P2 Ethernet) toutes versions >= V2.6.3 | ||
Siemens | N/A | Teamcenter V12.4 versions antérieures à V12.4.0.8 | ||
Siemens | N/A | SCALANCE X302-7 EEC toutes versions | ||
Siemens | N/A | Desigo CC V4.0 toutes versions | ||
Siemens | N/A | SCALANCE X304-2FE toutes versions | ||
Siemens | N/A | APOGEE PXC Modular (P2 Ethernet) toutes versions >= V2.8 | ||
Siemens | N/A | APOGEE MEC (PPC) (P2 Ethernet) toutes versions >= V2.6.3 | ||
Siemens | N/A | SINEC NMS versions antérieures à V1.0 SP1 | ||
Siemens | N/A | SCALANCE X202-2 IRT toutes versions | ||
Siemens | N/A | SIMATIC CP 1543-1 (incl. SIPLUS variants) versions antérieures à V3.0 | ||
Siemens | N/A | SIPROTEC 5 relays with CPU variants CP300 versions antérieures à V8.80 | ||
Siemens | N/A | SCALANCE X308-2LD toutes versions | ||
Siemens | N/A | SCALANCE X212-2 (incl. SIPLUS NET variant) versions antérieures à V5.2.5 | ||
Siemens | N/A | RUGGEDCOM ROX RX1524 versions antérieures à V2.14.1 | ||
Siemens | N/A | SCALANCE XR324-4M PoE toutes versions | ||
Siemens | N/A | Desigo CC toutes versions with OIS Extension Module | ||
Siemens | N/A | Teamcenter Active Workspace V4.3 versions antérieures à V4.3.10 | ||
Siemens | N/A | SCALANCE X310 toutes versions | ||
Siemens | N/A | RUGGEDCOM ROX RX5000 versions antérieures à V2.14.1 | ||
Siemens | N/A | SCALANCE X308-2LH+ toutes versions | ||
Siemens | N/A | NX 1980 Series versions antérieures à V1984 | ||
Siemens | N/A | Simcenter STAR-CCM+ Viewer versions antérieures à V2021.2.1 | ||
Siemens | N/A | SCALANCE X204 IRT PRO toutes versions | ||
Siemens | N/A | SCALANCE XR324-12M toutes versions | ||
Siemens | N/A | Teamcenter Active Workspace V5.2 versions antérieures à V5.2.1 | ||
Siemens | N/A | SCALANCE X308-2M toutes versions | ||
Siemens | N/A | Siveillance Control toutes versions with OIS running on Debian 9 or earlier | ||
Siemens | N/A | RUGGEDCOM ROX RX1400 versions antérieures à V2.14.1 | ||
Siemens | N/A | SCALANCE X408-2 toutes versions | ||
Siemens | N/A | APOGEE PXC Compact (P2 Ethernet) toutes versions >= V2.8 | ||
Siemens | N/A | SCALANCE X308-2M TS toutes versions | ||
Siemens | N/A | Operation Scheduler toutes versions with OIS running on Debian 9 or earlier | ||
Siemens | N/A | SCALANCE XR324-4M PoE TS toutes versions | ||
Siemens | N/A | Desigo CC V4.1 toutes versions | ||
Siemens | N/A | Desigo CC Compact V4.0 toutes versions | ||
Siemens | N/A | RUGGEDCOM ROX RX1512 versions antérieures à V2.14.1 | ||
Siemens | N/A | Simcenter Femap V2020.2 toutes versions | ||
Siemens | N/A | SCALANCE XF204 IRT toutes versions | ||
Siemens | N/A | Desigo CC V4.2 toutes versions | ||
Siemens | N/A | Teamcenter V13.0 versions antérieures à V13.0.0.7 | ||
Siemens | N/A | SCALANCE X201-3P IRT toutes versions | ||
Siemens | N/A | SCALANCE XF202-2P IRT toutes versions | ||
Siemens | N/A | SCALANCE XF204-2BA IRT toutes versions | ||
Siemens | N/A | SCALANCE XF206-1 versions antérieures à V5.2.5 | ||
Siemens | N/A | SCALANCE XF201-3P IRT toutes versions | ||
Siemens | N/A | SCALANCE X307-3LD toutes versions | ||
Siemens | N/A | Simcenter Femap V2021.1 toutes versions | ||
Siemens | N/A | SCALANCE X307-3 toutes versions | ||
Siemens | N/A | SIPROTEC 5 relays with CPU variants CP200 toutes versions | ||
Siemens | N/A | SIMATIC RF650M toutes versions | ||
Siemens | N/A | Siveillance Control Pro toutes versions | ||
Siemens | N/A | SCALANCE X310FE toutes versions | ||
Siemens | N/A | Cerberus DMS V5.0 versions antérieures à v5.0 QU1 | ||
Siemens | N/A | SINEMA Server versions antérieures à V14 SP3 | ||
Siemens | N/A | TALON TC Compact (BACnet) versions antérieures à V3.5.3 | ||
Siemens | N/A | SCALANCE X202-2P IRT (incl. SIPLUS NET variant) toutes versions | ||
Siemens | N/A | APOGEE PXC Compact (BACnet) versions antérieures à V3.5.3 | ||
Siemens | N/A | SCALANCE X224 versions antérieures à V5.2.5 | ||
Siemens | N/A | SIMATIC CP 343-1 Lean (incl. SIPLUS variants) toutes versions | ||
Siemens | N/A | SIMATIC CP 343-1 (incl. SIPLUS variants) toutes versions | ||
Siemens | N/A | SCALANCE XR324-12M TS toutes versions | ||
Siemens | N/A | Cerberus DMS V4.2 toutes versions | ||
Siemens | N/A | SCALANCE X320-1-2LD FE toutes versions | ||
Siemens | N/A | SIMATIC RTU 3000 family toutes versions | ||
Siemens | N/A | SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) toutes versions | ||
Siemens | N/A | RUGGEDCOM ROX MX5000 versions antérieures à V2.14.1 | ||
Siemens | N/A | Teamcenter V13.1 versions antérieures à V13.1.0.5 | ||
Siemens | N/A | SIMATIC CP 1545-1 toutes versions | ||
Siemens | N/A | Desigo CC Compact V5.0 versions antérieures à V5.0 QU1 | ||
Siemens | N/A | SCALANCE XF208 versions antérieures à V5.2.5 | ||
Siemens | N/A | SCALANCE X308-2LH toutes versions | ||
Siemens | N/A | SCALANCE X204-2 (incl. SIPLUS NET variant) versions antérieures à V5.2.5 | ||
Siemens | N/A | RUGGEDCOM ROX RX1511 versions antérieures à V2.14.1 | ||
Siemens | N/A | RUGGEDCOM ROX RX1500 versions antérieures à V2.14.1 | ||
Siemens | N/A | SCALANCE X200-4P IRT toutes versions | ||
Siemens | N/A | Teamcenter V13.2 versions antérieures à 13.2.0.2 | ||
Siemens | N/A | SCALANCE XR324-4M EEC toutes versions | ||
Siemens | N/A | SCALANCE XF204 versions antérieures à V5.2.5 | ||
Siemens | N/A | Desigo CC V5.0 versions antérieures à V5.0 QU1 | ||
Siemens | N/A | SCALANCE X307-2 EEC toutes versions | ||
Siemens | N/A | SCALANCE X320-1 FE toutes versions | ||
Siemens | N/A | SCALANCE X204-2FM versions antérieures à V5.2.5 | ||
Siemens | N/A | GMA-Manager toutes versions with OIS running on Debian 9 or earlier | ||
Siemens | N/A | SIMATIC CP 443-1 (incl. SIPLUS variants) toutes versions | ||
Siemens | N/A | SCALANCE X202-2P IRT PRO toutes versions | ||
Siemens | N/A | Cerberus DMS V4.0 toutes versions | ||
Siemens | N/A | SINEMA Remote Connect Server versions antérieures à V3.0 SP2 | ||
Siemens | N/A | LOGO! CMR2020 versions antérieures à V2.2 | ||
Siemens | N/A | Desigo CC Compact V4.1 toutes versions | ||
Siemens | N/A | APOGEE PXC Modular (BACnet) versions antérieures à V3.5.3 | ||
Siemens | N/A | SCALANCE XF204-2 (incl. SIPLUS NET variant) versions antérieures à V5.2.5 | ||
Siemens | N/A | SCALANCE X204 IRT toutes versions | ||
Siemens | N/A | SIMATIC CP 343-1 ERPC toutes versions | ||
Siemens | N/A | RUGGEDCOM ROX RX1510 versions antérieures à V2.14.1 | ||
Siemens | N/A | Cerberus DMS V4.1 toutes versions | ||
Siemens | N/A | Teamcenter Active Workspace V5.0 versions antérieures à V5.0.8 | ||
Siemens | N/A | SCALANCE X204-2LD TS versions antérieures à V5.2.5 | ||
Siemens | N/A | SCALANCE X204-2LD (incl. SIPLUS NET variant) versions antérieures à V5.2.5 | ||
Siemens | N/A | SIPROTEC 5 relays with CPU variants CP100 versions antérieures à V8.80 | ||
Siemens | N/A | LOGO! CMR2040 versions antérieures à V2.2 | ||
Siemens | N/A | Desigo CC Compact V4.2 toutes versions | ||
Siemens | N/A | RUGGEDCOM ROX RX1536 versions antérieures à V2.14.1 | ||
Siemens | N/A | SCALANCE X208PRO versions antérieures à V5.2.5 | ||
Siemens | N/A | SCALANCE X308-2M PoE toutes versions | ||
Siemens | N/A | SCALANCE X206-1LD versions antérieures à V5.2.5 | ||
Siemens | N/A | SCALANCE X208 (incl. SIPLUS NET variant) versions antérieures à V5.2.5 | ||
Siemens | N/A | SCALANCE X216 versions antérieures à V5.2.5 | ||
Siemens | N/A | SCALANCE X206-1 versions antérieures à V5.2.5 | ||
Siemens | N/A | SCALANCE X212-2LD versions antérieures à V5.2.5 | ||
Siemens | N/A | Teamcenter Active Workspace V5.1 versions antérieures à V5.1.5 | ||
Siemens | N/A | SCALANCE X308-2 (incl. SIPLUS NET variant) toutes versions |
Title | Publication Time | Tags | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "Industrial Edge Management versions ant\u00e9rieures \u00e0 V1.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC RF350M toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPROTEC 5 relays with CPU variants CP050 versions ant\u00e9rieures \u00e0 V8.80", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X204-2TS versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X306-1LD FE toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "TALON TC Modular (BACnet) versions ant\u00e9rieures \u00e0 V3.5.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROX RX1501 versions ant\u00e9rieures \u00e0 V2.14.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X201-3P IRT PRO toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE MBC (PPC) (P2 Ethernet) toutes versions \u003e= V2.6.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter V12.4 versions ant\u00e9rieures \u00e0 V12.4.0.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X302-7 EEC toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Desigo CC V4.0 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X304-2FE toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE PXC Modular (P2 Ethernet) toutes versions \u003e= V2.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE MEC (PPC) (P2 Ethernet) toutes versions \u003e= V2.6.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINEC NMS versions ant\u00e9rieures \u00e0 V1.0 SP1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X202-2 IRT toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC CP 1543-1 (incl. SIPLUS variants) versions ant\u00e9rieures \u00e0 V3.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPROTEC 5 relays with CPU variants CP300 versions ant\u00e9rieures \u00e0 V8.80", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X308-2LD toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X212-2 (incl. SIPLUS NET variant) versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROX RX1524 versions ant\u00e9rieures \u00e0 V2.14.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XR324-4M PoE toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Desigo CC toutes versions with OIS Extension Module", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter Active Workspace V4.3 versions ant\u00e9rieures \u00e0 V4.3.10", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X310 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROX RX5000 versions ant\u00e9rieures \u00e0 V2.14.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X308-2LH+ toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "NX 1980 Series versions ant\u00e9rieures \u00e0 V1984", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Simcenter STAR-CCM+ Viewer versions ant\u00e9rieures \u00e0 V2021.2.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X204 IRT PRO toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XR324-12M toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter Active Workspace V5.2 versions ant\u00e9rieures \u00e0 V5.2.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X308-2M toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Siveillance Control toutes versions with OIS running on Debian 9 or earlier", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROX RX1400 versions ant\u00e9rieures \u00e0 V2.14.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X408-2 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE PXC Compact (P2 Ethernet) toutes versions \u003e= V2.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X308-2M TS toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Operation Scheduler toutes versions with OIS running on Debian 9 or earlier", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XR324-4M PoE TS toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Desigo CC V4.1 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Desigo CC Compact V4.0 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROX RX1512 versions ant\u00e9rieures \u00e0 V2.14.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Simcenter Femap V2020.2 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF204 IRT toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Desigo CC V4.2 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter V13.0 versions ant\u00e9rieures \u00e0 V13.0.0.7", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X201-3P IRT toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF202-2P IRT toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF204-2BA IRT toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF206-1 versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF201-3P IRT toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X307-3LD toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Simcenter Femap V2021.1 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X307-3 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPROTEC 5 relays with CPU variants CP200 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC RF650M toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Siveillance Control Pro toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X310FE toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Cerberus DMS V5.0 versions ant\u00e9rieures \u00e0 v5.0 QU1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINEMA Server versions ant\u00e9rieures \u00e0 V14 SP3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "TALON TC Compact (BACnet) versions ant\u00e9rieures \u00e0 V3.5.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X202-2P IRT (incl. SIPLUS NET variant) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE PXC Compact (BACnet) versions ant\u00e9rieures \u00e0 V3.5.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X224 versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC CP 343-1 (incl. SIPLUS variants) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XR324-12M TS toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Cerberus DMS V4.2 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X320-1-2LD FE toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC RTU 3000 family toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROX MX5000 versions ant\u00e9rieures \u00e0 V2.14.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter V13.1 versions ant\u00e9rieures \u00e0 V13.1.0.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC CP 1545-1 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Desigo CC Compact V5.0 versions ant\u00e9rieures \u00e0 V5.0 QU1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF208 versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X308-2LH toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X204-2 (incl. SIPLUS NET variant) versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROX RX1511 versions ant\u00e9rieures \u00e0 V2.14.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROX RX1500 versions ant\u00e9rieures \u00e0 V2.14.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X200-4P IRT toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter V13.2 versions ant\u00e9rieures \u00e0 13.2.0.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XR324-4M EEC toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF204 versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Desigo CC V5.0 versions ant\u00e9rieures \u00e0 V5.0 QU1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X307-2 EEC toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X320-1 FE toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X204-2FM versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "GMA-Manager toutes versions with OIS running on Debian 9 or earlier", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC CP 443-1 (incl. SIPLUS variants) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X202-2P IRT PRO toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Cerberus DMS V4.0 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINEMA Remote Connect Server versions ant\u00e9rieures \u00e0 V3.0 SP2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "LOGO! CMR2020 versions ant\u00e9rieures \u00e0 V2.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Desigo CC Compact V4.1 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE PXC Modular (BACnet) versions ant\u00e9rieures \u00e0 V3.5.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF204-2 (incl. SIPLUS NET variant) versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X204 IRT toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC CP 343-1 ERPC toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROX RX1510 versions ant\u00e9rieures \u00e0 V2.14.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Cerberus DMS V4.1 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter Active Workspace V5.0 versions ant\u00e9rieures \u00e0 V5.0.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X204-2LD TS versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X204-2LD (incl. SIPLUS NET variant) versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPROTEC 5 relays with CPU variants CP100 versions ant\u00e9rieures \u00e0 V8.80", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "LOGO! CMR2040 versions ant\u00e9rieures \u00e0 V2.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Desigo CC Compact V4.2 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROX RX1536 versions ant\u00e9rieures \u00e0 V2.14.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X208PRO versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X308-2M PoE toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X206-1LD versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X208 (incl. SIPLUS NET variant) versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X216 versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X206-1 versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X212-2LD versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter Active Workspace V5.1 versions ant\u00e9rieures \u00e0 V5.1.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X308-2 (incl. SIPLUS NET variant) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2021-37186", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37186" }, { "name": "CVE-2021-37190", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37190" }, { "name": "CVE-2021-40356", "url": "https://www.cve.org/CVERecord?id=CVE-2021-40356" }, { "name": "CVE-2021-33716", "url": "https://www.cve.org/CVERecord?id=CVE-2021-33716" }, { "name": "CVE-2021-37191", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37191" }, { "name": "CVE-2020-36478", "url": "https://www.cve.org/CVERecord?id=CVE-2020-36478" }, { "name": "CVE-2021-37193", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37193" }, { "name": "CVE-2020-7461", "url": "https://www.cve.org/CVERecord?id=CVE-2020-7461" }, { "name": "CVE-2021-40354", "url": "https://www.cve.org/CVERecord?id=CVE-2021-40354" }, { "name": "CVE-2021-40355", "url": "https://www.cve.org/CVERecord?id=CVE-2021-40355" }, { "name": "CVE-2016-10011", "url": "https://www.cve.org/CVERecord?id=CVE-2016-10011" }, { "name": "CVE-2021-37201", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37201" }, { "name": "CVE-2021-25665", "url": "https://www.cve.org/CVERecord?id=CVE-2021-25665" }, { "name": "CVE-2021-37202", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37202" }, { "name": "CVE-2021-33737", "url": "https://www.cve.org/CVERecord?id=CVE-2021-33737" }, { "name": "CVE-2020-36475", "url": "https://www.cve.org/CVERecord?id=CVE-2020-36475" }, { "name": "CVE-2016-10708", "url": "https://www.cve.org/CVERecord?id=CVE-2016-10708" }, { "name": "CVE-2021-37175", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37175" }, { "name": "CVE-2021-37174", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37174" }, { "name": "CVE-2021-40357", "url": "https://www.cve.org/CVERecord?id=CVE-2021-40357" }, { "name": "CVE-2021-33720", "url": "https://www.cve.org/CVERecord?id=CVE-2021-33720" }, { "name": "CVE-2021-37203", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37203" }, { "name": "CVE-2021-37183", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37183" }, { "name": "CVE-2021-37184", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37184" }, { "name": "CVE-2021-37177", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37177" }, { "name": "CVE-2021-37173", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37173" }, { "name": "CVE-2021-37200", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37200" }, { "name": "CVE-2021-33719", "url": "https://www.cve.org/CVERecord?id=CVE-2021-33719" }, { "name": "CVE-2021-37181", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37181" }, { "name": "CVE-2021-31891", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31891" }, { "name": "CVE-2021-37192", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37192" }, { "name": "CVE-2021-37206", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37206" }, { "name": "CVE-2021-37176", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37176" }, { "name": "CVE-2021-27391", "url": "https://www.cve.org/CVERecord?id=CVE-2021-27391" }, { "name": "CVE-2019-10941", "url": "https://www.cve.org/CVERecord?id=CVE-2019-10941" } ], "initial_release_date": "2021-09-15T00:00:00", "last_revision_date": "2021-09-15T00:00:00", "links": [], "reference": "CERTFR-2021-AVI-706", "revisions": [ { "description": "Version initiale", "revision_date": "2021-09-15T00:00:00.000000" } ], "risks": [ { "description": "D\u00e9ni de service \u00e0 distance" }, { "description": "Ex\u00e9cution de code arbitraire \u00e0 distance" }, { "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es" }, { "description": "Contournement de la politique de s\u00e9curit\u00e9" }, { "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es" }, { "description": "\u00c9l\u00e9vation de privil\u00e8ges" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-847986 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-847986.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-549234 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549234.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-208530 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-288459 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-288459.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-987403 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-987403.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-535380 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-535380.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-334944 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-334944.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-676336 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-676336.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-997732 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-997732.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-835377 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-835377.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-109294 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-109294.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-453715 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-453715.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-692317 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-692317.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-756638 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-316383 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-316383.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-330339 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-330339.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-500748 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-500748.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-535997 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-535997.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-150692 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-150692.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-413407 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413407.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-944498 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944498.pdf" } ] }
ICSA-21-257-20
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker with access to any of the interfaces of an affected device to impact the availability or to communicate with invalid certificates.", "title": "Risk evaluation" }, { "category": "other", "text": "Critical Manufacturing", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-21-257-20 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-257-20.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-257-20 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-257-20" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens LOGO! CMR and SIMATIC RTU 3000", "tracking": { "current_release_date": "2021-09-14T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-257-20", "initial_release_date": "2021-09-14T00:00:00.000000Z", "revision_history": [ { "date": "2021-09-14T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-257-20 Siemens LOGO! CMR and SIMATIC RTU 3000" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 2.2", "product": { "name": "LOGO! CMR2040: all versions prior to v2.2", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "LOGO! CMR2040" }, { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "SIMATIC RTU 3000 family: all versions", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SIMATIC RTU 3000 family" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 2.2", "product": { "name": "LOGO! CMR2020: all versions prior to v2.2", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "LOGO! CMR2020" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2020-36475", "cwe": { "id": "CWE-131", "name": "Incorrect Calculation of Buffer Size" }, "notes": [ { "category": "summary", "text": "The calculations performed in the third-party component Mbed TLS are not limited. Supplying overly large parameters could lead to denial-of-service condition when generating Diffie-Hellman key pairs.CVE-2020-36475 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-36475" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "For LOGO! CMR2020, Siemens recommends affected users update to v2.2 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109800267/" }, { "category": "vendor_fix", "details": "For LOGO! CMR2040, Siemens recommends affected users update to v2.2 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109800267/" }, { "category": "vendor_fix", "details": "For the SIMATIC RTU 3000 family, Siemens recommends affected users use the certificate projection feature to pin the valid certificates of external servers providing services to the RTU/CMR devices. Refer to the product manual for further information.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2020-36478", "cwe": { "id": "CWE-295", "name": "Improper Certificate Validation" }, "notes": [ { "category": "summary", "text": "The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code.CVE-2020-36478 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-36478" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "For LOGO! CMR2020, Siemens recommends affected users update to v2.2 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109800267/" }, { "category": "vendor_fix", "details": "For LOGO! CMR2040, Siemens recommends affected users update to v2.2 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109800267/" }, { "category": "vendor_fix", "details": "For the SIMATIC RTU 3000 family, Siemens recommends affected users use the certificate projection feature to pin the valid certificates of external servers providing services to the RTU/CMR devices. Refer to the product manual for further information.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] } ] }
icsa-21-257-20
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker with access to any of the interfaces of an affected device to impact the availability or to communicate with invalid certificates.", "title": "Risk evaluation" }, { "category": "other", "text": "Critical Manufacturing", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-21-257-20 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-257-20.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-257-20 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-257-20" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens LOGO! CMR and SIMATIC RTU 3000", "tracking": { "current_release_date": "2021-09-14T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-257-20", "initial_release_date": "2021-09-14T00:00:00.000000Z", "revision_history": [ { "date": "2021-09-14T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-257-20 Siemens LOGO! CMR and SIMATIC RTU 3000" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 2.2", "product": { "name": "LOGO! CMR2040: all versions prior to v2.2", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "LOGO! CMR2040" }, { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "SIMATIC RTU 3000 family: all versions", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SIMATIC RTU 3000 family" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 2.2", "product": { "name": "LOGO! CMR2020: all versions prior to v2.2", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "LOGO! CMR2020" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2020-36475", "cwe": { "id": "CWE-131", "name": "Incorrect Calculation of Buffer Size" }, "notes": [ { "category": "summary", "text": "The calculations performed in the third-party component Mbed TLS are not limited. Supplying overly large parameters could lead to denial-of-service condition when generating Diffie-Hellman key pairs.CVE-2020-36475 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-36475" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "For LOGO! CMR2020, Siemens recommends affected users update to v2.2 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109800267/" }, { "category": "vendor_fix", "details": "For LOGO! CMR2040, Siemens recommends affected users update to v2.2 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109800267/" }, { "category": "vendor_fix", "details": "For the SIMATIC RTU 3000 family, Siemens recommends affected users use the certificate projection feature to pin the valid certificates of external servers providing services to the RTU/CMR devices. Refer to the product manual for further information.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2020-36478", "cwe": { "id": "CWE-295", "name": "Improper Certificate Validation" }, "notes": [ { "category": "summary", "text": "The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code.CVE-2020-36478 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-36478" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "For LOGO! CMR2020, Siemens recommends affected users update to v2.2 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109800267/" }, { "category": "vendor_fix", "details": "For LOGO! CMR2040, Siemens recommends affected users update to v2.2 or later.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109800267/" }, { "category": "vendor_fix", "details": "For the SIMATIC RTU 3000 family, Siemens recommends affected users use the certificate projection feature to pin the valid certificates of external servers providing services to the RTU/CMR devices. Refer to the product manual for further information.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] } ] }
ghsa-7qm6-rr75-xc68
Vulnerability from github
An issue was discovered in Mbed TLS before 2.25.0 (and before 2.16.9 LTS and before 2.7.18 LTS). The calculations performed by mbedtls_mpi_exp_mod are not limited; thus, supplying overly large parameters could lead to denial of service when generating Diffie-Hellman key pairs.
{ "affected": [], "aliases": [ "CVE-2020-36475" ], "database_specific": { "cwe_ids": [ "CWE-131" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2021-08-23T02:15:00Z", "severity": "HIGH" }, "details": "An issue was discovered in Mbed TLS before 2.25.0 (and before 2.16.9 LTS and before 2.7.18 LTS). The calculations performed by mbedtls_mpi_exp_mod are not limited; thus, supplying overly large parameters could lead to denial of service when generating Diffie-Hellman key pairs.", "id": "GHSA-7qm6-rr75-xc68", "modified": "2022-12-26T03:30:21Z", "published": "2022-05-24T19:11:59Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2020-36475" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf" }, { "type": "WEB", "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9" }, { "type": "WEB", "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0" }, { "type": "WEB", "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18" }, { "type": "WEB", "url": "https://lists.debian.org/debian-lts-announce/2021/11/msg00021.html" }, { "type": "WEB", "url": "https://lists.debian.org/debian-lts-announce/2022/12/msg00036.html" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "type": "CVSS_V3" } ] }
gsd-2020-36475
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2020-36475", "description": "An issue was discovered in Mbed TLS before 2.25.0 (and before 2.16.9 LTS and before 2.7.18 LTS). The calculations performed by mbedtls_mpi_exp_mod are not limited; thus, supplying overly large parameters could lead to denial of service when generating Diffie-Hellman key pairs.", "id": "GSD-2020-36475", "references": [ "https://www.suse.com/security/cve/CVE-2020-36475.html" ] }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2020-36475" ], "details": "An issue was discovered in Mbed TLS before 2.25.0 (and before 2.16.9 LTS and before 2.7.18 LTS). The calculations performed by mbedtls_mpi_exp_mod are not limited; thus, supplying overly large parameters could lead to denial of service when generating Diffie-Hellman key pairs.", "id": "GSD-2020-36475", "modified": "2023-12-13T01:21:55.984959Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-36475", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_affected": "?", "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered in Mbed TLS before 2.25.0 (and before 2.16.9 LTS and before 2.7.18 LTS). The calculations performed by mbedtls_mpi_exp_mod are not limited; thus, supplying overly large parameters could lead to denial of service when generating Diffie-Hellman key pairs." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0", "refsource": "MISC", "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0" }, { "name": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9", "refsource": "MISC", "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9" }, { "name": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18", "refsource": "MISC", "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18" }, { "name": "https://lists.debian.org/debian-lts-announce/2022/12/msg00036.html", "refsource": "MISC", "url": "https://lists.debian.org/debian-lts-announce/2022/12/msg00036.html" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf" }, { "name": "https://lists.debian.org/debian-lts-announce/2021/11/msg00021.html", "refsource": "MISC", "url": "https://lists.debian.org/debian-lts-announce/2021/11/msg00021.html" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:arm:mbed_tls:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.25.0", "versionStartIncluding": "2.17.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:arm:mbed_tls:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.16.9", "versionStartIncluding": "2.8.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:arm:mbed_tls:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.7.18", "vulnerable": true } ], "operator": "OR" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:logo\\!_cmr2020_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:logo\\!_cmr2020:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:logo\\!_cmr2040_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:logo\\!_cmr2040:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_rtu3031c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_rtu3031c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_rtu3041c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_rtu3041c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_rtu3030c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_rtu3030c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_rtu3000c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_rtu3000c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-36475" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "An issue was discovered in Mbed TLS before 2.25.0 (and before 2.16.9 LTS and before 2.7.18 LTS). The calculations performed by mbedtls_mpi_exp_mod are not limited; thus, supplying overly large parameters could lead to denial of service when generating Diffie-Hellman key pairs." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-131" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9", "refsource": "MISC", "tags": [ "Release Notes", "Third Party Advisory" ], "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9" }, { "name": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0", "refsource": "MISC", "tags": [ "Release Notes", "Third Party Advisory" ], "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0" }, { "name": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18", "refsource": "MISC", "tags": [ "Release Notes", "Third Party Advisory" ], "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf", "refsource": "CONFIRM", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf" }, { "name": "[debian-lts-announce] 20211123 [SECURITY] [DLA 2826-1] mbedtls security update", "refsource": "MLIST", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "https://lists.debian.org/debian-lts-announce/2021/11/msg00021.html" }, { "name": "[debian-lts-announce] 20221225 [SECURITY] [DLA 3249-1] mbedtls security update", "refsource": "MLIST", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "https://lists.debian.org/debian-lts-announce/2022/12/msg00036.html" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } }, "lastModifiedDate": "2023-01-11T17:00Z", "publishedDate": "2021-08-23T02:15Z" } } }
cnvd-2021-71451
Vulnerability from cnvd
厂商已发布了漏洞修复程序,请及时关注更新: https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0
Name | ['ARM mbed TLS <2.25.0', 'ARM mbed TLS 2.16.9 LTS', 'ARM mbed TLS 2.7.18 LTS'] |
---|
{ "cves": { "cve": { "cveNumber": "CVE-2020-36475", "cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2020-36475" } }, "description": "ARM mbed TLS\u662f\u82f1\u56fdARM\u516c\u53f8\u7684\u4e00\u6b3e\u4e3ambed\u4ea7\u54c1\u63d0\u4f9b\u5b89\u5168\u901a\u8baf\u548c\u52a0\u5bc6\u529f\u80fd\u7684\u4ea7\u54c1\u3002\n\nARM mbed TLS\u5b58\u5728\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8embedtls_mpi_exp_mod\u6267\u884c\u7684\u8ba1\u7b97\u4e0d\u53d7\u9650\u5236\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u6b64\u6f0f\u6d1e\u63d0\u4f9b\u8fc7\u5927\u7684\u53c2\u6570\u53ef\u80fd\u5bfc\u81f4\u5728\u751f\u6210Diffie-Hellman\u5bc6\u94a5\u5bf9\u65f6\u53d1\u751f\u62d2\u7edd\u670d\u52a1\u3002", "formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2021-71451", "openTime": "2021-09-16", "patchDescription": "ARM mbed TLS\u662f\u82f1\u56fdARM\u516c\u53f8\u7684\u4e00\u6b3e\u4e3ambed\u4ea7\u54c1\u63d0\u4f9b\u5b89\u5168\u901a\u8baf\u548c\u52a0\u5bc6\u529f\u80fd\u7684\u4ea7\u54c1\u3002\r\n\r\nARM mbed TLS\u5b58\u5728\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8embedtls_mpi_exp_mod\u6267\u884c\u7684\u8ba1\u7b97\u4e0d\u53d7\u9650\u5236\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u6b64\u6f0f\u6d1e\u63d0\u4f9b\u8fc7\u5927\u7684\u53c2\u6570\u53ef\u80fd\u5bfc\u81f4\u5728\u751f\u6210Diffie-Hellman\u5bc6\u94a5\u5bf9\u65f6\u53d1\u751f\u62d2\u7edd\u670d\u52a1\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002", "patchName": "ARM mbed TLS\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\u7684\u8865\u4e01", "products": { "product": [ "ARM mbed TLS \u003c2.25.0", "ARM mbed TLS 2.16.9 LTS", "ARM mbed TLS 2.7.18 LTS" ] }, "referenceLink": "https://nvd.nist.gov/vuln/detail/CVE-2020-36475", "serverity": "\u4e2d", "submitTime": "2021-08-24", "title": "ARM mbed TLS\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e" }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.