CVE-2020-13916 (GCVE-0-2020-13916)
Vulnerability from cvelistv5
Published
2020-07-28 14:46
Modified
2024-08-04 12:32
Severity ?
CWE
  • n/a
Summary
A stack buffer overflow in webs in Ruckus Wireless Unleashed through 200.7.10.102.92 allows a remote attacker to execute code via an unauthenticated crafted HTTP request. This affects C110, E510, H320, H510, M510, R320, R310, R500, R510 R600, R610, R710, R720, R750, T300, T301n, T301s, T310c, T310d, T310n, T310s, T610, T710, and T710s devices.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T12:32:14.268Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.ruckuswireless.com/security_bulletins/304"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A stack buffer overflow in webs in Ruckus Wireless Unleashed through 200.7.10.102.92 allows a remote attacker to execute code via an unauthenticated crafted HTTP request. This affects C110, E510, H320, H510, M510, R320, R310, R500, R510 R600, R610, R710, R720, R750, T300, T301n, T301s, T310c, T310d, T310n, T310s, T610, T710, and T710s devices."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-28T14:46:16",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.ruckuswireless.com/security_bulletins/304"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-13916",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A stack buffer overflow in webs in Ruckus Wireless Unleashed through 200.7.10.102.92 allows a remote attacker to execute code via an unauthenticated crafted HTTP request. This affects C110, E510, H320, H510, M510, R320, R310, R500, R510 R600, R610, R710, R720, R750, T300, T301n, T301s, T310c, T310d, T310n, T310s, T610, T710, and T710s devices."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.ruckuswireless.com/security_bulletins/304",
              "refsource": "CONFIRM",
              "url": "https://support.ruckuswireless.com/security_bulletins/304"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-13916",
    "datePublished": "2020-07-28T14:46:16",
    "dateReserved": "2020-06-07T00:00:00",
    "dateUpdated": "2024-08-04T12:32:14.268Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2020-13916\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2020-07-28T15:15:11.687\",\"lastModified\":\"2024-11-21T05:02:08.510\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A stack buffer overflow in webs in Ruckus Wireless Unleashed through 200.7.10.102.92 allows a remote attacker to execute code via an unauthenticated crafted HTTP request. This affects C110, E510, H320, H510, M510, R320, R310, R500, R510 R600, R610, R710, R720, R750, T300, T301n, T301s, T310c, T310d, T310n, T310s, T610, T710, and T710s devices.\"},{\"lang\":\"es\",\"value\":\"Un desbordamiento del b\u00fafer de la pila en webs en Ruckus Wireless Unleashed versiones hasta 200.7.10.102.92, permite a un atacante remoto ejecutar c\u00f3digo por medio de una petici\u00f3n HTTP no autenticada. Esto afecta a los dispositivos C110, E510, H320, H510, M510, R320, R310, R500, R510 R600, R610, R710, R720, R750, T300, T301n, T301s, T310c, T310d, T310n, T310s, T610, y T710\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ruckuswireless:unleashed_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"200.7.10.102.92\",\"matchCriteriaId\":\"C3C6FE6A-B160-4C64-B900-9F5637EE2EF4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:c110:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A77671DB-6197-4C8D-B667-A0081350E5AF\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:e510:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FBF5C92C-C889-4732-BB00-E6D55613E410\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:h320:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"282C3A1D-711C-4415-B9BE-A9B518204AEB\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:h510:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CB1FAB48-786A-4FB3-AB6D-3118E94E68C7\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:m510:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D4AE7200-4090-4B81-A22F-B8553A014D21\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:r310:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"40D3129E-4C02-484F-96B6-59D76F787D21\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:r320:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"93CE3224-85D2-4039-8F24-BB503DFD42C2\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:r500:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9BBDBE9C-BE4B-4ED6-AF62-8FE484C519E2\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:r510:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"80B2E8CC-EACE-4A80-9EB1-DADAB8034415\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:r600:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5421B1D7-E630-4BDA-BA34-7DD8D0738DF4\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:r610:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4244947C-538E-4B83-B4F4-3DD4F3C22E83\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:r710:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E95884E9-C6AF-4106-A178-9274AD27EF65\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:r720:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DDFDAF0A-9F5D-4E34-805E-6F27103AAA32\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:r750:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BA49CB45-1196-4AD7-8AB6-C5593BBF015F\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:t300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0511674E-59A6-427C-A265-B277D84DE301\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:t301n:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EBB7A43E-F5F1-465A-841F-05214EDA6833\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:t301s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"68C4D9AC-5B1C-4066-8216-3F7127C3CC64\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:t310c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BFB69C4E-2B4F-4F61-8A65-9BA0354F33E3\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:t310d:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C2D3E8C6-4676-4B74-A252-132A26670C64\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:t310n:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2ED4C9B4-7F70-4059-8592-FD3F034160C3\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:t310s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"72378D4B-ADB5-4DE5-BB92-1778BDFD61FC\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:t610:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"210D55AB-9305-4D0B-B9F0-47889D37373B\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:t710:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A40B9489-D999-4355-953E-36A7F8DEF299\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:t710s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4CFF0772-D853-4781-B326-E3BDEAC78EE0\"}]}]}],\"references\":[{\"url\":\"https://support.ruckuswireless.com/security_bulletins/304\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://support.ruckuswireless.com/security_bulletins/304\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…