GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2020-12484 (GCVE-0-2020-12484)

Vulnerability from cvelistv5 – Published: 2024-12-17 02:36 – Updated: 2024-12-17 14:54
VLAI
Summary
When using special mode to connect to enterprise wifi, certain options are not properly configured and attackers can pretend to be enterprise wifi through a carefully constructed wifi with the same name, which can lead to man-in-the-middle attacks.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-12-17 14:54 UTC
CWE
  • CWE-306 - Missing Authentication for Critical Function
Impacted products
Vendor Product Version CPE status
vivo Wifi Affected: Versions earlier than 8.12.0.0
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-12484",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-17T14:54:11.114793Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-17T14:54:21.557Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Wifi",
          "vendor": "vivo",
          "versions": [
            {
              "status": "affected",
              "version": "Versions earlier than 8.12.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "When using special mode to connect to enterprise wifi, certain options are not properly configured and attackers can pretend to be enterprise wifi through a carefully constructed wifi with the same name, which can lead to man-in-the-middle attacks.\u003cbr\u003e"
            }
          ],
          "value": "When using special mode to connect to enterprise wifi, certain options are not properly configured and attackers can pretend to be enterprise wifi through a carefully constructed wifi with the same name, which can lead to man-in-the-middle attacks."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-151",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-151 Identity Spoofing"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-17T02:36:45.758Z",
        "orgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
        "shortName": "Vivo"
      },
      "references": [
        {
          "url": "https://www.vivo.com/en/support/security-advisory-detail?id=3"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
    "assignerShortName": "Vivo",
    "cveId": "CVE-2020-12484",
    "datePublished": "2024-12-17T02:36:45.758Z",
    "dateReserved": "2020-04-30T00:00:00.000Z",
    "dateUpdated": "2024-12-17T14:54:21.557Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2020-12484",
      "date": "2026-09-20",
      "epss": "0.00222",
      "percentile": "0.13062"
    },
    "fkie_nvd": {
      "descriptions": [
        {
          "lang": "en",
          "value": "When using special mode to connect to enterprise wifi, certain options are not properly configured and attackers can pretend to be enterprise wifi through a carefully constructed wifi with the same name, which can lead to man-in-the-middle attacks."
        },
        {
          "lang": "es",
          "value": "Al usar el modo especial para conectarse a una red wifi empresarial, ciertas opciones no est\u00e1n configuradas correctamente y los atacantes pueden hacerse pasar por una red wifi empresarial a trav\u00e9s de una red wifi cuidadosamente construida con el mismo nombre, lo que puede conducir a ataques de intermediario."
        }
      ],
      "id": "CVE-2020-12484",
      "lastModified": "2024-12-17T03:15:05.613",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.4,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 1.2,
            "impactScore": 5.2,
            "source": "security@vivo.com",
            "type": "Secondary"
          }
        ]
      },
      "published": "2024-12-17T03:15:05.613",
      "references": [
        {
          "source": "security@vivo.com",
          "url": "https://www.vivo.com/en/support/security-advisory-detail?id=3"
        }
      ],
      "sourceIdentifier": "security@vivo.com",
      "vulnStatus": "Awaiting Analysis",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-306"
            }
          ],
          "source": "security@vivo.com",
          "type": "Secondary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "When using special mode to connect to enterprise wifi, certain options are not properly configured and attackers can pretend to be enterprise wifi through a carefully constructed wifi with the same name, which can lead to man-in-the-middle attacks."
          },
          {
            "lang": "es",
            "value": "Al usar el modo especial para conectarse a una red wifi empresarial, ciertas opciones no est\u00e1n configuradas correctamente y los atacantes pueden hacerse pasar por una red wifi empresarial a trav\u00e9s de una red wifi cuidadosamente construida con el mismo nombre, lo que puede conducir a ataques de intermediario."
          }
        ],
        "id": "CVE-2020-12484",
        "lastModified": "2024-12-17T03:15:05.613",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "HIGH",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 1.2,
              "impactScore": 5.2,
              "source": "security@vivo.com",
              "type": "Secondary"
            }
          ]
        },
        "published": "2024-12-17T03:15:05.613",
        "references": [
          {
            "source": "security@vivo.com",
            "url": "https://www.vivo.com/en/support/security-advisory-detail?id=3"
          }
        ],
        "sourceIdentifier": "security@vivo.com",
        "vulnStatus": "Awaiting Analysis",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-306"
              }
            ],
            "source": "security@vivo.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2020-12484",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-12-17T14:54:11.114793Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-17T14:54:17.499Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Wifi",
              "vendor": "vivo",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions earlier than 8.12.0.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "When using special mode to connect to enterprise wifi, certain options are not properly configured and attackers can pretend to be enterprise wifi through a carefully constructed wifi with the same name, which can lead to man-in-the-middle attacks.\u003cbr\u003e"
                }
              ],
              "value": "When using special mode to connect to enterprise wifi, certain options are not properly configured and attackers can pretend to be enterprise wifi through a carefully constructed wifi with the same name, which can lead to man-in-the-middle attacks."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-151",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-151 Identity Spoofing"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-12-17T02:36:45.758Z",
            "orgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
            "shortName": "Vivo"
          },
          "references": [
            {
              "url": "https://www.vivo.com/en/support/security-advisory-detail?id=3"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
        "assignerShortName": "Vivo",
        "cveId": "CVE-2020-12484",
        "datePublished": "2024-12-17T02:36:45.758Z",
        "dateReserved": "2020-04-30T00:00:00.000Z",
        "dateUpdated": "2024-12-17T14:54:21.557Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…