CVE-2019-6579 (GCVE-0-2019-6579)
Vulnerability from cvelistv5
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
| URL | Tags | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens AG | Spectrum Power™ 4 |
Version: with Web Office Portal |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:23:22.043Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "107830",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/107830"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324467.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Spectrum Power\u2122 4",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "with Web Office Portal"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Spectrum Power 4 (with Web Office Portal). An attacker with network access to the web server on port 80/TCP or 443/TCP could execute system commands with administrative privileges. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises confidentiality, integrity or availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-04-24T15:56:28",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "107830",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/107830"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324467.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-6579",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Spectrum Power\u2122 4",
"version": {
"version_data": [
{
"version_value": "with Web Office Portal"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Spectrum Power 4 (with Web Office Portal). An attacker with network access to the web server on port 80/TCP or 443/TCP could execute system commands with administrative privileges. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises confidentiality, integrity or availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "107830",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/107830"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-324467.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324467.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-6579",
"datePublished": "2019-04-17T13:40:24",
"dateReserved": "2019-01-22T00:00:00",
"dateUpdated": "2024-08-04T20:23:22.043Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2019-6579\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2019-04-17T14:29:03.793\",\"lastModified\":\"2024-11-21T04:46:44.550\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Spectrum Power 4 (with Web Office Portal). An attacker with network access to the web server on port 80/TCP or 443/TCP could execute system commands with administrative privileges. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises confidentiality, integrity or availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.\"},{\"lang\":\"es\",\"value\":\"Se ha encontrado una vulnerabilidad en Spectrum Power versi\u00f3n 4 (con Web Office Portal). Un atacante con acceso de red al servidor web en el puerto 80/TCP o 443/TCP podr\u00eda ejecutar comandos de sistema con privilegios administrativos. La vulnerabilidad de la seguridad podr\u00eda ser aprovechada por un atacante no identificado con acceso de red al servicio afectado. No es necesario la interacci\u00f3n del usuario para aprvechar esta vulnerabilidad de seguridad. La operaci\u00f3n exito de la vulnerabilidad de seguridad compromete la confidencialidad, integridad o disponibilidad del sistema destino. En el momento de la publicaci\u00f3n de asesoramiento, no se conoc\u00eda la operaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:spectrum_power_4:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3D40B786-1DB0-444A-86F5-C4C8785E1DE7\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/107830\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-324467.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/107830\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-324467.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]}]}}"
}
}
fkie_cve-2019-6579
Vulnerability from fkie_nvd
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | http://www.securityfocus.com/bid/107830 | Third Party Advisory, VDB Entry | |
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-324467.pdf | Mitigation, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/107830 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-324467.pdf | Mitigation, Vendor Advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | spectrum_power_4 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:spectrum_power_4:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3D40B786-1DB0-444A-86F5-C4C8785E1DE7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Spectrum Power 4 (with Web Office Portal). An attacker with network access to the web server on port 80/TCP or 443/TCP could execute system commands with administrative privileges. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises confidentiality, integrity or availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known."
},
{
"lang": "es",
"value": "Se ha encontrado una vulnerabilidad en Spectrum Power versi\u00f3n 4 (con Web Office Portal). Un atacante con acceso de red al servidor web en el puerto 80/TCP o 443/TCP podr\u00eda ejecutar comandos de sistema con privilegios administrativos. La vulnerabilidad de la seguridad podr\u00eda ser aprovechada por un atacante no identificado con acceso de red al servicio afectado. No es necesario la interacci\u00f3n del usuario para aprvechar esta vulnerabilidad de seguridad. La operaci\u00f3n exito de la vulnerabilidad de seguridad compromete la confidencialidad, integridad o disponibilidad del sistema destino. En el momento de la publicaci\u00f3n de asesoramiento, no se conoc\u00eda la operaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad."
}
],
"id": "CVE-2019-6579",
"lastModified": "2024-11-21T04:46:44.550",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-04-17T14:29:03.793",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/107830"
},
{
"source": "productcert@siemens.com",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324467.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/107830"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324467.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
var-201904-0177
Vulnerability from variot
A vulnerability has been identified in Spectrum Power 4 (with Web Office Portal). An attacker with network access to the web server on port 80/TCP or 443/TCP could execute system commands with administrative privileges. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises confidentiality, integrity or availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known. Spectrum Power 4 Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. SiemensSpectrumPower is a system that provides the basic components for SCADA, communication and data modeling of control and monitoring systems
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201904-0177",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "spectrum power 4",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "spectrum power 4",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "spectrum power",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "4"
},
{
"model": "spectrum power",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.7"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "spectrum power 4",
"version": null
}
],
"sources": [
{
"db": "IVD",
"id": "83791c2d-3285-4e41-a870-1d0a9c27c954"
},
{
"db": "CNVD",
"id": "CNVD-2019-12906"
},
{
"db": "BID",
"id": "107830"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003489"
},
{
"db": "NVD",
"id": "CVE-2019-6579"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:siemens:spectrum_power_4",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-003489"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Applied Risk,Applied Risk reported this vulnerability to Siemens.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201904-465"
}
],
"trust": 0.6
},
"cve": "CVE-2019-6579",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2019-6579",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 1.9,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2019-12906",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "83791c2d-3285-4e41-a870-1d0a9c27c954",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.9 [IVD]"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2019-6579",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2019-6579",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2019-6579",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2019-6579",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2019-12906",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201904-465",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "IVD",
"id": "83791c2d-3285-4e41-a870-1d0a9c27c954",
"trust": 0.2,
"value": "CRITICAL"
},
{
"author": "VULMON",
"id": "CVE-2019-6579",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "83791c2d-3285-4e41-a870-1d0a9c27c954"
},
{
"db": "CNVD",
"id": "CNVD-2019-12906"
},
{
"db": "VULMON",
"id": "CVE-2019-6579"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003489"
},
{
"db": "CNNVD",
"id": "CNNVD-201904-465"
},
{
"db": "NVD",
"id": "CVE-2019-6579"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Spectrum Power 4 (with Web Office Portal). An attacker with network access to the web server on port 80/TCP or 443/TCP could execute system commands with administrative privileges. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises confidentiality, integrity or availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known. Spectrum Power 4 Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. SiemensSpectrumPower is a system that provides the basic components for SCADA, communication and data modeling of control and monitoring systems",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-6579"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003489"
},
{
"db": "CNVD",
"id": "CNVD-2019-12906"
},
{
"db": "BID",
"id": "107830"
},
{
"db": "IVD",
"id": "83791c2d-3285-4e41-a870-1d0a9c27c954"
},
{
"db": "VULMON",
"id": "CVE-2019-6579"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-6579",
"trust": 3.6
},
{
"db": "ICS CERT",
"id": "ICSA-19-099-02",
"trust": 2.4
},
{
"db": "BID",
"id": "107830",
"trust": 2.0
},
{
"db": "SIEMENS",
"id": "SSA-324467",
"trust": 2.0
},
{
"db": "CNVD",
"id": "CNVD-2019-12906",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201904-465",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003489",
"trust": 0.8
},
{
"db": "AUSCERT",
"id": "ESB-2019.1222",
"trust": 0.6
},
{
"db": "IVD",
"id": "83791C2D-3285-4E41-A870-1D0A9C27C954",
"trust": 0.2
},
{
"db": "VULMON",
"id": "CVE-2019-6579",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "83791c2d-3285-4e41-a870-1d0a9c27c954"
},
{
"db": "CNVD",
"id": "CNVD-2019-12906"
},
{
"db": "VULMON",
"id": "CVE-2019-6579"
},
{
"db": "BID",
"id": "107830"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003489"
},
{
"db": "CNNVD",
"id": "CNNVD-201904-465"
},
{
"db": "NVD",
"id": "CVE-2019-6579"
}
]
},
"id": "VAR-201904-0177",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "83791c2d-3285-4e41-a870-1d0a9c27c954"
},
{
"db": "CNVD",
"id": "CNVD-2019-12906"
}
],
"trust": 1.2743083
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
},
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.2
}
],
"sources": [
{
"db": "IVD",
"id": "83791c2d-3285-4e41-a870-1d0a9c27c954"
},
{
"db": "CNVD",
"id": "CNVD-2019-12906"
}
]
},
"last_update_date": "2024-11-23T23:08:25.826000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-324467",
"trust": 0.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324467.pdf"
},
{
"title": "Siemens Spectrum Power Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=91293"
},
{
"title": "Siemens Security Advisories: Siemens Security Advisory",
"trust": 0.1,
"url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=734d25d8df94a8c5e8326d29effa044c"
},
{
"title": "Attack-Defense-Analysis-of-a-Vulnerable-Network",
"trust": 0.1,
"url": "https://github.com/ActualSalt/Attack-Defense-Analysis-of-a-Vulnerable-Network "
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2019-6579"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003489"
},
{
"db": "CNNVD",
"id": "CNNVD-201904-465"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-77",
"trust": 1.0
},
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "CWE-264",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-003489"
},
{
"db": "NVD",
"id": "CVE-2019-6579"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "http://www.securityfocus.com/bid/107830"
},
{
"trust": 2.0,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324467.pdf"
},
{
"trust": 1.6,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-19-099-02"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-6579"
},
{
"trust": 0.9,
"url": "http://subscriber.communications.siemens.com/"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6579"
},
{
"trust": 0.8,
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-099-02"
},
{
"trust": 0.6,
"url": "https://vigilance.fr/vulnerability/siemens-spectrum-power-code-execution-via-os-command-injection-28975"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/78778"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-12906"
},
{
"db": "VULMON",
"id": "CVE-2019-6579"
},
{
"db": "BID",
"id": "107830"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003489"
},
{
"db": "CNNVD",
"id": "CNNVD-201904-465"
},
{
"db": "NVD",
"id": "CVE-2019-6579"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "83791c2d-3285-4e41-a870-1d0a9c27c954"
},
{
"db": "CNVD",
"id": "CNVD-2019-12906"
},
{
"db": "VULMON",
"id": "CVE-2019-6579"
},
{
"db": "BID",
"id": "107830"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-003489"
},
{
"db": "CNNVD",
"id": "CNNVD-201904-465"
},
{
"db": "NVD",
"id": "CVE-2019-6579"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-05-05T00:00:00",
"db": "IVD",
"id": "83791c2d-3285-4e41-a870-1d0a9c27c954"
},
{
"date": "2019-05-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-12906"
},
{
"date": "2019-04-17T00:00:00",
"db": "VULMON",
"id": "CVE-2019-6579"
},
{
"date": "2019-04-09T00:00:00",
"db": "BID",
"id": "107830"
},
{
"date": "2019-05-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-003489"
},
{
"date": "2019-04-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201904-465"
},
{
"date": "2019-04-17T14:29:03.793000",
"db": "NVD",
"id": "CVE-2019-6579"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-05-07T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-12906"
},
{
"date": "2020-10-16T00:00:00",
"db": "VULMON",
"id": "CVE-2019-6579"
},
{
"date": "2019-04-09T00:00:00",
"db": "BID",
"id": "107830"
},
{
"date": "2019-07-08T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-003489"
},
{
"date": "2020-10-19T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201904-465"
},
{
"date": "2024-11-21T04:46:44.550000",
"db": "NVD",
"id": "CVE-2019-6579"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201904-465"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens Spectrum Power Command injection vulnerability",
"sources": [
{
"db": "IVD",
"id": "83791c2d-3285-4e41-a870-1d0a9c27c954"
},
{
"db": "CNVD",
"id": "CNVD-2019-12906"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "permissions and access control issues",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201904-465"
}
],
"trust": 0.6
}
}
ICSA-19-099-02
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens",
"summary": "reported this vulnerability to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s TXT advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Siemens strongly recommends applying the provided security updates usingthe corresponding tooling and documented procedures made available withthe product. If supported by the product, an automated means to applythe security updates across multiple product instances may be used.",
"title": "General Recommendations"
},
{
"category": "general",
"text": "Siemens strongly recommends prior validation of any security updatebefore being applied, and supervision by trained staff of the updateprocess in the target environment.",
"title": "General Recommendations"
},
{
"category": "general",
"text": "As a general security measure Siemens strongly recommends to protectnetwork access with appropriate mechanisms (e.g. firewalls,segmentation, VPN). It is advised to configure the environment accordingto our operational guidelines in order to run the devices in a protectedIT environment.",
"title": "General Recommendations"
},
{
"category": "general",
"text": "Recommended security guidelines to Secure Substations can be found at:https://www.siemens.com/gridsecurity",
"title": "General Recommendations"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions containedin Siemens\u0027 underlying license terms or other applicable agreements previouslyagreed to with Siemens (hereinafter \"License Terms\"). To the extent applicableto information, software or documentation made available in or through aSiemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website(https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), inparticular Sections 8-10 of the Terms of Use, shall apply additionally. In caseof conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-324467: OS Command Injection in Spectrum Power 4.7",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-324467.txt"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-19-099-02 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/refs/heads/develop/csaf_files/OT/white/2019/icsa-19-099-02.json"
},
{
"category": "self",
"summary": "ICSA Advisory ICSA-19-099-02 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-099-02"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "ICSA-19-099-02 Siemens Spectrum Power 4.7",
"tracking": {
"current_release_date": "2019-04-09T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-19-099-02",
"initial_release_date": "2019-04-09T00:00:00.000000Z",
"revision_history": [
{
"date": "2019-04-09T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version",
"name": "with_Web_Office_Portal",
"product": {
"name": "Spectrum Power 4",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Spectrum Power 4"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2019-6579",
"cwe": {
"id": "CWE-77",
"name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An attacker with network access to the web server on port 80/TCP or 443/TCP could execute system commands with administrative privileges. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises confidentiality, integrity or availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-6579"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Take over bugfix bf-47456_PE_WOP_fix. Bugfix bf-47456_PE_WOP_fix for Web Office Portal can be obtained from the Siemens Energy Customer Support Center at: - Download: support.energy@siemens.com",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:firewall. Turn off the web server or limit access to the web server by an external",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
}
]
}
icsa-19-099-02
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens",
"summary": "reported this vulnerability to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s TXT advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Siemens strongly recommends applying the provided security updates usingthe corresponding tooling and documented procedures made available withthe product. If supported by the product, an automated means to applythe security updates across multiple product instances may be used.",
"title": "General Recommendations"
},
{
"category": "general",
"text": "Siemens strongly recommends prior validation of any security updatebefore being applied, and supervision by trained staff of the updateprocess in the target environment.",
"title": "General Recommendations"
},
{
"category": "general",
"text": "As a general security measure Siemens strongly recommends to protectnetwork access with appropriate mechanisms (e.g. firewalls,segmentation, VPN). It is advised to configure the environment accordingto our operational guidelines in order to run the devices in a protectedIT environment.",
"title": "General Recommendations"
},
{
"category": "general",
"text": "Recommended security guidelines to Secure Substations can be found at:https://www.siemens.com/gridsecurity",
"title": "General Recommendations"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions containedin Siemens\u0027 underlying license terms or other applicable agreements previouslyagreed to with Siemens (hereinafter \"License Terms\"). To the extent applicableto information, software or documentation made available in or through aSiemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website(https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), inparticular Sections 8-10 of the Terms of Use, shall apply additionally. In caseof conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-324467: OS Command Injection in Spectrum Power 4.7",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-324467.txt"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-19-099-02 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/refs/heads/develop/csaf_files/OT/white/2019/icsa-19-099-02.json"
},
{
"category": "self",
"summary": "ICSA Advisory ICSA-19-099-02 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-099-02"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "ICSA-19-099-02 Siemens Spectrum Power 4.7",
"tracking": {
"current_release_date": "2019-04-09T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-19-099-02",
"initial_release_date": "2019-04-09T00:00:00.000000Z",
"revision_history": [
{
"date": "2019-04-09T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version",
"name": "with_Web_Office_Portal",
"product": {
"name": "Spectrum Power 4",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Spectrum Power 4"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2019-6579",
"cwe": {
"id": "CWE-77",
"name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An attacker with network access to the web server on port 80/TCP or 443/TCP could execute system commands with administrative privileges. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises confidentiality, integrity or availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-6579"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Take over bugfix bf-47456_PE_WOP_fix. Bugfix bf-47456_PE_WOP_fix for Web Office Portal can be obtained from the Siemens Energy Customer Support Center at: - Download: support.energy@siemens.com",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:firewall. Turn off the web server or limit access to the web server by an external",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
}
]
}
CERTFR-2019-AVI-151
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SINAMICS G150 V4.6 toutes versions | ||
| Siemens | N/A | SINAMICS G150 V4.7 toutes versions | ||
| Siemens | N/A | SITOP PSU8600 toutes versions | ||
| Siemens | N/A | SIMATIC RF186C toutes versions | ||
| Siemens | N/A | SIMATIC Teleservice Adapter IE Standard toutes versions | ||
| Siemens | N/A | SIMATIC S7-1500 CPU family toutes versions | ||
| Siemens | N/A | SIMATIC RF181-EIP toutes versions | ||
| Siemens | N/A | SINAMICS S150 V4.8 toutes versions antérieures à V4.8 HF6 | ||
| Siemens | N/A | SIMOCODE pro V PN toutes versions | ||
| Siemens | N/A | SINAMICS G150 V5.1 SP1 toutes versions antérieures à V5.1 SP1 HF4 | ||
| Siemens | N/A | SIMATIC S7-1500 Software Controller toutes versions V2.5 et postérieures | ||
| Siemens | N/A | SINAMICS S150 V4.7 toutes versions | ||
| Siemens | N/A | SIMATIC ET 200 Open Controller CPU 1515SPPC2 toutes versions | ||
| Siemens | N/A | SIMATIC CP343-1 Advanced toutes versions | ||
| Siemens | N/A | TeleControl Server Basic toutes versions | ||
| Siemens | N/A | TIM 1531 IRC toutes versions | ||
| Siemens | N/A | SIMATIC CP443-1 OPC UA toutes versions | ||
| Siemens | N/A | SIMATIC HMI Comfort Outdoor Panels 7" & 15" toutes versions | ||
| Siemens | N/A | SINAMICS S210 V5.1 SP1 toutes versions | ||
| Siemens | N/A | SINAMICS G130 V5.1 SP1 toutes versions antérieures à V5.1 SP1 HF4 | ||
| Siemens | N/A | SIMATIC Teleservice Adapter IE Basic toutes versions | ||
| Siemens | N/A | CP1616 toutes versions | ||
| Siemens | N/A | SINAMICS S120 V4.7 toutes versions | ||
| Siemens | N/A | SIMATIC WinCC Runtime Mobile toutes versions | ||
| Siemens | N/A | SINAMICS S120 V5.1 SP1 toutes versions antérieures à V5.1 SP1 HF4 | ||
| Siemens | N/A | SINAMICS G130 V4.8 toutes versions antérieures à V4.8 HF6 | ||
| Siemens | N/A | SIMATIC S7-300 CPU family toutes versions antérieures à V3.X.16 | ||
| Siemens | N/A | CP1604 toutes versions | ||
| Siemens | N/A | SINEMA Remote Connect Client toutes versions antérieures à V2.0 HF1 | ||
| Siemens | N/A | SITOP Manager toutes versions | ||
| Siemens | N/A | SINAMICS G150 V5.1 toutes versions | ||
| Siemens | N/A | SIMATIC S7-1500 CPU family toutes versions V2.5 et postérieures | ||
| Siemens | N/A | SIMOCODE pro V EIP toutes versions antérieures à V1.0.2 | ||
| Siemens | N/A | SIMATIC CP443-1 Advanced toutes versions | ||
| Siemens | N/A | SINAMICS G150 V4.8 toutes versions antérieures à V4.8 HF6 | ||
| Siemens | N/A | SINEMA Remote Connect Server toutes versions antérieures à V2 | ||
| Siemens | N/A | SINAMICS G150 V4.7 SP1 toutes versions | ||
| Siemens | N/A | SIMATIC WinAC RTX 2010 toutes versions | ||
| Siemens | N/A | Spectrum Power 4 avec Web Office Portal | ||
| Siemens | N/A | SIMATIC HMI Comfort Panels 4" - 22" toutes versions | ||
| Siemens | N/A | SINAMICS S150 V5.1 SP1 toutes versions antérieures à V5.1 SP1 HF4 | ||
| Siemens | N/A | SINAMICS G130 V4.6 toutes versions | ||
| Siemens | N/A | SINAMICS S150 V4.7 SP1 toutes versions | ||
| Siemens | N/A | SIMATIC S7-PLCSIM Advanced toutes versions | ||
| Siemens | N/A | SIMATIC WinCC Runtime HSP Comfort toutes versions | ||
| Siemens | N/A | SIMOCODE pro V EIP toutes versions | ||
| Siemens | N/A | SIAMTIC RF185C toutes versions | ||
| Siemens | N/A | SIMATIC ET 200 SP Open Controller CPU1515SP PC2 toutes versions | ||
| Siemens | N/A | SIMATIC Teleservice Adapter IE Advanced toutes versions | ||
| Siemens | N/A | SIMATIC S7-400 PN/DP V7 (incl. F) toutes versions | ||
| Siemens | N/A | SIMATIC WinCC Runtime Advanced toutes versions | ||
| Siemens | N/A | SIMATIC IPC DiagMonitor toutes versions | ||
| Siemens | N/A | SINAMICS S120 V4.6 toutes versions | ||
| Siemens | N/A | SIMATIC WinCC OA toutes versions antérieures à V3.15-P018 | ||
| Siemens | N/A | SINAMICS S150 V4.6 toutes versions | ||
| Siemens | N/A | SIMATIC WinCC Runtime Comfort toutes versions | ||
| Siemens | N/A | SINAMICS G130 V4.7 toutes versions | ||
| Siemens | N/A | SINUMERIK OPC UA Server toutes versions antérieures à V2.1 | ||
| Siemens | N/A | SINAMICS G130 V4.7 SP1 toutes versions | ||
| Siemens | N/A | SIMATIC S7-400 PN (incl. F) V6 et antérieures toutes versions | ||
| Siemens | N/A | SINEMA Server toutes versions | ||
| Siemens | N/A | SINAMICS S120 V5.1 toutes versions | ||
| Siemens | N/A | SIMATIC RF188C toutes versions | ||
| Siemens | N/A | SITOP UPS1600 toutes versions | ||
| Siemens | N/A | SINAMICS S120 V4.8 toutes versions antérieures à V4.8 HF | ||
| Siemens | N/A | SIMATIC CP443-1 toutes versions | ||
| Siemens | N/A | SIMATIC ET 200 SP Open Controller CPU1515SP PC toutes versions antérieures à V2.1.6 | ||
| Siemens | N/A | SINAMICS S210 V5.1 toutes versions | ||
| Siemens | N/A | SINAMICS G130 V5.1 toutes versions | ||
| Siemens | N/A | RUGGEDCOM ROX II toutes versions antérieures à V2.13.0 | ||
| Siemens | N/A | SIMATIC NET PC Software toutes versions | ||
| Siemens | N/A | SINEC-NMS toutes versions | ||
| Siemens | N/A | SINAMICS S120 V4.7 SP1 toutes versions | ||
| Siemens | N/A | SIMATIC RF600R toutes versions | ||
| Siemens | N/A | SIMATIC S7-1500 Software Controller toutes versions | ||
| Siemens | N/A | SIMATIC HMI KTP Mobile Panels KTP400F,KTP700, KTP700F, KTP900 et KTP900F toutes versions | ||
| Siemens | N/A | SIMATIC RF182C toutes versions | ||
| Siemens | N/A | SINAMICS S150 V5.1 toutes versions |
| Title | Publication Time | Tags | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SINAMICS G150 V4.6 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS G150 V4.7 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SITOP PSU8600 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF186C toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Teleservice Adapter IE Standard toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU family toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF181-EIP toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS S150 V4.8 toutes versions ant\u00e9rieures \u00e0 V4.8 HF6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOCODE pro V PN toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS G150 V5.1 SP1 toutes versions ant\u00e9rieures \u00e0 V5.1 SP1 HF4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 Software Controller toutes versions V2.5 et post\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS S150 V4.7 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200 Open Controller CPU 1515SPPC2 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP343-1 Advanced toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TeleControl Server Basic toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 1531 IRC toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP443-1 OPC UA toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS S210 V5.1 SP1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS G130 V5.1 SP1 toutes versions ant\u00e9rieures \u00e0 V5.1 SP1 HF4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Teleservice Adapter IE Basic toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "CP1616 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS S120 V4.7 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC Runtime Mobile toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS S120 V5.1 SP1 toutes versions ant\u00e9rieures \u00e0 V5.1 SP1 HF4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS G130 V4.8 toutes versions ant\u00e9rieures \u00e0 V4.8 HF6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU family toutes versions ant\u00e9rieures \u00e0 V3.X.16",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "CP1604 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEMA Remote Connect Client toutes versions ant\u00e9rieures \u00e0 V2.0 HF1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SITOP Manager toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS G150 V5.1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU family toutes versions V2.5 et post\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOCODE pro V EIP toutes versions ant\u00e9rieures \u00e0 V1.0.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP443-1 Advanced toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS G150 V4.8 toutes versions ant\u00e9rieures \u00e0 V4.8 HF6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEMA Remote Connect Server toutes versions ant\u00e9rieures \u00e0 V2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS G150 V4.7 SP1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinAC RTX 2010 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Spectrum Power 4 avec Web Office Portal",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI Comfort Panels 4\" - 22\" toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS S150 V5.1 SP1 toutes versions ant\u00e9rieures \u00e0 V5.1 SP1 HF4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS G130 V4.6 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS S150 V4.7 SP1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-PLCSIM Advanced toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC Runtime HSP Comfort toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOCODE pro V EIP toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIAMTIC RF185C toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200 SP Open Controller CPU1515SP PC2 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Teleservice Adapter IE Advanced toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-400 PN/DP V7 (incl. F) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC Runtime Advanced toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC DiagMonitor toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS S120 V4.6 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC OA toutes versions ant\u00e9rieures \u00e0 V3.15-P018",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS S150 V4.6 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC Runtime Comfort toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS G130 V4.7 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK OPC UA Server toutes versions ant\u00e9rieures \u00e0 V2.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS G130 V4.7 SP1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-400 PN (incl. F) V6 et ant\u00e9rieures toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEMA Server toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS S120 V5.1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF188C toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SITOP UPS1600 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS S120 V4.8 toutes versions ant\u00e9rieures \u00e0 V4.8 HF",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP443-1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200 SP Open Controller CPU1515SP PC toutes versions ant\u00e9rieures \u00e0 V2.1.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS S210 V5.1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS G130 V5.1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX II toutes versions ant\u00e9rieures \u00e0 V2.13.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET PC Software toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEC-NMS toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS S120 V4.7 SP1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF600R toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 Software Controller toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI KTP Mobile Panels KTP400F,KTP700, KTP700F, KTP900 et KTP900F toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF182C toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS S150 V5.1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2019-6579",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6579"
},
{
"name": "CVE-2019-6575",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6575"
},
{
"name": "CVE-2019-6568",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6568"
},
{
"name": "CVE-2018-5380",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-5380"
},
{
"name": "CVE-2017-12741",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-12741"
},
{
"name": "CVE-2018-5381",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-5381"
},
{
"name": "CVE-2018-14618",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-14618"
},
{
"name": "CVE-2019-3822",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-3822"
},
{
"name": "CVE-2018-5379",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-5379"
},
{
"name": "CVE-2018-16890",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-16890"
},
{
"name": "CVE-2019-6570",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6570"
}
],
"initial_release_date": "2019-04-09T00:00:00",
"last_revision_date": "2019-04-09T00:00:00",
"links": [],
"reference": "CERTFR-2019-AVI-151",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2019-04-09T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de\ncode arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0 distance et un\ncontournement de la politique de s\u00e9curit\u00e9.\n",
"title": "SCADA Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-436177 du 09 avril 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-436177.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-480230 du 09 avril 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-141614 du 09 avril 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-324467 du 09 avril 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324467.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-451142 du 09 avril 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451142.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-307392 du 09 avril 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf"
}
]
}
cnvd-2019-12906
Vulnerability from cnvd
厂商尚未提供漏洞修复方案,请关注厂商主页更新: https://www.siemens.com/cert/advisories
| Name | Siemens Spectrum Power 4 |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2019-6579"
}
},
"description": "Siemens Spectrum Power\u662f\u4e00\u6b3e\u4e3a\u63a7\u5236\u548c\u76d1\u89c6\u7cfb\u7edf\u7684SCADA\uff0c\u901a\u4fe1\u548c\u6570\u636e\u5efa\u6a21\u63d0\u4f9b\u57fa\u672c\u7ec4\u4ef6\u7684\u7cfb\u7edf\u3002\n\nSiemens Spectrum Power\u5b58\u5728\u547d\u4ee4\u6ce8\u5165\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u6267\u884c\u64cd\u4f5c\u7cfb\u7edf\u547d\u4ee4\u3002",
"discovererName": "Applied Risk",
"formalWay": "\u5382\u5546\u5c1a\u672a\u63d0\u4f9b\u6f0f\u6d1e\u4fee\u590d\u65b9\u6848\uff0c\u8bf7\u5173\u6ce8\u5382\u5546\u4e3b\u9875\u66f4\u65b0\uff1a\r\nhttps://www.siemens.com/cert/advisories",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2019-12906",
"openTime": "2019-05-05",
"products": {
"product": "Siemens Spectrum Power 4"
},
"referenceLink": "https://ics-cert.us-cert.gov/advisories/ICSA-19-099-02",
"serverity": "\u9ad8",
"submitTime": "2019-04-10",
"title": "Siemens Spectrum Power\u547d\u4ee4\u6ce8\u5165\u6f0f\u6d1e"
}
ghsa-wq4c-88wr-4h4j
Vulnerability from github
A vulnerability has been identified in Spectrum Power 4 (with Web Office Portal). An attacker with network access to the web server on port 80/TCP or 443/TCP could execute system commands with administrative privileges. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises confidentiality, integrity or availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
{
"affected": [],
"aliases": [
"CVE-2019-6579"
],
"database_specific": {
"cwe_ids": [],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2019-04-17T14:29:00Z",
"severity": "CRITICAL"
},
"details": "A vulnerability has been identified in Spectrum Power 4 (with Web Office Portal). An attacker with network access to the web server on port 80/TCP or 443/TCP could execute system commands with administrative privileges. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises confidentiality, integrity or availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.",
"id": "GHSA-wq4c-88wr-4h4j",
"modified": "2022-05-13T01:14:33Z",
"published": "2022-05-13T01:14:33Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2019-6579"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324467.pdf"
},
{
"type": "WEB",
"url": "http://www.securityfocus.com/bid/107830"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
gsd-2019-6579
Vulnerability from gsd
{
"GSD": {
"alias": "CVE-2019-6579",
"description": "A vulnerability has been identified in Spectrum Power 4 (with Web Office Portal). An attacker with network access to the web server on port 80/TCP or 443/TCP could execute system commands with administrative privileges. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises confidentiality, integrity or availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.",
"id": "GSD-2019-6579"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2019-6579"
],
"details": "A vulnerability has been identified in Spectrum Power 4 (with Web Office Portal). An attacker with network access to the web server on port 80/TCP or 443/TCP could execute system commands with administrative privileges. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises confidentiality, integrity or availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.",
"id": "GSD-2019-6579",
"modified": "2023-12-13T01:23:49.750461Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-6579",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Spectrum Power\u2122 4",
"version": {
"version_data": [
{
"version_value": "with Web Office Portal"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Spectrum Power 4 (with Web Office Portal). An attacker with network access to the web server on port 80/TCP or 443/TCP could execute system commands with administrative privileges. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises confidentiality, integrity or availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "107830",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/107830"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-324467.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324467.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:spectrum_power_4:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-6579"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability has been identified in Spectrum Power 4 (with Web Office Portal). An attacker with network access to the web server on port 80/TCP or 443/TCP could execute system commands with administrative privileges. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises confidentiality, integrity or availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-324467.pdf",
"refsource": "MISC",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324467.pdf"
},
{
"name": "107830",
"refsource": "BID",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/107830"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
},
"lastModifiedDate": "2020-10-16T13:03Z",
"publishedDate": "2019-04-17T14:29Z"
}
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.