Summary
A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family < V4.x (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants) (All versions with Function State (FS) < 11), SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 11), SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 12), SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU family (All versions). There is an access mode used during manufacturing of the affected devices that allows additional diagnostic functionality. The security vulnerability could be exploited by an attacker with physical access to the UART interface during boot process.
References
Impacted products
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-05T00:05:44.067Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-686531.pdf", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { product: "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SIMATIC S7-1200 CPU family < V4.x (incl. SIPLUS variants)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions", }, ], }, { product: "SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions with Function State (FS) < 11", }, ], }, { product: "SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions <= V2.3.0 and Function State (FS) <= 3", }, ], }, { product: "SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions <= V2.3.0 and Function State (FS) <= 3", }, ], }, { product: "SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions <= V2.2.2 and Function State (FS) <= 8", }, ], }, { product: "SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions <= V2.3.0 and Function State (FS) <= 3", }, ], }, { product: "SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions <= V2.2.2 and Function State (FS) <= 10", }, ], }, { product: "SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions <= V2.3.0 and Function State (FS) <= 3", }, ], }, { product: "SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions <= V2.5.0 and Function State (FS) <= 11", }, ], }, { product: "SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions <= V2.5.0 and Function State (FS) <= 10", }, ], }, { product: "SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions <= V2.5.0 and Function State (FS) <= 10", }, ], }, { product: "SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions <= V2.5.0 and Function State (FS) <= 12", }, ], }, { product: "SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions <= V2.5.0 and Function State (FS) <= 9", }, ], }, { product: "SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions <= V2.5.0 and Function State (FS) <= 9", }, ], }, { product: "SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions <= V2.5.0 and Function State (FS) <= 8", }, ], }, { product: "SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0)", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions <= V2.5.0 and Function State (FS) <= 8", }, ], }, { product: "SIMATIC S7-200 SMART CPU family", vendor: "Siemens AG", versions: [ { status: "affected", version: "All versions", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family < V4.x (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants) (All versions with Function State (FS) < 11), SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 11), SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 12), SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU family (All versions). There is an access mode used during manufacturing of the affected devices that allows additional diagnostic functionality. The security vulnerability could be exploited by an attacker with physical access to the UART interface during boot process.", }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-749", description: "CWE-749: Exposed Dangerous Method or Function", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2020-07-14T13:18:04", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { tags: [ "x_refsource_MISC", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-686531.pdf", }, ], x_legacyV4Record: { CVE_data_meta: { ASSIGNER: "productcert@siemens.com", ID: "CVE-2019-13945", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SIMATIC S7-1200 CPU family < V4.x (incl. SIPLUS variants)", version: { version_data: [ { version_value: "All versions", }, ], }, }, { product_name: "SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants)", version: { version_data: [ { version_value: "All versions with Function State (FS) < 11", }, ], }, }, { product_name: "SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1)", version: { version_data: [ { version_value: "All versions <= V2.3.0 and Function State (FS) <= 3", }, ], }, }, { product_name: "SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1)", version: { version_data: [ { version_value: "All versions <= V2.3.0 and Function State (FS) <= 3", }, ], }, }, { product_name: "SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0)", version: { version_data: [ { version_value: "All versions <= V2.2.2 and Function State (FS) <= 8", }, ], }, }, { product_name: "SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1)", version: { version_data: [ { version_value: "All versions <= V2.3.0 and Function State (FS) <= 3", }, ], }, }, { product_name: "SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0)", version: { version_data: [ { version_value: "All versions <= V2.2.2 and Function State (FS) <= 10", }, ], }, }, { product_name: "SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1)", version: { version_data: [ { version_value: "All versions <= V2.3.0 and Function State (FS) <= 3", }, ], }, }, { product_name: "SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0)", version: { version_data: [ { version_value: "All versions <= V2.5.0 and Function State (FS) <= 11", }, ], }, }, { product_name: "SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0)", version: { version_data: [ { version_value: "All versions <= V2.5.0 and Function State (FS) <= 10", }, ], }, }, { product_name: "SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0)", version: { version_data: [ { version_value: "All versions <= V2.5.0 and Function State (FS) <= 10", }, ], }, }, { product_name: "SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0)", version: { version_data: [ { version_value: "All versions <= V2.5.0 and Function State (FS) <= 12", }, ], }, }, { product_name: "SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0)", version: { version_data: [ { version_value: "All versions <= V2.5.0 and Function State (FS) <= 9", }, ], }, }, { product_name: "SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0)", version: { version_data: [ { version_value: "All versions <= V2.5.0 and Function State (FS) <= 9", }, ], }, }, { product_name: "SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0)", version: { version_data: [ { version_value: "All versions <= V2.5.0 and Function State (FS) <= 8", }, ], }, }, { product_name: "SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0)", version: { version_data: [ { version_value: "All versions <= V2.5.0 and Function State (FS) <= 8", }, ], }, }, { product_name: "SIMATIC S7-200 SMART CPU family", version: { version_data: [ { version_value: "All versions", }, ], }, }, ], }, vendor_name: "Siemens AG", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family < V4.x (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants) (All versions with Function State (FS) < 11), SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 11), SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 12), SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU family (All versions). There is an access mode used during manufacturing of the affected devices that allows additional diagnostic functionality. The security vulnerability could be exploited by an attacker with physical access to the UART interface during boot process.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "eng", value: "CWE-749: Exposed Dangerous Method or Function", }, ], }, ], }, references: { reference_data: [ { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-686531.pdf", refsource: "MISC", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-686531.pdf", }, ], }, }, }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2019-13945", datePublished: "2019-12-12T13:19:51", dateReserved: "2019-07-18T00:00:00", dateUpdated: "2024-08-05T00:05:44.067Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", "vulnerability-lookup:meta": { nvd: "{\"cve\":{\"id\":\"CVE-2019-13945\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2019-12-12T14:15:15.133\",\"lastModified\":\"2024-11-21T04:25:44.930\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family < V4.x (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants) (All versions with Function State (FS) < 11), SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 11), SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 12), SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU family (All versions). There is an access mode used during manufacturing of the affected devices that allows additional diagnostic functionality. The security vulnerability could be exploited by an attacker with physical access to the UART interface during boot process.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en la familia de CPU SIMATIC S7-1200 (incluidas las variantes SIPLUS) (Toas las versiones), SIMATIC S7-1200 CPU family < V4.x (incluidas las variantes SIPLUS) (Toas las versiones), SIMATIC S7-1200 CPU family V4.x (incluidas las variantes SIPLUS) (Toas las versiones with Function State (FS) anteriores a 11), SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1) (Todas las versiones o igual a V2.3.0 y Function State (FS) anteriores o igual a 3), SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1) (Todas las versiones o igual a V2.3.0 y Function State (FS) anteriores o igual a 3), SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0) (Todas las versiones o igual a V2.2.2 y Function State (FS) anteriores o igual a 8), SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1) (Todas las versiones o igual a V2.3.0 y Function State (FS) anteriores o igual a 3), SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0) (Todas las versiones o igual a V2.2.2 y Function State (FS) anteriores o igual a 10), SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1) (Todas las versiones o igual a V2.3.0 y Function State (FS) anteriores o igual a 3), SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0) (Todas las versiones o igual a V2.5.0 y Function State (FS) anteriores o igual a 11), SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0) (Todas las versiones o igual a V2.5.0 y Function State (FS) anteriores o igual a 10), SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0) (Todas las versiones o igual a V2.5.0 y Function State (FS) anteriores o igual a 10), SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0) (Todas las versiones o igual a V2.5.0 y Function State (FS) anteriores o igual a 12), SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0) (Todas las versiones o igual a V2.5.0 y Function State (FS) anteriores o igual a 9), SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0) (Todas las versiones o igual a V2.5.0 y Function State (FS) anteriores o igual a 9), SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0) (Todas las versiones o igual a V2.5.0 y Function State (FS) anteriores o igual a 8), SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0) (Todas las versiones o igual a V2.5.0 y Function State (FS) anteriores o igual a 8), SIMATIC S7-200 SMART CPU family (Toas las versiones). Existe un modo de acceso utilizado durante la fabricación de CPU S7-1200 que permite una funcionalidad de diagnóstico adicional. La vulnerabilidad de seguridad podría ser explotada por un atacante con acceso físico a la interfaz UART durante el proceso de arranque\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":4.6,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-749\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A6AD4E09-BE4A-45D5-AA55-BA7365D12DD6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EC545350-FD53-4B2E-886F-E20F12260C9B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:s7-200_smart_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"44B4D7A7-E9B2-4F3D-A87E-C44426C923F4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:s7-200_smart:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BB4495AE-B326-45C1-9CA8-A8BD97234D1C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_st20_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.5.0\",\"matchCriteriaId\":\"A857E06F-0DAA-462E-B067-5FCAF626215D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_st20:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"13D741B0-7F5A-4275-9735-D0634D06128C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_st30_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.5.0\",\"matchCriteriaId\":\"392AE5E1-6B9A-4F40-8B3B-1C9BBCAD13D6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_st30:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A65B5553-C61F-486D-9CB7-33346C3C2833\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_st40_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.5.0\",\"matchCriteriaId\":\"A0EA8CFC-A1DC-42D5-8DB9-26FF3748F397\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_st40:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"041993EF-ED92-45C8-9D0F-CCB99CA6D789\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_st60_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.5.0\",\"matchCriteriaId\":\"4905F166-016E-4ECE-82C4-1668708EB735\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_st60:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"83012A83-6BED-4EAE-B144-F8F7A804F24B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_sr20_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.5.0\",\"matchCriteriaId\":\"F96F95AB-651B-4BCB-BD78-65570A011242\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_sr20:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3606B1DC-DB6A-4E8D-972A-EB48F33918CF\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_sr30_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.5.0\",\"matchCriteriaId\":\"47557189-8EEB-4ADE-AE74-C064B4A0DA4B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_sr30:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D8D693F0-738C-4E31-93ED-4467A9D99E9C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_sr40_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.5.0\",\"matchCriteriaId\":\"5326B002-BFD4-40AC-9234-485E0AE05887\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_sr40:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E40D7FC9-E9EC-49FE-B60C-0DD9A0FA307F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_sr60_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.5.0\",\"matchCriteriaId\":\"AD785A02-C3EA-415E-8764-D4514E83B0BA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_sr60:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0211A90A-D654-45E3-A519-8928A31682CC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_cr40_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.2.2\",\"matchCriteriaId\":\"0CA9611A-9A9F-40D0-9A66-7ABA4F6B2985\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_cr40:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"415D9D18-5A3B-4D8C-90B3-F02DE378519C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_cr60_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.2.2\",\"matchCriteriaId\":\"3188BE0B-A28D-487E-81EC-CA10BDDAE369\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_cr60:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"261039FA-7803-4072-857D-24F3613ABDB5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_cr20s_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.3.0\",\"matchCriteriaId\":\"B208404C-ACE6-49B8-955A-23B84864810C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_cr20s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AFDD569B-53CD-497F-9339-94AA143916E4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_cr30s_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.3.0\",\"matchCriteriaId\":\"9E352EB8-37E9-45C4-A7D2-2EDC4BA99DB4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_cr30s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"33D5ED5A-00BA-4F29-B5F2-257A90B100E7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_cr40s_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.3.0\",\"matchCriteriaId\":\"77DA47C6-4C54-4A88-8129-0DF0A161B79B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_cr40s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"718E9DD0-8F17-40E3-871B-7976359EC7C2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_cr60s_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.3.0\",\"matchCriteriaId\":\"D3FA2207-9C99-400B-BFC7-C7E33701E73A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_cr60s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C760B61E-812F-4381-B9FA-6F887EB500E1\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-686531.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-686531.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}", }, }
Log in or create an account to share your comment.
Security Advisory comment format.
This schema specifies the format of a comment related to a security advisory.
Title of the comment
Description of the comment
Loading…
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.