CVE-2019-13929 (GCVE-0-2019-13929)
Vulnerability from cvelistv5
- CWE-321 - Use of Hard-coded Cryptographic Key
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens AG | SIMATIC IT UADM |
Version: All versions < V1.3 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T00:05:43.943Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC IT UADM", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V1.3" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC IT UADM (All versions \u003c V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-321", "description": "CWE-321: Use of Hard-coded Cryptographic Key", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-10-10T13:49:24", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-13929", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC IT UADM", "version": { "version_data": [ { "version_value": "All versions \u003c V1.3" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC IT UADM (All versions \u003c V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-321: Use of Hard-coded Cryptographic Key" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-13929", "datePublished": "2019-10-10T13:49:24", "dateReserved": "2019-07-18T00:00:00", "dateUpdated": "2024-08-05T00:05:43.943Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2019-13929\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2019-10-10T14:15:14.860\",\"lastModified\":\"2024-11-21T04:25:43.067\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC IT UADM (All versions \u003c V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SIMATIC IT UADM (Todas las versiones anteriores a V1.3). Un atacante remoto autenticado con acceso de red en puerto 1434/tcp de SIMATIC IT UADM podr\u00eda recuperar una contrase\u00f1a que puede ser usada para conseguir acceso de lectura y escritura en la estaci\u00f3n TeamCenter relacionada. La vulnerabilidad de seguridad podr\u00eda ser explotada solo si el atacante est\u00e1 autenticado. Una interacci\u00f3n del usuario no es requerida para explotar esta vulnerabilidad de seguridad. La explotaci\u00f3n exitosa de la vulnerabilidad de seguridad compromete la confidencialidad del sistema destino. En el momento de la publicaci\u00f3n del aviso, no se conoc\u00eda la explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:N/A:N\",\"baseScore\":4.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-321\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-330\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_it_uadm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.3\",\"matchCriteriaId\":\"0D742511-E68B-449B-A70D-00755DBA48C5\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
CERTFR-2019-AVI-489
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Elles permettent à un attaquant de provoquer un déni de service à distance, une atteinte à l'intégrité des données et une atteinte à la confidentialité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneVendor | Product | Description | ||
---|---|---|---|---|
Siemens | N/A | SIMATIC PROFINET Driver versions antérieures à V2.1 | ||
Siemens | N/A | SINAMICS G120 V4.7 (PN Control Unit) versions antérieures à V4.7 SP10 HF5 | ||
Siemens | N/A | SIMATIC CFU PA versions antérieures à V1.2.0 | ||
Siemens | N/A | SINAMICS S120 V4.7 (Control Unit et CBE20) versions antérieures à V4.7 HF34 ou V5.2 HF2 | ||
Siemens | N/A | SINAMICS GH150 V4.7 (Control Unit) versions antérieures à V4.8 SP2 HF9 | ||
Siemens | N/A | SIMATIC ET 200SP IM 155-6 PN/2 HF versions antérieures à V4.2.2 | ||
Siemens | N/A | SINAMICS G120 V4.7 (Control Unit) versions antérieures à V4.7 SP10 HF5 | ||
Siemens | N/A | SIMATIC ET 200SP IM 155-6 PN/3 HF versions antérieures à V4.2.1 | ||
Siemens | N/A | SCALANCE X-200IRT versions antérieures à V5.4.2 | ||
Siemens | N/A | SINAMICS G130 V4.7 (Control Unit) versions antérieures à V4.7 HF29 ou V5.2 HF2 | ||
Siemens | N/A | Development/Evaluation Kits for PROFINET IO:DK Standard Ethernet Controller versions antérieures à V4.1.1 Patch 05 | ||
Siemens | N/A | Development/Evaluation Kits for PROFINET IO:EK-ERTEC 200P versions antérieures à V4.5.0 | ||
Siemens | N/A | SINAMICS GL150 V4.7 (Control Unit) versions antérieures à V4.8 SP2 HF9 | ||
Siemens | N/A | CP1616 versions antérieures à V2.8 | ||
Siemens | N/A | SINAMICS G110M V4.7 (Control Unit) versions antérieures à V4.7 SP10 HF5 | ||
Siemens | N/A | SIMATIC ET 200MP IM 155-5 PN BA versions antérieures à V4.2.3 | ||
Siemens | N/A | SINAMICS G110M V4.7 (PN Control Unit) versions antérieures à V4.7 SP10 HF5 | ||
Siemens | N/A | SINAMICS DCM versions antérieures à V1.5 HF1 | ||
Siemens | N/A | SINAMICS GM150 V4.7 (Control Unit) versions antérieures à V4.8 SP2 HF9 | ||
Siemens | N/A | SIMATIC IT UADM versions antérieures à V1.3 | ||
Siemens | N/A | Development/Evaluation Kits for PROFINET IO:EK-ERTEC 200 versions antérieures à V4.5.0 Patch 01 | ||
Siemens | N/A | SIMATIC S7-400H V6 versions antérieures à V6.0.9 | ||
Siemens | N/A | SIMATIC WinAC RTX (F) 2010 versions antérieures à SIMATIC WinAC RTX 2010 SP3 avec les mises à jour BIOS et Windows | ||
Siemens | N/A | SIMATIC ET 200SP IM 155-6 PN HF versions antérieures à V4.2.2 | ||
Siemens | N/A | CP1604 versions antérieures à V2.8 | ||
Siemens | N/A | SINUMERIK 828D versions antérieures à V4.8 SP5 |
Title | Publication Time | Tags | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "SIMATIC PROFINET Driver versions ant\u00e9rieures \u00e0 V2.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINAMICS G120 V4.7 (PN Control Unit) versions ant\u00e9rieures \u00e0 V4.7 SP10 HF5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC CFU PA versions ant\u00e9rieures \u00e0 V1.2.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINAMICS S120 V4.7 (Control Unit et CBE20) versions ant\u00e9rieures \u00e0 V4.7 HF34 ou V5.2 HF2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINAMICS GH150 V4.7 (Control Unit) versions ant\u00e9rieures \u00e0 V4.8 SP2 HF9", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC ET 200SP IM 155-6 PN/2 HF versions ant\u00e9rieures \u00e0 V4.2.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINAMICS G120 V4.7 (Control Unit) versions ant\u00e9rieures \u00e0 V4.7 SP10 HF5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC ET 200SP IM 155-6 PN/3 HF versions ant\u00e9rieures \u00e0 V4.2.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X-200IRT versions ant\u00e9rieures \u00e0 V5.4.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINAMICS G130 V4.7 (Control Unit) versions ant\u00e9rieures \u00e0 V4.7 HF29 ou V5.2 HF2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Development/Evaluation Kits for PROFINET IO:DK Standard Ethernet Controller versions ant\u00e9rieures \u00e0 V4.1.1 Patch 05", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Development/Evaluation Kits for PROFINET IO:EK-ERTEC 200P versions ant\u00e9rieures \u00e0 V4.5.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINAMICS GL150 V4.7 (Control Unit) versions ant\u00e9rieures \u00e0 V4.8 SP2 HF9", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "CP1616 versions ant\u00e9rieures \u00e0 V2.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINAMICS G110M V4.7 (Control Unit) versions ant\u00e9rieures \u00e0 V4.7 SP10 HF5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC ET 200MP IM 155-5 PN BA versions ant\u00e9rieures \u00e0 V4.2.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINAMICS G110M V4.7 (PN Control Unit) versions ant\u00e9rieures \u00e0 V4.7 SP10 HF5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINAMICS DCM versions ant\u00e9rieures \u00e0 V1.5 HF1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINAMICS GM150 V4.7 (Control Unit) versions ant\u00e9rieures \u00e0 V4.8 SP2 HF9", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC IT UADM versions ant\u00e9rieures \u00e0 V1.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Development/Evaluation Kits for PROFINET IO:EK-ERTEC 200 versions ant\u00e9rieures \u00e0 V4.5.0 Patch 01", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-400H V6 versions ant\u00e9rieures \u00e0 V6.0.9", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC WinAC RTX (F) 2010 versions ant\u00e9rieures \u00e0 SIMATIC WinAC RTX 2010 SP3 avec les mises \u00e0 jour BIOS et Windows", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC ET 200SP IM 155-6 PN HF versions ant\u00e9rieures \u00e0 V4.2.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "CP1604 versions ant\u00e9rieures \u00e0 V2.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINUMERIK 828D versions ant\u00e9rieures \u00e0 V4.8 SP5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2019-11091", "url": "https://www.cve.org/CVERecord?id=CVE-2019-11091" }, { "name": "CVE-2018-12127", "url": "https://www.cve.org/CVERecord?id=CVE-2018-12127" }, { "name": "CVE-2019-10936", "url": "https://www.cve.org/CVERecord?id=CVE-2019-10936" }, { "name": "CVE-2017-5754", "url": "https://www.cve.org/CVERecord?id=CVE-2017-5754" }, { "name": "CVE-2018-12130", "url": "https://www.cve.org/CVERecord?id=CVE-2018-12130" }, { "name": "CVE-2019-10923", "url": "https://www.cve.org/CVERecord?id=CVE-2019-10923" }, { "name": "CVE-2018-3620", "url": "https://www.cve.org/CVERecord?id=CVE-2018-3620" }, { "name": "CVE-2018-3639", "url": "https://www.cve.org/CVERecord?id=CVE-2018-3639" }, { "name": "CVE-2019-13929", "url": "https://www.cve.org/CVERecord?id=CVE-2019-13929" }, { "name": "CVE-2019-13921", "url": "https://www.cve.org/CVERecord?id=CVE-2019-13921" }, { "name": "CVE-2017-5753", "url": "https://www.cve.org/CVERecord?id=CVE-2017-5753" }, { "name": "CVE-2018-3646", "url": "https://www.cve.org/CVERecord?id=CVE-2018-3646" }, { "name": "CVE-2018-12126", "url": "https://www.cve.org/CVERecord?id=CVE-2018-12126" }, { "name": "CVE-2017-5715", "url": "https://www.cve.org/CVERecord?id=CVE-2017-5715" }, { "name": "CVE-2018-3640", "url": "https://www.cve.org/CVERecord?id=CVE-2018-3640" }, { "name": "CVE-2018-3615", "url": "https://www.cve.org/CVERecord?id=CVE-2018-3615" } ], "initial_release_date": "2019-10-08T00:00:00", "last_revision_date": "2019-10-08T00:00:00", "links": [], "reference": "CERTFR-2019-AVI-489", "revisions": [ { "description": "Version initiale", "revision_date": "2019-10-08T00:00:00.000000" } ], "risks": [ { "description": "D\u00e9ni de service \u00e0 distance" }, { "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es" }, { "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Elles permettent \u00e0 un attaquant de provoquer un d\u00e9ni de service\n\u00e0 distance, une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es et une atteinte \u00e0 la\nconfidentialit\u00e9 des donn\u00e9es.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-608355 du 08 octobre 2019", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-608355.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-349422 du 08 octobre 2019", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-878278 du 08 octobre 2019", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-878278.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-473245 du 08 octobre 2019", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-984700 du 08 octobre 2019", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf" } ] }
gsd-2019-13929
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2019-13929", "description": "A vulnerability has been identified in SIMATIC IT UADM (All versions \u003c V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.", "id": "GSD-2019-13929" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2019-13929" ], "details": "A vulnerability has been identified in SIMATIC IT UADM (All versions \u003c V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.", "id": "GSD-2019-13929", "modified": "2023-12-13T01:23:41.609408Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-13929", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC IT UADM", "version": { "version_data": [ { "version_value": "All versions \u003c V1.3" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC IT UADM (All versions \u003c V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-321: Use of Hard-coded Cryptographic Key" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:simatic_it_uadm:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-13929" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC IT UADM (All versions \u003c V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-330" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf", "refsource": "CONFIRM", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6 } }, "lastModifiedDate": "2020-10-16T13:16Z", "publishedDate": "2019-10-10T14:15Z" } } }
var-201910-0917
Vulnerability from variot
A vulnerability has been identified in SIMATIC IT UADM (All versions < V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known. SIMATIC IT UADM Contains a vulnerability related to information disclosure from the cache.Information may be obtained. Siemens SIMATIC IT Unified Architecture Discrete Manufacturing (UADM) is a set of Manufacturing Execution System (MES) solutions from Siemens, Germany.
A password storage vulnerability exists in Siemens SIMATIC IT UADM
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201910-0917", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic it uadm", "scope": "lt", "trust": 2.4, "vendor": "siemens", "version": "1.3" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic it uadm", "version": "*" } ], "sources": [ { "db": "IVD", "id": "2b632d60-b3f0-452d-a02a-ca327aef1c0b" }, { "db": "CNVD", "id": "CNVD-2019-34596" }, { "db": "JVNDB", "id": "JVNDB-2019-010607" }, { "db": "NVD", "id": "CVE-2019-13929" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:simatic_it_uadm", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-010607" } ] }, "cve": "CVE-2019-13929", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "CVE-2019-13929", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 6.8, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2019-34596", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "IVD", "availabilityImpact": "NONE", "baseScore": 6.8, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "2b632d60-b3f0-452d-a02a-ca327aef1c0b", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:S/C:C/I:N/A:N", "version": "2.9 [IVD]" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2019-13929", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 6.5, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2019-13929", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2019-13929", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2019-13929", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2019-34596", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201910-417", "trust": 0.6, "value": "MEDIUM" }, { "author": "IVD", "id": "2b632d60-b3f0-452d-a02a-ca327aef1c0b", "trust": 0.2, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2019-13929", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "2b632d60-b3f0-452d-a02a-ca327aef1c0b" }, { "db": "CNVD", "id": "CNVD-2019-34596" }, { "db": "VULMON", "id": "CVE-2019-13929" }, { "db": "JVNDB", "id": "JVNDB-2019-010607" }, { "db": "CNNVD", "id": "CNNVD-201910-417" }, { "db": "NVD", "id": "CVE-2019-13929" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC IT UADM (All versions \u003c V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known. SIMATIC IT UADM Contains a vulnerability related to information disclosure from the cache.Information may be obtained. Siemens SIMATIC IT Unified Architecture Discrete Manufacturing (UADM) is a set of Manufacturing Execution System (MES) solutions from Siemens, Germany. \n\nA password storage vulnerability exists in Siemens SIMATIC IT UADM", "sources": [ { "db": "NVD", "id": "CVE-2019-13929" }, { "db": "JVNDB", "id": "JVNDB-2019-010607" }, { "db": "CNVD", "id": "CNVD-2019-34596" }, { "db": "IVD", "id": "2b632d60-b3f0-452d-a02a-ca327aef1c0b" }, { "db": "VULMON", "id": "CVE-2019-13929" } ], "trust": 2.43 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-13929", "trust": 3.3 }, { "db": "SIEMENS", "id": "SSA-984700", "trust": 2.3 }, { "db": "ICS CERT", "id": "ICSA-19-281-04", "trust": 1.4 }, { "db": "CNVD", "id": "CNVD-2019-34596", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201910-417", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2019-010607", "trust": 0.8 }, { "db": "AUSCERT", "id": "ESB-2019.3779", "trust": 0.6 }, { "db": "IVD", "id": "2B632D60-B3F0-452D-A02A-CA327AEF1C0B", "trust": 0.2 }, { "db": "VULMON", "id": "CVE-2019-13929", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "2b632d60-b3f0-452d-a02a-ca327aef1c0b" }, { "db": "CNVD", "id": "CNVD-2019-34596" }, { "db": "VULMON", "id": "CVE-2019-13929" }, { "db": "JVNDB", "id": "JVNDB-2019-010607" }, { "db": "CNNVD", "id": "CNNVD-201910-417" }, { "db": "NVD", "id": "CVE-2019-13929" } ] }, "id": "VAR-201910-0917", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "2b632d60-b3f0-452d-a02a-ca327aef1c0b" }, { "db": "CNVD", "id": "CNVD-2019-34596" } ], "trust": 1.4666667 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "2b632d60-b3f0-452d-a02a-ca327aef1c0b" }, { "db": "CNVD", "id": "CNVD-2019-34596" } ] }, "last_update_date": "2024-11-23T22:48:13.514000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-984700", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf" }, { "title": "Patch for Siemens SIMATIC IT UADM password storage vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/184349" }, { "title": "Siemens SIMATIC IT Unified Architecture Discrete Manufacturing Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=99084" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=218cc8b0370afec50119bc253e2d9c78" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-34596" }, { "db": "VULMON", "id": "CVE-2019-13929" }, { "db": "JVNDB", "id": "JVNDB-2019-010607" }, { "db": "CNNVD", "id": "CNNVD-201910-417" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-330", "trust": 1.0 }, { "problemtype": "CWE-321", "trust": 1.0 }, { "problemtype": "CWE-522", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-010607" }, { "db": "NVD", "id": "CVE-2019-13929" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf" }, { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-13929" }, { "trust": 1.4, "url": "https://www.us-cert.gov/ics/advisories/icsa-19-281-04" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-13929" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2019.3779/" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/simatic-it-uadm-privilege-escalation-via-password-recovery-30561" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/330.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.symantec.com/content/symantec/english/en/security-center/vulnerabilities/writeup.html/110371" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-34596" }, { "db": "VULMON", "id": "CVE-2019-13929" }, { "db": "JVNDB", "id": "JVNDB-2019-010607" }, { "db": "CNNVD", "id": "CNNVD-201910-417" }, { "db": "NVD", "id": "CVE-2019-13929" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "2b632d60-b3f0-452d-a02a-ca327aef1c0b" }, { "db": "CNVD", "id": "CNVD-2019-34596" }, { "db": "VULMON", "id": "CVE-2019-13929" }, { "db": "JVNDB", "id": "JVNDB-2019-010607" }, { "db": "CNNVD", "id": "CNNVD-201910-417" }, { "db": "NVD", "id": "CVE-2019-13929" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-10-11T00:00:00", "db": "IVD", "id": "2b632d60-b3f0-452d-a02a-ca327aef1c0b" }, { "date": "2019-10-11T00:00:00", "db": "CNVD", "id": "CNVD-2019-34596" }, { "date": "2019-10-10T00:00:00", "db": "VULMON", "id": "CVE-2019-13929" }, { "date": "2019-10-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-010607" }, { "date": "2019-10-08T00:00:00", "db": "CNNVD", "id": "CNNVD-201910-417" }, { "date": "2019-10-10T14:15:14.860000", "db": "NVD", "id": "CVE-2019-13929" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-10-11T00:00:00", "db": "CNVD", "id": "CNVD-2019-34596" }, { "date": "2020-10-16T00:00:00", "db": "VULMON", "id": "CVE-2019-13929" }, { "date": "2019-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-010607" }, { "date": "2020-10-21T00:00:00", "db": "CNNVD", "id": "CNNVD-201910-417" }, { "date": "2024-11-21T04:25:43.067000", "db": "NVD", "id": "CVE-2019-13929" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201910-417" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SIMATIC IT UADM Password storage vulnerability", "sources": [ { "db": "IVD", "id": "2b632d60-b3f0-452d-a02a-ca327aef1c0b" }, { "db": "CNVD", "id": "CNVD-2019-34596" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "security feature problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-201910-417" } ], "trust": 0.6 } }
fkie_cve-2019-13929
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_it_uadm | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_it_uadm:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D742511-E68B-449B-A70D-00755DBA48C5", "versionEndExcluding": "1.3", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC IT UADM (All versions \u003c V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC IT UADM (Todas las versiones anteriores a V1.3). Un atacante remoto autenticado con acceso de red en puerto 1434/tcp de SIMATIC IT UADM podr\u00eda recuperar una contrase\u00f1a que puede ser usada para conseguir acceso de lectura y escritura en la estaci\u00f3n TeamCenter relacionada. La vulnerabilidad de seguridad podr\u00eda ser explotada solo si el atacante est\u00e1 autenticado. Una interacci\u00f3n del usuario no es requerida para explotar esta vulnerabilidad de seguridad. La explotaci\u00f3n exitosa de la vulnerabilidad de seguridad compromete la confidencialidad del sistema destino. En el momento de la publicaci\u00f3n del aviso, no se conoc\u00eda la explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad." } ], "id": "CVE-2019-13929", "lastModified": "2024-11-21T04:25:43.067", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-10-10T14:15:14.860", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-321" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-330" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
cnvd-2019-34596
Vulnerability from cnvd
用户可参考如下供应商提供的安全公告获得补丁信息: https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf
Name | SIEMENS Siemens SIMATIC IT UADM < 1.3 |
---|
{ "cves": { "cve": { "cveNumber": "CVE-2019-13929", "cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2019-13929" } }, "description": "Siemens SIMATIC IT Unified Architecture Discrete Manufacturing\uff08UADM\uff09\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u4e00\u5957\u5236\u9020\u6267\u884c\u7cfb\u7edf\uff08MES\uff09\u89e3\u51b3\u65b9\u6848\u3002\n\nSiemens SIMATIC IT UADM\u5b58\u5728\u5bc6\u7801\u5b58\u50a8\u6f0f\u6d1e\uff0c\u7ecf\u8eab\u4efd\u9a8c\u8bc1\u7684\u8fdc\u7a0b\u653b\u51fb\u8005\u5229\u7528\u6b64\u6f0f\u6d1e\u53ef\u6062\u590d1434/TCP\u7aef\u53e3\u4e0a\u7684\u5bc6\u7801\uff0c\u4ece\u800c\u83b7\u53d6\u76f8\u5173TeamCenter\u7ad9\u7684\u8bfb\u5199\u8bbf\u95ee\u6743\u9650\u3002", "discovererName": "unknwon", "formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u4f9b\u5e94\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u516c\u544a\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2019-34596", "openTime": "2019-10-11", "patchDescription": "Siemens SIMATIC IT Unified Architecture Discrete Manufacturing\uff08UADM\uff09\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u4e00\u5957\u5236\u9020\u6267\u884c\u7cfb\u7edf\uff08MES\uff09\u89e3\u51b3\u65b9\u6848\u3002\r\n\r\nSiemens SIMATIC IT UADM\u5b58\u5728\u5bc6\u7801\u5b58\u50a8\u6f0f\u6d1e\uff0c\u7ecf\u8eab\u4efd\u9a8c\u8bc1\u7684\u8fdc\u7a0b\u653b\u51fb\u8005\u5229\u7528\u6b64\u6f0f\u6d1e\u53ef\u6062\u590d1434/TCP\u7aef\u53e3\u4e0a\u7684\u5bc6\u7801\uff0c\u4ece\u800c\u83b7\u53d6\u76f8\u5173TeamCenter\u7ad9\u7684\u8bfb\u5199\u8bbf\u95ee\u6743\u9650\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002", "patchName": "Siemens SIMATIC IT UADM\u5bc6\u7801\u5b58\u50a8\u6f0f\u6d1e\u7684\u8865\u4e01", "products": { "product": "SIEMENS Siemens SIMATIC IT UADM \u003c 1.3" }, "referenceLink": "https://nvd.nist.gov/vuln/detail/CVE-2019-13929\r\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf", "serverity": "\u4e2d", "submitTime": "2019-10-09", "title": "Siemens SIMATIC IT UADM\u5bc6\u7801\u5b58\u50a8\u6f0f\u6d1e" }
icsa-19-281-04
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reported this vulnerability to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp" } }, "lang": "en-US", "notes": [ { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s TXT advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protectnetwork access to devices with appropriate mechanisms. In order tooperate the devices in a protected IT environment, Siemens recommends toconfigure the environment according to Siemens\u0027 operational guidelinesfor Industrial Security (Download:https://www.siemens.com/cert/operational-guidelines-industrial-security),and to follow the recommendations in the product manuals.", "title": "General Recommendations" }, { "category": "general", "text": "Additional information on Industrial Security by Siemens can be foundat: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions containedin Siemens\u0027 underlying license terms or other applicable agreements previouslyagreed to with Siemens (hereinafter \"License Terms\"). To the extent applicableto information, software or documentation made available in or through aSiemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website(https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), inparticular Sections 8-10 of the Terms of Use, shall apply additionally. In caseof conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "coordinator", "contact_details": "central@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-984700: Password Storage Vulnerability in SIMATIC IT UADM", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-984700.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-19-281-04 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/refs/heads/develop/csaf_files/OT/white/2019/icsa-19-281-04.json" }, { "category": "self", "summary": "ICSA Advisory ICSA-19-281-04 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-281-04" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "ICSA-19-281-04 Siemens SIMATIC IT UADM", "tracking": { "current_release_date": "2019-10-08T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-19-281-04", "initial_release_date": "2019-10-08T00:00:00.000000Z", "revision_history": [ { "date": "2019-10-08T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV1.3", "product": { "name": "SIMATIC IT UADM", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SIMATIC IT UADM" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2019-13929", "cwe": { "id": "CWE-321", "name": "Use of Hard-coded Cryptographic Key" }, "notes": [ { "category": "summary", "text": "An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-13929" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "mitigation", "details": "Update to V1.3 - Download: SIMATIC IT UADM software can be obtained from your local Siemens account manager.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:UADM software. Protect network access to port 1434/tcp of machines running SIMATIC IT", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:UADM software. Apply cell protection concept and implement Defense-in-Depth.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.8, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
ICSA-19-281-04
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reported this vulnerability to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp" } }, "lang": "en-US", "notes": [ { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s TXT advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protectnetwork access to devices with appropriate mechanisms. In order tooperate the devices in a protected IT environment, Siemens recommends toconfigure the environment according to Siemens\u0027 operational guidelinesfor Industrial Security (Download:https://www.siemens.com/cert/operational-guidelines-industrial-security),and to follow the recommendations in the product manuals.", "title": "General Recommendations" }, { "category": "general", "text": "Additional information on Industrial Security by Siemens can be foundat: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions containedin Siemens\u0027 underlying license terms or other applicable agreements previouslyagreed to with Siemens (hereinafter \"License Terms\"). To the extent applicableto information, software or documentation made available in or through aSiemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website(https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), inparticular Sections 8-10 of the Terms of Use, shall apply additionally. In caseof conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "coordinator", "contact_details": "central@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-984700: Password Storage Vulnerability in SIMATIC IT UADM", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-984700.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-19-281-04 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/refs/heads/develop/csaf_files/OT/white/2019/icsa-19-281-04.json" }, { "category": "self", "summary": "ICSA Advisory ICSA-19-281-04 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-281-04" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "ICSA-19-281-04 Siemens SIMATIC IT UADM", "tracking": { "current_release_date": "2019-10-08T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-19-281-04", "initial_release_date": "2019-10-08T00:00:00.000000Z", "revision_history": [ { "date": "2019-10-08T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV1.3", "product": { "name": "SIMATIC IT UADM", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SIMATIC IT UADM" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2019-13929", "cwe": { "id": "CWE-321", "name": "Use of Hard-coded Cryptographic Key" }, "notes": [ { "category": "summary", "text": "An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-13929" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "mitigation", "details": "Update to V1.3 - Download: SIMATIC IT UADM software can be obtained from your local Siemens account manager.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:UADM software. Protect network access to port 1434/tcp of machines running SIMATIC IT", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:UADM software. Apply cell protection concept and implement Defense-in-Depth.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.8, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
ghsa-8r46-6p4v-4rq3
Vulnerability from github
A vulnerability has been identified in SIMATIC IT UADM (All versions < V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
{ "affected": [], "aliases": [ "CVE-2019-13929" ], "database_specific": { "cwe_ids": [], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2019-10-10T14:15:00Z", "severity": "MODERATE" }, "details": "A vulnerability has been identified in SIMATIC IT UADM (All versions \u003c V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.", "id": "GHSA-8r46-6p4v-4rq3", "modified": "2022-05-24T16:58:31Z", "published": "2022-05-24T16:58:31Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2019-13929" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf" } ], "schema_version": "1.4.0", "severity": [] }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.