Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2019-13922 (GCVE-0-2019-13922)
Vulnerability from cvelistv5
- CWE-311 - Missing Encryption of Sensitive Data
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf | Patch, Vendor Advisory |
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens AG | SINEMA Remote Connect Server |
Version: All versions < V2.0 SP1 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T00:05:43.995Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SINEMA Remote Connect Server", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0 SP1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device\u0027s password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-311", "description": "CWE-311: Missing Encryption of Sensitive Data", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-09-13T16:38:32", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-13922", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SINEMA Remote Connect Server", "version": { "version_data": [ { "version_value": "All versions \u003c V2.0 SP1" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device\u0027s password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-311: Missing Encryption of Sensitive Data" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-13922", "datePublished": "2019-09-13T16:38:32", "dateReserved": "2019-07-18T00:00:00", "dateUpdated": "2024-08-05T00:05:43.995Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2019-13922\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2019-09-13T17:15:11.927\",\"lastModified\":\"2024-11-21T04:25:42.320\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device\u0027s password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SINEMA Remote Connect Server (Todas las versiones anteriores a V2.0 SP1). Un atacante con privilegios administrativos puede obtener el hash de contrase\u00f1a de un dispositivo conectado. La vulnerabilidad de seguridad podr\u00eda ser explotada por un atacante con acceso de red al SINEMA Remote Connect Server y a privilegios administrativos. Al momento de la publicaci\u00f3n de asesoramiento, no se conoc\u00eda una explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":2.7,\"baseSeverity\":\"LOW\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.2,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:N/A:N\",\"baseScore\":4.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-311\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-311\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.0\",\"matchCriteriaId\":\"380C606D-43A0-4362-9A5E-BC7320890196\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinema_remote_connect_server:2.0:hf1:*:*:*:*:*:*\",\"matchCriteriaId\":\"33B706BB-C3D7-4BAA-A140-A7AF962F7141\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}" } }
ghsa-gr98-g82j-6qxx
Vulnerability from github
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device's password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known.
{ "affected": [], "aliases": [ "CVE-2019-13922" ], "database_specific": { "cwe_ids": [ "CWE-311" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2019-09-13T17:15:00Z", "severity": "MODERATE" }, "details": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device\u0027s password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known.", "id": "GHSA-gr98-g82j-6qxx", "modified": "2022-05-24T16:56:10Z", "published": "2022-05-24T16:56:10Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2019-13922" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf" } ], "schema_version": "1.4.0", "severity": [] }
gsd-2019-13922
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2019-13922", "description": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device\u0027s password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known.", "id": "GSD-2019-13922" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2019-13922" ], "details": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device\u0027s password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known.", "id": "GSD-2019-13922", "modified": "2023-12-13T01:23:41.598310Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-13922", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SINEMA Remote Connect Server", "version": { "version_data": [ { "version_value": "All versions \u003c V2.0 SP1" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device\u0027s password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-311: Missing Encryption of Sensitive Data" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "2.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:sinema_remote_connect_server:2.0:hf1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-13922" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device\u0027s password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-311" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf", "refsource": "MISC", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 2.7, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 1.4 } }, "lastModifiedDate": "2021-10-28T16:45Z", "publishedDate": "2019-09-13T17:15Z" } } }
cnvd-2019-31664
Vulnerability from cnvd
Title: Siemens SINEMA Remote Connect Server存在未明漏洞
Description:
Siemens SINEMA Remote Connect Server是一款服务器应用程序。 SINEMA Remote Connect可帮助用户访问远程设备或机器,从而可轻松而且安全地进行维护。
Siemens SINEMA Remote Connect Server存在未明漏洞。具有管理权限的攻击者可以获取连接设备密码的哈希值。
Severity: 中
Patch Name: Siemens SINEMA Remote Connect Server存在未明漏洞的补丁
Patch Description:
Siemens SINEMA Remote Connect Server是一款服务器应用程序。 SINEMA Remote Connect可帮助用户访问远程设备或机器,从而可轻松而且安全地进行维护。
Siemens SINEMA Remote Connect Server存在未明漏洞。具有管理权限的攻击者可以获取连接设备密码的哈希值。目前,供应商发布了安全公告及相关补丁信息,修复了此漏洞。
Formal description:
用户可参考如下供应商提供的安全公告获得补丁信息: https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf
Reference: https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf
Name | SIEMENS SINEMA Remote Connect Server < V2.0 SP1 |
---|
{ "cves": { "cve": { "cveNumber": "CVE-2019-13922" } }, "description": "Siemens SINEMA Remote Connect Server\u662f\u4e00\u6b3e\u670d\u52a1\u5668\u5e94\u7528\u7a0b\u5e8f\u3002 SINEMA Remote Connect\u53ef\u5e2e\u52a9\u7528\u6237\u8bbf\u95ee\u8fdc\u7a0b\u8bbe\u5907\u6216\u673a\u5668\uff0c\u4ece\u800c\u53ef\u8f7b\u677e\u800c\u4e14\u5b89\u5168\u5730\u8fdb\u884c\u7ef4\u62a4\u3002\n\nSiemens SINEMA Remote Connect Server\u5b58\u5728\u672a\u660e\u6f0f\u6d1e\u3002\u5177\u6709\u7ba1\u7406\u6743\u9650\u7684\u653b\u51fb\u8005\u53ef\u4ee5\u83b7\u53d6\u8fde\u63a5\u8bbe\u5907\u5bc6\u7801\u7684\u54c8\u5e0c\u503c\u3002", "discovererName": "Hendrik Derre and Tijl Deneut", "formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u4f9b\u5e94\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u516c\u544a\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2019-31664", "openTime": "2019-09-16", "patchDescription": "Siemens SINEMA Remote Connect Server\u662f\u4e00\u6b3e\u670d\u52a1\u5668\u5e94\u7528\u7a0b\u5e8f\u3002 SINEMA Remote Connect\u53ef\u5e2e\u52a9\u7528\u6237\u8bbf\u95ee\u8fdc\u7a0b\u8bbe\u5907\u6216\u673a\u5668\uff0c\u4ece\u800c\u53ef\u8f7b\u677e\u800c\u4e14\u5b89\u5168\u5730\u8fdb\u884c\u7ef4\u62a4\u3002\r\n\r\nSiemens SINEMA Remote Connect Server\u5b58\u5728\u672a\u660e\u6f0f\u6d1e\u3002\u5177\u6709\u7ba1\u7406\u6743\u9650\u7684\u653b\u51fb\u8005\u53ef\u4ee5\u83b7\u53d6\u8fde\u63a5\u8bbe\u5907\u5bc6\u7801\u7684\u54c8\u5e0c\u503c\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002", "patchName": "Siemens SINEMA Remote Connect Server\u5b58\u5728\u672a\u660e\u6f0f\u6d1e\u7684\u8865\u4e01", "products": { "product": "SIEMENS SINEMA Remote Connect Server \u003c V2.0 SP1" }, "referenceLink": "https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf", "serverity": "\u4e2d", "submitTime": "2019-09-11", "title": "Siemens SINEMA Remote Connect Server\u5b58\u5728\u672a\u660e\u6f0f\u6d1e" }
var-201909-1515
Vulnerability from variot
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device's password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known. The platform is mainly used for remote access, maintenance, control and diagnosis of the underlying network
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201909-1515", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "sinema remote connect server", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "sinema remote connect server", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "sinema remote connect server", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "2.0 sp1" }, { "model": "sinema remote connect server sp1", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v2.0" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinema remote connect server", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinema remote connect server", "version": "2.0" } ], "sources": [ { "db": "IVD", "id": "6b4a2986-7677-4b8f-b189-40319f7d3fed" }, { "db": "CNVD", "id": "CNVD-2019-31664" }, { "db": "JVNDB", "id": "JVNDB-2019-009305" }, { "db": "NVD", "id": "CVE-2019-13922" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:sinema_remote_connect_server", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-009305" } ] }, "cve": "CVE-2019-13922", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "CVE-2019-13922", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "HIGH", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 6.1, "confidentialityImpact": "NONE", "exploitabilityScore": 4.9, "id": "CNVD-2019-31664", "impactScore": 7.8, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:H/Au:N/C:N/I:P/A:C", "version": "2.0" }, { "accessComplexity": "HIGH", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 6.1, "confidentialityImpact": "NONE", "exploitabilityScore": 4.9, "id": "6b4a2986-7677-4b8f-b189-40319f7d3fed", "impactScore": 7.8, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:N/AC:H/Au:N/C:N/I:P/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "VHN-145817", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:S/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 2.7, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "exploitabilityScore": 1.2, "id": "CVE-2019-13922", "impactScore": 1.4, "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 2.7, "baseSeverity": "Low", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "CVE-2019-13922", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2019-13922", "trust": 1.0, "value": "LOW" }, { "author": "NVD", "id": "CVE-2019-13922", "trust": 0.8, "value": "Low" }, { "author": "CNVD", "id": "CNVD-2019-31664", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201909-681", "trust": 0.6, "value": "LOW" }, { "author": "IVD", "id": "6b4a2986-7677-4b8f-b189-40319f7d3fed", "trust": 0.2, "value": "LOW" }, { "author": "VULHUB", "id": "VHN-145817", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "6b4a2986-7677-4b8f-b189-40319f7d3fed" }, { "db": "CNVD", "id": "CNVD-2019-31664" }, { "db": "VULHUB", "id": "VHN-145817" }, { "db": "JVNDB", "id": "JVNDB-2019-009305" }, { "db": "CNNVD", "id": "CNNVD-201909-681" }, { "db": "NVD", "id": "CVE-2019-13922" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device\u0027s password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known. The platform is mainly used for remote access, maintenance, control and diagnosis of the underlying network", "sources": [ { "db": "NVD", "id": "CVE-2019-13922" }, { "db": "JVNDB", "id": "JVNDB-2019-009305" }, { "db": "CNVD", "id": "CNVD-2019-31664" }, { "db": "IVD", "id": "6b4a2986-7677-4b8f-b189-40319f7d3fed" }, { "db": "VULHUB", "id": "VHN-145817" } ], "trust": 2.43 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-13922", "trust": 3.3 }, { "db": "SIEMENS", "id": "SSA-884497", "trust": 2.3 }, { "db": "ICS CERT", "id": "ICSA-19-260-02", "trust": 1.4 }, { "db": "CNNVD", "id": "CNNVD-201909-681", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2019-31664", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2019-009305", "trust": 0.8 }, { "db": "AUSCERT", "id": "ESB-2019.3559", "trust": 0.6 }, { "db": "IVD", "id": "6B4A2986-7677-4B8F-B189-40319F7D3FED", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-145817", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "6b4a2986-7677-4b8f-b189-40319f7d3fed" }, { "db": "CNVD", "id": "CNVD-2019-31664" }, { "db": "VULHUB", "id": "VHN-145817" }, { "db": "JVNDB", "id": "JVNDB-2019-009305" }, { "db": "CNNVD", "id": "CNNVD-201909-681" }, { "db": "NVD", "id": "CVE-2019-13922" } ] }, "id": "VAR-201909-1515", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "6b4a2986-7677-4b8f-b189-40319f7d3fed" }, { "db": "CNVD", "id": "CNVD-2019-31664" }, { "db": "VULHUB", "id": "VHN-145817" } ], "trust": 1.5003805 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "6b4a2986-7677-4b8f-b189-40319f7d3fed" }, { "db": "CNVD", "id": "CNVD-2019-31664" } ] }, "last_update_date": "2024-11-23T22:11:49.344000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-884497", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf" }, { "title": "Siemens SINEMA Remote Connect Server has an unexplained patch", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/180409" }, { "title": "SINEMA Remote Connect Server Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=98248" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-31664" }, { "db": "JVNDB", "id": "JVNDB-2019-009305" }, { "db": "CNNVD", "id": "CNNVD-201909-681" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-311", "trust": 1.0 }, { "problemtype": "CWE-916", "trust": 0.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-145817" }, { "db": "JVNDB", "id": "JVNDB-2019-009305" }, { "db": "NVD", "id": "CVE-2019-13922" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf" }, { "trust": 1.4, "url": "https://www.us-cert.gov/ics/advisories/icsa-19-260-02" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-13922" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-13922" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2019.3559/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-31664" }, { "db": "VULHUB", "id": "VHN-145817" }, { "db": "JVNDB", "id": "JVNDB-2019-009305" }, { "db": "CNNVD", "id": "CNNVD-201909-681" }, { "db": "NVD", "id": "CVE-2019-13922" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "6b4a2986-7677-4b8f-b189-40319f7d3fed" }, { "db": "CNVD", "id": "CNVD-2019-31664" }, { "db": "VULHUB", "id": "VHN-145817" }, { "db": "JVNDB", "id": "JVNDB-2019-009305" }, { "db": "CNNVD", "id": "CNNVD-201909-681" }, { "db": "NVD", "id": "CVE-2019-13922" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-09-16T00:00:00", "db": "IVD", "id": "6b4a2986-7677-4b8f-b189-40319f7d3fed" }, { "date": "2019-09-16T00:00:00", "db": "CNVD", "id": "CNVD-2019-31664" }, { "date": "2019-09-13T00:00:00", "db": "VULHUB", "id": "VHN-145817" }, { "date": "2019-09-18T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-009305" }, { "date": "2019-09-13T00:00:00", "db": "CNNVD", "id": "CNNVD-201909-681" }, { "date": "2019-09-13T17:15:11.927000", "db": "NVD", "id": "CVE-2019-13922" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-09-16T00:00:00", "db": "CNVD", "id": "CNVD-2019-31664" }, { "date": "2019-10-09T00:00:00", "db": "VULHUB", "id": "VHN-145817" }, { "date": "2019-09-18T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-009305" }, { "date": "2021-10-29T00:00:00", "db": "CNNVD", "id": "CNNVD-201909-681" }, { "date": "2024-11-21T04:25:42.320000", "db": "NVD", "id": "CVE-2019-13922" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201909-681" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "SINEMA Remote Connect Server Vulnerabilities in the use of weak password hashes", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-009305" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "IVD", "id": "6b4a2986-7677-4b8f-b189-40319f7d3fed" }, { "db": "CNNVD", "id": "CNNVD-201909-681" } ], "trust": 0.8 } }
icsa-19-260-02
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reported this vulnerability to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp" } }, "lang": "en-US", "notes": [ { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s TXT advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protectnetwork access to devices with appropriate mechanisms. In order tooperate the devices in a protected IT environment, Siemens recommends toconfigure the environment according to Siemens\u0027 operational guidelinesfor Industrial Security (Download:https://www.siemens.com/cert/operational-guidelines-industrial-security),and to follow the recommendations in the product manuals.", "title": "General Recommendations" }, { "category": "general", "text": "Additional information on Industrial Security by Siemens can be foundat: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions containedin Siemens\u0027 underlying license terms or other applicable agreements previouslyagreed to with Siemens (hereinafter \"License Terms\"). To the extent applicableto information, software or documentation made available in or through aSiemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website(https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), inparticular Sections 8-10 of the Terms of Use, shall apply additionally. In caseof conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "coordinator", "contact_details": "central@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-884497: Multiple Vulnerabilities in SINEMA Remote Connect Server", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-884497.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-19-260-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/refs/heads/develop/csaf_files/OT/white/2019/icsa-19-260-02.json" }, { "category": "self", "summary": "ICSA Advisory ICSA-19-260-02 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-260-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "ICSA-19-260-02 Siemens SINEMA Remote Connect Server", "tracking": { "current_release_date": "2019-09-10T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-19-260-02", "initial_release_date": "2019-09-10T00:00:00.000000Z", "revision_history": [ { "date": "2019-09-10T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV2.0_SP1", "product": { "name": "SINEMA Remote Connect Server", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SINEMA Remote Connect Server" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2019-13918", "cwe": { "id": "CWE-307", "name": "Improper Restriction of Excessive Authentication Attempts" }, "notes": [ { "category": "summary", "text": "The web interface has no means to prevent password guessing attacks. The vulnerability could be exploited by an attacker with network access to the vulnerable software, requiring no privileges and no user interaction. The vulnerability could allow full access to the web interface. At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-13918" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 SP1 - Download: https://support.industry.siemens.com/cs/ww/en/view/109770899", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109770899" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:Remote Connect Restrict network access to the SINEMA Remote Connect web interface", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:Remote Connect Do not access links from untrusted sources while logged in at SINEMA", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2019-13919", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "Some pages that should only be accessible by a privileged user can also be accessed by a non-privileged user. The security vulnerability could be exploited by an attacker with network access and valid credentials for the web interface. No user interaction is required. The vulnerability could allow an attacker to access information that he should not be able to read. The affected information does not include passwords. At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-13919" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 SP1 - Download: https://support.industry.siemens.com/cs/ww/en/view/109770899", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109770899" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:Remote Connect Restrict network access to the SINEMA Remote Connect web interface", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:Remote Connect Do not access links from untrusted sources while logged in at SINEMA", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2019-13920", "cwe": { "id": "CWE-352", "name": "Cross-Site Request Forgery (CSRF)" }, "notes": [ { "category": "summary", "text": "Some parts of the web application are not protected against Cross Site Request Forgery (CSRF) attacks. The security vulnerability could be exploited by an attacker that is able to trigger requests of a logged-in user to the application. The vulnerability could allow switching the connectivity state of a user or a device. At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-13920" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:N/I:L/A:N/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 SP1 - Download: https://support.industry.siemens.com/cs/ww/en/view/109770899", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109770899" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:Remote Connect Restrict network access to the SINEMA Remote Connect web interface", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:Remote Connect Do not access links from untrusted sources while logged in at SINEMA", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.4, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2019-13922", "cwe": { "id": "CWE-311", "name": "Missing Encryption of Sensitive Data" }, "notes": [ { "category": "summary", "text": "An attacker with administrative privileges can obtain the hash of a connected device\u0027s password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-13922" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:C/C:N/I:L/A:H/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 SP1 - Download: https://support.industry.siemens.com/cs/ww/en/view/109770899", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109770899" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:Remote Connect Restrict network access to the SINEMA Remote Connect web interface", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:Remote Connect Do not access links from untrusted sources while logged in at SINEMA", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:C/C:N/I:L/A:H/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
ICSA-19-260-02
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reported this vulnerability to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp" } }, "lang": "en-US", "notes": [ { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s TXT advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protectnetwork access to devices with appropriate mechanisms. In order tooperate the devices in a protected IT environment, Siemens recommends toconfigure the environment according to Siemens\u0027 operational guidelinesfor Industrial Security (Download:https://www.siemens.com/cert/operational-guidelines-industrial-security),and to follow the recommendations in the product manuals.", "title": "General Recommendations" }, { "category": "general", "text": "Additional information on Industrial Security by Siemens can be foundat: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions containedin Siemens\u0027 underlying license terms or other applicable agreements previouslyagreed to with Siemens (hereinafter \"License Terms\"). To the extent applicableto information, software or documentation made available in or through aSiemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website(https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), inparticular Sections 8-10 of the Terms of Use, shall apply additionally. In caseof conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "coordinator", "contact_details": "central@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-884497: Multiple Vulnerabilities in SINEMA Remote Connect Server", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-884497.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-19-260-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/refs/heads/develop/csaf_files/OT/white/2019/icsa-19-260-02.json" }, { "category": "self", "summary": "ICSA Advisory ICSA-19-260-02 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-260-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "ICSA-19-260-02 Siemens SINEMA Remote Connect Server", "tracking": { "current_release_date": "2019-09-10T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-19-260-02", "initial_release_date": "2019-09-10T00:00:00.000000Z", "revision_history": [ { "date": "2019-09-10T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV2.0_SP1", "product": { "name": "SINEMA Remote Connect Server", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SINEMA Remote Connect Server" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2019-13918", "cwe": { "id": "CWE-307", "name": "Improper Restriction of Excessive Authentication Attempts" }, "notes": [ { "category": "summary", "text": "The web interface has no means to prevent password guessing attacks. The vulnerability could be exploited by an attacker with network access to the vulnerable software, requiring no privileges and no user interaction. The vulnerability could allow full access to the web interface. At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-13918" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 SP1 - Download: https://support.industry.siemens.com/cs/ww/en/view/109770899", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109770899" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:Remote Connect Restrict network access to the SINEMA Remote Connect web interface", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:Remote Connect Do not access links from untrusted sources while logged in at SINEMA", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2019-13919", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "Some pages that should only be accessible by a privileged user can also be accessed by a non-privileged user. The security vulnerability could be exploited by an attacker with network access and valid credentials for the web interface. No user interaction is required. The vulnerability could allow an attacker to access information that he should not be able to read. The affected information does not include passwords. At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-13919" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 SP1 - Download: https://support.industry.siemens.com/cs/ww/en/view/109770899", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109770899" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:Remote Connect Restrict network access to the SINEMA Remote Connect web interface", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:Remote Connect Do not access links from untrusted sources while logged in at SINEMA", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2019-13920", "cwe": { "id": "CWE-352", "name": "Cross-Site Request Forgery (CSRF)" }, "notes": [ { "category": "summary", "text": "Some parts of the web application are not protected against Cross Site Request Forgery (CSRF) attacks. The security vulnerability could be exploited by an attacker that is able to trigger requests of a logged-in user to the application. The vulnerability could allow switching the connectivity state of a user or a device. At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-13920" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:N/I:L/A:N/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 SP1 - Download: https://support.industry.siemens.com/cs/ww/en/view/109770899", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109770899" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:Remote Connect Restrict network access to the SINEMA Remote Connect web interface", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:Remote Connect Do not access links from untrusted sources while logged in at SINEMA", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.4, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2019-13922", "cwe": { "id": "CWE-311", "name": "Missing Encryption of Sensitive Data" }, "notes": [ { "category": "summary", "text": "An attacker with administrative privileges can obtain the hash of a connected device\u0027s password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-13922" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:C/C:N/I:L/A:H/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.0 SP1 - Download: https://support.industry.siemens.com/cs/ww/en/view/109770899", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109770899" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:Remote Connect Restrict network access to the SINEMA Remote Connect web interface", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:Remote Connect Do not access links from untrusted sources while logged in at SINEMA", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:C/C:N/I:L/A:H/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
fkie_cve-2019-13922
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf | Patch, Vendor Advisory |
Vendor | Product | Version | |
---|---|---|---|
siemens | sinema_remote_connect_server | * | |
siemens | sinema_remote_connect_server | 2.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "380C606D-43A0-4362-9A5E-BC7320890196", "versionEndIncluding": "2.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:2.0:hf1:*:*:*:*:*:*", "matchCriteriaId": "33B706BB-C3D7-4BAA-A140-A7AF962F7141", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device\u0027s password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SINEMA Remote Connect Server (Todas las versiones anteriores a V2.0 SP1). Un atacante con privilegios administrativos puede obtener el hash de contrase\u00f1a de un dispositivo conectado. La vulnerabilidad de seguridad podr\u00eda ser explotada por un atacante con acceso de red al SINEMA Remote Connect Server y a privilegios administrativos. Al momento de la publicaci\u00f3n de asesoramiento, no se conoc\u00eda una explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad." } ], "id": "CVE-2019-13922", "lastModified": "2024-11-21T04:25:42.320", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 2.7, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 1.4, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-09-13T17:15:11.927", "references": [ { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-311" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-311" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.