CVE-2019-13537 (GCVE-0-2019-13537)
Vulnerability from cvelistv5
Published
2020-01-14 18:05
Modified
2024-08-04 23:57
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - STACK-BASED BUFFER OVERFLOW
Summary
The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash.
References
| URL | Tags | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| AVEVA | Vijeo Citect and Citect SCADA |
Version: IEC870IP driver v4.14.02 and prior |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:57:39.424Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-290-01"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityBulletin_LFSec139.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Vijeo Citect and Citect SCADA",
"vendor": "AVEVA",
"versions": [
{
"status": "affected",
"version": "IEC870IP driver v4.14.02 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The IEC870IP driver for AVEVA\u2019s Vijeo Citect and Citect SCADA and Schneider Electric\u2019s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "STACK-BASED BUFFER OVERFLOW CWE-121",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-14T18:05:51",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-290-01"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityBulletin_LFSec139.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2019-13537",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Vijeo Citect and Citect SCADA",
"version": {
"version_data": [
{
"version_value": "IEC870IP driver v4.14.02 and prior"
}
]
}
}
]
},
"vendor_name": "AVEVA"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The IEC870IP driver for AVEVA\u2019s Vijeo Citect and Citect SCADA and Schneider Electric\u2019s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "STACK-BASED BUFFER OVERFLOW CWE-121"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-290-01",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-290-01"
},
{
"name": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityBulletin_LFSec139.pdf",
"refsource": "CONFIRM",
"url": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityBulletin_LFSec139.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2019-13537",
"datePublished": "2020-01-14T18:05:51",
"dateReserved": "2019-07-11T00:00:00",
"dateUpdated": "2024-08-04T23:57:39.424Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2019-13537\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2020-01-14T19:15:12.907\",\"lastModified\":\"2024-11-21T04:25:06.097\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The IEC870IP driver for AVEVA\u2019s Vijeo Citect and Citect SCADA and Schneider Electric\u2019s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash.\"},{\"lang\":\"es\",\"value\":\"El controlador IEC870IP para Vijeo Citect y Citect SCADA de AVEVA y la operaci\u00f3n Power SCADA de Schneider Electric tiene una vulnerabilidad de desbordamiento del b\u00fafer que podr\u00eda provocar un bloqueo del lado del servidor.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:aveva:iec870ip_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.14.02\",\"matchCriteriaId\":\"471C2A7F-ED41-4ABA-B6E9-F962574058C2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:aveva:iec870ip:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6E7B4856-0A64-4C1A-ADC6-120A9AD86176\"}]}]}],\"references\":[{\"url\":\"https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityBulletin_LFSec139.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-19-290-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityBulletin_LFSec139.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-19-290-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…