CVE-2018-7810 (GCVE-0-2018-7810)
Vulnerability from cvelistv5
Published
2018-11-30 19:00
Modified
2024-08-05 06:37
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to craft a URL containing JavaScript that will be executed within the user's browser, potentially impacting the machine the browser is running on.
References
URL | Tags | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric SE | Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 |
Version: Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T06:37:59.377Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.tenable.com/security/research/tra-2018-38" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-327-01/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200", "vendor": "Schneider Electric SE", "versions": [ { "status": "affected", "version": "Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200" } ] } ], "datePublic": "2018-11-30T00:00:00", "descriptions": [ { "lang": "en", "value": "An Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to craft a URL containing JavaScript that will be executed within the user\u0027s browser, potentially impacting the machine the browser is running on." } ], "problemTypes": [ { "descriptions": [ { "description": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-12-01T10:57:01", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.tenable.com/security/research/tra-2018-38" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-327-01/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2018-7810", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200", "version": { "version_data": [ { "version_value": "Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200" } ] } } ] }, "vendor_name": "Schneider Electric SE" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to craft a URL containing JavaScript that will be executed within the user\u0027s browser, potentially impacting the machine the browser is running on." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.tenable.com/security/research/tra-2018-38", "refsource": "MISC", "url": "https://www.tenable.com/security/research/tra-2018-38" }, { "name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-327-01/", "refsource": "CONFIRM", "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-327-01/" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2018-7810", "datePublished": "2018-11-30T19:00:00", "dateReserved": "2018-03-08T00:00:00", "dateUpdated": "2024-08-05T06:37:59.377Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2018-7810\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2018-11-30T19:29:00.470\",\"lastModified\":\"2024-11-21T04:12:46.470\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to craft a URL containing JavaScript that will be executed within the user\u0027s browser, potentially impacting the machine the browser is running on.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de neutralizaci\u00f3n indebida de entradas durante la generaci\u00f3n de p\u00e1ginas web (\\\"Cross-Site Scripting\\\") en los servidores web embebidos en todos los productos Modicon M340, Premium, Quantum PLCs y BMXNOR0200, lo que podr\u00eda permitir que un atacante manipule una URL que contiene JavaScript, que se ejecutar\u00e1 en el navegador del usuario, teniendo un impacto potencial en la m\u00e1quina en la que se est\u00e1 ejecutando el navegador.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicom_m340_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A53C0B78-6556-44B7-9546-75F48EDD87CB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicom_m340:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7F3D3249-CD51-496E-AB39-79D53EB318F8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicom_premium_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AA79EF8E-C525-4CCB-AC21-F7493FA55BF7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicom_premium:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8BAD47C7-A8D1-44B3-9917-D5285E63F3B5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicom_quantum_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"62BAE494-82C9-4CC7-8149-37DD1ADA10F2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicom_quantum:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1B17B062-016A-45C2-A640-C8FD31E6E05F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicom_bmxnor0200h_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D99FE33D-BBA0-40B7-B79C-E276BF8353FB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicom_bmxnor0200h:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8C420C7F-5B35-4775-8775-241FDD0B759C\"}]}]}],\"references\":[{\"url\":\"https://www.schneider-electric.com/en/download/document/SEVD-2018-327-01/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.tenable.com/security/research/tra-2018-38\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.schneider-electric.com/en/download/document/SEVD-2018-327-01/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.tenable.com/security/research/tra-2018-38\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…