Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | http://www.securityfocus.com/bid/105922 | Third Party Advisory, VDB Entry | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/105922 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens AG | SIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI Comfort Outdoor Panels 7" & 15", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) |
Version: SIMATIC HMI Comfort Panels 4" - 22" : All versions < V15 Update 4 Version: SIMATIC HMI Comfort Outdoor Panels 7" & 15" : All versions < V15 Update 4 Version: SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F : All versions < V15 Update 4 Version: SIMATIC WinCC Runtime Advanced : All versions < V15 Update 4 Version: SIMATIC WinCC Runtime Professional : All versions < V15 Update 4 Version: SIMATIC WinCC (TIA Portal) : All versions < V15 Update 4 Version: SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) : All versions |
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-05T09:14:47.263Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { name: "105922", tags: [ "vdb-entry", "x_refsource_BID", "x_transferred", ], url: "http://www.securityfocus.com/bid/105922", }, { tags: [ "x_refsource_CONFIRM", "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { product: "SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" & 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)", vendor: "Siemens AG", versions: [ { status: "affected", version: "SIMATIC HMI Comfort Panels 4\" - 22\" : All versions < V15 Update 4", }, { status: "affected", version: "SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" : All versions < V15 Update 4", }, { status: "affected", version: "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F : All versions < V15 Update 4", }, { status: "affected", version: "SIMATIC WinCC Runtime Advanced : All versions < V15 Update 4", }, { status: "affected", version: "SIMATIC WinCC Runtime Professional : All versions < V15 Update 4", }, { status: "affected", version: "SIMATIC WinCC (TIA Portal) : All versions < V15 Update 4", }, { status: "affected", version: "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) : All versions", }, ], }, ], datePublic: "2018-12-13T00:00:00", descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.", }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-601", description: "CWE-601: URL Redirection to Untrusted Site ('Open Redirect')", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2018-12-14T10:57:02", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { name: "105922", tags: [ "vdb-entry", "x_refsource_BID", ], url: "http://www.securityfocus.com/bid/105922", }, { tags: [ "x_refsource_CONFIRM", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf", }, ], x_legacyV4Record: { CVE_data_meta: { ASSIGNER: "productcert@siemens.com", ID: "CVE-2018-13813", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" & 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)", version: { version_data: [ { version_value: "SIMATIC HMI Comfort Panels 4\" - 22\" : All versions < V15 Update 4", }, { version_value: "SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" : All versions < V15 Update 4", }, { version_value: "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F : All versions < V15 Update 4", }, { version_value: "SIMATIC WinCC Runtime Advanced : All versions < V15 Update 4", }, { version_value: "SIMATIC WinCC Runtime Professional : All versions < V15 Update 4", }, { version_value: "SIMATIC WinCC (TIA Portal) : All versions < V15 Update 4", }, { version_value: "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) : All versions", }, ], }, }, ], }, vendor_name: "Siemens AG", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "eng", value: "CWE-601: URL Redirection to Untrusted Site ('Open Redirect')", }, ], }, ], }, references: { reference_data: [ { name: "105922", refsource: "BID", url: "http://www.securityfocus.com/bid/105922", }, { name: "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf", refsource: "CONFIRM", url: "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf", }, ], }, }, }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2018-13813", datePublished: "2018-12-13T16:00:00", dateReserved: "2018-07-10T00:00:00", dateUpdated: "2024-08-05T09:14:47.263Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", "vulnerability-lookup:meta": { nvd: "{\"cve\":{\"id\":\"CVE-2018-13813\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2018-12-13T16:29:00.320\",\"lastModified\":\"2024-11-21T03:48:07.380\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\\\" - 22\\\" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\\\" & 15\\\" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Panels 4\\\" - 22\\\" (todas las versiones anteriores a V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\\\" 15\\\" (todas las versiones anteriores a V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 y KTP900F (todas las versiones anteriores a V15 Update 4), SIMATIC WinCC Runtime Advanced (todas las versiones anteriores a V15 Update 4), SIMATIC WinCC Runtime Professional (todas las versiones anteriores a V15 Update 4), SIMATIC WinCC (TIA Portal) (todas las versiones anteriores a V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (todas las versiones). El servidor web de los dispositivos HMI podría permitir redirecciones de URL a sitios web no fiables. Un atacante debe engañar a un usuario válido autenticado en el dispositivo para que haga clic en un enlace malicioso y explote esta vulnerabilidad. En el momento de la publicación del aviso, no se conoce ninguna explotación pública de la vulnerabilidad de seguridad.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":5.2}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:N\",\"baseScore\":5.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-601\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-601\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"15.0\",\"matchCriteriaId\":\"3AD9AEE0-437E-45C7-BA3C-696628FA6883\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3BCFE761-35C9-43EF-85BC-E8083B9F75CB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"15.0\",\"matchCriteriaId\":\"C6D3259C-2DAF-4136-BAC3-28B234329E27\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F4830E0D-0128-4E5B-AB81-2B238471AE4B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"15.0\",\"matchCriteriaId\":\"1D090C01-A7A7-43C2-842F-50951D75B57A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F106DEE3-4DED-46E4-9661-9D9C7B729BC0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"15.0\",\"matchCriteriaId\":\"CE04B9B4-EFFF-447D-9D98-80EE43E926E9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D175BC55-2EAA-4D4A-9E05-2FBB228160F1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"15.0\",\"matchCriteriaId\":\"8B1F081F-E97A-445B-B6D5-E0AEFA3360C1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5C39166C-38CA-426F-9702-B9CA5ED6630C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"15.0\",\"matchCriteriaId\":\"7027573E-5E1E-4750-98AD-AC82DC5C1708\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D29338CD-57BD-4734-9204-118EA53D42FB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"15.0\",\"matchCriteriaId\":\"0B26872E-A514-4CD7-98C9-2F8B6FD3DEEB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9E7858AB-F89E-4E50-8873-DE8F5F2A07CB\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_\\\\(tia_portal\\\\):*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"15.0\",\"matchCriteriaId\":\"775A5747-AB92-4E27-9A74-7DF5368A5BA9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:*\",\"versionEndIncluding\":\"15.0\",\"matchCriteriaId\":\"5D1FBC31-3165-4057-A615-536D73A75311\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:*\",\"versionEndIncluding\":\"15.0\",\"matchCriteriaId\":\"92C7789F-1646-485A-9889-5AD81B5F1105\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_tp_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"983886F3-5B11-4AC3-A4D9-C2816F9A37DF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_tp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EE8F082D-04C4-4A3E-B3D1-6C2914C2917E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_mp_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A2271FBE-FF50-4614-A4A5-BBAB800F5FBD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_mp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"68C30B3C-90EF-4244-9235-D87A421850DC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_op_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"217870AC-9EB0-4BDE-A2E2-381055B8E69C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_op:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A17F4CDF-5367-4343-AA1E-0C452495E598\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/105922\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/105922\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}", }, }
Log in or create an account to share your comment.
Security Advisory comment format.
This schema specifies the format of a comment related to a security advisory.
Title of the comment
Description of the comment
Loading…
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.