CVE-2017-7969 (GCVE-0-2017-7969)
Vulnerability from cvelistv5
- Cross Site Request Forgery
| URL | Tags | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric SE | PowerSCADA Anywhere |
Version: Version 1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:19:29.450Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "99913",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/99913"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PowerSCADA Anywhere",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "Version 1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2"
}
]
},
{
"product": "Citect Anywhere",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "version 1.0"
}
]
}
],
"datePublic": "2017-06-22T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric\u0027s PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Cross Site Request Forgery",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-09-26T09:57:01",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"name": "99913",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/99913"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2017-06-22T00:00:00",
"ID": "CVE-2017-7969",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PowerSCADA Anywhere",
"version": {
"version_data": [
{
"version_value": "Version 1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2"
}
]
}
},
{
"product_name": "Citect Anywhere",
"version": {
"version_data": [
{
"version_value": "version 1.0"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric\u0027s PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Cross Site Request Forgery"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "99913",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/99913"
},
{
"name": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere",
"refsource": "CONFIRM",
"url": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere"
},
{
"name": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/",
"refsource": "CONFIRM",
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2017-7969",
"datePublished": "2017-09-25T19:00:00Z",
"dateReserved": "2017-04-19T00:00:00",
"dateUpdated": "2024-09-17T01:30:49.504Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2017-7969\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2017-09-26T01:29:03.460\",\"lastModified\":\"2025-04-20T01:37:25.860\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric\u0027s PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de Cross-Site Request Forgery (CSRF) en el componente Secure Gateway de PowerSCADA Anywhere v1.0 redistribuido con PowerSCADA Expert v8.1 y PowerSCADA Expert v8.2 y Citect Anywhere versi\u00f3n 1.0, de Schneider Electric para m\u00faltiples peticiones de cambio de estado. Este tipo de ataque requiere cierto nivel de ingenier\u00eda social para conseguir que un usuario leg\u00edtimo haga clic o acceda a un enlace o p\u00e1gina maliciosa que contenga el ataque CSRF.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-352\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:powerscada_anywhere:1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6445511E-70B8-4E03-A178-FFDBE02E1609\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:a:schneider-electric:powerscada_expert:8.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AE171A71-B1AF-471B-9D27-07D4491D05B3\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:a:schneider-electric:powerscada_expert:8.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D2A3FA74-D201-41AA-BDA1-82816813AD11\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:citect_anywhere:1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5182F21D-1DF5-492A-9A3D-B913AC6B12F6\"}]}]}],\"references\":[{\"url\":\"http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Mitigation\",\"Patch\",\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/99913\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Issue Tracking\",\"Mitigation\",\"Patch\",\"Vendor Advisory\"]},{\"url\":\"http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Patch\",\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/99913\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Issue Tracking\",\"Mitigation\",\"Patch\",\"Vendor Advisory\"]}]}}"
}
}
ICSA-17-201-01
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Schneider Electric",
"summary": "notifying ICS-CERT of these vulnerabilities after they made the fixes available"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "ATTENTION: Remotely exploitable/low skill level to exploit.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Commercial Facilities",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Paris, France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "NCCIC/ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available in the ICS -CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target these vulnerabilities.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-17-201-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2017/icsa-17-201-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-17-201-01 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-201-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-201-01"
}
],
"title": "Schneider Electric PowerSCADA Anywhere and Citect Anywhere",
"tracking": {
"current_release_date": "2017-07-20T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-17-201-01",
"initial_release_date": "2017-07-20T00:00:00.000000Z",
"revision_history": [
{
"date": "2017-07-20T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version",
"name": "1.0",
"product": {
"name": "Citect Anywhere: version 1.0",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Citect Anywhere"
},
{
"branches": [
{
"category": "product_version",
"name": "1.0",
"product": {
"name": "PowerSCADA Anywhere redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2: Version 1.0",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "PowerSCADA Anywhere redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2"
}
],
"category": "vendor",
"name": "Schneider Electric Software, LLC"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2017-7969",
"cwe": {
"id": "CWE-352",
"name": "Cross-Site Request Forgery (CSRF)"
},
"notes": [
{
"category": "summary",
"text": "The secure gateway component of the affected products is vulnerable to CSRF for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack.CVE-2017-7969 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-7969"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric strongly recommends that users upgrade their systems as soon as possible. The following provides links to instructions for addressing software that is at potential risk for the vulnerabilities:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "PowerSCADA Anywhere Version 1 used with PowerSCADA Expert v8.2 and PowerSCADA Expert v8.1: Uninstall PowerSCADA Anywhere (from Add/Remove Programs). Then install PowerSCADA Anywhere Version 1.1 available in the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://schneider-electric.box.com/shared/static/3tvcc115kax8volhd8i13e4wg5k1sdel.iso"
},
{
"category": "mitigation",
"details": "Citect Anywhere version 1.1:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.citect.schneider-electric.com/scada/citectscada/downloads-updates/product-downloads?tab=extra_products"
},
{
"category": "mitigation",
"details": "In addition to installing the provided security patch, Schneider Electric recommends that the following steps be taken to further harden the system:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Configure the HTTP origin header whitelist to match the environment\u0027s URL(s) used for accessing the secure gateway. This address may be one or more of the IP, machine name, or domain name where the secure gateway is hosted. The address may also be that of a load balancer or proxy, if the secure gateway is deployed that way.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Configure the secure gateway\u0027s whitelists to restrict access to expected client IPs, as well as to restrict access from the secure gateway to only expected internal server hosts. For an additional defense-in-depth layer, users can further use the Windows OS-level firewall (or zone firewalls) to restrict communication among only the expected nodes.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "If using self-signed certificates, configure the secure gateway machine to trust the server certificate.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Depending on the organization\u0027s requirements, users can further configure the secure gateway to restrict the usable TLS protocols. For an additional defense-in-depth layer, TLS protocols and cipher suites can also be restricted at the operating system level through the use of third party tools such as IISCrypto.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Create unique user accounts with minimal privileges dedicated to accessing applications remotely. OS group policy objects can be used to further restrict what those unique user accounts are allowed to do. For an example configuration that disables task manager from being launched in a remote app connection, follow the steps available here:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://social.technet.microsoft.com/Forums/office/en-US/35dd3cd6-cc67-476f-82e2-058293e6f657/how-do-i-disable-task-manager-for-users-only?forum=winserverTS"
},
{
"category": "mitigation",
"details": "For more information about the vulnerabilities and patch in PowerSCADA Anywhere, please refer to Schneider Electric Security Notification - PowerSCADA Anywhere SEVD-2017-173-01, which is available at the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"
},
{
"category": "mitigation",
"details": "For more information about the vulnerabilities and patch in Citect Anywhere, please refer to Schneider Electric Security Notification - Citect Anywhere, which is available at the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.citect.schneider-electric.com/safety-and-security-notifications/36-security-notifications/9071-security-notification-citect-anywhere"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2017-7970",
"cwe": {
"id": "CWE-200",
"name": "Exposure of Sensitive Information to an Unauthorized Actor"
},
"notes": [
{
"category": "summary",
"text": "An attacker on an adjacent network may be able to specify arbitrary server target nodes in connection requests to the secure gateway and server components.CVE-2017-7970 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-7970"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric strongly recommends that users upgrade their systems as soon as possible. The following provides links to instructions for addressing software that is at potential risk for the vulnerabilities:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "PowerSCADA Anywhere Version 1 used with PowerSCADA Expert v8.2 and PowerSCADA Expert v8.1: Uninstall PowerSCADA Anywhere (from Add/Remove Programs). Then install PowerSCADA Anywhere Version 1.1 available in the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://schneider-electric.box.com/shared/static/3tvcc115kax8volhd8i13e4wg5k1sdel.iso"
},
{
"category": "mitigation",
"details": "Citect Anywhere version 1.1:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.citect.schneider-electric.com/scada/citectscada/downloads-updates/product-downloads?tab=extra_products"
},
{
"category": "mitigation",
"details": "In addition to installing the provided security patch, Schneider Electric recommends that the following steps be taken to further harden the system:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Configure the HTTP origin header whitelist to match the environment\u0027s URL(s) used for accessing the secure gateway. This address may be one or more of the IP, machine name, or domain name where the secure gateway is hosted. The address may also be that of a load balancer or proxy, if the secure gateway is deployed that way.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Configure the secure gateway\u0027s whitelists to restrict access to expected client IPs, as well as to restrict access from the secure gateway to only expected internal server hosts. For an additional defense-in-depth layer, users can further use the Windows OS-level firewall (or zone firewalls) to restrict communication among only the expected nodes.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "If using self-signed certificates, configure the secure gateway machine to trust the server certificate.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Depending on the organization\u0027s requirements, users can further configure the secure gateway to restrict the usable TLS protocols. For an additional defense-in-depth layer, TLS protocols and cipher suites can also be restricted at the operating system level through the use of third party tools such as IISCrypto.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Create unique user accounts with minimal privileges dedicated to accessing applications remotely. OS group policy objects can be used to further restrict what those unique user accounts are allowed to do. For an example configuration that disables task manager from being launched in a remote app connection, follow the steps available here:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://social.technet.microsoft.com/Forums/office/en-US/35dd3cd6-cc67-476f-82e2-058293e6f657/how-do-i-disable-task-manager-for-users-only?forum=winserverTS"
},
{
"category": "mitigation",
"details": "For more information about the vulnerabilities and patch in PowerSCADA Anywhere, please refer to Schneider Electric Security Notification - PowerSCADA Anywhere SEVD-2017-173-01, which is available at the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"
},
{
"category": "mitigation",
"details": "For more information about the vulnerabilities and patch in Citect Anywhere, please refer to Schneider Electric Security Notification - Citect Anywhere, which is available at the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.citect.schneider-electric.com/safety-and-security-notifications/36-security-notifications/9071-security-notification-citect-anywhere"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2017-7971",
"cwe": {
"id": "CWE-298",
"name": "Improper Validation of Certificate Expiration"
},
"notes": [
{
"category": "summary",
"text": "The affected products use outdated cipher suites and improperly verify peer SSL certificates.CVE-2017-7971 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-7971"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric strongly recommends that users upgrade their systems as soon as possible. The following provides links to instructions for addressing software that is at potential risk for the vulnerabilities:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "PowerSCADA Anywhere Version 1 used with PowerSCADA Expert v8.2 and PowerSCADA Expert v8.1: Uninstall PowerSCADA Anywhere (from Add/Remove Programs). Then install PowerSCADA Anywhere Version 1.1 available in the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://schneider-electric.box.com/shared/static/3tvcc115kax8volhd8i13e4wg5k1sdel.iso"
},
{
"category": "mitigation",
"details": "Citect Anywhere version 1.1:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.citect.schneider-electric.com/scada/citectscada/downloads-updates/product-downloads?tab=extra_products"
},
{
"category": "mitigation",
"details": "In addition to installing the provided security patch, Schneider Electric recommends that the following steps be taken to further harden the system:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Configure the HTTP origin header whitelist to match the environment\u0027s URL(s) used for accessing the secure gateway. This address may be one or more of the IP, machine name, or domain name where the secure gateway is hosted. The address may also be that of a load balancer or proxy, if the secure gateway is deployed that way.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Configure the secure gateway\u0027s whitelists to restrict access to expected client IPs, as well as to restrict access from the secure gateway to only expected internal server hosts. For an additional defense-in-depth layer, users can further use the Windows OS-level firewall (or zone firewalls) to restrict communication among only the expected nodes.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "If using self-signed certificates, configure the secure gateway machine to trust the server certificate.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Depending on the organization\u0027s requirements, users can further configure the secure gateway to restrict the usable TLS protocols. For an additional defense-in-depth layer, TLS protocols and cipher suites can also be restricted at the operating system level through the use of third party tools such as IISCrypto.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Create unique user accounts with minimal privileges dedicated to accessing applications remotely. OS group policy objects can be used to further restrict what those unique user accounts are allowed to do. For an example configuration that disables task manager from being launched in a remote app connection, follow the steps available here:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://social.technet.microsoft.com/Forums/office/en-US/35dd3cd6-cc67-476f-82e2-058293e6f657/how-do-i-disable-task-manager-for-users-only?forum=winserverTS"
},
{
"category": "mitigation",
"details": "For more information about the vulnerabilities and patch in PowerSCADA Anywhere, please refer to Schneider Electric Security Notification - PowerSCADA Anywhere SEVD-2017-173-01, which is available at the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"
},
{
"category": "mitigation",
"details": "For more information about the vulnerabilities and patch in Citect Anywhere, please refer to Schneider Electric Security Notification - Citect Anywhere, which is available at the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.citect.schneider-electric.com/safety-and-security-notifications/36-security-notifications/9071-security-notification-citect-anywhere"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2017-7972",
"cwe": {
"id": "CWE-146",
"name": "Improper Neutralization of Expression/Command Delimiters"
},
"notes": [
{
"category": "summary",
"text": "An attacker on an adjacent network may be able to escape out of remote applications and launch other processes.CVE-2017-7972 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-7972"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric strongly recommends that users upgrade their systems as soon as possible. The following provides links to instructions for addressing software that is at potential risk for the vulnerabilities:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "PowerSCADA Anywhere Version 1 used with PowerSCADA Expert v8.2 and PowerSCADA Expert v8.1: Uninstall PowerSCADA Anywhere (from Add/Remove Programs). Then install PowerSCADA Anywhere Version 1.1 available in the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://schneider-electric.box.com/shared/static/3tvcc115kax8volhd8i13e4wg5k1sdel.iso"
},
{
"category": "mitigation",
"details": "Citect Anywhere version 1.1:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.citect.schneider-electric.com/scada/citectscada/downloads-updates/product-downloads?tab=extra_products"
},
{
"category": "mitigation",
"details": "In addition to installing the provided security patch, Schneider Electric recommends that the following steps be taken to further harden the system:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Configure the HTTP origin header whitelist to match the environment\u0027s URL(s) used for accessing the secure gateway. This address may be one or more of the IP, machine name, or domain name where the secure gateway is hosted. The address may also be that of a load balancer or proxy, if the secure gateway is deployed that way.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Configure the secure gateway\u0027s whitelists to restrict access to expected client IPs, as well as to restrict access from the secure gateway to only expected internal server hosts. For an additional defense-in-depth layer, users can further use the Windows OS-level firewall (or zone firewalls) to restrict communication among only the expected nodes.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "If using self-signed certificates, configure the secure gateway machine to trust the server certificate.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Depending on the organization\u0027s requirements, users can further configure the secure gateway to restrict the usable TLS protocols. For an additional defense-in-depth layer, TLS protocols and cipher suites can also be restricted at the operating system level through the use of third party tools such as IISCrypto.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Create unique user accounts with minimal privileges dedicated to accessing applications remotely. OS group policy objects can be used to further restrict what those unique user accounts are allowed to do. For an example configuration that disables task manager from being launched in a remote app connection, follow the steps available here:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://social.technet.microsoft.com/Forums/office/en-US/35dd3cd6-cc67-476f-82e2-058293e6f657/how-do-i-disable-task-manager-for-users-only?forum=winserverTS"
},
{
"category": "mitigation",
"details": "For more information about the vulnerabilities and patch in PowerSCADA Anywhere, please refer to Schneider Electric Security Notification - PowerSCADA Anywhere SEVD-2017-173-01, which is available at the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"
},
{
"category": "mitigation",
"details": "For more information about the vulnerabilities and patch in Citect Anywhere, please refer to Schneider Electric Security Notification - Citect Anywhere, which is available at the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.citect.schneider-electric.com/safety-and-security-notifications/36-security-notifications/9071-security-notification-citect-anywhere"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
}
]
}
icsa-17-201-01
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Schneider Electric",
"summary": "notifying ICS-CERT of these vulnerabilities after they made the fixes available"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "ATTENTION: Remotely exploitable/low skill level to exploit.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Commercial Facilities",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Paris, France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "NCCIC/ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available in the ICS -CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target these vulnerabilities.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-17-201-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2017/icsa-17-201-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-17-201-01 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-201-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-201-01"
}
],
"title": "Schneider Electric PowerSCADA Anywhere and Citect Anywhere",
"tracking": {
"current_release_date": "2017-07-20T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-17-201-01",
"initial_release_date": "2017-07-20T00:00:00.000000Z",
"revision_history": [
{
"date": "2017-07-20T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version",
"name": "1.0",
"product": {
"name": "Citect Anywhere: version 1.0",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Citect Anywhere"
},
{
"branches": [
{
"category": "product_version",
"name": "1.0",
"product": {
"name": "PowerSCADA Anywhere redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2: Version 1.0",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "PowerSCADA Anywhere redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2"
}
],
"category": "vendor",
"name": "Schneider Electric Software, LLC"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2017-7969",
"cwe": {
"id": "CWE-352",
"name": "Cross-Site Request Forgery (CSRF)"
},
"notes": [
{
"category": "summary",
"text": "The secure gateway component of the affected products is vulnerable to CSRF for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack.CVE-2017-7969 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-7969"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric strongly recommends that users upgrade their systems as soon as possible. The following provides links to instructions for addressing software that is at potential risk for the vulnerabilities:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "PowerSCADA Anywhere Version 1 used with PowerSCADA Expert v8.2 and PowerSCADA Expert v8.1: Uninstall PowerSCADA Anywhere (from Add/Remove Programs). Then install PowerSCADA Anywhere Version 1.1 available in the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://schneider-electric.box.com/shared/static/3tvcc115kax8volhd8i13e4wg5k1sdel.iso"
},
{
"category": "mitigation",
"details": "Citect Anywhere version 1.1:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.citect.schneider-electric.com/scada/citectscada/downloads-updates/product-downloads?tab=extra_products"
},
{
"category": "mitigation",
"details": "In addition to installing the provided security patch, Schneider Electric recommends that the following steps be taken to further harden the system:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Configure the HTTP origin header whitelist to match the environment\u0027s URL(s) used for accessing the secure gateway. This address may be one or more of the IP, machine name, or domain name where the secure gateway is hosted. The address may also be that of a load balancer or proxy, if the secure gateway is deployed that way.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Configure the secure gateway\u0027s whitelists to restrict access to expected client IPs, as well as to restrict access from the secure gateway to only expected internal server hosts. For an additional defense-in-depth layer, users can further use the Windows OS-level firewall (or zone firewalls) to restrict communication among only the expected nodes.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "If using self-signed certificates, configure the secure gateway machine to trust the server certificate.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Depending on the organization\u0027s requirements, users can further configure the secure gateway to restrict the usable TLS protocols. For an additional defense-in-depth layer, TLS protocols and cipher suites can also be restricted at the operating system level through the use of third party tools such as IISCrypto.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Create unique user accounts with minimal privileges dedicated to accessing applications remotely. OS group policy objects can be used to further restrict what those unique user accounts are allowed to do. For an example configuration that disables task manager from being launched in a remote app connection, follow the steps available here:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://social.technet.microsoft.com/Forums/office/en-US/35dd3cd6-cc67-476f-82e2-058293e6f657/how-do-i-disable-task-manager-for-users-only?forum=winserverTS"
},
{
"category": "mitigation",
"details": "For more information about the vulnerabilities and patch in PowerSCADA Anywhere, please refer to Schneider Electric Security Notification - PowerSCADA Anywhere SEVD-2017-173-01, which is available at the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"
},
{
"category": "mitigation",
"details": "For more information about the vulnerabilities and patch in Citect Anywhere, please refer to Schneider Electric Security Notification - Citect Anywhere, which is available at the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.citect.schneider-electric.com/safety-and-security-notifications/36-security-notifications/9071-security-notification-citect-anywhere"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2017-7970",
"cwe": {
"id": "CWE-200",
"name": "Exposure of Sensitive Information to an Unauthorized Actor"
},
"notes": [
{
"category": "summary",
"text": "An attacker on an adjacent network may be able to specify arbitrary server target nodes in connection requests to the secure gateway and server components.CVE-2017-7970 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-7970"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric strongly recommends that users upgrade their systems as soon as possible. The following provides links to instructions for addressing software that is at potential risk for the vulnerabilities:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "PowerSCADA Anywhere Version 1 used with PowerSCADA Expert v8.2 and PowerSCADA Expert v8.1: Uninstall PowerSCADA Anywhere (from Add/Remove Programs). Then install PowerSCADA Anywhere Version 1.1 available in the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://schneider-electric.box.com/shared/static/3tvcc115kax8volhd8i13e4wg5k1sdel.iso"
},
{
"category": "mitigation",
"details": "Citect Anywhere version 1.1:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.citect.schneider-electric.com/scada/citectscada/downloads-updates/product-downloads?tab=extra_products"
},
{
"category": "mitigation",
"details": "In addition to installing the provided security patch, Schneider Electric recommends that the following steps be taken to further harden the system:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Configure the HTTP origin header whitelist to match the environment\u0027s URL(s) used for accessing the secure gateway. This address may be one or more of the IP, machine name, or domain name where the secure gateway is hosted. The address may also be that of a load balancer or proxy, if the secure gateway is deployed that way.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Configure the secure gateway\u0027s whitelists to restrict access to expected client IPs, as well as to restrict access from the secure gateway to only expected internal server hosts. For an additional defense-in-depth layer, users can further use the Windows OS-level firewall (or zone firewalls) to restrict communication among only the expected nodes.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "If using self-signed certificates, configure the secure gateway machine to trust the server certificate.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Depending on the organization\u0027s requirements, users can further configure the secure gateway to restrict the usable TLS protocols. For an additional defense-in-depth layer, TLS protocols and cipher suites can also be restricted at the operating system level through the use of third party tools such as IISCrypto.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Create unique user accounts with minimal privileges dedicated to accessing applications remotely. OS group policy objects can be used to further restrict what those unique user accounts are allowed to do. For an example configuration that disables task manager from being launched in a remote app connection, follow the steps available here:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://social.technet.microsoft.com/Forums/office/en-US/35dd3cd6-cc67-476f-82e2-058293e6f657/how-do-i-disable-task-manager-for-users-only?forum=winserverTS"
},
{
"category": "mitigation",
"details": "For more information about the vulnerabilities and patch in PowerSCADA Anywhere, please refer to Schneider Electric Security Notification - PowerSCADA Anywhere SEVD-2017-173-01, which is available at the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"
},
{
"category": "mitigation",
"details": "For more information about the vulnerabilities and patch in Citect Anywhere, please refer to Schneider Electric Security Notification - Citect Anywhere, which is available at the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.citect.schneider-electric.com/safety-and-security-notifications/36-security-notifications/9071-security-notification-citect-anywhere"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2017-7971",
"cwe": {
"id": "CWE-298",
"name": "Improper Validation of Certificate Expiration"
},
"notes": [
{
"category": "summary",
"text": "The affected products use outdated cipher suites and improperly verify peer SSL certificates.CVE-2017-7971 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-7971"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric strongly recommends that users upgrade their systems as soon as possible. The following provides links to instructions for addressing software that is at potential risk for the vulnerabilities:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "PowerSCADA Anywhere Version 1 used with PowerSCADA Expert v8.2 and PowerSCADA Expert v8.1: Uninstall PowerSCADA Anywhere (from Add/Remove Programs). Then install PowerSCADA Anywhere Version 1.1 available in the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://schneider-electric.box.com/shared/static/3tvcc115kax8volhd8i13e4wg5k1sdel.iso"
},
{
"category": "mitigation",
"details": "Citect Anywhere version 1.1:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.citect.schneider-electric.com/scada/citectscada/downloads-updates/product-downloads?tab=extra_products"
},
{
"category": "mitigation",
"details": "In addition to installing the provided security patch, Schneider Electric recommends that the following steps be taken to further harden the system:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Configure the HTTP origin header whitelist to match the environment\u0027s URL(s) used for accessing the secure gateway. This address may be one or more of the IP, machine name, or domain name where the secure gateway is hosted. The address may also be that of a load balancer or proxy, if the secure gateway is deployed that way.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Configure the secure gateway\u0027s whitelists to restrict access to expected client IPs, as well as to restrict access from the secure gateway to only expected internal server hosts. For an additional defense-in-depth layer, users can further use the Windows OS-level firewall (or zone firewalls) to restrict communication among only the expected nodes.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "If using self-signed certificates, configure the secure gateway machine to trust the server certificate.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Depending on the organization\u0027s requirements, users can further configure the secure gateway to restrict the usable TLS protocols. For an additional defense-in-depth layer, TLS protocols and cipher suites can also be restricted at the operating system level through the use of third party tools such as IISCrypto.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Create unique user accounts with minimal privileges dedicated to accessing applications remotely. OS group policy objects can be used to further restrict what those unique user accounts are allowed to do. For an example configuration that disables task manager from being launched in a remote app connection, follow the steps available here:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://social.technet.microsoft.com/Forums/office/en-US/35dd3cd6-cc67-476f-82e2-058293e6f657/how-do-i-disable-task-manager-for-users-only?forum=winserverTS"
},
{
"category": "mitigation",
"details": "For more information about the vulnerabilities and patch in PowerSCADA Anywhere, please refer to Schneider Electric Security Notification - PowerSCADA Anywhere SEVD-2017-173-01, which is available at the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"
},
{
"category": "mitigation",
"details": "For more information about the vulnerabilities and patch in Citect Anywhere, please refer to Schneider Electric Security Notification - Citect Anywhere, which is available at the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.citect.schneider-electric.com/safety-and-security-notifications/36-security-notifications/9071-security-notification-citect-anywhere"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2017-7972",
"cwe": {
"id": "CWE-146",
"name": "Improper Neutralization of Expression/Command Delimiters"
},
"notes": [
{
"category": "summary",
"text": "An attacker on an adjacent network may be able to escape out of remote applications and launch other processes.CVE-2017-7972 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-7972"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric strongly recommends that users upgrade their systems as soon as possible. The following provides links to instructions for addressing software that is at potential risk for the vulnerabilities:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "PowerSCADA Anywhere Version 1 used with PowerSCADA Expert v8.2 and PowerSCADA Expert v8.1: Uninstall PowerSCADA Anywhere (from Add/Remove Programs). Then install PowerSCADA Anywhere Version 1.1 available in the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://schneider-electric.box.com/shared/static/3tvcc115kax8volhd8i13e4wg5k1sdel.iso"
},
{
"category": "mitigation",
"details": "Citect Anywhere version 1.1:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.citect.schneider-electric.com/scada/citectscada/downloads-updates/product-downloads?tab=extra_products"
},
{
"category": "mitigation",
"details": "In addition to installing the provided security patch, Schneider Electric recommends that the following steps be taken to further harden the system:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Configure the HTTP origin header whitelist to match the environment\u0027s URL(s) used for accessing the secure gateway. This address may be one or more of the IP, machine name, or domain name where the secure gateway is hosted. The address may also be that of a load balancer or proxy, if the secure gateway is deployed that way.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Configure the secure gateway\u0027s whitelists to restrict access to expected client IPs, as well as to restrict access from the secure gateway to only expected internal server hosts. For an additional defense-in-depth layer, users can further use the Windows OS-level firewall (or zone firewalls) to restrict communication among only the expected nodes.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "If using self-signed certificates, configure the secure gateway machine to trust the server certificate.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Depending on the organization\u0027s requirements, users can further configure the secure gateway to restrict the usable TLS protocols. For an additional defense-in-depth layer, TLS protocols and cipher suites can also be restricted at the operating system level through the use of third party tools such as IISCrypto.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Create unique user accounts with minimal privileges dedicated to accessing applications remotely. OS group policy objects can be used to further restrict what those unique user accounts are allowed to do. For an example configuration that disables task manager from being launched in a remote app connection, follow the steps available here:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://social.technet.microsoft.com/Forums/office/en-US/35dd3cd6-cc67-476f-82e2-058293e6f657/how-do-i-disable-task-manager-for-users-only?forum=winserverTS"
},
{
"category": "mitigation",
"details": "For more information about the vulnerabilities and patch in PowerSCADA Anywhere, please refer to Schneider Electric Security Notification - PowerSCADA Anywhere SEVD-2017-173-01, which is available at the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"
},
{
"category": "mitigation",
"details": "For more information about the vulnerabilities and patch in Citect Anywhere, please refer to Schneider Electric Security Notification - Citect Anywhere, which is available at the following location:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.citect.schneider-electric.com/safety-and-security-notifications/36-security-notifications/9071-security-notification-citect-anywhere"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
}
]
}
fkie_cve-2017-7969
Vulnerability from fkie_nvd
| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/ | Mitigation, Patch, Vendor Advisory | |
| cybersecurity@se.com | http://www.securityfocus.com/bid/99913 | Third Party Advisory, VDB Entry | |
| cybersecurity@se.com | https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere | Issue Tracking, Mitigation, Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/ | Mitigation, Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/99913 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere | Issue Tracking, Mitigation, Patch, Vendor Advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | powerscada_anywhere | 1.0 | |
| schneider-electric | powerscada_expert | 8.1 | |
| schneider-electric | powerscada_expert | 8.2 | |
| schneider-electric | citect_anywhere | 1.0 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:powerscada_anywhere:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "6445511E-70B8-4E03-A178-FFDBE02E1609",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:powerscada_expert:8.1:*:*:*:*:*:*:*",
"matchCriteriaId": "AE171A71-B1AF-471B-9D27-07D4491D05B3",
"vulnerable": false
},
{
"criteria": "cpe:2.3:a:schneider-electric:powerscada_expert:8.2:*:*:*:*:*:*:*",
"matchCriteriaId": "D2A3FA74-D201-41AA-BDA1-82816813AD11",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:citect_anywhere:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "5182F21D-1DF5-492A-9A3D-B913AC6B12F6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric\u0027s PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de Cross-Site Request Forgery (CSRF) en el componente Secure Gateway de PowerSCADA Anywhere v1.0 redistribuido con PowerSCADA Expert v8.1 y PowerSCADA Expert v8.2 y Citect Anywhere versi\u00f3n 1.0, de Schneider Electric para m\u00faltiples peticiones de cambio de estado. Este tipo de ataque requiere cierto nivel de ingenier\u00eda social para conseguir que un usuario leg\u00edtimo haga clic o acceda a un enlace o p\u00e1gina maliciosa que contenga el ataque CSRF."
}
],
"id": "CVE-2017-7969",
"lastModified": "2025-04-20T01:37:25.860",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2017-09-26T01:29:03.460",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"
},
{
"source": "cybersecurity@se.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/99913"
},
{
"source": "cybersecurity@se.com",
"tags": [
"Issue Tracking",
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/99913"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Issue Tracking",
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-352"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
ghsa-gm35-5x3x-4xw9
Vulnerability from github
A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack.
{
"affected": [],
"aliases": [
"CVE-2017-7969"
],
"database_specific": {
"cwe_ids": [
"CWE-352"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2017-09-26T01:29:00Z",
"severity": "HIGH"
},
"details": "A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric\u0027s PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack.",
"id": "GHSA-gm35-5x3x-4xw9",
"modified": "2025-04-20T03:45:53Z",
"published": "2022-05-17T00:36:07Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2017-7969"
},
{
"type": "WEB",
"url": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere"
},
{
"type": "WEB",
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01"
},
{
"type": "WEB",
"url": "http://www.securityfocus.com/bid/99913"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
gsd-2017-7969
Vulnerability from gsd
{
"GSD": {
"alias": "CVE-2017-7969",
"description": "A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric\u0027s PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack.",
"id": "GSD-2017-7969"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2017-7969"
],
"details": "A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric\u0027s PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack.",
"id": "GSD-2017-7969",
"modified": "2023-12-13T01:21:06.711264Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2017-06-22T00:00:00",
"ID": "CVE-2017-7969",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PowerSCADA Anywhere",
"version": {
"version_data": [
{
"version_value": "Version 1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2"
}
]
}
},
{
"product_name": "Citect Anywhere",
"version": {
"version_data": [
{
"version_value": "version 1.0"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric\u0027s PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Cross Site Request Forgery"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "99913",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/99913"
},
{
"name": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere",
"refsource": "CONFIRM",
"url": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere"
},
{
"name": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/",
"refsource": "CONFIRM",
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:powerscada_anywhere:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:powerscada_expert:8.2:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:powerscada_expert:8.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:citect_anywhere:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2017-7969"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric\u0027s PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-352"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere",
"refsource": "CONFIRM",
"tags": [
"Issue Tracking",
"Mitigation",
"Vendor Advisory",
"Patch"
],
"url": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere"
},
{
"name": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/",
"refsource": "CONFIRM",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"
},
{
"name": "99913",
"refsource": "BID",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/99913"
}
]
}
},
"impact": {
"baseMetricV2": {
"cvssV2": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": true
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
},
"lastModifiedDate": "2017-09-29T17:09Z",
"publishedDate": "2017-09-26T01:29Z"
}
}
}
var-201709-1097
Vulnerability from variot
A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack. Schneider Electric's PowerSCADA Anywhere and Citect Anywhere Contains a cross-site request forgery vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. PowerSCADA Anywhere is SCADA and power monitoring software. Citect is an industrial automation operation and monitoring software. Schneider Electric PowerSCADA Anywhere and Citect Anywhere are prone to the following security vulnerabilities: 1. A cross-site request-forgery vulnerability 2. An information-disclosure vulnerability 3. Multiple security-bypass vulnerabilities Exploiting these issues could allow an attacker to obtain sensitive information, bypass certain security restrictions, perform unauthorized actions, or gain access to the affected system. Following products and versions are vulnerable: PowerSCADA Anywhere 1.0 redistributed with PowerSCADA Expert 8.1 and PowerSCADA Expert 8.2 Citect Anywhere 1.0
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201709-1097",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "powerscada anywhere",
"scope": "eq",
"trust": 2.7,
"vendor": "schneider electric",
"version": "1.0"
},
{
"model": "citect anywhere",
"scope": "eq",
"trust": 2.7,
"vendor": "schneider electric",
"version": "1.0"
},
{
"model": "electric citect anywhere",
"scope": "eq",
"trust": 0.6,
"vendor": "schneider",
"version": "1.0"
},
{
"model": "electric powerscada anywhere",
"scope": "eq",
"trust": 0.6,
"vendor": "schneider",
"version": "1.0"
},
{
"model": "powerscada expert",
"scope": "eq",
"trust": 0.3,
"vendor": "schneider electric",
"version": "8.2"
},
{
"model": "powerscada expert",
"scope": "eq",
"trust": 0.3,
"vendor": "schneider electric",
"version": "8.1"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "powerscada anywhere",
"version": "1.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "citect anywhere",
"version": "1.0"
}
],
"sources": [
{
"db": "IVD",
"id": "7455cbdf-acd0-4108-bba4-fb9f68930c62"
},
{
"db": "CNVD",
"id": "CNVD-2017-22845"
},
{
"db": "BID",
"id": "99913"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-008372"
},
{
"db": "CNNVD",
"id": "CNNVD-201704-899"
},
{
"db": "NVD",
"id": "CVE-2017-7969"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:schneider_electric:citect_anywhere",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:schneider_electric:powerscada_anywhere",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-008372"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Schneider Electric",
"sources": [
{
"db": "BID",
"id": "99913"
}
],
"trust": 0.3
},
"cve": "CVE-2017-7969",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "CVE-2017-7969",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 8.8,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.6,
"id": "CNVD-2017-22845",
"impactScore": 9.2,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:N",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "NONE",
"baseScore": 8.8,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.6,
"id": "7455cbdf-acd0-4108-bba4-fb9f68930c62",
"impactScore": 9.2,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:N",
"version": "2.9 [IVD]"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2017-7969",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2017-7969",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2017-7969",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2017-22845",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201704-899",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "7455cbdf-acd0-4108-bba4-fb9f68930c62",
"trust": 0.2,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "7455cbdf-acd0-4108-bba4-fb9f68930c62"
},
{
"db": "CNVD",
"id": "CNVD-2017-22845"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-008372"
},
{
"db": "CNNVD",
"id": "CNNVD-201704-899"
},
{
"db": "NVD",
"id": "CVE-2017-7969"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric\u0027s PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack. Schneider Electric\u0027s PowerSCADA Anywhere and Citect Anywhere Contains a cross-site request forgery vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. PowerSCADA Anywhere is SCADA and power monitoring software. Citect is an industrial automation operation and monitoring software. Schneider Electric PowerSCADA Anywhere and Citect Anywhere are prone to the following security vulnerabilities:\n1. A cross-site request-forgery vulnerability\n2. An information-disclosure vulnerability\n3. Multiple security-bypass vulnerabilities\nExploiting these issues could allow an attacker to obtain sensitive information, bypass certain security restrictions, perform unauthorized actions, or gain access to the affected system. \nFollowing products and versions are vulnerable:\nPowerSCADA Anywhere 1.0 redistributed with PowerSCADA Expert 8.1 and PowerSCADA Expert 8.2\nCitect Anywhere 1.0",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-7969"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-008372"
},
{
"db": "CNVD",
"id": "CNVD-2017-22845"
},
{
"db": "BID",
"id": "99913"
},
{
"db": "IVD",
"id": "7455cbdf-acd0-4108-bba4-fb9f68930c62"
}
],
"trust": 2.61
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-7969",
"trust": 3.5
},
{
"db": "SCHNEIDER",
"id": "SEVD-2017-173-01",
"trust": 1.9
},
{
"db": "BID",
"id": "99913",
"trust": 1.9
},
{
"db": "ICS CERT",
"id": "ICSA-17-201-01",
"trust": 1.5
},
{
"db": "CNVD",
"id": "CNVD-2017-22845",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201704-899",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2017-008372",
"trust": 0.8
},
{
"db": "NSFOCUS",
"id": "37196",
"trust": 0.6
},
{
"db": "IVD",
"id": "7455CBDF-ACD0-4108-BBA4-FB9F68930C62",
"trust": 0.2
}
],
"sources": [
{
"db": "IVD",
"id": "7455cbdf-acd0-4108-bba4-fb9f68930c62"
},
{
"db": "CNVD",
"id": "CNVD-2017-22845"
},
{
"db": "BID",
"id": "99913"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-008372"
},
{
"db": "CNNVD",
"id": "CNNVD-201704-899"
},
{
"db": "NVD",
"id": "CVE-2017-7969"
}
]
},
"id": "VAR-201709-1097",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "7455cbdf-acd0-4108-bba4-fb9f68930c62"
},
{
"db": "CNVD",
"id": "CNVD-2017-22845"
}
],
"trust": 1.614484135
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "7455cbdf-acd0-4108-bba4-fb9f68930c62"
},
{
"db": "CNVD",
"id": "CNVD-2017-22845"
}
]
},
"last_update_date": "2024-11-23T22:12:40.150000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SEVD-2017-173-01",
"trust": 0.8,
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"
},
{
"title": "Security Notification - Citect Anywhere",
"trust": 0.8,
"url": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere"
},
{
"title": "Patch for Schneider Electric PowerSCADA Anywhere/Citect Anywhere Cross-Site Request Forgery Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/100823"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-22845"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-008372"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-352",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-008372"
},
{
"db": "NVD",
"id": "CVE-2017-7969"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.9,
"url": "http://www.schneider-electric.com/en/download/document/sevd-2017-173-01/"
},
{
"trust": 1.6,
"url": "http://www.securityfocus.com/bid/99913"
},
{
"trust": 1.6,
"url": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere"
},
{
"trust": 1.5,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-17-201-01"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-7969"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-7969"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/37196"
},
{
"trust": 0.3,
"url": "http://www.schneider-electric.com/site/home/index.cfm/ww/?selectcountry=true"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-22845"
},
{
"db": "BID",
"id": "99913"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-008372"
},
{
"db": "CNNVD",
"id": "CNNVD-201704-899"
},
{
"db": "NVD",
"id": "CVE-2017-7969"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "7455cbdf-acd0-4108-bba4-fb9f68930c62"
},
{
"db": "CNVD",
"id": "CNVD-2017-22845"
},
{
"db": "BID",
"id": "99913"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-008372"
},
{
"db": "CNNVD",
"id": "CNNVD-201704-899"
},
{
"db": "NVD",
"id": "CVE-2017-7969"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-08-25T00:00:00",
"db": "IVD",
"id": "7455cbdf-acd0-4108-bba4-fb9f68930c62"
},
{
"date": "2017-08-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-22845"
},
{
"date": "2017-07-20T00:00:00",
"db": "BID",
"id": "99913"
},
{
"date": "2017-10-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-008372"
},
{
"date": "2017-04-20T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201704-899"
},
{
"date": "2017-09-26T01:29:03.460000",
"db": "NVD",
"id": "CVE-2017-7969"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-09-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-22845"
},
{
"date": "2017-07-20T00:00:00",
"db": "BID",
"id": "99913"
},
{
"date": "2017-10-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-008372"
},
{
"date": "2017-09-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201704-899"
},
{
"date": "2024-11-21T03:33:04.120000",
"db": "NVD",
"id": "CVE-2017-7969"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201704-899"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Schneider Electric PowerSCADA Anywhere/Citect Anywhere Cross-Site Request Forgery Vulnerability",
"sources": [
{
"db": "IVD",
"id": "7455cbdf-acd0-4108-bba4-fb9f68930c62"
},
{
"db": "CNVD",
"id": "CNVD-2017-22845"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "cross-site request forgery",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201704-899"
}
],
"trust": 0.6
}
}
cnvd-2017-22845
Vulnerability from cnvd
目前厂商已经发布了升级补丁以修复这个安全问题,请到厂商的主页下载:https://www.citect.schneider-electric.com/safety-and-security-notifications/36-security-notifications/9071-security-notification-citect-anywhere
| Name | ['Schneider Electric Citect Anywhere 1.0', 'Schneider Electric PowerSCADA Anywhere 1.0'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2017-7969",
"cveUrl": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2017-7969"
}
},
"description": "PowerSCADA Anywhere\u662fSCADA\u548c\u7535\u529b\u76d1\u6d4b\u8f6f\u4ef6\u3002Citect\u662f\u5de5\u4e1a\u81ea\u52a8\u5316\u64cd\u4f5c\u53ca\u76d1\u63a7\u8f6f\u4ef6\u3002\r\n\r\nSchneider Electric PowerSCADA Anywhere 1.0\u53caCitect Anywhere 1.0\u7248\u672c\u7f51\u5173\u7ec4\u4ef6\u5b58\u5728\u8de8\u7ad9\u8bf7\u6c42\u4f2a\u9020\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u6267\u884cCSRF\u653b\u51fb\u3002",
"formalWay": "\u76ee\u524d\u5382\u5546\u5df2\u7ecf\u53d1\u5e03\u4e86\u5347\u7ea7\u8865\u4e01\u4ee5\u4fee\u590d\u8fd9\u4e2a\u5b89\u5168\u95ee\u9898\uff0c\u8bf7\u5230\u5382\u5546\u7684\u4e3b\u9875\u4e0b\u8f7d\uff1ahttps://www.citect.schneider-electric.com/safety-and-security-notifications/36-security-notifications/9071-security-notification-citect-anywhere",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2017-22845",
"openTime": "2017-08-25",
"patchDescription": "PowerSCADA Anywhere\u662fSCADA\u548c\u7535\u529b\u76d1\u6d4b\u8f6f\u4ef6\u3002Citect\u662f\u5de5\u4e1a\u81ea\u52a8\u5316\u64cd\u4f5c\u53ca\u76d1\u63a7\u8f6f\u4ef6\u3002\r\n\r\nSchneider Electric PowerSCADA Anywhere 1.0\u53caCitect Anywhere 1.0\u7248\u672c\u7f51\u5173\u7ec4\u4ef6\u5b58\u5728\u8de8\u7ad9\u8bf7\u6c42\u4f2a\u9020\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u6267\u884cCSRF\u653b\u51fb\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Schneider Electric PowerSCADA Anywhere/Citect Anywhere\u8de8\u7ad9\u8bf7\u6c42\u4f2a\u9020\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": [
"Schneider Electric Citect Anywhere 1.0",
"Schneider Electric PowerSCADA Anywhere 1.0"
]
},
"referenceLink": "https://nvd.nist.gov/vuln/detail/CVE-2017-7969\r\nhttps://ics-cert.us-cert.gov/advisories/ICSA-17-201-01",
"serverity": "\u9ad8",
"submitTime": "2017-07-24",
"title": "Schneider Electric PowerSCADA Anywhere/Citect Anywhere\u8de8\u7ad9\u8bf7\u6c42\u4f2a\u9020\u6f0f\u6d1e"
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.