Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2017-5706 (GCVE-0-2017-5706)
Vulnerability from cvelistv5
- Elevation of Privilege
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Intel Corporation | Server Platform Services |
Version: 4.0 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T15:11:48.513Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "101906",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/101906"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20171120-0001/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03798en_us"
},
{
"name": "1039955",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1039955"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://twitter.com/PTsecurity_UK/status/938447926128291842"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpuoct2017-3236626.html"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00086\u0026languageid=en-fr"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892715.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.asus.com/News/wzeltG5CjYaIwGJ0"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Server Platform Services",
"vendor": "Intel Corporation",
"versions": [
{
"status": "affected",
"version": "4.0"
}
]
}
],
"datePublic": "2017-11-20T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Multiple buffer overflows in kernel in Intel Server Platform Services Firmware 4.0 allow attacker with local access to the system to execute arbitrary code."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Elevation of Privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-05-10T09:57:01",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "101906",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/101906"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20171120-0001/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03798en_us"
},
{
"name": "1039955",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1039955"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://twitter.com/PTsecurity_UK/status/938447926128291842"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpuoct2017-3236626.html"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00086\u0026languageid=en-fr"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892715.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.asus.com/News/wzeltG5CjYaIwGJ0"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"DATE_PUBLIC": "2017-11-20T00:00:00",
"ID": "CVE-2017-5706",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Server Platform Services",
"version": {
"version_data": [
{
"version_value": "4.0"
}
]
}
}
]
},
"vendor_name": "Intel Corporation"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple buffer overflows in kernel in Intel Server Platform Services Firmware 4.0 allow attacker with local access to the system to execute arbitrary code."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Elevation of Privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "101906",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/101906"
},
{
"name": "https://security.netapp.com/advisory/ntap-20171120-0001/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20171120-0001/"
},
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03798en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03798en_us"
},
{
"name": "1039955",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1039955"
},
{
"name": "https://twitter.com/PTsecurity_UK/status/938447926128291842",
"refsource": "MISC",
"url": "https://twitter.com/PTsecurity_UK/status/938447926128291842"
},
{
"name": "http://www.oracle.com/technetwork/security-advisory/cpuoct2017-3236626.html",
"refsource": "CONFIRM",
"url": "http://www.oracle.com/technetwork/security-advisory/cpuoct2017-3236626.html"
},
{
"name": "https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00086\u0026languageid=en-fr",
"refsource": "CONFIRM",
"url": "https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00086\u0026languageid=en-fr"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-892715.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892715.pdf"
},
{
"name": "https://www.asus.com/News/wzeltG5CjYaIwGJ0",
"refsource": "CONFIRM",
"url": "https://www.asus.com/News/wzeltG5CjYaIwGJ0"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2017-5706",
"datePublished": "2017-11-21T14:00:00Z",
"dateReserved": "2017-02-01T00:00:00",
"dateUpdated": "2024-09-17T04:13:56.471Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2017-5706\",\"sourceIdentifier\":\"secure@intel.com\",\"published\":\"2017-11-21T14:29:00.323\",\"lastModified\":\"2025-04-20T01:37:25.860\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Multiple buffer overflows in kernel in Intel Server Platform Services Firmware 4.0 allow attacker with local access to the system to execute arbitrary code.\"},{\"lang\":\"es\",\"value\":\"M\u00faltiples desbordamientos de b\u00fafer en el kernel en Intel Server Platform Services Firmware 4.0 permiten que un atacante con acceso local al sistema ejecute c\u00f3digo arbitrario.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":7.2,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:intel:server_platform_services_firmware:4.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"97B64BD5-329C-422F-AAB5-B4C0FA3E73D7\"}]}]}],\"references\":[{\"url\":\"http://www.oracle.com/technetwork/security-advisory/cpuoct2017-3236626.html\",\"source\":\"secure@intel.com\",\"tags\":[\"Issue Tracking\",\"Patch\",\"Third Party Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/101906\",\"source\":\"secure@intel.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://www.securitytracker.com/id/1039955\",\"source\":\"secure@intel.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-892715.pdf\",\"source\":\"secure@intel.com\"},{\"url\":\"https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00086\u0026languageid=en-fr\",\"source\":\"secure@intel.com\",\"tags\":[\"Issue Tracking\",\"Vendor Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20171120-0001/\",\"source\":\"secure@intel.com\",\"tags\":[\"Issue Tracking\",\"Third Party Advisory\",\"Tool Signature\"]},{\"url\":\"https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03798en_us\",\"source\":\"secure@intel.com\"},{\"url\":\"https://twitter.com/PTsecurity_UK/status/938447926128291842\",\"source\":\"secure@intel.com\"},{\"url\":\"https://www.asus.com/News/wzeltG5CjYaIwGJ0\",\"source\":\"secure@intel.com\"},{\"url\":\"http://www.oracle.com/technetwork/security-advisory/cpuoct2017-3236626.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Issue Tracking\",\"Patch\",\"Third Party Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/101906\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://www.securitytracker.com/id/1039955\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-892715.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00086\u0026languageid=en-fr\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Issue Tracking\",\"Vendor Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20171120-0001/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Issue Tracking\",\"Third Party Advisory\",\"Tool Signature\"]},{\"url\":\"https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03798en_us\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://twitter.com/PTsecurity_UK/status/938447926128291842\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://www.asus.com/News/wzeltG5CjYaIwGJ0\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}"
}
}
cnvd-2017-37803
Vulnerability from cnvd
厂商已发布漏洞修复程序,请及时关注更新: https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00086&languageid=en-fr
| Name | Intel Server Platform Services Firmware 4.0 |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2017-5706"
}
},
"description": "Intel Server Platform Services Firmware\u662f\u4e00\u6b3e\u4f7f\u7528\u5728CPU\uff08\u4e2d\u592e\u5904\u7406\u5668\uff09\u4e2d\u7684\u670d\u52a1\u5668\u5e73\u53f0\u670d\u52a1\u7a0b\u5e8f\u3002\r\n\r\nIntel Server Platform Services Firmware\u5b58\u5728\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\u3002\u5141\u8bb8\u7cfb\u7edf\u672c\u5730\u8bbf\u95ee\u6743\u7684\u653b\u51fb\u8005\u5229\u7528\u8be5\u6f0f\u6d1e\u6267\u884c\u4efb\u610f\u4ee3\u7801\u3002",
"discovererName": "Intel",
"formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00086\u0026languageid=en-fr",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2017-37803",
"openTime": "2017-12-21",
"patchDescription": "Intel Server Platform Services Firmware\u662f\u4e00\u6b3e\u4f7f\u7528\u5728CPU\uff08\u4e2d\u592e\u5904\u7406\u5668\uff09\u4e2d\u7684\u670d\u52a1\u5668\u5e73\u53f0\u670d\u52a1\u7a0b\u5e8f\u3002\r\n\r\nIntel Server Platform Services Firmware\u5b58\u5728\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\u3002\u5141\u8bb8\u7cfb\u7edf\u672c\u5730\u8bbf\u95ee\u6743\u7684\u653b\u51fb\u8005\u5229\u7528\u8be5\u6f0f\u6d1e\u6267\u884c\u4efb\u610f\u4ee3\u7801\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Intel Server Platform Services Firmware\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": "Intel Server Platform Services Firmware 4.0"
},
"referenceLink": "https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00086\u0026languageid=en-fr",
"serverity": "\u9ad8",
"submitTime": "2017-11-22",
"title": "Intel Server Platform Services Firmware\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e"
}
fkie_cve-2017-5706
Vulnerability from fkie_nvd
| URL | Tags | ||
|---|---|---|---|
| secure@intel.com | http://www.oracle.com/technetwork/security-advisory/cpuoct2017-3236626.html | Issue Tracking, Patch, Third Party Advisory | |
| secure@intel.com | http://www.securityfocus.com/bid/101906 | Third Party Advisory, VDB Entry | |
| secure@intel.com | http://www.securitytracker.com/id/1039955 | Third Party Advisory, VDB Entry | |
| secure@intel.com | https://cert-portal.siemens.com/productcert/pdf/ssa-892715.pdf | ||
| secure@intel.com | https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00086&languageid=en-fr | Issue Tracking, Vendor Advisory | |
| secure@intel.com | https://security.netapp.com/advisory/ntap-20171120-0001/ | Issue Tracking, Third Party Advisory, Tool Signature | |
| secure@intel.com | https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03798en_us | ||
| secure@intel.com | https://twitter.com/PTsecurity_UK/status/938447926128291842 | ||
| secure@intel.com | https://www.asus.com/News/wzeltG5CjYaIwGJ0 | ||
| af854a3a-2127-422b-91ae-364da2661108 | http://www.oracle.com/technetwork/security-advisory/cpuoct2017-3236626.html | Issue Tracking, Patch, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/101906 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securitytracker.com/id/1039955 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-892715.pdf | ||
| af854a3a-2127-422b-91ae-364da2661108 | https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00086&languageid=en-fr | Issue Tracking, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://security.netapp.com/advisory/ntap-20171120-0001/ | Issue Tracking, Third Party Advisory, Tool Signature | |
| af854a3a-2127-422b-91ae-364da2661108 | https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf03798en_us | ||
| af854a3a-2127-422b-91ae-364da2661108 | https://twitter.com/PTsecurity_UK/status/938447926128291842 | ||
| af854a3a-2127-422b-91ae-364da2661108 | https://www.asus.com/News/wzeltG5CjYaIwGJ0 |
| Vendor | Product | Version | |
|---|---|---|---|
| intel | server_platform_services_firmware | 4.0 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:intel:server_platform_services_firmware:4.0:*:*:*:*:*:*:*",
"matchCriteriaId": "97B64BD5-329C-422F-AAB5-B4C0FA3E73D7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Multiple buffer overflows in kernel in Intel Server Platform Services Firmware 4.0 allow attacker with local access to the system to execute arbitrary code."
},
{
"lang": "es",
"value": "M\u00faltiples desbordamientos de b\u00fafer en el kernel en Intel Server Platform Services Firmware 4.0 permiten que un atacante con acceso local al sistema ejecute c\u00f3digo arbitrario."
}
],
"id": "CVE-2017-5706",
"lastModified": "2025-04-20T01:37:25.860",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2017-11-21T14:29:00.323",
"references": [
{
"source": "secure@intel.com",
"tags": [
"Issue Tracking",
"Patch",
"Third Party Advisory"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpuoct2017-3236626.html"
},
{
"source": "secure@intel.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/101906"
},
{
"source": "secure@intel.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1039955"
},
{
"source": "secure@intel.com",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892715.pdf"
},
{
"source": "secure@intel.com",
"tags": [
"Issue Tracking",
"Vendor Advisory"
],
"url": "https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00086\u0026languageid=en-fr"
},
{
"source": "secure@intel.com",
"tags": [
"Issue Tracking",
"Third Party Advisory",
"Tool Signature"
],
"url": "https://security.netapp.com/advisory/ntap-20171120-0001/"
},
{
"source": "secure@intel.com",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03798en_us"
},
{
"source": "secure@intel.com",
"url": "https://twitter.com/PTsecurity_UK/status/938447926128291842"
},
{
"source": "secure@intel.com",
"url": "https://www.asus.com/News/wzeltG5CjYaIwGJ0"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Issue Tracking",
"Patch",
"Third Party Advisory"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpuoct2017-3236626.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/101906"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1039955"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892715.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Issue Tracking",
"Vendor Advisory"
],
"url": "https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00086\u0026languageid=en-fr"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Issue Tracking",
"Third Party Advisory",
"Tool Signature"
],
"url": "https://security.netapp.com/advisory/ntap-20171120-0001/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03798en_us"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://twitter.com/PTsecurity_UK/status/938447926128291842"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.asus.com/News/wzeltG5CjYaIwGJ0"
}
],
"sourceIdentifier": "secure@intel.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
gsd-2017-5706
Vulnerability from gsd
{
"GSD": {
"alias": "CVE-2017-5706",
"description": "Multiple buffer overflows in kernel in Intel Server Platform Services Firmware 4.0 allow attacker with local access to the system to execute arbitrary code.",
"id": "GSD-2017-5706"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2017-5706"
],
"details": "Multiple buffer overflows in kernel in Intel Server Platform Services Firmware 4.0 allow attacker with local access to the system to execute arbitrary code.",
"id": "GSD-2017-5706",
"modified": "2023-12-13T01:21:13.714801Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"DATE_PUBLIC": "2017-11-20T00:00:00",
"ID": "CVE-2017-5706",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Server Platform Services",
"version": {
"version_data": [
{
"version_value": "4.0"
}
]
}
}
]
},
"vendor_name": "Intel Corporation"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple buffer overflows in kernel in Intel Server Platform Services Firmware 4.0 allow attacker with local access to the system to execute arbitrary code."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Elevation of Privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "101906",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/101906"
},
{
"name": "https://security.netapp.com/advisory/ntap-20171120-0001/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20171120-0001/"
},
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03798en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03798en_us"
},
{
"name": "1039955",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1039955"
},
{
"name": "https://twitter.com/PTsecurity_UK/status/938447926128291842",
"refsource": "MISC",
"url": "https://twitter.com/PTsecurity_UK/status/938447926128291842"
},
{
"name": "http://www.oracle.com/technetwork/security-advisory/cpuoct2017-3236626.html",
"refsource": "CONFIRM",
"url": "http://www.oracle.com/technetwork/security-advisory/cpuoct2017-3236626.html"
},
{
"name": "https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00086\u0026languageid=en-fr",
"refsource": "CONFIRM",
"url": "https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00086\u0026languageid=en-fr"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-892715.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892715.pdf"
},
{
"name": "https://www.asus.com/News/wzeltG5CjYaIwGJ0",
"refsource": "CONFIRM",
"url": "https://www.asus.com/News/wzeltG5CjYaIwGJ0"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:intel:server_platform_services_firmware:4.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2017-5706"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "Multiple buffer overflows in kernel in Intel Server Platform Services Firmware 4.0 allow attacker with local access to the system to execute arbitrary code."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00086\u0026languageid=en-fr",
"refsource": "CONFIRM",
"tags": [
"Issue Tracking",
"Vendor Advisory"
],
"url": "https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00086\u0026languageid=en-fr"
},
{
"name": "http://www.oracle.com/technetwork/security-advisory/cpuoct2017-3236626.html",
"refsource": "CONFIRM",
"tags": [
"Issue Tracking",
"Patch",
"Third Party Advisory"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpuoct2017-3236626.html"
},
{
"name": "https://security.netapp.com/advisory/ntap-20171120-0001/",
"refsource": "CONFIRM",
"tags": [
"Issue Tracking",
"Third Party Advisory",
"Tool Signature"
],
"url": "https://security.netapp.com/advisory/ntap-20171120-0001/"
},
{
"name": "101906",
"refsource": "BID",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/101906"
},
{
"name": "1039955",
"refsource": "SECTRACK",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1039955"
},
{
"name": "https://twitter.com/PTsecurity_UK/status/938447926128291842",
"refsource": "MISC",
"tags": [],
"url": "https://twitter.com/PTsecurity_UK/status/938447926128291842"
},
{
"name": "https://www.asus.com/News/wzeltG5CjYaIwGJ0",
"refsource": "CONFIRM",
"tags": [],
"url": "https://www.asus.com/News/wzeltG5CjYaIwGJ0"
},
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03798en_us",
"refsource": "CONFIRM",
"tags": [],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03798en_us"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-892715.pdf",
"refsource": "CONFIRM",
"tags": [],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892715.pdf"
}
]
}
},
"impact": {
"baseMetricV2": {
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
},
"lastModifiedDate": "2018-05-11T01:29Z",
"publishedDate": "2017-11-21T14:29Z"
}
}
}
ICSA-18-060-01
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting the vulnerabilities to NCCIC"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "summary",
"text": "Siemens ProductCERT reported the vulnerabilities to NCCIC.",
"title": "Summary"
},
{
"category": "other",
"text": "No known public exploits specifically target these vulnerabilities.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "CISAservicedesk@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-18-060-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2018/icsa-18-060-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-18-060-01 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-18-060-01"
}
],
"title": "ICSA-18-060-01_Siemens SIMATIC, SIMOTION, and SINUMERIK (Update A)",
"tracking": {
"current_release_date": "2018-04-19T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA USCert CSAF Generator",
"version": "1"
}
},
"id": "ICSA-18-060-01",
"initial_release_date": "2018-03-01T00:00:00.000000Z",
"revision_history": [
{
"date": "2018-03-01T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-18-060-01 Siemens SIMATIC, SIMOTION, and SINUMERIK"
},
{
"date": "2018-04-19T00:00:00.000000Z",
"legacy_version": "A",
"number": "2",
"summary": "ICSA-18-060-01 Siemens SIMATIC, SIMOTION, and SINUMERIK (Update A)"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 6.2.61.3535",
"product": {
"name": "SINUMERIK PCU50.5-P WINXP: ME prior to V6.2.61.3535",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "SINUMERIK PCU50.5-P WINXP"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 6.2.61.3535",
"product": {
"name": "SINUMERIK PCU50.5-C WINXP: ME prior to V6.2.61.3535",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "SINUMERIK PCU50.5-C WINXP"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 17.0 ?.10",
"product": {
"name": "SIMATIC IPC477D PRO: BIOS prior to V17.0?.10",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC477D PRO"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 6.2.61.3535",
"product": {
"name": "SINUMERIK PCU50.5-C WIN7: ME prior to V6.2.61.3535",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "SINUMERIK PCU50.5-C WIN7"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 9.1.41.3024",
"product": {
"name": "SIMATIC IPC647D: ME prior to V9.1.41.3024",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC647D"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 9.1.41.3024",
"product": {
"name": "SIMATIC IPC847D: ME prior to V9.1.41.3024",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC847D"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 6.2.61.3535",
"product": {
"name": "SIMATIC IPC627C: ME prior to V6.2.61.3535",
"product_id": "CSAFPID-0007"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC627C"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 6.2.61.3535",
"product": {
"name": "SINUMERIK PCU50.5-P WIN7: ME prior to V6.2.61.3535",
"product_id": "CSAFPID-0008"
}
}
],
"category": "product_name",
"name": "SINUMERIK PCU50.5-P WIN7"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 11.8.50.3425 (ME) | \u003c R1.21.0 (BIOS)",
"product": {
"name": "SIMATIC IPC547G: ME prior to V11.8.50.3425 and BIOS prior to R1.21.0",
"product_id": "CSAFPID-0009"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC547G"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c S17.02.06.83.1",
"product": {
"name": "SIMOTION P320-4S: BIOS prior to S17.02.06.83.1",
"product_id": "CSAFPID-00010"
}
}
],
"category": "product_name",
"name": "SIMOTION P320-4S"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 6.2.61.3535",
"product": {
"name": "SIMATIC IPC647C: ME prior to V6.2.61.3535",
"product_id": "CSAFPID-00011"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC647C"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 6.2.61.3535",
"product": {
"name": "SIMATIC Field-PG M3: ME prior to V6.2.61.3535",
"product_id": "CSAFPID-00012"
}
}
],
"category": "product_name",
"name": "SIMATIC Field-PG M3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 17.0 ?.10",
"product": {
"name": "SIMATIC IPC477D: BIOS prior to V17.0?.10",
"product_id": "CSAFPID-00013"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC477D"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 9.1.41.3024",
"product": {
"name": "SIMATIC IPC677D: ME prior to V9.1.41.3024",
"product_id": "CSAFPID-00014"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC677D"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 18.01.06",
"product": {
"name": "SIMATIC Field-PG M4: BIOS prior to V18.01.06",
"product_id": "CSAFPID-00015"
}
}
],
"category": "product_name",
"name": "SIMATIC Field-PG M4"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 9.1.41.3024",
"product": {
"name": "SIMATIC IPC627D: ME prior to V9.1.41.3024",
"product_id": "CSAFPID-00016"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC627D"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 23.01.03",
"product": {
"name": "SIMATIC ITP1000: BIOS prior to V23.01.03",
"product_id": "CSAFPID-00017"
}
}
],
"category": "product_name",
"name": "SIMATIC ITP1000"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 7.1.91.3272",
"product": {
"name": "SIMATIC IPC547D: ME prior to V7.1.91.3272",
"product_id": "CSAFPID-00018"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC547D"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 6.2.61.3535",
"product": {
"name": "SIMATIC IPC847C: ME prior to V6.2.61.3535",
"product_id": "CSAFPID-00019"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC847C"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 22.01.04",
"product": {
"name": "SIMATIC Field-PG M5: BIOS prior to V22.01.04",
"product_id": "CSAFPID-00020"
}
}
],
"category": "product_name",
"name": "SIMATIC Field-PG M5"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 21.01.07",
"product": {
"name": "SIMATIC IPC477E: BIOS prior to V21.01.07",
"product_id": "CSAFPID-00021"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC477E"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 17.0 ?.10",
"product": {
"name": "SIMATIC IPC427D: BIOS prior to V17.0?.10",
"product_id": "CSAFPID-00022"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC427D"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 9.1.41.3024",
"product": {
"name": "SIMATIC IPC827D: ME prior to V9.1.41.3024",
"product_id": "CSAFPID-00023"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC827D"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 6.2.61.3535",
"product": {
"name": "SIMATIC HMI IPC677C: ME prior to V6.2.61.3535",
"product_id": "CSAFPID-00024"
}
}
],
"category": "product_name",
"name": "SIMATIC HMI IPC677C"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 21.01.07",
"product": {
"name": "SIMATIC IPC427E: BIOS prior to V21.01.07",
"product_id": "CSAFPID-00025"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC427E"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 9.1.41.3024",
"product": {
"name": "SIMATIC IPC547E: ME prior to V9.1.41.3024",
"product_id": "CSAFPID-00026"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC547E"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 6.2.61.3535",
"product": {
"name": "SIMATIC IPC827C: ME prior to V6.2.61.3535",
"product_id": "CSAFPID-00027"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC827C"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2017-5705",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"category": "summary",
"text": "Multiple buffer overflows could allow attackers to execute arbitrary code. Local access to the system is required to exploit this vulnerability. CVE-2017-5705, CVE-2017-5706, and CVE-2017-5707 have been assigned to these vulnerabilities. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to run the devices in a protected IT environment, Siemens particularly recommends users configure the environment according to Siemens\u0027 Operational Guidelines for Industrial Security, and follow the recommendations in the product manuals. See the Operational Guidelines for Industrial Security",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013",
"CSAFPID-00014",
"CSAFPID-00015",
"CSAFPID-00016",
"CSAFPID-00017",
"CSAFPID-00018",
"CSAFPID-00019",
"CSAFPID-00020",
"CSAFPID-00021",
"CSAFPID-00022",
"CSAFPID-00023",
"CSAFPID-00024",
"CSAFPID-00025",
"CSAFPID-00026",
"CSAFPID-00027"
],
"url": "https://www.siemens.com/cert/operational-guidelines-industrial-security"
},
{
"category": "mitigation",
"details": "Additional information on Industrial Security by Siemens",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013",
"CSAFPID-00014",
"CSAFPID-00015",
"CSAFPID-00016",
"CSAFPID-00017",
"CSAFPID-00018",
"CSAFPID-00019",
"CSAFPID-00020",
"CSAFPID-00021",
"CSAFPID-00022",
"CSAFPID-00023",
"CSAFPID-00024",
"CSAFPID-00025",
"CSAFPID-00026",
"CSAFPID-00027"
],
"url": "https://www.siemens.com/global/en/home/company/topic-areas/future-of-manufacturing/industrial-security.html"
},
{
"category": "vendor_fix",
"details": "SIMATIC Field-PG M3: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00012"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48791866"
},
{
"category": "vendor_fix",
"details": "SIMATIC Field-PG M4: Update to V18.01.06 or higher, which can be located here",
"product_ids": [
"CSAFPID-00015"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109037537"
},
{
"category": "vendor_fix",
"details": "SIMATIC Field-PG M5: Update to V22.01.04 or higher, which can be located here",
"product_ids": [
"CSAFPID-00020"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109738122"
},
{
"category": "vendor_fix",
"details": "SIMATIC HMI IPC677C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00024"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC427D: Update to V17.0?.10 or higher, which can be located here",
"product_ids": [
"CSAFPID-00022"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/108608500"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC427E: Update to V21.01.07 or higher, which can located here",
"product_ids": [
"CSAFPID-00025"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109742593"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC477D: Update to V17.0?.10 or higher, which can located here",
"product_ids": [
"CSAFPID-00013"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/108608500"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC477D PRO: Update to V17.0?.10 or higher, which can located here",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/108608500"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC477E: Update to V21.01.07 or higher, which can be located here",
"product_ids": [
"CSAFPID-00021"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109742593"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC547D: Update to V7.1.91.3272 or higher, which can be located here",
"product_ids": [
"CSAFPID-00018"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/67329515"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC547E: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00026"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109481624"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC547G: Update to V11.8.50.3425 and R1.21.0 or higher, which can be located here",
"product_ids": [
"CSAFPID-0009"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109750349"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC627C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0007"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC627D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00016"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109474954"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC647C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00011"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792076"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC647D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-0005"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109037779"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC677D: Install V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00014"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109474954"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC827C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00027"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC827D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00023"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109474954"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC847C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00019"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792076"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC847D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109037779"
},
{
"category": "vendor_fix",
"details": "SIMATIC ITP1000: Update to V23.01.03 or higher, which can be located here",
"product_ids": [
"CSAFPID-00017"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109748173"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-C, WIN7: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087%20"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-C, WINXP: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-P, WIN7: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0008"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-P, WINXP: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMOTION P320-4S: Update to S17.02.06.83.1 or higher, which can be located here",
"product_ids": [
"CSAFPID-00012"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109756438"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013",
"CSAFPID-00014",
"CSAFPID-00015",
"CSAFPID-00016",
"CSAFPID-00017",
"CSAFPID-00018",
"CSAFPID-00019",
"CSAFPID-00020",
"CSAFPID-00021",
"CSAFPID-00022",
"CSAFPID-00023",
"CSAFPID-00024",
"CSAFPID-00025",
"CSAFPID-00026",
"CSAFPID-00027"
]
}
],
"title": "CVE-2017-5705"
},
{
"cve": "CVE-2017-5706",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"category": "summary",
"text": "A buffer overflow could allow remote authenticated attackers to execute arbitrary code with extended privileges.CVE-2017-5712 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to run the devices in a protected IT environment, Siemens particularly recommends users configure the environment according to Siemens\u0027 Operational Guidelines for Industrial Security, and follow the recommendations in the product manuals. See the Operational Guidelines for Industrial Security",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013",
"CSAFPID-00014",
"CSAFPID-00015",
"CSAFPID-00016",
"CSAFPID-00017",
"CSAFPID-00018",
"CSAFPID-00019",
"CSAFPID-00020",
"CSAFPID-00021",
"CSAFPID-00022",
"CSAFPID-00023",
"CSAFPID-00024",
"CSAFPID-00025",
"CSAFPID-00026",
"CSAFPID-00027"
],
"url": "https://www.siemens.com/cert/operational-guidelines-industrial-security"
},
{
"category": "mitigation",
"details": "Additional information on Industrial Security by Siemens",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013",
"CSAFPID-00014",
"CSAFPID-00015",
"CSAFPID-00016",
"CSAFPID-00017",
"CSAFPID-00018",
"CSAFPID-00019",
"CSAFPID-00020",
"CSAFPID-00021",
"CSAFPID-00022",
"CSAFPID-00023",
"CSAFPID-00024",
"CSAFPID-00025",
"CSAFPID-00026",
"CSAFPID-00027"
],
"url": "https://www.siemens.com/global/en/home/company/topic-areas/future-of-manufacturing/industrial-security.html"
},
{
"category": "vendor_fix",
"details": "SIMATIC Field-PG M3: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00012"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48791866"
},
{
"category": "vendor_fix",
"details": "SIMATIC Field-PG M4: Update to V18.01.06 or higher, which can be located here",
"product_ids": [
"CSAFPID-00015"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109037537"
},
{
"category": "vendor_fix",
"details": "SIMATIC Field-PG M5: Update to V22.01.04 or higher, which can be located here",
"product_ids": [
"CSAFPID-00020"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109738122"
},
{
"category": "vendor_fix",
"details": "SIMATIC HMI IPC677C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00024"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC427D: Update to V17.0?.10 or higher, which can be located here",
"product_ids": [
"CSAFPID-00022"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/108608500"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC427E: Update to V21.01.07 or higher, which can located here",
"product_ids": [
"CSAFPID-00025"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109742593"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC477D: Update to V17.0?.10 or higher, which can located here",
"product_ids": [
"CSAFPID-00013"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/108608500"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC477D PRO: Update to V17.0?.10 or higher, which can located here",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/108608500"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC477E: Update to V21.01.07 or higher, which can be located here",
"product_ids": [
"CSAFPID-00021"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109742593"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC547D: Update to V7.1.91.3272 or higher, which can be located here",
"product_ids": [
"CSAFPID-00018"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/67329515"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC547E: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00026"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109481624"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC547G: Update to V11.8.50.3425 and R1.21.0 or higher, which can be located here",
"product_ids": [
"CSAFPID-0009"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109750349"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC627C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0007"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC627D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00016"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109474954"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC647C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00011"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792076"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC647D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-0005"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109037779"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC677D: Install V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00014"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109474954"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC827C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00027"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC827D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00023"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109474954"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC847C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00019"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792076"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC847D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109037779"
},
{
"category": "vendor_fix",
"details": "SIMATIC ITP1000: Update to V23.01.03 or higher, which can be located here",
"product_ids": [
"CSAFPID-00017"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109748173"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-C, WIN7: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087%20"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-C, WINXP: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-P, WIN7: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0008"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-P, WINXP: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMOTION P320-4S: Update to S17.02.06.83.1 or higher, which can be located here",
"product_ids": [
"CSAFPID-00012"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109756438"
}
],
"title": "CVE-2017-5706"
},
{
"cve": "CVE-2017-5707",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"category": "summary",
"text": "Multiple privilege escalations could allow unauthenticated access to sensitive data.CVE-2017-5708, CVE-2017-5709, and CVE-2017-5710 have been assigned to these vulnerabilities. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:N).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to run the devices in a protected IT environment, Siemens particularly recommends users configure the environment according to Siemens\u0027 Operational Guidelines for Industrial Security, and follow the recommendations in the product manuals. See the Operational Guidelines for Industrial Security",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013",
"CSAFPID-00014",
"CSAFPID-00015",
"CSAFPID-00016",
"CSAFPID-00017",
"CSAFPID-00018",
"CSAFPID-00019",
"CSAFPID-00020",
"CSAFPID-00021",
"CSAFPID-00022",
"CSAFPID-00023",
"CSAFPID-00024",
"CSAFPID-00025",
"CSAFPID-00026",
"CSAFPID-00027"
],
"url": "https://www.siemens.com/cert/operational-guidelines-industrial-security"
},
{
"category": "mitigation",
"details": "Additional information on Industrial Security by Siemens",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013",
"CSAFPID-00014",
"CSAFPID-00015",
"CSAFPID-00016",
"CSAFPID-00017",
"CSAFPID-00018",
"CSAFPID-00019",
"CSAFPID-00020",
"CSAFPID-00021",
"CSAFPID-00022",
"CSAFPID-00023",
"CSAFPID-00024",
"CSAFPID-00025",
"CSAFPID-00026",
"CSAFPID-00027"
],
"url": "https://www.siemens.com/global/en/home/company/topic-areas/future-of-manufacturing/industrial-security.html"
},
{
"category": "vendor_fix",
"details": "SIMATIC Field-PG M3: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00012"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48791866"
},
{
"category": "vendor_fix",
"details": "SIMATIC Field-PG M4: Update to V18.01.06 or higher, which can be located here",
"product_ids": [
"CSAFPID-00015"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109037537"
},
{
"category": "vendor_fix",
"details": "SIMATIC Field-PG M5: Update to V22.01.04 or higher, which can be located here",
"product_ids": [
"CSAFPID-00020"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109738122"
},
{
"category": "vendor_fix",
"details": "SIMATIC HMI IPC677C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00024"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC427D: Update to V17.0?.10 or higher, which can be located here",
"product_ids": [
"CSAFPID-00022"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/108608500"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC427E: Update to V21.01.07 or higher, which can located here",
"product_ids": [
"CSAFPID-00025"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109742593"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC477D: Update to V17.0?.10 or higher, which can located here",
"product_ids": [
"CSAFPID-00013"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/108608500"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC477D PRO: Update to V17.0?.10 or higher, which can located here",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/108608500"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC477E: Update to V21.01.07 or higher, which can be located here",
"product_ids": [
"CSAFPID-00021"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109742593"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC547D: Update to V7.1.91.3272 or higher, which can be located here",
"product_ids": [
"CSAFPID-00018"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/67329515"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC547E: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00026"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109481624"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC547G: Update to V11.8.50.3425 and R1.21.0 or higher, which can be located here",
"product_ids": [
"CSAFPID-0009"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109750349"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC627C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0007"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC627D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00016"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109474954"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC647C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00011"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792076"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC647D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-0005"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109037779"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC677D: Install V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00014"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109474954"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC827C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00027"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC827D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00023"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109474954"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC847C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00019"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792076"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC847D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109037779"
},
{
"category": "vendor_fix",
"details": "SIMATIC ITP1000: Update to V23.01.03 or higher, which can be located here",
"product_ids": [
"CSAFPID-00017"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109748173"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-C, WIN7: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087%20"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-C, WINXP: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-P, WIN7: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0008"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-P, WINXP: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMOTION P320-4S: Update to S17.02.06.83.1 or higher, which can be located here",
"product_ids": [
"CSAFPID-00012"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109756438"
}
],
"title": "CVE-2017-5707"
}
]
}
icsa-18-060-01
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting the vulnerabilities to NCCIC"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "summary",
"text": "Siemens ProductCERT reported the vulnerabilities to NCCIC.",
"title": "Summary"
},
{
"category": "other",
"text": "No known public exploits specifically target these vulnerabilities.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "CISAservicedesk@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-18-060-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2018/icsa-18-060-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-18-060-01 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-18-060-01"
}
],
"title": "ICSA-18-060-01_Siemens SIMATIC, SIMOTION, and SINUMERIK (Update A)",
"tracking": {
"current_release_date": "2018-04-19T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA USCert CSAF Generator",
"version": "1"
}
},
"id": "ICSA-18-060-01",
"initial_release_date": "2018-03-01T00:00:00.000000Z",
"revision_history": [
{
"date": "2018-03-01T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-18-060-01 Siemens SIMATIC, SIMOTION, and SINUMERIK"
},
{
"date": "2018-04-19T00:00:00.000000Z",
"legacy_version": "A",
"number": "2",
"summary": "ICSA-18-060-01 Siemens SIMATIC, SIMOTION, and SINUMERIK (Update A)"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 6.2.61.3535",
"product": {
"name": "SINUMERIK PCU50.5-P WINXP: ME prior to V6.2.61.3535",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "SINUMERIK PCU50.5-P WINXP"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 6.2.61.3535",
"product": {
"name": "SINUMERIK PCU50.5-C WINXP: ME prior to V6.2.61.3535",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "SINUMERIK PCU50.5-C WINXP"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 17.0 ?.10",
"product": {
"name": "SIMATIC IPC477D PRO: BIOS prior to V17.0?.10",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC477D PRO"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 6.2.61.3535",
"product": {
"name": "SINUMERIK PCU50.5-C WIN7: ME prior to V6.2.61.3535",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "SINUMERIK PCU50.5-C WIN7"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 9.1.41.3024",
"product": {
"name": "SIMATIC IPC647D: ME prior to V9.1.41.3024",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC647D"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 9.1.41.3024",
"product": {
"name": "SIMATIC IPC847D: ME prior to V9.1.41.3024",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC847D"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 6.2.61.3535",
"product": {
"name": "SIMATIC IPC627C: ME prior to V6.2.61.3535",
"product_id": "CSAFPID-0007"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC627C"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 6.2.61.3535",
"product": {
"name": "SINUMERIK PCU50.5-P WIN7: ME prior to V6.2.61.3535",
"product_id": "CSAFPID-0008"
}
}
],
"category": "product_name",
"name": "SINUMERIK PCU50.5-P WIN7"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 11.8.50.3425 (ME) | \u003c R1.21.0 (BIOS)",
"product": {
"name": "SIMATIC IPC547G: ME prior to V11.8.50.3425 and BIOS prior to R1.21.0",
"product_id": "CSAFPID-0009"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC547G"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c S17.02.06.83.1",
"product": {
"name": "SIMOTION P320-4S: BIOS prior to S17.02.06.83.1",
"product_id": "CSAFPID-00010"
}
}
],
"category": "product_name",
"name": "SIMOTION P320-4S"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 6.2.61.3535",
"product": {
"name": "SIMATIC IPC647C: ME prior to V6.2.61.3535",
"product_id": "CSAFPID-00011"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC647C"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 6.2.61.3535",
"product": {
"name": "SIMATIC Field-PG M3: ME prior to V6.2.61.3535",
"product_id": "CSAFPID-00012"
}
}
],
"category": "product_name",
"name": "SIMATIC Field-PG M3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 17.0 ?.10",
"product": {
"name": "SIMATIC IPC477D: BIOS prior to V17.0?.10",
"product_id": "CSAFPID-00013"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC477D"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 9.1.41.3024",
"product": {
"name": "SIMATIC IPC677D: ME prior to V9.1.41.3024",
"product_id": "CSAFPID-00014"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC677D"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 18.01.06",
"product": {
"name": "SIMATIC Field-PG M4: BIOS prior to V18.01.06",
"product_id": "CSAFPID-00015"
}
}
],
"category": "product_name",
"name": "SIMATIC Field-PG M4"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 9.1.41.3024",
"product": {
"name": "SIMATIC IPC627D: ME prior to V9.1.41.3024",
"product_id": "CSAFPID-00016"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC627D"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 23.01.03",
"product": {
"name": "SIMATIC ITP1000: BIOS prior to V23.01.03",
"product_id": "CSAFPID-00017"
}
}
],
"category": "product_name",
"name": "SIMATIC ITP1000"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 7.1.91.3272",
"product": {
"name": "SIMATIC IPC547D: ME prior to V7.1.91.3272",
"product_id": "CSAFPID-00018"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC547D"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 6.2.61.3535",
"product": {
"name": "SIMATIC IPC847C: ME prior to V6.2.61.3535",
"product_id": "CSAFPID-00019"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC847C"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 22.01.04",
"product": {
"name": "SIMATIC Field-PG M5: BIOS prior to V22.01.04",
"product_id": "CSAFPID-00020"
}
}
],
"category": "product_name",
"name": "SIMATIC Field-PG M5"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 21.01.07",
"product": {
"name": "SIMATIC IPC477E: BIOS prior to V21.01.07",
"product_id": "CSAFPID-00021"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC477E"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 17.0 ?.10",
"product": {
"name": "SIMATIC IPC427D: BIOS prior to V17.0?.10",
"product_id": "CSAFPID-00022"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC427D"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 9.1.41.3024",
"product": {
"name": "SIMATIC IPC827D: ME prior to V9.1.41.3024",
"product_id": "CSAFPID-00023"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC827D"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 6.2.61.3535",
"product": {
"name": "SIMATIC HMI IPC677C: ME prior to V6.2.61.3535",
"product_id": "CSAFPID-00024"
}
}
],
"category": "product_name",
"name": "SIMATIC HMI IPC677C"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 21.01.07",
"product": {
"name": "SIMATIC IPC427E: BIOS prior to V21.01.07",
"product_id": "CSAFPID-00025"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC427E"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 9.1.41.3024",
"product": {
"name": "SIMATIC IPC547E: ME prior to V9.1.41.3024",
"product_id": "CSAFPID-00026"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC547E"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 6.2.61.3535",
"product": {
"name": "SIMATIC IPC827C: ME prior to V6.2.61.3535",
"product_id": "CSAFPID-00027"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC827C"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2017-5705",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"category": "summary",
"text": "Multiple buffer overflows could allow attackers to execute arbitrary code. Local access to the system is required to exploit this vulnerability. CVE-2017-5705, CVE-2017-5706, and CVE-2017-5707 have been assigned to these vulnerabilities. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to run the devices in a protected IT environment, Siemens particularly recommends users configure the environment according to Siemens\u0027 Operational Guidelines for Industrial Security, and follow the recommendations in the product manuals. See the Operational Guidelines for Industrial Security",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013",
"CSAFPID-00014",
"CSAFPID-00015",
"CSAFPID-00016",
"CSAFPID-00017",
"CSAFPID-00018",
"CSAFPID-00019",
"CSAFPID-00020",
"CSAFPID-00021",
"CSAFPID-00022",
"CSAFPID-00023",
"CSAFPID-00024",
"CSAFPID-00025",
"CSAFPID-00026",
"CSAFPID-00027"
],
"url": "https://www.siemens.com/cert/operational-guidelines-industrial-security"
},
{
"category": "mitigation",
"details": "Additional information on Industrial Security by Siemens",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013",
"CSAFPID-00014",
"CSAFPID-00015",
"CSAFPID-00016",
"CSAFPID-00017",
"CSAFPID-00018",
"CSAFPID-00019",
"CSAFPID-00020",
"CSAFPID-00021",
"CSAFPID-00022",
"CSAFPID-00023",
"CSAFPID-00024",
"CSAFPID-00025",
"CSAFPID-00026",
"CSAFPID-00027"
],
"url": "https://www.siemens.com/global/en/home/company/topic-areas/future-of-manufacturing/industrial-security.html"
},
{
"category": "vendor_fix",
"details": "SIMATIC Field-PG M3: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00012"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48791866"
},
{
"category": "vendor_fix",
"details": "SIMATIC Field-PG M4: Update to V18.01.06 or higher, which can be located here",
"product_ids": [
"CSAFPID-00015"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109037537"
},
{
"category": "vendor_fix",
"details": "SIMATIC Field-PG M5: Update to V22.01.04 or higher, which can be located here",
"product_ids": [
"CSAFPID-00020"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109738122"
},
{
"category": "vendor_fix",
"details": "SIMATIC HMI IPC677C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00024"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC427D: Update to V17.0?.10 or higher, which can be located here",
"product_ids": [
"CSAFPID-00022"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/108608500"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC427E: Update to V21.01.07 or higher, which can located here",
"product_ids": [
"CSAFPID-00025"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109742593"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC477D: Update to V17.0?.10 or higher, which can located here",
"product_ids": [
"CSAFPID-00013"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/108608500"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC477D PRO: Update to V17.0?.10 or higher, which can located here",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/108608500"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC477E: Update to V21.01.07 or higher, which can be located here",
"product_ids": [
"CSAFPID-00021"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109742593"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC547D: Update to V7.1.91.3272 or higher, which can be located here",
"product_ids": [
"CSAFPID-00018"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/67329515"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC547E: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00026"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109481624"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC547G: Update to V11.8.50.3425 and R1.21.0 or higher, which can be located here",
"product_ids": [
"CSAFPID-0009"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109750349"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC627C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0007"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC627D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00016"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109474954"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC647C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00011"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792076"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC647D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-0005"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109037779"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC677D: Install V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00014"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109474954"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC827C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00027"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC827D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00023"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109474954"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC847C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00019"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792076"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC847D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109037779"
},
{
"category": "vendor_fix",
"details": "SIMATIC ITP1000: Update to V23.01.03 or higher, which can be located here",
"product_ids": [
"CSAFPID-00017"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109748173"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-C, WIN7: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087%20"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-C, WINXP: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-P, WIN7: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0008"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-P, WINXP: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMOTION P320-4S: Update to S17.02.06.83.1 or higher, which can be located here",
"product_ids": [
"CSAFPID-00012"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109756438"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013",
"CSAFPID-00014",
"CSAFPID-00015",
"CSAFPID-00016",
"CSAFPID-00017",
"CSAFPID-00018",
"CSAFPID-00019",
"CSAFPID-00020",
"CSAFPID-00021",
"CSAFPID-00022",
"CSAFPID-00023",
"CSAFPID-00024",
"CSAFPID-00025",
"CSAFPID-00026",
"CSAFPID-00027"
]
}
],
"title": "CVE-2017-5705"
},
{
"cve": "CVE-2017-5706",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"category": "summary",
"text": "A buffer overflow could allow remote authenticated attackers to execute arbitrary code with extended privileges.CVE-2017-5712 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to run the devices in a protected IT environment, Siemens particularly recommends users configure the environment according to Siemens\u0027 Operational Guidelines for Industrial Security, and follow the recommendations in the product manuals. See the Operational Guidelines for Industrial Security",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013",
"CSAFPID-00014",
"CSAFPID-00015",
"CSAFPID-00016",
"CSAFPID-00017",
"CSAFPID-00018",
"CSAFPID-00019",
"CSAFPID-00020",
"CSAFPID-00021",
"CSAFPID-00022",
"CSAFPID-00023",
"CSAFPID-00024",
"CSAFPID-00025",
"CSAFPID-00026",
"CSAFPID-00027"
],
"url": "https://www.siemens.com/cert/operational-guidelines-industrial-security"
},
{
"category": "mitigation",
"details": "Additional information on Industrial Security by Siemens",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013",
"CSAFPID-00014",
"CSAFPID-00015",
"CSAFPID-00016",
"CSAFPID-00017",
"CSAFPID-00018",
"CSAFPID-00019",
"CSAFPID-00020",
"CSAFPID-00021",
"CSAFPID-00022",
"CSAFPID-00023",
"CSAFPID-00024",
"CSAFPID-00025",
"CSAFPID-00026",
"CSAFPID-00027"
],
"url": "https://www.siemens.com/global/en/home/company/topic-areas/future-of-manufacturing/industrial-security.html"
},
{
"category": "vendor_fix",
"details": "SIMATIC Field-PG M3: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00012"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48791866"
},
{
"category": "vendor_fix",
"details": "SIMATIC Field-PG M4: Update to V18.01.06 or higher, which can be located here",
"product_ids": [
"CSAFPID-00015"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109037537"
},
{
"category": "vendor_fix",
"details": "SIMATIC Field-PG M5: Update to V22.01.04 or higher, which can be located here",
"product_ids": [
"CSAFPID-00020"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109738122"
},
{
"category": "vendor_fix",
"details": "SIMATIC HMI IPC677C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00024"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC427D: Update to V17.0?.10 or higher, which can be located here",
"product_ids": [
"CSAFPID-00022"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/108608500"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC427E: Update to V21.01.07 or higher, which can located here",
"product_ids": [
"CSAFPID-00025"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109742593"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC477D: Update to V17.0?.10 or higher, which can located here",
"product_ids": [
"CSAFPID-00013"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/108608500"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC477D PRO: Update to V17.0?.10 or higher, which can located here",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/108608500"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC477E: Update to V21.01.07 or higher, which can be located here",
"product_ids": [
"CSAFPID-00021"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109742593"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC547D: Update to V7.1.91.3272 or higher, which can be located here",
"product_ids": [
"CSAFPID-00018"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/67329515"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC547E: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00026"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109481624"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC547G: Update to V11.8.50.3425 and R1.21.0 or higher, which can be located here",
"product_ids": [
"CSAFPID-0009"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109750349"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC627C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0007"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC627D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00016"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109474954"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC647C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00011"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792076"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC647D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-0005"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109037779"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC677D: Install V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00014"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109474954"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC827C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00027"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC827D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00023"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109474954"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC847C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00019"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792076"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC847D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109037779"
},
{
"category": "vendor_fix",
"details": "SIMATIC ITP1000: Update to V23.01.03 or higher, which can be located here",
"product_ids": [
"CSAFPID-00017"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109748173"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-C, WIN7: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087%20"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-C, WINXP: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-P, WIN7: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0008"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-P, WINXP: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMOTION P320-4S: Update to S17.02.06.83.1 or higher, which can be located here",
"product_ids": [
"CSAFPID-00012"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109756438"
}
],
"title": "CVE-2017-5706"
},
{
"cve": "CVE-2017-5707",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"category": "summary",
"text": "Multiple privilege escalations could allow unauthenticated access to sensitive data.CVE-2017-5708, CVE-2017-5709, and CVE-2017-5710 have been assigned to these vulnerabilities. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:N).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to run the devices in a protected IT environment, Siemens particularly recommends users configure the environment according to Siemens\u0027 Operational Guidelines for Industrial Security, and follow the recommendations in the product manuals. See the Operational Guidelines for Industrial Security",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013",
"CSAFPID-00014",
"CSAFPID-00015",
"CSAFPID-00016",
"CSAFPID-00017",
"CSAFPID-00018",
"CSAFPID-00019",
"CSAFPID-00020",
"CSAFPID-00021",
"CSAFPID-00022",
"CSAFPID-00023",
"CSAFPID-00024",
"CSAFPID-00025",
"CSAFPID-00026",
"CSAFPID-00027"
],
"url": "https://www.siemens.com/cert/operational-guidelines-industrial-security"
},
{
"category": "mitigation",
"details": "Additional information on Industrial Security by Siemens",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013",
"CSAFPID-00014",
"CSAFPID-00015",
"CSAFPID-00016",
"CSAFPID-00017",
"CSAFPID-00018",
"CSAFPID-00019",
"CSAFPID-00020",
"CSAFPID-00021",
"CSAFPID-00022",
"CSAFPID-00023",
"CSAFPID-00024",
"CSAFPID-00025",
"CSAFPID-00026",
"CSAFPID-00027"
],
"url": "https://www.siemens.com/global/en/home/company/topic-areas/future-of-manufacturing/industrial-security.html"
},
{
"category": "vendor_fix",
"details": "SIMATIC Field-PG M3: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00012"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48791866"
},
{
"category": "vendor_fix",
"details": "SIMATIC Field-PG M4: Update to V18.01.06 or higher, which can be located here",
"product_ids": [
"CSAFPID-00015"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109037537"
},
{
"category": "vendor_fix",
"details": "SIMATIC Field-PG M5: Update to V22.01.04 or higher, which can be located here",
"product_ids": [
"CSAFPID-00020"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109738122"
},
{
"category": "vendor_fix",
"details": "SIMATIC HMI IPC677C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00024"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC427D: Update to V17.0?.10 or higher, which can be located here",
"product_ids": [
"CSAFPID-00022"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/108608500"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC427E: Update to V21.01.07 or higher, which can located here",
"product_ids": [
"CSAFPID-00025"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109742593"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC477D: Update to V17.0?.10 or higher, which can located here",
"product_ids": [
"CSAFPID-00013"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/108608500"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC477D PRO: Update to V17.0?.10 or higher, which can located here",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/108608500"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC477E: Update to V21.01.07 or higher, which can be located here",
"product_ids": [
"CSAFPID-00021"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109742593"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC547D: Update to V7.1.91.3272 or higher, which can be located here",
"product_ids": [
"CSAFPID-00018"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/67329515"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC547E: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00026"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109481624"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC547G: Update to V11.8.50.3425 and R1.21.0 or higher, which can be located here",
"product_ids": [
"CSAFPID-0009"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109750349"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC627C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0007"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC627D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00016"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109474954"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC647C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00011"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792076"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC647D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-0005"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109037779"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC677D: Install V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00014"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109474954"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC827C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00027"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC827D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-00023"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109474954"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC847C: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-00019"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792076"
},
{
"category": "vendor_fix",
"details": "SIMATIC IPC847D: Update to V9.1.41.3024 or higher, which can be located here",
"product_ids": [
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109037779"
},
{
"category": "vendor_fix",
"details": "SIMATIC ITP1000: Update to V23.01.03 or higher, which can be located here",
"product_ids": [
"CSAFPID-00017"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109748173"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-C, WIN7: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087%20"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-C, WINXP: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-P, WIN7: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0008"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SINUMERIK PCU50.5-P, WINXP: Update to V6.2.61.3535 or higher, which can be located here",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/48792087"
},
{
"category": "vendor_fix",
"details": "SIMOTION P320-4S: Update to S17.02.06.83.1 or higher, which can be located here",
"product_ids": [
"CSAFPID-00012"
],
"url": "https://support.industry.siemens.com/cs/ww/en/%20view/109756438"
}
],
"title": "CVE-2017-5707"
}
]
}
CERTFR-2017-AVI-423
Vulnerability from certfr_avis
Le 1er mai 2017 [1], une vulnérabilité concernant Intel AMT permettait à un attaquant de provoquer une exécution de code arbitraire à distance et une élévation de privilèges sur des machines comportant un modèle de processeur Intel habituellement utilisé par les entreprises.
Le 20 novembre 2017 [2][3], un article annonce l’identification de nouvelles vulnérabilités critiques dans IME et AMT pour les processeurs Intel. Les processeurs concernés correspondent autant à des modèles d’entreprise qu'à des modèles pour particuliers.
Intel propose un outil permettant de détecter les processeurs affectés par cette vulnérabilité [4].
L’exploitation de ces vulnérabilités permet à un attaquant ayant un accès local à la machine d’altérer l’intégrité de la chaîne de démarrage et d’exécuter du code arbitraire à l’insu du système d’exploitation, même lorsque la machine est éteinte.
Ces vulnérabilités concernent une vaste gamme de processeurs : des versions de processeurs récentes disponible pour les particuliers dont la vente commence début 2016, comme de plus anciens destinés aux entreprises datant de 2011.
A ce jour, il n’existe pas de code disponible publiquement exploitant ces vulnérabilités. Potentiellement, un tel code pourrait permettre :
- Une exécution de code arbitraire dans le contexte d’IME et, par conséquent, des modules basés dessus, tels que AMT ou PTT (Plateform Trust Technology) ;
- d’impacter les mécanismes d’attestation de validité de la machine, tel que la désactivation du Secure Boot, grâce à la compromission d’AMT ;
- de charger et exécuter du code arbitraire dans le contexte d’AMT, par exemple pour charger une session VNC à l’insu du système d’exploitation ;
- de récupérer des informations contenues dans la plateforme Intel PTT, telles que des clés de Bitlocker.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
- Intel Manageability Engine Firmware (IME) 8.x/9.x/10.x/11.0/11.5/11.6/11.7/11.10/11.20
- Intel Server Platform Services (SPS) Firmware 4.0
- Intel Trusted Execution Engine (TXE) Firmware 3.0
On retrouve ces microgiciels dans les produits d'Intel suivants :
- Générations 6, 7 et 8 de la famille de processeur Intel Core
- Processeur Intel Xeon E3-1200 v5 et v6
- Processeur Intel Xeon Scalable
- Processeur Intel Xeon W
- Processeur Intel Atom C3000
- Processeur Apollo Lake Intel Atom série E3900
- Processeur Apollo Lake Intel Pentium
- Processeur Celeron séries N and J
| Vendor | Product | Description |
|---|
| Title | Publication Time | Tags | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [],
"affected_systems_content": "\u003cul\u003e \u003cli\u003eIntel Manageability Engine Firmware (IME) 8.x/9.x/10.x/11.0/11.5/11.6/11.7/11.10/11.20\u003c/li\u003e \u003cli\u003eIntel Server Platform Services (SPS) Firmware 4.0\u003c/li\u003e \u003cli\u003eIntel Trusted Execution Engine (TXE) Firmware 3.0\u003c/li\u003e \u003c/ul\u003e \u003cp\u003eOn retrouve ces microgiciels dans les produits d\u0027Intel suivants :\u003c/p\u003e \u003cul\u003e \u003cli\u003e\u00a0 G\u00e9n\u00e9rations 6, 7 et 8 de la famille de processeur Intel Core\u003c/li\u003e \u003cli\u003e\u00a0 Processeur Intel Xeon E3-1200 v5 et v6\u003c/li\u003e \u003cli\u003e\u00a0 Processeur Intel Xeon Scalable\u003c/li\u003e \u003cli\u003e\u00a0 Processeur Intel Xeon W\u003c/li\u003e \u003cli\u003e\u00a0 Processeur Intel Atom C3000\u003c/li\u003e \u003cli\u003e\u00a0 Processeur Apollo Lake Intel Atom s\u00e9rie E3900\u003c/li\u003e \u003cli\u003e\u00a0 Processeur Apollo Lake Intel Pentium\u003c/li\u003e \u003cli\u003e\u00a0 Processeur Celeron s\u00e9ries N and J\u003c/li\u003e \u003c/ul\u003e ",
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2017-5705",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-5705"
},
{
"name": "CVE-2017-5708",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-5708"
},
{
"name": "CVE-2017-5710",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-5710"
},
{
"name": "CVE-2017-5706",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-5706"
},
{
"name": "CVE-2017-5712",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-5712"
},
{
"name": "CVE-2017-5707",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-5707"
},
{
"name": "CVE-2017-5709",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-5709"
},
{
"name": "CVE-2017-5711",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-5711"
}
],
"initial_release_date": "2017-11-21T00:00:00",
"last_revision_date": "2017-11-21T00:00:00",
"links": [
{
"title": "Outil de d\u00e9tection de la vuln\u00e9rabilit\u00e9 relatif au bulletin Intel SA-00086",
"url": "https://downloadcenter.intel.com/download/27150"
},
{
"title": "Avis CERTFR-2017-AVI-136",
"url": "https://www.cert.ssi.gouv.fr/avis/CERTFR-2017-AVI-136/"
},
{
"title": "Support Intel relatif au bulletin Intel SA-00086 pour la mise \u00e0 jour du logiciel Intel Management Engine",
"url": "https://www.intel.com/content/www/us/en/support/articles/000025619/software.html"
}
],
"reference": "CERTFR-2017-AVI-423",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2017-11-21T00:00:00.000000"
},
{
"description": "Version initiale",
"revision_date": "2017-11-21T00:00:00.000000"
}
],
"risks": [
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Ex\u00e9cution de code arbitraire"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "Le 1er mai 2017 \\[1\\], une vuln\u00e9rabilit\u00e9 concernant Intel AMT permettait\n\u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire \u00e0 distance\net une \u00e9l\u00e9vation de privil\u00e8ges sur des machines comportant un mod\u00e8le de\nprocesseur Intel habituellement utilis\u00e9 par les entreprises.\n\nLe 20 novembre 2017 \\[2\\]\\[3\\], un article annonce l\u2019identification de\nnouvelles vuln\u00e9rabilit\u00e9s critiques dans IME et AMT pour les processeurs\nIntel. Les processeurs concern\u00e9s correspondent autant \u00e0 des mod\u00e8les\nd\u2019entreprise qu\u0027\u00e0 des mod\u00e8les pour particuliers.\n\nIntel propose un outil permettant de d\u00e9tecter les processeurs affect\u00e9s\npar cette vuln\u00e9rabilit\u00e9 \\[4\\].\n\nL\u2019exploitation de ces vuln\u00e9rabilit\u00e9s permet \u00e0 un attaquant ayant un\nacc\u00e8s local \u00e0 la machine d\u2019alt\u00e9rer l\u2019int\u00e9grit\u00e9 de la cha\u00eene de d\u00e9marrage\net d\u2019ex\u00e9cuter du code arbitraire \u00e0 l\u2019insu du syst\u00e8me d\u2019exploitation,\nm\u00eame lorsque la machine est \u00e9teinte.\n\nCes vuln\u00e9rabilit\u00e9s concernent une vaste gamme de processeurs : des\nversions de processeurs r\u00e9centes disponible pour les particuliers dont\nla vente commence d\u00e9but 2016, comme de plus anciens destin\u00e9s aux\nentreprises datant de 2011.\n\nA ce jour, il n\u2019existe pas de code disponible publiquement exploitant\nces vuln\u00e9rabilit\u00e9s. Potentiellement, un tel code pourrait permettre :\n\n1. Une ex\u00e9cution de code arbitraire dans le contexte d\u2019IME et, par\n cons\u00e9quent, des modules bas\u00e9s dessus, tels que AMT ou PTT (Plateform\n Trust Technology) ;\n2. d\u2019impacter les m\u00e9canismes d\u2019attestation de validit\u00e9 de la machine,\n tel que la d\u00e9sactivation du Secure Boot, gr\u00e2ce \u00e0 la compromission\n d\u2019AMT ;\n3. de charger et ex\u00e9cuter du code arbitraire dans le contexte d\u2019AMT,\n par exemple pour charger une session VNC \u00e0 l\u2019insu du syst\u00e8me\n d\u2019exploitation ;\n4. de r\u00e9cup\u00e9rer des informations contenues dans la plateforme Intel\n PTT, telles que des cl\u00e9s de Bitlocker.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les microgiciels Intel",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Intel INTEL-SA-00086 du 20 novembre 2017",
"url": "https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00086\u0026languageid=en-fr"
}
]
}
CERTFR-2018-AVI-095
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans SCADA les produits Siemens . Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, une exécution de code arbitraire et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Title | Publication Time | Tags | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Se r\u00e9f\u00e9rer aux avis du constructeur pour les syst\u00e8mes affect\u00e9s (cf. section Documentation)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2017-5705",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-5705"
},
{
"name": "CVE-2017-5708",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-5708"
},
{
"name": "CVE-2017-5710",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-5710"
},
{
"name": "CVE-2017-5754",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-5754"
},
{
"name": "CVE-2017-5706",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-5706"
},
{
"name": "CVE-2017-5753",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-5753"
},
{
"name": "CVE-2017-5712",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-5712"
},
{
"name": "CVE-2017-5707",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-5707"
},
{
"name": "CVE-2017-5715",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-5715"
},
{
"name": "CVE-2017-15361",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-15361"
},
{
"name": "CVE-2017-5709",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-5709"
},
{
"name": "CVE-2017-5711",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-5711"
}
],
"initial_release_date": "2018-02-22T00:00:00",
"last_revision_date": "2018-02-22T00:00:00",
"links": [],
"reference": "CERTFR-2018-AVI-095",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2018-02-22T00:00:00.000000"
}
],
"risks": [
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Ex\u00e9cution de code arbitraire"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans SCADA les produits\nSiemens . Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, une ex\u00e9cution de code\narbitraire et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans SCADA les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 SCADA Siemens ssa-470231 du 22 f\u00e9vrier 2018",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-470231.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 SCADA Siemens ssa-168644 du 22 f\u00e9vrier 2018",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-168644.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 SCADA Siemens ssa-892715 du 22 f\u00e9vrier 2018",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892715.pdf"
}
]
}
var-201711-0645
Vulnerability from variot
Multiple buffer overflows in kernel in Intel Server Platform Services Firmware 4.0 allow attacker with local access to the system to execute arbitrary code. Multiple Oracle Server products are prone to multiple local security vulnerabilities. These vulnerabilities affect the following supported versions: 1.0 and 1.0.1. Intel Xeon Processor E3-1200 and others are CPUs (Central Processing Units) of Intel Corporation. The program supports remote access and management of servers. The following products are affected: 6th, 7th, and 8th Generation Intel Core Processor Family; Intel Xeon Processor E3-1200 v5 and v6 Product Family; Intel Xeon Processor Scalable Family; Intel Xeon Processor W Family; Intel Atom C3000 Processor Family; Apollo Lake Intel Atom Processor E3900 series; Apollo Lake Intel Pentium; Celeron N and J series Processors. -----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256
Note: the current version of the following document is available here: https://h20564.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-hpesbhf03798en_us
SUPPORT COMMUNICATION - SECURITY BULLETIN
Document ID: hpesbhf03798en_us Version: 1
HPESBHF03798 rev.1 - HPE Proliant Gen10 Servers, DL20 Gen9, ML30 Gen9 and Certain Apollo Servers Using Intel Server Platform Service (SPS) v4.0, Local Denial of Service and Execution of Arbitrary Code
NOTICE: The information in this Security Bulletin should be acted upon as soon as possible.
Release Date: 2017-11-21 Last Updated: 2017-11-21
Potential Security Impact: Local: Denial of Service (DoS), Execution of Arbitrary Code
Source: Hewlett Packard Enterprise, Product Security Response Team
VULNERABILITY SUMMARY A vulnerability in HPE certain Gen10 Servers, DL20 Gen9, ML30 Gen9 and certain Apollo servers with Intel Server Platform Service (SPS) v4.0 are vulnerable to local Denial of Service and execution of arbitrary code.
Note: Intel has identified security vulnerabilities which could potentially place impacted platforms at risk. The SPS/ME firmware used in Intels architecture can be compromised with physical access such that non-authenticated code may be executed in the SPS environment outside of the visibility of the user and operating system administrator.
- HPE Apollo 2000 System ROM firmware prior to v1.26
- HPE Apollo 4510 System ROM firmware prior to v1.26
- HPE Apollo 6000 DLC System ROM firmware prior to v1.26
- HPE ProLiant BL460c Gen10 Server Blade ROM firmware prior to v1.26
- HPE ProLiant DL20 Gen9 Server SPS Firmware prior to v4.01.04.054
- HPE ProLiant DL360 Gen10 Server ROM firmware prior to v1.26
- HPE ProLiant DL380 Gen10 Server ROM firmware prior to v1.26
- HPE ProLiant DL560 Gen10 Server ROM firmware prior to v1.26
- HPE ProLiant DL580 Gen10 Server ROM firmware prior to v1.26
- HPE ProLiant m710x Server Cartridge ROM firmware prior to v1.26
- HPE ProLiant ML30 Gen9 Server SPS Firmware prior to 4.01.04.054
- HPE ProLiant ML110 Gen10 Server ROM firmware prior to v1.26
- HPE ProLiant ML350 Gen10 Server ROM firmware prior to v1.26
- HPE ProLiant XL170r Gen10 Server ROM firmware prior to v1.26
- HPE ProLiant XL190r Gen10 Server ROM firmware prior to v1.26
- HPE ProLiant XL230k Gen10 Server ROM firmware prior to v1.26
- HPE ProLiant XL450 Gen10 Server ROM firmware prior to v1.26
- HPE Synergy 660 Gen10 Compute Module ROM firmware prior to v1.26, SPS firmware prior to 04.00.04.28
- HPE Synergy 480 Gen10 Compute Module ROM firmware prior to v1.26, SPS firmware prior to 04.00.04.28
BACKGROUND
CVSS Base Metrics ================= Reference, CVSS V3 Score/Vector, CVSS V2 Score/Vector
CVE-2017-5706
7.4 CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
7.2 (AV:L/AC:L/Au:N/C:C/I:C/A:C)
CVE-2017-5709
7.4 CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:N
5.6 (AV:L/AC:H/Au:N/C:C/I:C/A:N)
Information on CVSS is documented in
HPE Customer Notice HPSN-2008-002 here:
https://h20564.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-c01345499
RESOLUTION
HPE has provided the following response to resolve the vulnerabilities in SPS. HPE is working closely with Intel to ensure timely resolution of this issue on HPE systems. HPE will resolve this vulnerability in our servers in the following ways.
-
For customers that currently have impacted HPE ProLiant and Synergy servers at their locations, are available for download from HPEs support site. Customers should refer to the Customer Bulletin HPE Servers:
HISTORY Version:1 (rev.1) - 21 November 2017 Initial release
Third Party Security Patches: Third party security patches that are to be installed on systems running Hewlett Packard Enterprise (HPE) software products should be applied in accordance with the customer's patch management policy.
Support: For issues about implementing the recommendations of this Security Bulletin, contact normal HPE Services support channel. For other issues about the content of this Security Bulletin, send e-mail to security-alert@hpe.com.
Report: To report a potential security vulnerability for any HPE supported product: Web form: https://www.hpe.com/info/report-security-vulnerability Email: security-alert@hpe.com
Subscribe: To initiate a subscription to receive future HPE Security Bulletin alerts via Email: http://www.hpe.com/support/Subscriber_Choice
Security Bulletin Archive: A list of recently released Security Bulletins is available here: http://www.hpe.com/support/Security_Bulletin_Archive
Software Product Category: The Software Product Category is represented in the title by the two characters following HPSB.
3C = 3COM 3P = 3rd Party Software GN = HPE General Software HF = HPE Hardware and Firmware MU = Multi-Platform Software NS = NonStop Servers OV = OpenVMS PV = ProCurve ST = Storage Software UX = HP-UX
Copyright 2016 Hewlett Packard Enterprise
Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither HP or its affiliates, subcontractors or suppliers will be liable for incidental,special or consequential damages including downtime cost; lost profits; damages relating to the procurement of substitute products or services; or damages for loss of data, or software restoration. The information in this document is subject to change without notice. Hewlett Packard Enterprise and the names of Hewlett Packard Enterprise products referenced herein are trademarks of Hewlett Packard Enterprise in the United States and other countries. Other product and company names mentioned herein may be trademarks of their respective owners. -----BEGIN PGP SIGNATURE----- Version: GnuPG v1
iQEcBAEBCAAGBQJaFEmSAAoJELXhAxt7SZaiDlYH+gOhwTGNWGwKgHM443u5FL7l lq4v46iIYbFDRVPt6Ffh+I1YdjvclJ/EsQsJQiCdRqdBwUVCm31aBsRPD/Xk+fbn rrSLw7b2Eqyxy+F1Xe5Uoxwy7sOg1mROL7oQmst19cuWUgH8XX899+UQ/At2ikiM PoZDIthRb2KjnvyG0uLCkomWBKGxsnBCkDWd8tXw9AmsYmAPXlPPTcHZHxeDyGpm A/z214HFWRDg/xUf36VHQ2vp5Bung4auFMnwYdVFYciQZAJHzB1rALkVIXDqdNIL R243Vf6tGN2vQzqxr5enb0Mi9TCvQ2uDMPPpzObfDKhnYVVIwOPvbshlDuCFD4E= =4PaY -----END PGP SIGNATURE-----
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201711-0645",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "server platform services",
"scope": "eq",
"trust": 3.3,
"vendor": "intel",
"version": "4.0"
},
{
"model": "advanced server",
"scope": "eq",
"trust": 0.8,
"vendor": "hitachi",
"version": "ha8000 series"
},
{
"model": "advanced server",
"scope": "eq",
"trust": 0.8,
"vendor": "hitachi",
"version": "ha8000v series"
},
{
"model": "server",
"scope": "eq",
"trust": 0.3,
"vendor": "oracle",
"version": "x7-81.0.1"
},
{
"model": "server",
"scope": "eq",
"trust": 0.3,
"vendor": "oracle",
"version": "x7-81.0"
},
{
"model": "server x7-2l",
"scope": "eq",
"trust": 0.3,
"vendor": "oracle",
"version": "1.0.1"
},
{
"model": "server x7-2l",
"scope": "eq",
"trust": 0.3,
"vendor": "oracle",
"version": "1.0"
},
{
"model": "server",
"scope": "eq",
"trust": 0.3,
"vendor": "oracle",
"version": "x7-21.0.1"
},
{
"model": "server",
"scope": "eq",
"trust": 0.3,
"vendor": "oracle",
"version": "x7-21.0"
},
{
"model": "server platform services",
"scope": "ne",
"trust": 0.3,
"vendor": "intel",
"version": "4.0.04.139"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "server platform services",
"version": "4.0"
}
],
"sources": [
{
"db": "IVD",
"id": "e2dff632-39ab-11e9-9077-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2017-37803"
},
{
"db": "BID",
"id": "101906"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-010520"
},
{
"db": "CNNVD",
"id": "CNNVD-201711-886"
},
{
"db": "NVD",
"id": "CVE-2017-5706"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:intel:server_platform_services_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:hitachi:advanced_server",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-010520"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The vendor reported this issue.",
"sources": [
{
"db": "BID",
"id": "101906"
}
],
"trust": 0.3
},
"cve": "CVE-2017-5706",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "CVE-2017-5706",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.9,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "CNVD-2017-37803",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "e2dff632-39ab-11e9-9077-000c29342cb1",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "VHN-113909",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:L/AC:L/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2017-5706",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2017-5706",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2017-5706",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2017-37803",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201711-886",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "e2dff632-39ab-11e9-9077-000c29342cb1",
"trust": 0.2,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-113909",
"trust": 0.1,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2017-5706",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "e2dff632-39ab-11e9-9077-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2017-37803"
},
{
"db": "VULHUB",
"id": "VHN-113909"
},
{
"db": "VULMON",
"id": "CVE-2017-5706"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-010520"
},
{
"db": "CNNVD",
"id": "CNNVD-201711-886"
},
{
"db": "NVD",
"id": "CVE-2017-5706"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Multiple buffer overflows in kernel in Intel Server Platform Services Firmware 4.0 allow attacker with local access to the system to execute arbitrary code. Multiple Oracle Server products are prone to multiple local security vulnerabilities. \nThese vulnerabilities affect the following supported versions:\n1.0 and 1.0.1. Intel Xeon Processor E3-1200 and others are CPUs (Central Processing Units) of Intel Corporation. The program supports remote access and management of servers. The following products are affected: 6th, 7th, and 8th Generation Intel Core Processor Family; Intel Xeon Processor E3-1200 v5 and v6 Product Family; Intel Xeon Processor Scalable Family; Intel Xeon Processor W Family; Intel Atom C3000 Processor Family; Apollo Lake Intel Atom Processor E3900 series; Apollo Lake Intel Pentium; Celeron N and J series Processors. -----BEGIN PGP SIGNED MESSAGE-----\nHash: SHA256\n\nNote: the current version of the following document is available here:\nhttps://h20564.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-hpesbhf03798en_us\n\nSUPPORT COMMUNICATION - SECURITY BULLETIN\n\nDocument ID: hpesbhf03798en_us\nVersion: 1\n\nHPESBHF03798 rev.1 - HPE Proliant Gen10 Servers, DL20 Gen9, ML30 Gen9 and\nCertain Apollo Servers Using Intel Server Platform Service (SPS) v4.0, Local\nDenial of Service and Execution of Arbitrary Code\n\nNOTICE: The information in this Security Bulletin should be acted upon as\nsoon as possible. \n\nRelease Date: 2017-11-21\nLast Updated: 2017-11-21\n\nPotential Security Impact: Local: Denial of Service (DoS), Execution of\nArbitrary Code\n\nSource: Hewlett Packard Enterprise, Product Security Response Team\n\nVULNERABILITY SUMMARY\nA vulnerability in HPE certain Gen10 Servers, DL20 Gen9, ML30 Gen9 and\ncertain Apollo servers with Intel Server Platform Service (SPS) v4.0 are\nvulnerable to local Denial of Service and execution of arbitrary code. \n\n**Note:** Intel has identified security vulnerabilities which could\npotentially place impacted platforms at risk. The SPS/ME firmware\nused in Intels architecture can be compromised with physical access such\nthat non-authenticated code may be executed in the SPS environment outside of\nthe visibility of the user and operating system administrator. \n\n - HPE Apollo 2000 System ROM firmware prior to v1.26\n - HPE Apollo 4510 System ROM firmware prior to v1.26\n - HPE Apollo 6000 DLC System ROM firmware prior to v1.26\n - HPE ProLiant BL460c Gen10 Server Blade ROM firmware prior to v1.26\n - HPE ProLiant DL20 Gen9 Server SPS Firmware prior to v4.01.04.054\n - HPE ProLiant DL360 Gen10 Server ROM firmware prior to v1.26\n - HPE ProLiant DL380 Gen10 Server ROM firmware prior to v1.26\n - HPE ProLiant DL560 Gen10 Server ROM firmware prior to v1.26\n - HPE ProLiant DL580 Gen10 Server ROM firmware prior to v1.26\n - HPE ProLiant m710x Server Cartridge ROM firmware prior to v1.26\n - HPE ProLiant ML30 Gen9 Server SPS Firmware prior to 4.01.04.054\n - HPE ProLiant ML110 Gen10 Server ROM firmware prior to v1.26\n - HPE ProLiant ML350 Gen10 Server ROM firmware prior to v1.26\n - HPE ProLiant XL170r Gen10 Server ROM firmware prior to v1.26\n - HPE ProLiant XL190r Gen10 Server ROM firmware prior to v1.26\n - HPE ProLiant XL230k Gen10 Server ROM firmware prior to v1.26\n - HPE ProLiant XL450 Gen10 Server ROM firmware prior to v1.26\n - HPE Synergy 660 Gen10 Compute Module ROM firmware prior to v1.26, SPS\nfirmware prior to 04.00.04.28\n - HPE Synergy 480 Gen10 Compute Module ROM firmware prior to v1.26, SPS\nfirmware prior to 04.00.04.28\n\nBACKGROUND\n\n CVSS Base Metrics\n =================\n Reference, CVSS V3 Score/Vector, CVSS V2 Score/Vector\n\n CVE-2017-5706\n 7.4 CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\n 7.2 (AV:L/AC:L/Au:N/C:C/I:C/A:C)\n\n CVE-2017-5709\n 7.4 CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:N\n 5.6 (AV:L/AC:H/Au:N/C:C/I:C/A:N)\n\n Information on CVSS is documented in\n HPE Customer Notice HPSN-2008-002 here:\n\nhttps://h20564.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-c01345499\n\nRESOLUTION\n\nHPE has provided the following response to resolve the vulnerabilities in\nSPS. HPE is working closely with Intel to ensure timely resolution of this\nissue on HPE systems. HPE will resolve this vulnerability in our servers in\nthe following ways. \n\n* For customers that currently have impacted HPE ProLiant and Synergy servers\nat their locations, are available for download from HPEs support site. \nCustomers should refer to the Customer Bulletin HPE Servers:\n \n * [Some Systems Using Certain Intel Processors Are Vulnerable to Local\nDenial of Service and Execution of Arbitrary Code for detailed\ninstructions](https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a0\n036596en_us)\n\nHISTORY\nVersion:1 (rev.1) - 21 November 2017 Initial release\n\nThird Party Security Patches: Third party security patches that are to be\ninstalled on systems running Hewlett Packard Enterprise (HPE) software\nproducts should be applied in accordance with the customer\u0027s patch management\npolicy. \n\nSupport: For issues about implementing the recommendations of this Security\nBulletin, contact normal HPE Services support channel. For other issues about\nthe content of this Security Bulletin, send e-mail to security-alert@hpe.com. \n\nReport: To report a potential security vulnerability for any HPE supported\nproduct:\n Web form: https://www.hpe.com/info/report-security-vulnerability\n Email: security-alert@hpe.com\n\nSubscribe: To initiate a subscription to receive future HPE Security Bulletin\nalerts via Email: http://www.hpe.com/support/Subscriber_Choice\n\nSecurity Bulletin Archive: A list of recently released Security Bulletins is\navailable here: http://www.hpe.com/support/Security_Bulletin_Archive\n\nSoftware Product Category: The Software Product Category is represented in\nthe title by the two characters following HPSB. \n\n3C = 3COM\n3P = 3rd Party Software\nGN = HPE General Software\nHF = HPE Hardware and Firmware\nMU = Multi-Platform Software\nNS = NonStop Servers\nOV = OpenVMS\nPV = ProCurve\nST = Storage Software\nUX = HP-UX\n\nCopyright 2016 Hewlett Packard Enterprise\n\nHewlett Packard Enterprise shall not be liable for technical or editorial\nerrors or omissions contained herein. The information provided is provided\n\"as is\" without warranty of any kind. To the extent permitted by law, neither\nHP or its affiliates, subcontractors or suppliers will be liable for\nincidental,special or consequential damages including downtime cost; lost\nprofits; damages relating to the procurement of substitute products or\nservices; or damages for loss of data, or software restoration. The\ninformation in this document is subject to change without notice. Hewlett\nPackard Enterprise and the names of Hewlett Packard Enterprise products\nreferenced herein are trademarks of Hewlett Packard Enterprise in the United\nStates and other countries. Other product and company names mentioned herein\nmay be trademarks of their respective owners. \n-----BEGIN PGP SIGNATURE-----\nVersion: GnuPG v1\n\niQEcBAEBCAAGBQJaFEmSAAoJELXhAxt7SZaiDlYH+gOhwTGNWGwKgHM443u5FL7l\nlq4v46iIYbFDRVPt6Ffh+I1YdjvclJ/EsQsJQiCdRqdBwUVCm31aBsRPD/Xk+fbn\nrrSLw7b2Eqyxy+F1Xe5Uoxwy7sOg1mROL7oQmst19cuWUgH8XX899+UQ/At2ikiM\nPoZDIthRb2KjnvyG0uLCkomWBKGxsnBCkDWd8tXw9AmsYmAPXlPPTcHZHxeDyGpm\nA/z214HFWRDg/xUf36VHQ2vp5Bung4auFMnwYdVFYciQZAJHzB1rALkVIXDqdNIL\nR243Vf6tGN2vQzqxr5enb0Mi9TCvQ2uDMPPpzObfDKhnYVVIwOPvbshlDuCFD4E=\n=4PaY\n-----END PGP SIGNATURE-----\n",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-5706"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-010520"
},
{
"db": "CNVD",
"id": "CNVD-2017-37803"
},
{
"db": "BID",
"id": "101906"
},
{
"db": "IVD",
"id": "e2dff632-39ab-11e9-9077-000c29342cb1"
},
{
"db": "VULHUB",
"id": "VHN-113909"
},
{
"db": "VULMON",
"id": "CVE-2017-5706"
},
{
"db": "PACKETSTORM",
"id": "145070"
}
],
"trust": 2.88
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-5706",
"trust": 3.8
},
{
"db": "BID",
"id": "101906",
"trust": 1.5
},
{
"db": "SECTRACK",
"id": "1039955",
"trust": 1.2
},
{
"db": "SIEMENS",
"id": "SSA-892715",
"trust": 1.2
},
{
"db": "ICS CERT",
"id": "ICSA-18-060-01",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2017-37803",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201711-886",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2017-010520",
"trust": 0.8
},
{
"db": "IVD",
"id": "E2DFF632-39AB-11E9-9077-000C29342CB1",
"trust": 0.2
},
{
"db": "PACKETSTORM",
"id": "145070",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-113909",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2017-5706",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "e2dff632-39ab-11e9-9077-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2017-37803"
},
{
"db": "VULHUB",
"id": "VHN-113909"
},
{
"db": "VULMON",
"id": "CVE-2017-5706"
},
{
"db": "BID",
"id": "101906"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-010520"
},
{
"db": "PACKETSTORM",
"id": "145070"
},
{
"db": "CNNVD",
"id": "CNNVD-201711-886"
},
{
"db": "NVD",
"id": "CVE-2017-5706"
}
]
},
"id": "VAR-201711-0645",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "e2dff632-39ab-11e9-9077-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2017-37803"
},
{
"db": "VULHUB",
"id": "VHN-113909"
}
],
"trust": 0.09
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "e2dff632-39ab-11e9-9077-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2017-37803"
}
]
},
"last_update_date": "2024-11-23T21:53:34.226000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "INTEL-SA-00086",
"trust": 0.8,
"url": "https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00086\u0026languageid=en-fr"
},
{
"title": "NTAP-20171120-0001",
"trust": 0.8,
"url": "https://security.netapp.com/advisory/ntap-20171120-0001/"
},
{
"title": "Oracle Critical Patch Update Advisory - October 2017",
"trust": 0.8,
"url": "http://www.oracle.com/technetwork/security-advisory/cpuoct2017-3236626.html"
},
{
"title": "hitachi-sec-2017-201",
"trust": 0.8,
"url": "http://www.hitachi.co.jp/products/it/server/security/info/vulnerable/intel_sa00086.html"
},
{
"title": "Patch for Intel Server Platform Services Firmware Buffer Overflow Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/111389"
},
{
"title": "Multiple Intel product Server Platform Services Firmware Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=76618"
},
{
"title": "The Register",
"trust": 0.2,
"url": "https://www.theregister.co.uk/2017/12/06/intel_management_engine_pwned_by_buffer_overflow/"
},
{
"title": "Oracle: Oracle Critical Patch Update Advisory - October 2017",
"trust": 0.1,
"url": "https://vulmon.com/vendoradvisory?qidtp=oracle_advisories\u0026qid=523d3f220a64ff01dd95e064bd37566a"
},
{
"title": "SA86_check",
"trust": 0.1,
"url": "https://github.com/amarao/SA86_check "
},
{
"title": "Threatpost",
"trust": 0.1,
"url": "https://threatpost.com/undocumented-intel-visa-tech-can-be-abused-researchers-allege/143283/"
},
{
"title": "Threatpost",
"trust": 0.1,
"url": "https://threatpost.com/intel-patches-cpu-bugs-impacting-millions-of-pcs-servers/128962/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-37803"
},
{
"db": "VULMON",
"id": "CVE-2017-5706"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-010520"
},
{
"db": "CNNVD",
"id": "CNNVD-201711-886"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-113909"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-010520"
},
{
"db": "NVD",
"id": "CVE-2017-5706"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.6,
"url": "https://security-center.intel.com/advisory.aspx?intelid=intel-sa-00086\u0026languageid=en-fr"
},
{
"trust": 1.5,
"url": "http://www.oracle.com/technetwork/security-advisory/cpuoct2017-3236626.html"
},
{
"trust": 1.2,
"url": "http://www.securityfocus.com/bid/101906"
},
{
"trust": 1.2,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892715.pdf"
},
{
"trust": 1.2,
"url": "https://security.netapp.com/advisory/ntap-20171120-0001/"
},
{
"trust": 1.2,
"url": "https://www.asus.com/news/wzeltg5cjyaiwgj0"
},
{
"trust": 1.2,
"url": "https://twitter.com/ptsecurity_uk/status/938447926128291842"
},
{
"trust": 1.2,
"url": "http://www.securitytracker.com/id/1039955"
},
{
"trust": 1.1,
"url": "https://support.hpe.com/hpsc/doc/public/display?doclocale=en_us\u0026docid=emr_na-hpesbhf03798en_us"
},
{
"trust": 0.9,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-5706"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-5706"
},
{
"trust": 0.8,
"url": "https://www.us-cert.gov/ics/advisories/icsa-18-060-01"
},
{
"trust": 0.3,
"url": "http://www.oracle.com/index.html"
},
{
"trust": 0.1,
"url": "https://security-center.intel.com/advisory.aspx?intelid=intel-sa-00086\u0026amp;languageid=en-fr"
},
{
"trust": 0.1,
"url": "https://support.hpe.com/hpsc/doc/public/display?doclocale=en_us\u0026amp;docid=emr_na-hpesbhf03798en_us"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/119.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://www.theregister.co.uk/2017/12/06/intel_management_engine_pwned_by_buffer_overflow/"
},
{
"trust": 0.1,
"url": "https://threatpost.com/undocumented-intel-visa-tech-can-be-abused-researchers-allege/143283/"
},
{
"trust": 0.1,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-18-060-01"
},
{
"trust": 0.1,
"url": "https://h20564.www2.hpe.com/hpsc/doc/public/display?docid=emr_na-hpesbhf03798en_us"
},
{
"trust": 0.1,
"url": "http://www.hpe.com/support/security_bulletin_archive"
},
{
"trust": 0.1,
"url": "https://www.hpe.com/info/report-security-vulnerability"
},
{
"trust": 0.1,
"url": "https://h20564.www2.hpe.com/hpsc/doc/public/display?docid=emr_na-c01345499"
},
{
"trust": 0.1,
"url": "https://support.hpe.com/hpsc/doc/public/display?docid=emr_na-a0"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-5709"
},
{
"trust": 0.1,
"url": "http://www.hpe.com/support/subscriber_choice"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-37803"
},
{
"db": "VULHUB",
"id": "VHN-113909"
},
{
"db": "VULMON",
"id": "CVE-2017-5706"
},
{
"db": "BID",
"id": "101906"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-010520"
},
{
"db": "PACKETSTORM",
"id": "145070"
},
{
"db": "CNNVD",
"id": "CNNVD-201711-886"
},
{
"db": "NVD",
"id": "CVE-2017-5706"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "e2dff632-39ab-11e9-9077-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2017-37803"
},
{
"db": "VULHUB",
"id": "VHN-113909"
},
{
"db": "VULMON",
"id": "CVE-2017-5706"
},
{
"db": "BID",
"id": "101906"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-010520"
},
{
"db": "PACKETSTORM",
"id": "145070"
},
{
"db": "CNNVD",
"id": "CNNVD-201711-886"
},
{
"db": "NVD",
"id": "CVE-2017-5706"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-12-21T00:00:00",
"db": "IVD",
"id": "e2dff632-39ab-11e9-9077-000c29342cb1"
},
{
"date": "2017-12-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-37803"
},
{
"date": "2017-11-21T00:00:00",
"db": "VULHUB",
"id": "VHN-113909"
},
{
"date": "2017-11-21T00:00:00",
"db": "VULMON",
"id": "CVE-2017-5706"
},
{
"date": "2017-11-20T00:00:00",
"db": "BID",
"id": "101906"
},
{
"date": "2017-12-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-010520"
},
{
"date": "2017-11-22T15:27:23",
"db": "PACKETSTORM",
"id": "145070"
},
{
"date": "2017-11-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201711-886"
},
{
"date": "2017-11-21T14:29:00.323000",
"db": "NVD",
"id": "CVE-2017-5706"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-12-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-37803"
},
{
"date": "2018-05-11T00:00:00",
"db": "VULHUB",
"id": "VHN-113909"
},
{
"date": "2018-05-11T00:00:00",
"db": "VULMON",
"id": "CVE-2017-5706"
},
{
"date": "2017-12-19T22:00:00",
"db": "BID",
"id": "101906"
},
{
"date": "2019-07-10T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-010520"
},
{
"date": "2017-11-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201711-886"
},
{
"date": "2024-11-21T03:28:15.643000",
"db": "NVD",
"id": "CVE-2017-5706"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "BID",
"id": "101906"
},
{
"db": "PACKETSTORM",
"id": "145070"
},
{
"db": "CNNVD",
"id": "CNNVD-201711-886"
}
],
"trust": 1.0
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Intel Server Platform Services Firmware Buffer Overflow Vulnerability",
"sources": [
{
"db": "IVD",
"id": "e2dff632-39ab-11e9-9077-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2017-37803"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Buffer overflow",
"sources": [
{
"db": "IVD",
"id": "e2dff632-39ab-11e9-9077-000c29342cb1"
},
{
"db": "CNNVD",
"id": "CNNVD-201711-886"
}
],
"trust": 0.8
}
}
ghsa-55pw-cf45-3838
Vulnerability from github
Multiple buffer overflows in kernel in Intel Server Platform Services Firmware 4.0 allow attacker with local access to the system to execute arbitrary code.
{
"affected": [],
"aliases": [
"CVE-2017-5706"
],
"database_specific": {
"cwe_ids": [
"CWE-119"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2017-11-21T14:29:00Z",
"severity": "HIGH"
},
"details": "Multiple buffer overflows in kernel in Intel Server Platform Services Firmware 4.0 allow attacker with local access to the system to execute arbitrary code.",
"id": "GHSA-55pw-cf45-3838",
"modified": "2025-04-20T03:48:53Z",
"published": "2022-05-14T03:24:42Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2017-5706"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892715.pdf"
},
{
"type": "WEB",
"url": "https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00086\u0026languageid=en-fr"
},
{
"type": "WEB",
"url": "https://security.netapp.com/advisory/ntap-20171120-0001"
},
{
"type": "WEB",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03798en_us"
},
{
"type": "WEB",
"url": "https://twitter.com/PTsecurity_UK/status/938447926128291842"
},
{
"type": "WEB",
"url": "https://www.asus.com/News/wzeltG5CjYaIwGJ0"
},
{
"type": "WEB",
"url": "http://www.oracle.com/technetwork/security-advisory/cpuoct2017-3236626.html"
},
{
"type": "WEB",
"url": "http://www.securityfocus.com/bid/101906"
},
{
"type": "WEB",
"url": "http://www.securitytracker.com/id/1039955"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.