CVE-2017-12734 (GCVE-0-2017-12734)
Vulnerability from cvelistv5
- CWE-895 - SFP Primary Cluster: Information Leak
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | http://www.securityfocus.com/bid/100560 | Third Party Advisory, VDB Entry | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-087240.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/100560 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-087240.pdf | Patch, Vendor Advisory |
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens | LOGO! 8 BM (incl. SIPLUS variants) |
Version: All versions < V1.81.2 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T18:43:56.700Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "100560", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/100560" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-087240.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "LOGO! 8 BM (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.81.2" } ] } ], "datePublic": "2017-08-30T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions \u003c V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-895", "description": "CWE-895: SFP Primary Cluster: Information Leak", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-14T21:05:17", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "100560", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/100560" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-087240.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2017-12734", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "LOGO! 8 BM (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V1.81.2" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions \u003c V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-895: SFP Primary Cluster: Information Leak" } ] } ] }, "references": { "reference_data": [ { "name": "100560", "refsource": "BID", "url": "http://www.securityfocus.com/bid/100560" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-087240.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-087240.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2017-12734", "datePublished": "2017-08-30T19:00:00", "dateReserved": "2017-08-09T00:00:00", "dateUpdated": "2024-08-05T18:43:56.700Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2017-12734\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2017-08-30T19:29:00.273\",\"lastModified\":\"2025-04-20T01:37:25.860\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions \u003c V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en LOGO! 8 BM (incl. Variantes SIPLUS) (todas las versiones anteriores a V1.81.2). Un atacante con acceso de red al servidor web integrado en el puerto 80/tcp podr\u00eda obtener la ID de sesi\u00f3n de una sesi\u00f3n de usuario activa. Un usuario debe iniciar sesi\u00f3n en la interfaz web. Siemens recomienda utilizar el servidor web integrado en el puerto 80/tcp solo en redes de confianza.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-895\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:logo\\\\!8_bm_fs-05_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.81.1\",\"matchCriteriaId\":\"6128EB35-6031-4F61-8B25-596E6FE664A1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:logo\\\\!8_bm_fs-05:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"641F5F08-8D9F-425C-9735-DC174431EEA3\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/100560\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-087240.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/100560\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-087240.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}" } }
cnvd-2017-24122
Vulnerability from cnvd
Title: Siemens LOGO!8 BM会话ID泄露漏洞
Description:
LOGO!8是西门子第8代智能逻辑控制器,是西门子PLC家族里的Nano PLC,它简化了编程组态,集成的面板可显示更多的内容,并可通过集成的以太网接口轻松组网高效互联。
Siemens LOGO!8 BM存在漏洞,对端口80/tcp上的集成Web服务器进行网络访问的攻击者,可以通过诱使用户登录Web界面,从而获取活动用户会话的会话ID。
Severity: 高
Patch Name: Siemens LOGO!8 BM会话ID泄露漏洞的补丁
Patch Description:
LOGO!8是西门子第8代智能逻辑控制器,是西门子PLC家族里的Nano PLC,它简化了编程组态,集成的面板可显示更多的内容,并可通过集成的以太网接口轻松组网高效互联。
Siemens LOGO!8 BM存在漏洞,对端口80/tcp上的集成Web服务器进行网络访问的攻击者,可以通过诱使用户登录Web界面,从而获取活动用户会话的会话ID。目前,供应商发布了安全公告及相关补丁信息,修复了此漏洞。
Formal description:
用户可联系供应商获得补丁信息: https://www.siemens.com
Reference: https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-087240.pdf
Name | Siemens LOGO!8 BM <1.81.2 |
---|
{ "cves": { "cve": { "cveNumber": "CVE-2017-12734" } }, "description": "LOGO!8\u662f\u897f\u95e8\u5b50\u7b2c8\u4ee3\u667a\u80fd\u903b\u8f91\u63a7\u5236\u5668\uff0c\u662f\u897f\u95e8\u5b50PLC\u5bb6\u65cf\u91cc\u7684Nano PLC\uff0c\u5b83\u7b80\u5316\u4e86\u7f16\u7a0b\u7ec4\u6001\uff0c\u96c6\u6210\u7684\u9762\u677f\u53ef\u663e\u793a\u66f4\u591a\u7684\u5185\u5bb9\uff0c\u5e76\u53ef\u901a\u8fc7\u96c6\u6210\u7684\u4ee5\u592a\u7f51\u63a5\u53e3\u8f7b\u677e\u7ec4\u7f51\u9ad8\u6548\u4e92\u8054\u3002\r\n\r\nSiemens LOGO!8 BM\u5b58\u5728\u6f0f\u6d1e\uff0c\u5bf9\u7aef\u53e380/tcp\u4e0a\u7684\u96c6\u6210Web\u670d\u52a1\u5668\u8fdb\u884c\u7f51\u7edc\u8bbf\u95ee\u7684\u653b\u51fb\u8005\uff0c\u53ef\u4ee5\u901a\u8fc7\u8bf1\u4f7f\u7528\u6237\u767b\u5f55Web\u754c\u9762\uff0c\u4ece\u800c\u83b7\u53d6\u6d3b\u52a8\u7528\u6237\u4f1a\u8bdd\u7684\u4f1a\u8bddID\u3002", "discovererName": "Maxim Rupp", "formalWay": "\u7528\u6237\u53ef\u8054\u7cfb\u4f9b\u5e94\u5546\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttps://www.siemens.com", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2017-24122", "openTime": "2017-08-31", "patchDescription": "LOGO!8\u662f\u897f\u95e8\u5b50\u7b2c8\u4ee3\u667a\u80fd\u903b\u8f91\u63a7\u5236\u5668\uff0c\u662f\u897f\u95e8\u5b50PLC\u5bb6\u65cf\u91cc\u7684Nano PLC\uff0c\u5b83\u7b80\u5316\u4e86\u7f16\u7a0b\u7ec4\u6001\uff0c\u96c6\u6210\u7684\u9762\u677f\u53ef\u663e\u793a\u66f4\u591a\u7684\u5185\u5bb9\uff0c\u5e76\u53ef\u901a\u8fc7\u96c6\u6210\u7684\u4ee5\u592a\u7f51\u63a5\u53e3\u8f7b\u677e\u7ec4\u7f51\u9ad8\u6548\u4e92\u8054\u3002\r\n\r\nSiemens LOGO!8 BM\u5b58\u5728\u6f0f\u6d1e\uff0c\u5bf9\u7aef\u53e380/tcp\u4e0a\u7684\u96c6\u6210Web\u670d\u52a1\u5668\u8fdb\u884c\u7f51\u7edc\u8bbf\u95ee\u7684\u653b\u51fb\u8005\uff0c\u53ef\u4ee5\u901a\u8fc7\u8bf1\u4f7f\u7528\u6237\u767b\u5f55Web\u754c\u9762\uff0c\u4ece\u800c\u83b7\u53d6\u6d3b\u52a8\u7528\u6237\u4f1a\u8bdd\u7684\u4f1a\u8bddID\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002", "patchName": "Siemens LOGO!8 BM\u4f1a\u8bddID\u6cc4\u9732\u6f0f\u6d1e\u7684\u8865\u4e01", "products": { "product": "Siemens LOGO!8 BM \u003c1.81.2" }, "referenceLink": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-087240.pdf", "serverity": "\u9ad8", "submitTime": "2017-08-31", "title": "Siemens LOGO!8 BM\u4f1a\u8bddID\u6cc4\u9732\u6f0f\u6d1e" }
ICSA-17-243-02
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." }, { "names": [ "Maxim Rupp" ], "summary": "for coordinating disclosure of CVE-2017-12734" }, { "names": [ "Artem Zinenko" ], "organization": "Kaspersky", "summary": "for pointing out that SIPLUS should also be mentioned" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.", "title": "General Recommendations" }, { "category": "general", "text": "Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from a Siemens ProductCERT\u0027s advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-087240: Vulnerabilities in SIEMENS LOGO! - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-087240.html" }, { "category": "self", "summary": "ICS Advisory ICSA-17-243-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2017/icsa-17-243-02.json" }, { "category": "self", "summary": "ICS Advisory ICSA-17-243-02 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-243-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens LOGO! (Update A)", "tracking": { "current_release_date": "2020-12-08T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-17-243-02", "initial_release_date": "2017-08-30T00:00:00.000000Z", "revision_history": [ { "date": "2017-08-30T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2020-02-10T00:00:00.000000Z", "legacy_version": "1.1", "number": "2", "summary": "SIPLUS devices now explicitly mentioned in the list of affected products" }, { "date": "2020-12-08T00:00:00.000000Z", "legacy_version": "1.2", "number": "3", "summary": "Add solution for CVE-2017-12735." } ], "status": "final", "version": "3" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV1.81.2", "product": { "name": "Siemens LOGO! 8 BM (incl.\u0027SIPLUS variants): All versions \u003c V1.81.2", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "LOGO! 8 BM (incl.\u0027SIPLUS variants)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.3", "product": { "name": "Siemens LOGO! 8 BM (incl.\u0027SIPLUS variants): All versions \u003c V8.3", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "LOGO! 8 BM (incl.\u0027SIPLUS variants)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2017-12734", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "summary", "text": "An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Siemens provides LOGO!8 BM FS-05 with firmware version V1.81.2, which fixes CVE-2017-12734", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Configure the environment according to the recommendations in the user manual (see https://support.industry.siemens.com/cs/us/en/view/109741041)", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Apply cell protection concept (see https://www.siemens.com/cert/operational-guidelines-industrial-security)", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Use VPN for protecting network communication between cells", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Apply Defense-in-Depth (see http://www.industry.siemens.com/topics/global/en/industrial-security/concept/Pages/defense-in-depth.aspx)", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2017-12734" }, { "cve": "CVE-2017-12735", "cwe": { "id": "CWE-300", "name": "Channel Accessible by Non-Endpoint" }, "notes": [ { "category": "summary", "text": "An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "remediations": [ { "category": "mitigation", "details": "Configure the environment according to the recommendations in the user manual (see https://support.industry.siemens.com/cs/us/en/view/109741041)", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Apply cell protection concept (see https://www.siemens.com/cert/operational-guidelines-industrial-security)", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Use VPN for protecting network communication between cells", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Apply Defense-in-Depth (see http://www.industry.siemens.com/topics/global/en/industrial-security/concept/Pages/defense-in-depth.aspx)", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V8.3. Notice that in order to update, a new hardware version is required. https://support.industry.siemens.com/cs/ww/en/view/109783346/", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.4, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2017-12735" } ] }
icsa-17-243-02
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." }, { "names": [ "Maxim Rupp" ], "summary": "for coordinating disclosure of CVE-2017-12734" }, { "names": [ "Artem Zinenko" ], "organization": "Kaspersky", "summary": "for pointing out that SIPLUS should also be mentioned" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.", "title": "General Recommendations" }, { "category": "general", "text": "Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from a Siemens ProductCERT\u0027s advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-087240: Vulnerabilities in SIEMENS LOGO! - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-087240.html" }, { "category": "self", "summary": "ICS Advisory ICSA-17-243-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2017/icsa-17-243-02.json" }, { "category": "self", "summary": "ICS Advisory ICSA-17-243-02 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-243-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens LOGO! (Update A)", "tracking": { "current_release_date": "2020-12-08T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-17-243-02", "initial_release_date": "2017-08-30T00:00:00.000000Z", "revision_history": [ { "date": "2017-08-30T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2020-02-10T00:00:00.000000Z", "legacy_version": "1.1", "number": "2", "summary": "SIPLUS devices now explicitly mentioned in the list of affected products" }, { "date": "2020-12-08T00:00:00.000000Z", "legacy_version": "1.2", "number": "3", "summary": "Add solution for CVE-2017-12735." } ], "status": "final", "version": "3" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV1.81.2", "product": { "name": "Siemens LOGO! 8 BM (incl.\u0027SIPLUS variants): All versions \u003c V1.81.2", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "LOGO! 8 BM (incl.\u0027SIPLUS variants)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.3", "product": { "name": "Siemens LOGO! 8 BM (incl.\u0027SIPLUS variants): All versions \u003c V8.3", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "LOGO! 8 BM (incl.\u0027SIPLUS variants)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2017-12734", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "summary", "text": "An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "vendor_fix", "details": "Siemens provides LOGO!8 BM FS-05 with firmware version V1.81.2, which fixes CVE-2017-12734", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Configure the environment according to the recommendations in the user manual (see https://support.industry.siemens.com/cs/us/en/view/109741041)", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Apply cell protection concept (see https://www.siemens.com/cert/operational-guidelines-industrial-security)", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Use VPN for protecting network communication between cells", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Apply Defense-in-Depth (see http://www.industry.siemens.com/topics/global/en/industrial-security/concept/Pages/defense-in-depth.aspx)", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2017-12734" }, { "cve": "CVE-2017-12735", "cwe": { "id": "CWE-300", "name": "Channel Accessible by Non-Endpoint" }, "notes": [ { "category": "summary", "text": "An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002" ] }, "remediations": [ { "category": "mitigation", "details": "Configure the environment according to the recommendations in the user manual (see https://support.industry.siemens.com/cs/us/en/view/109741041)", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Apply cell protection concept (see https://www.siemens.com/cert/operational-guidelines-industrial-security)", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Use VPN for protecting network communication between cells", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Apply Defense-in-Depth (see http://www.industry.siemens.com/topics/global/en/industrial-security/concept/Pages/defense-in-depth.aspx)", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V8.3. Notice that in order to update, a new hardware version is required. https://support.industry.siemens.com/cs/ww/en/view/109783346/", "product_ids": [ "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.4, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002" ] } ], "title": "CVE-2017-12735" } ] }
fkie_cve-2017-12734
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | http://www.securityfocus.com/bid/100560 | Third Party Advisory, VDB Entry | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-087240.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/100560 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-087240.pdf | Patch, Vendor Advisory |
Vendor | Product | Version | |
---|---|---|---|
siemens | logo\!8_bm_fs-05_firmware | * | |
siemens | logo\!8_bm_fs-05 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:logo\\!8_bm_fs-05_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6128EB35-6031-4F61-8B25-596E6FE664A1", "versionEndIncluding": "1.81.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:logo\\!8_bm_fs-05:-:*:*:*:*:*:*:*", "matchCriteriaId": "641F5F08-8D9F-425C-9735-DC174431EEA3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions \u003c V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en LOGO! 8 BM (incl. Variantes SIPLUS) (todas las versiones anteriores a V1.81.2). Un atacante con acceso de red al servidor web integrado en el puerto 80/tcp podr\u00eda obtener la ID de sesi\u00f3n de una sesi\u00f3n de usuario activa. Un usuario debe iniciar sesi\u00f3n en la interfaz web. Siemens recomienda utilizar el servidor web integrado en el puerto 80/tcp solo en redes de confianza." } ], "id": "CVE-2017-12734", "lastModified": "2025-04-20T01:37:25.860", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2017-08-30T19:29:00.273", "references": [ { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/100560" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-087240.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/100560" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-087240.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Deferred", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-895" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
var-201708-1136
Vulnerability from variot
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks. Siemens LOGO! The device contains an information disclosure vulnerability.Information may be obtained. LOGO!8 is the 8th generation intelligent logic controller of Siemens. It is the NanoPLC in the Siemens PLC family. It simplifies the programming configuration, the integrated panel can display more content, and can be easily integrated efficiently through the integrated Ethernet interface. interconnected. There is a vulnerability in SiemensLOGO!8BM. An attacker can exploit this issue to obtain sensitive information. Successful exploits may lead to other attacks. Versions prior to LOGO!8 BM FS-05 1.81.2 are vulnerable
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201708-1136", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "logo\\!8 bm fs-05", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "1.81.1" }, { "model": "logo!8 bm fs-05", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "1.81.2" }, { "model": "logo!8 bm", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "1.81.2" }, { "model": "logo\\!8 bm fs-05", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1.81.1" }, { "model": "logo!8 bm fs-05", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "logo!8 bm fs-05", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "1.81.2" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "logo 8 bm fs 05", "version": "*" } ], "sources": [ { "db": "IVD", "id": "8d7fabcf-0e35-4716-a6e6-04e8b861bfd7" }, { "db": "CNVD", "id": "CNVD-2017-24122" }, { "db": "BID", "id": "100560" }, { "db": "JVNDB", "id": "JVNDB-2017-008020" }, { "db": "CNNVD", "id": "CNNVD-201708-1272" }, { "db": "NVD", "id": "CVE-2017-12734" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:siemens:logo%218_bm_fs-05_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-008020" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Maxim Rupp", "sources": [ { "db": "BID", "id": "100560" } ], "trust": 0.3 }, "cve": "CVE-2017-12734", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2017-12734", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 7.8, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2017-24122", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "NONE", "baseScore": 7.8, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "8d7fabcf-0e35-4716-a6e6-04e8b861bfd7", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "VHN-103286", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2017-12734", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2017-12734", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2017-12734", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2017-12734", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2017-24122", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201708-1272", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "8d7fabcf-0e35-4716-a6e6-04e8b861bfd7", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-103286", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "8d7fabcf-0e35-4716-a6e6-04e8b861bfd7" }, { "db": "CNVD", "id": "CNVD-2017-24122" }, { "db": "VULHUB", "id": "VHN-103286" }, { "db": "JVNDB", "id": "JVNDB-2017-008020" }, { "db": "CNNVD", "id": "CNNVD-201708-1272" }, { "db": "NVD", "id": "CVE-2017-12734" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions \u003c V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks. Siemens LOGO! The device contains an information disclosure vulnerability.Information may be obtained. LOGO!8 is the 8th generation intelligent logic controller of Siemens. It is the NanoPLC in the Siemens PLC family. It simplifies the programming configuration, the integrated panel can display more content, and can be easily integrated efficiently through the integrated Ethernet interface. interconnected. There is a vulnerability in SiemensLOGO!8BM. \nAn attacker can exploit this issue to obtain sensitive information. Successful exploits may lead to other attacks. \nVersions prior to LOGO!8 BM FS-05 1.81.2 are vulnerable", "sources": [ { "db": "NVD", "id": "CVE-2017-12734" }, { "db": "JVNDB", "id": "JVNDB-2017-008020" }, { "db": "CNVD", "id": "CNVD-2017-24122" }, { "db": "BID", "id": "100560" }, { "db": "IVD", "id": "8d7fabcf-0e35-4716-a6e6-04e8b861bfd7" }, { "db": "VULHUB", "id": "VHN-103286" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2017-12734", "trust": 3.6 }, { "db": "SIEMENS", "id": "SSA-087240", "trust": 2.6 }, { "db": "BID", "id": "100560", "trust": 2.0 }, { "db": "ICS CERT", "id": "ICSA-17-243-02", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-201708-1272", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2017-24122", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2017-008020", "trust": 0.8 }, { "db": "IVD", "id": "8D7FABCF-0E35-4716-A6E6-04E8B861BFD7", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-103286", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "8d7fabcf-0e35-4716-a6e6-04e8b861bfd7" }, { "db": "CNVD", "id": "CNVD-2017-24122" }, { "db": "VULHUB", "id": "VHN-103286" }, { "db": "BID", "id": "100560" }, { "db": "JVNDB", "id": "JVNDB-2017-008020" }, { "db": "CNNVD", "id": "CNNVD-201708-1272" }, { "db": "NVD", "id": "CVE-2017-12734" } ] }, "id": "VAR-201708-1136", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "8d7fabcf-0e35-4716-a6e6-04e8b861bfd7" }, { "db": "CNVD", "id": "CNVD-2017-24122" }, { "db": "VULHUB", "id": "VHN-103286" } ], "trust": 1.8285714 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS", "Network device" ], "sub_category": null, "trust": 0.6 }, { "category": [ "ICS" ], "sub_category": null, "trust": 0.2 } ], "sources": [ { "db": "IVD", "id": "8d7fabcf-0e35-4716-a6e6-04e8b861bfd7" }, { "db": "CNVD", "id": "CNVD-2017-24122" } ] }, "last_update_date": "2024-11-23T22:12:53.084000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-087240", "trust": 0.8, "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-087240.pdf" }, { "title": "SiemensLOGO! 8BM Session ID Disclosure Vulnerability Patch", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/101261" }, { "title": "Siemens LOGO!8 BM Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=74460" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2017-24122" }, { "db": "JVNDB", "id": "JVNDB-2017-008020" }, { "db": "CNNVD", "id": "CNNVD-201708-1272" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-200", "trust": 1.9 }, { "problemtype": "CWE-895", "trust": 1.0 } ], "sources": [ { "db": "VULHUB", "id": "VHN-103286" }, { "db": "JVNDB", "id": "JVNDB-2017-008020" }, { "db": "NVD", "id": "CVE-2017-12734" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "http://www.securityfocus.com/bid/100560" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-087240.pdf" }, { "trust": 1.5, "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-087240.pdf" }, { "trust": 1.1, "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-243-02" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-12734" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-12734" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-17-243-02" }, { "trust": 0.3, "url": "http://www.siemens.com/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2017-24122" }, { "db": "VULHUB", "id": "VHN-103286" }, { "db": "BID", "id": "100560" }, { "db": "JVNDB", "id": "JVNDB-2017-008020" }, { "db": "CNNVD", "id": "CNNVD-201708-1272" }, { "db": "NVD", "id": "CVE-2017-12734" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "8d7fabcf-0e35-4716-a6e6-04e8b861bfd7" }, { "db": "CNVD", "id": "CNVD-2017-24122" }, { "db": "VULHUB", "id": "VHN-103286" }, { "db": "BID", "id": "100560" }, { "db": "JVNDB", "id": "JVNDB-2017-008020" }, { "db": "CNNVD", "id": "CNNVD-201708-1272" }, { "db": "NVD", "id": "CVE-2017-12734" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2017-08-31T00:00:00", "db": "IVD", "id": "8d7fabcf-0e35-4716-a6e6-04e8b861bfd7" }, { "date": "2017-08-31T00:00:00", "db": "CNVD", "id": "CNVD-2017-24122" }, { "date": "2017-08-30T00:00:00", "db": "VULHUB", "id": "VHN-103286" }, { "date": "2017-08-30T00:00:00", "db": "BID", "id": "100560" }, { "date": "2017-10-05T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-008020" }, { "date": "2017-08-30T00:00:00", "db": "CNNVD", "id": "CNNVD-201708-1272" }, { "date": "2017-08-30T19:29:00.273000", "db": "NVD", "id": "CVE-2017-12734" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2017-08-31T00:00:00", "db": "CNVD", "id": "CNVD-2017-24122" }, { "date": "2019-10-09T00:00:00", "db": "VULHUB", "id": "VHN-103286" }, { "date": "2017-08-30T00:00:00", "db": "BID", "id": "100560" }, { "date": "2017-10-05T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-008020" }, { "date": "2020-12-15T00:00:00", "db": "CNNVD", "id": "CNNVD-201708-1272" }, { "date": "2024-11-21T03:10:07.130000", "db": "NVD", "id": "CVE-2017-12734" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201708-1272" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens LOGO! Information disclosure vulnerability in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-008020" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "information disclosure", "sources": [ { "db": "CNNVD", "id": "CNNVD-201708-1272" } ], "trust": 0.6 } }
ghsa-p45c-2j4h-j2xg
Vulnerability from github
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks.
{ "affected": [], "aliases": [ "CVE-2017-12734" ], "database_specific": { "cwe_ids": [ "CWE-200" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2017-08-30T19:29:00Z", "severity": "HIGH" }, "details": "A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions \u003c V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks.", "id": "GHSA-p45c-2j4h-j2xg", "modified": "2022-05-13T01:04:23Z", "published": "2022-05-13T01:04:23Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2017-12734" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-087240.pdf" }, { "type": "WEB", "url": "http://www.securityfocus.com/bid/100560" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "type": "CVSS_V3" } ] }
gsd-2017-12734
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2017-12734", "description": "A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions \u003c V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks.", "id": "GSD-2017-12734" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2017-12734" ], "details": "A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions \u003c V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks.", "id": "GSD-2017-12734", "modified": "2023-12-13T01:21:03.807210Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2017-12734", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "LOGO! 8 BM (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V1.81.2" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions \u003c V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-895: SFP Primary Cluster: Information Leak" } ] } ] }, "references": { "reference_data": [ { "name": "100560", "refsource": "BID", "url": "http://www.securityfocus.com/bid/100560" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-087240.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-087240.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:logo\\!8_bm_fs-05_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "1.81.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:logo\\!8_bm_fs-05:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2017-12734" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions \u003c V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-895" } ] } ] }, "references": { "reference_data": [ { "name": "100560", "refsource": "BID", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/100560" }, { "name": "N/A", "refsource": "CONFIRM", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-087240.pdf" } ] } }, "impact": { "baseMetricV2": { "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } }, "lastModifiedDate": "2022-01-04T18:09Z", "publishedDate": "2017-08-30T19:29Z" } } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.