cve-2016-7542
Vulnerability from cvelistv5
Published
2017-03-30 14:00
Modified
2024-10-25 14:35
Severity ?
EPSS score ?
Summary
A read-only administrator on Fortinet devices with FortiOS 5.2.x before 5.2.10 GA and 5.4.x before 5.4.2 GA may have access to read-write administrators password hashes (not including super-admins) stored on the appliance via the webui REST API, and may therefore be able to crack them.
References
▼ | URL | Tags | |
---|---|---|---|
psirt@fortinet.com | http://fortiguard.com/advisory/FG-IR-16-050 | Not Applicable | |
psirt@fortinet.com | http://www.securityfocus.com/bid/94690 | Third Party Advisory, VDB Entry | |
psirt@fortinet.com | http://www.securitytracker.com/id/1037394 | ||
af854a3a-2127-422b-91ae-364da2661108 | http://fortiguard.com/advisory/FG-IR-16-050 | Not Applicable | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/94690 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securitytracker.com/id/1037394 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T02:04:54.869Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "94690", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/94690" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://fortiguard.com/advisory/FG-IR-16-050" }, { "name": "1037394", "tags": [ "vdb-entry", "x_refsource_SECTRACK", "x_transferred" ], "url": "http://www.securitytracker.com/id/1037394" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2016-7542", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-10-23T14:00:57.607119Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-25T14:35:34.799Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "FortiOS", "vendor": "Fortinet", "versions": [ { "status": "affected", "version": "5.2.0 - 5.2.9, 5.4.1" } ] } ], "datePublic": "2016-12-02T00:00:00", "descriptions": [ { "lang": "en", "value": "A read-only administrator on Fortinet devices with FortiOS 5.2.x before 5.2.10 GA and 5.4.x before 5.4.2 GA may have access to read-write administrators password hashes (not including super-admins) stored on the appliance via the webui REST API, and may therefore be able to crack them." } ], "problemTypes": [ { "descriptions": [ { "description": "Information leak", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2017-07-27T09:57:01", "orgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8", "shortName": "fortinet" }, "references": [ { "name": "94690", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/94690" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://fortiguard.com/advisory/FG-IR-16-050" }, { "name": "1037394", "tags": [ "vdb-entry", "x_refsource_SECTRACK" ], "url": "http://www.securitytracker.com/id/1037394" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "psirt@fortinet.com", "ID": "CVE-2016-7542", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "FortiOS", "version": { "version_data": [ { "version_value": "5.2.0 - 5.2.9, 5.4.1" } ] } } ] }, "vendor_name": "Fortinet" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A read-only administrator on Fortinet devices with FortiOS 5.2.x before 5.2.10 GA and 5.4.x before 5.4.2 GA may have access to read-write administrators password hashes (not including super-admins) stored on the appliance via the webui REST API, and may therefore be able to crack them." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Information leak" } ] } ] }, "references": { "reference_data": [ { "name": "94690", "refsource": "BID", "url": "http://www.securityfocus.com/bid/94690" }, { "name": "http://fortiguard.com/advisory/FG-IR-16-050", "refsource": "CONFIRM", "url": "http://fortiguard.com/advisory/FG-IR-16-050" }, { "name": "1037394", "refsource": "SECTRACK", "url": "http://www.securitytracker.com/id/1037394" } ] } } } }, "cveMetadata": { "assignerOrgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8", "assignerShortName": "fortinet", "cveId": "CVE-2016-7542", "datePublished": "2017-03-30T14:00:00", "dateReserved": "2016-09-09T00:00:00", "dateUpdated": "2024-10-25T14:35:34.799Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2016-7542\",\"sourceIdentifier\":\"psirt@fortinet.com\",\"published\":\"2017-03-30T14:59:00.197\",\"lastModified\":\"2024-11-21T02:58:10.920\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A read-only administrator on Fortinet devices with FortiOS 5.2.x before 5.2.10 GA and 5.4.x before 5.4.2 GA may have access to read-write administrators password hashes (not including super-admins) stored on the appliance via the webui REST API, and may therefore be able to crack them.\"},{\"lang\":\"es\",\"value\":\"Un administrador de s\u00f3lo lectura en dispositivos Fortinet con FortiOS 5.2.x en versiones anteriores a 5.2.10 GA y FortiOS 5.4.x en versiones anteriores a 5.4.2 GA puede tener acceso de lectura-escritura a hashes de contrase\u00f1as de administradores (no incluyendo super-admins), almacenados en el dispositivo a trav\u00e9s de la API Rest webui, y puede por lo tanto ser capaz de romperlo.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":4.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.2,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:N/A:N\",\"baseScore\":4.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fortinet:fortios:5.2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7E627C59-7C16-44F0-800D-A2E8A766B26D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fortinet:fortios:5.2.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"233236FA-BB13-4261-BE2E-3E617406DC53\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fortinet:fortios:5.2.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"27844CC9-498B-4A65-91AC-AC130222EE5F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fortinet:fortios:5.2.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"27B4C672-7ED5-4113-87AE-5774D1263C0B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fortinet:fortios:5.2.4:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2CBEA3AA-AE46-4A55-91EE-9ADC187BF614\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fortinet:fortios:5.2.5:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"05CB7A90-91BC-49AF-9B5C-EBD212484C64\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fortinet:fortios:5.2.6:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"864D3221-177B-43CE-BD7D-CB14A110268E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fortinet:fortios:5.2.7:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"31C186D6-6AC5-49EB-A701-C91358B4A25F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fortinet:fortios:5.2.8:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DAC9F6C4-F887-4F25-87BD-383F6CF39806\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fortinet:fortios:5.2.9:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F8558962-7A19-4F4A-BED0-9CB5D4CFC422\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fortinet:fortios:5.4.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1668AE14-D9A4-4B7D-BC3F-75885792875A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fortinet:fortios:5.4.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9E0F3B9B-A06F-4A96-B2E7-9DC56E629182\"}]}]}],\"references\":[{\"url\":\"http://fortiguard.com/advisory/FG-IR-16-050\",\"source\":\"psirt@fortinet.com\",\"tags\":[\"Not Applicable\"]},{\"url\":\"http://www.securityfocus.com/bid/94690\",\"source\":\"psirt@fortinet.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://www.securitytracker.com/id/1037394\",\"source\":\"psirt@fortinet.com\"},{\"url\":\"http://fortiguard.com/advisory/FG-IR-16-050\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Not Applicable\"]},{\"url\":\"http://www.securityfocus.com/bid/94690\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://www.securitytracker.com/id/1037394\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"http://www.securityfocus.com/bid/94690\", \"name\": \"94690\", \"tags\": [\"vdb-entry\", \"x_refsource_BID\", \"x_transferred\"]}, {\"url\": \"http://fortiguard.com/advisory/FG-IR-16-050\", \"tags\": [\"x_refsource_CONFIRM\", \"x_transferred\"]}, {\"url\": \"http://www.securitytracker.com/id/1037394\", \"name\": \"1037394\", \"tags\": [\"vdb-entry\", \"x_refsource_SECTRACK\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-06T02:04:54.869Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2016-7542\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-10-23T14:00:57.607119Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-10-23T14:02:06.066Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"Fortinet\", \"product\": \"FortiOS\", \"versions\": [{\"status\": \"affected\", \"version\": \"5.2.0 - 5.2.9, 5.4.1\"}]}], \"datePublic\": \"2016-12-02T00:00:00\", \"references\": [{\"url\": \"http://www.securityfocus.com/bid/94690\", \"name\": \"94690\", \"tags\": [\"vdb-entry\", \"x_refsource_BID\"]}, {\"url\": \"http://fortiguard.com/advisory/FG-IR-16-050\", \"tags\": [\"x_refsource_CONFIRM\"]}, {\"url\": \"http://www.securitytracker.com/id/1037394\", \"name\": \"1037394\", \"tags\": [\"vdb-entry\", \"x_refsource_SECTRACK\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A read-only administrator on Fortinet devices with FortiOS 5.2.x before 5.2.10 GA and 5.4.x before 5.4.2 GA may have access to read-write administrators password hashes (not including super-admins) stored on the appliance via the webui REST API, and may therefore be able to crack them.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"Information leak\"}]}], \"providerMetadata\": {\"orgId\": \"6abe59d8-c742-4dff-8ce8-9b0ca1073da8\", \"shortName\": \"fortinet\", \"dateUpdated\": \"2017-07-27T09:57:01\"}, \"x_legacyV4Record\": {\"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"5.2.0 - 5.2.9, 5.4.1\"}]}, \"product_name\": \"FortiOS\"}]}, \"vendor_name\": \"Fortinet\"}]}}, \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"http://www.securityfocus.com/bid/94690\", \"name\": \"94690\", \"refsource\": \"BID\"}, {\"url\": \"http://fortiguard.com/advisory/FG-IR-16-050\", \"name\": \"http://fortiguard.com/advisory/FG-IR-16-050\", \"refsource\": \"CONFIRM\"}, {\"url\": \"http://www.securitytracker.com/id/1037394\", \"name\": \"1037394\", \"refsource\": \"SECTRACK\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"A read-only administrator on Fortinet devices with FortiOS 5.2.x before 5.2.10 GA and 5.4.x before 5.4.2 GA may have access to read-write administrators password hashes (not including super-admins) stored on the appliance via the webui REST API, and may therefore be able to crack them.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"Information leak\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2016-7542\", \"STATE\": \"PUBLIC\", \"ASSIGNER\": \"psirt@fortinet.com\"}}}}", "cveMetadata": "{\"cveId\": \"CVE-2016-7542\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-10-25T14:35:34.799Z\", \"dateReserved\": \"2016-09-09T00:00:00\", \"assignerOrgId\": \"6abe59d8-c742-4dff-8ce8-9b0ca1073da8\", \"datePublished\": \"2017-03-30T14:00:00\", \"assignerShortName\": \"fortinet\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.