CVE-2012-4714 (GCVE-0-2012-4714)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T20:42:54.993Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-095-02.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Integer overflow in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a large integer value." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2013-04-18T01:00:00Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-095-02.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2012-4714", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Integer overflow in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a large integer value." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://ics-cert.us-cert.gov/pdf/ICSA-13-095-02.pdf", "refsource": "MISC", "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-095-02.pdf" }, { "name": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599", "refsource": "CONFIRM", "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2012-4714", "datePublished": "2013-04-18T01:00:00Z", "dateReserved": "2012-08-28T00:00:00Z", "dateUpdated": "2024-09-16T20:46:39.149Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2012-4714\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2013-04-18T02:25:36.990\",\"lastModified\":\"2025-04-11T00:51:21.963\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Integer overflow in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a large integer value.\"},{\"lang\":\"es\",\"value\":\"Desbordamiento de entero en RNADiagnostics.dll de Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, y CPR9-SR6 permite a atacantes remotos causar una denegaci\u00f3n de servicio (interrupci\u00f3n del servicio o la ca\u00edda del demonio RNADiagReceiver.exe) a trav\u00e9s de los datos de UDP que especifica un gran valor entero.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:C\",\"baseScore\":7.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-189\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E47A7DE6-DA1D-4D35-B745-5EFB71A6394B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:sr1:*:*:*:*:*:*\",\"matchCriteriaId\":\"2DED3EBE-9371-46EB-9BCA-BA771AF10F61\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:sr2:*:*:*:*:*:*\",\"matchCriteriaId\":\"24D48E36-78BA-48F6-B839-73163BC53634\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:sr3:*:*:*:*:*:*\",\"matchCriteriaId\":\"D54DE200-9BF1-425F-914A-E70178E627A8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:sr4:*:*:*:*:*:*\",\"matchCriteriaId\":\"D9E3406C-AFF7-41BD-B4C3-258ED12C182C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:sr5:*:*:*:*:*:*\",\"matchCriteriaId\":\"E702BB80-DB34-4726-B64F-251C3E1730FD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:sr5.1:*:*:*:*:*:*\",\"matchCriteriaId\":\"C027452D-493A-46BB-B094-F2D3427B0D1F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:sr6:*:*:*:*:*:*\",\"matchCriteriaId\":\"229339FD-4EE3-49B1-8E57-00D5F4622A43\"}]}]}],\"references\":[{\"url\":\"http://ics-cert.us-cert.gov/pdf/ICSA-13-095-02.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"US Government Resource\"]},{\"url\":\"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"http://ics-cert.us-cert.gov/pdf/ICSA-13-095-02.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"US Government Resource\"]},{\"url\":\"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}" } }
gsd-2012-4714
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2012-4714", "description": "Integer overflow in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a large integer value.", "id": "GSD-2012-4714" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2012-4714" ], "details": "Integer overflow in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a large integer value.", "id": "GSD-2012-4714", "modified": "2023-12-13T01:20:15.336730Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2012-4714", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Integer overflow in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a large integer value." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://ics-cert.us-cert.gov/pdf/ICSA-13-095-02.pdf", "refsource": "MISC", "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-095-02.pdf" }, { "name": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599", "refsource": "CONFIRM", "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:sr4:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:sr5:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:sr5.1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:sr6:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:sr1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:sr3:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:sr2:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2012-4714" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "Integer overflow in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a large integer value." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-189" } ] } ] }, "references": { "reference_data": [ { "name": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599", "refsource": "CONFIRM", "tags": [], "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599" }, { "name": "http://ics-cert.us-cert.gov/pdf/ICSA-13-095-02.pdf", "refsource": "MISC", "tags": [ "US Government Resource" ], "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-095-02.pdf" } ] } }, "impact": { "baseMetricV2": { "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "userInteractionRequired": false } }, "lastModifiedDate": "2013-04-18T04:00Z", "publishedDate": "2013-04-18T02:25Z" } } }
var-201304-0008
Vulnerability from variot
Integer overflow in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a large integer value. The FactoryTalk Services Platform provides general services for products and applications in the FactoryTalk system (such as diagnostic information, health monitoring services, and real-time data access). The attacker can block subsequent links and cause a denial of service .
The following products are affected by this vulnerability:
CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1 and CPR9-SR6. FactoryTalk Services Platform is prone to a denial-of-service vulnerability. The following versions are vulnerable: FactoryTalk Services Platform CPR9 FactoryTalk Services Platform CPR9-SR1 FactoryTalk Services Platform CPR9-SR2 FactoryTalk Services Platform CPR9-SR3 FactoryTalk Services Platform CPR9-SR4 FactoryTalk Services Platform CPR9-SR5 FactoryTalk Services Platform CPR9-SR5.1 FactoryTalk Services Platform CPR9-SR6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201304-0008", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "factorytalk services platform", "scope": "eq", "trust": 1.6, "vendor": "rockwellautomation", "version": "cpr9" }, { "model": "factorytalk services platform", "scope": "eq", "trust": 0.8, "vendor": "rockwell automation", "version": "cpr9" }, { "model": "factorytalk services platform", "scope": "eq", "trust": 0.8, "vendor": "rockwell automation", "version": "cpr9-sr1" }, { "model": "factorytalk services platform", "scope": "eq", "trust": 0.8, "vendor": "rockwell automation", "version": "cpr9-sr2" }, { "model": "factorytalk services platform", "scope": "eq", "trust": 0.8, "vendor": "rockwell automation", "version": "cpr9-sr3" }, { "model": "factorytalk services platform", "scope": "eq", "trust": 0.8, "vendor": "rockwell automation", "version": "cpr9-sr4" }, { "model": "factorytalk services platform", "scope": "eq", "trust": 0.8, "vendor": "rockwell automation", "version": "cpr9-sr5" }, { "model": "factorytalk services platform", "scope": "eq", "trust": 0.8, "vendor": "rockwell automation", "version": "cpr9-sr5.1" }, { "model": "factorytalk services platform", "scope": "eq", "trust": 0.8, "vendor": "rockwell automation", "version": "cpr9-sr6" }, { "model": "automation factorytalk services platform", "scope": null, "trust": 0.6, "vendor": "rockwell", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2013-02815" }, { "db": "JVNDB", "id": "JVNDB-2013-002409" }, { "db": "CNNVD", "id": "CNNVD-201304-063" }, { "db": "NVD", "id": "CVE-2012-4714" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:rockwellautomation:factorytalk_services_platform", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2013-002409" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Carsten Eiram of Risk Based Security", "sources": [ { "db": "BID", "id": "58918" }, { "db": "CNNVD", "id": "CNNVD-201304-063" } ], "trust": 0.9 }, "cve": "CVE-2012-4714", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2012-4714", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2013-02815", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-57995", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2012-4714", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2012-4714", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2013-02815", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201304-063", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-57995", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2013-02815" }, { "db": "VULHUB", "id": "VHN-57995" }, { "db": "JVNDB", "id": "JVNDB-2013-002409" }, { "db": "CNNVD", "id": "CNNVD-201304-063" }, { "db": "NVD", "id": "CVE-2012-4714" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Integer overflow in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a large integer value. The FactoryTalk Services Platform provides general services for products and applications in the FactoryTalk system (such as diagnostic information, health monitoring services, and real-time data access). The attacker can block subsequent links and cause a denial of service . \n\nThe following products are affected by this vulnerability:\n\nCPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1 and CPR9-SR6. FactoryTalk Services Platform is prone to a denial-of-service vulnerability. \nThe following versions are vulnerable:\nFactoryTalk Services Platform CPR9\nFactoryTalk Services Platform CPR9-SR1\nFactoryTalk Services Platform CPR9-SR2\nFactoryTalk Services Platform CPR9-SR3\nFactoryTalk Services Platform CPR9-SR4\nFactoryTalk Services Platform CPR9-SR5\nFactoryTalk Services Platform CPR9-SR5.1\nFactoryTalk Services Platform CPR9-SR6", "sources": [ { "db": "NVD", "id": "CVE-2012-4714" }, { "db": "JVNDB", "id": "JVNDB-2013-002409" }, { "db": "CNVD", "id": "CNVD-2013-02815" }, { "db": "BID", "id": "58918" }, { "db": "VULHUB", "id": "VHN-57995" } ], "trust": 2.52 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2012-4714", "trust": 3.4 }, { "db": "ICS CERT", "id": "ICSA-13-095-02", "trust": 3.1 }, { "db": "BID", "id": "58918", "trust": 1.6 }, { "db": "JVNDB", "id": "JVNDB-2013-002409", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201304-063", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2013-02815", "trust": 0.6 }, { "db": "SECUNIA", "id": "52938", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-57995", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2013-02815" }, { "db": "VULHUB", "id": "VHN-57995" }, { "db": "BID", "id": "58918" }, { "db": "JVNDB", "id": "JVNDB-2013-002409" }, { "db": "CNNVD", "id": "CNNVD-201304-063" }, { "db": "NVD", "id": "CVE-2012-4714" } ] }, "id": "VAR-201304-0008", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2013-02815" }, { "db": "VULHUB", "id": "VHN-57995" } ], "trust": 1.1717742 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2013-02815" } ] }, "last_update_date": "2024-11-23T21:55:37.631000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "http://www.rockwellautomation.com/" }, { "title": "Partner", "trust": 0.8, "url": "http://jp.rockwellautomation.com/applications/gs/ap/gsjp.nsf/pages/partner" }, { "title": "Top Page", "trust": 0.8, "url": "http://jp.rockwellautomation.com/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2013-002409" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-189", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-57995" }, { "db": "JVNDB", "id": "JVNDB-2013-002409" }, { "db": "NVD", "id": "CVE-2012-4714" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.1, "url": "http://ics-cert.us-cert.gov/pdf/icsa-13-095-02.pdf" }, { "trust": 2.3, "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2012-4714" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2012-4714" }, { "trust": 0.6, "url": "http://secunia.com/advisories/52938" }, { "trust": 0.6, "url": "http://www.securityfocus.com/bid/58918" }, { "trust": 0.3, "url": "http://www.rockwellautomation.com/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2013-02815" }, { "db": "VULHUB", "id": "VHN-57995" }, { "db": "BID", "id": "58918" }, { "db": "JVNDB", "id": "JVNDB-2013-002409" }, { "db": "CNNVD", "id": "CNNVD-201304-063" }, { "db": "NVD", "id": "CVE-2012-4714" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2013-02815" }, { "db": "VULHUB", "id": "VHN-57995" }, { "db": "BID", "id": "58918" }, { "db": "JVNDB", "id": "JVNDB-2013-002409" }, { "db": "CNNVD", "id": "CNNVD-201304-063" }, { "db": "NVD", "id": "CVE-2012-4714" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2013-04-09T00:00:00", "db": "CNVD", "id": "CNVD-2013-02815" }, { "date": "2013-04-18T00:00:00", "db": "VULHUB", "id": "VHN-57995" }, { "date": "2013-04-05T00:00:00", "db": "BID", "id": "58918" }, { "date": "2013-04-22T00:00:00", "db": "JVNDB", "id": "JVNDB-2013-002409" }, { "date": "2013-04-11T00:00:00", "db": "CNNVD", "id": "CNNVD-201304-063" }, { "date": "2013-04-18T02:25:36.990000", "db": "NVD", "id": "CVE-2012-4714" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2013-04-09T00:00:00", "db": "CNVD", "id": "CNVD-2013-02815" }, { "date": "2013-04-18T00:00:00", "db": "VULHUB", "id": "VHN-57995" }, { "date": "2013-10-09T00:46:00", "db": "BID", "id": "58918" }, { "date": "2013-04-22T00:00:00", "db": "JVNDB", "id": "JVNDB-2013-002409" }, { "date": "2013-04-19T00:00:00", "db": "CNNVD", "id": "CNNVD-201304-063" }, { "date": "2024-11-21T01:43:24.317000", "db": "NVD", "id": "CVE-2012-4714" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201304-063" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Rockwell Automation FactoryTalk Services Platform of RNADiagnostics.dll Integer overflow vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2013-002409" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "digital error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201304-063" } ], "trust": 0.6 } }
icsa-13-095-02a
Vulnerability from csaf_cisa
Notes
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.", "title": "Recommended Practices" } ], "publisher": { "category": "coordinator", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-13-095-02A JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2013/icsa-13-095-02a.json" }, { "category": "self", "summary": "ICS Advisory ICSA-13-095-02A - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-13-095-02a" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014" } ], "title": "Rockwell Automation FactoryTalk and RSLinx Vulnerabilities", "tracking": { "current_release_date": "2025-06-06T16:00:35.472533Z", "generator": { "date": "2025-06-06T16:00:35.472449Z", "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-13-095-02A", "initial_release_date": "2013-01-07T07:00:00.000000Z", "revision_history": [ { "date": "2013-01-07T07:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Initial Publication" }, { "date": "2025-06-06T16:00:35.472533Z", "legacy_version": "CSAF Conversion", "number": "2", "summary": "Advisory converted into a CSAF" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version", "name": "CPR9", "product": { "name": "Rockwell Automation FactoryTalk Services Platform and RSLinx Enterprise: CPR9", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "FactoryTalk Services Platform and RSLinx Enterprise" }, { "branches": [ { "category": "product_version", "name": "CPR9-SR1", "product": { "name": "Rockwell Automation FactoryTalk Services Platform and RSLinx Enterprise: CPR9-SR1", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "FactoryTalk Services Platform and RSLinx Enterprise" }, { "branches": [ { "category": "product_version", "name": "CPR9-SR2", "product": { "name": "Rockwell Automation FactoryTalk Services Platform and RSLinx Enterprise: CPR9-SR2", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "FactoryTalk Services Platform and RSLinx Enterprise" }, { "branches": [ { "category": "product_version", "name": "CPR9-SR3", "product": { "name": "Rockwell Automation FactoryTalk Services Platform and RSLinx Enterprise: CPR9-SR3", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "FactoryTalk Services Platform and RSLinx Enterprise" }, { "branches": [ { "category": "product_version", "name": "CPR9-SR4", "product": { "name": "Rockwell Automation FactoryTalk Services Platform and RSLinx Enterprise: CPR9-SR4", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "FactoryTalk Services Platform and RSLinx Enterprise" }, { "branches": [ { "category": "product_version", "name": "CPR9-SR5", "product": { "name": "Rockwell Automation FactoryTalk Services Platform and RSLinx Enterprise: CPR9-SR5", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "FactoryTalk Services Platform and RSLinx Enterprise" }, { "branches": [ { "category": "product_version", "name": "CPR9-SR5.1", "product": { "name": "Rockwell Automation FactoryTalk Services Platform and RSLinx Enterprise: CPR9-SR5.1", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "FactoryTalk Services Platform and RSLinx Enterprise" }, { "branches": [ { "category": "product_version", "name": "CPR9-SR6", "product": { "name": "Rockwell Automation FactoryTalk Services Platform and RSLinx Enterprise: CPR9-SR6", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "FactoryTalk Services Platform and RSLinx Enterprise" } ], "category": "vendor", "name": "Rockwell Automation" } ] }, "vulnerabilities": [ { "cve": "CVE-2012-4695", "cwe": { "id": "CWE-703", "name": "Improper Check or Handling of Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "LogReceiver.exe in Rockwell Automation RSLinx Enterprise CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage) via a zero-byte UDP packet that is not properly handled by Logger.dll.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "remediations": [ { "category": "mitigation", "details": "Rockwell Automation\u2019s recommendation to asset owners using FTSP or RSLinx CPR9 through CPR9-SR4 is to upgrade to CPR9-SR5 or newer. Rockwell Automation also recommends that all asset owners using FTSP or RSLinx CPR9-SR5 and newer should apply the correlating patch for the version they are using.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation Security Advisory link (login is required): (https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599" }, { "category": "mitigation", "details": "In addition, asset owners can find security information for other Rockwell Automation products at the Security Advisory Index page link below (login is required): (https://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102" } ], "scores": [ { "cvss_v2": { "baseScore": 7.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ] }, { "cve": "CVE-2012-4713", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "Integer signedness error in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a negative integer value.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "remediations": [ { "category": "mitigation", "details": "Rockwell Automation\u2019s recommendation to asset owners using FTSP or RSLinx CPR9 through CPR9-SR4 is to upgrade to CPR9-SR5 or newer. Rockwell Automation also recommends that all asset owners using FTSP or RSLinx CPR9-SR5 and newer should apply the correlating patch for the version they are using.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation Security Advisory link (login is required): (https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599" }, { "category": "mitigation", "details": "In addition, asset owners can find security information for other Rockwell Automation products at the Security Advisory Index page link below (login is required): (https://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102" } ], "scores": [ { "cvss_v2": { "baseScore": 7.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ] }, { "cve": "CVE-2012-4714", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "Integer overflow in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a large integer value.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "remediations": [ { "category": "mitigation", "details": "Rockwell Automation\u2019s recommendation to asset owners using FTSP or RSLinx CPR9 through CPR9-SR4 is to upgrade to CPR9-SR5 or newer. Rockwell Automation also recommends that all asset owners using FTSP or RSLinx CPR9-SR5 and newer should apply the correlating patch for the version they are using.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation Security Advisory link (login is required): (https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599" }, { "category": "mitigation", "details": "In addition, asset owners can find security information for other Rockwell Automation products at the Security Advisory Index page link below (login is required): (https://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102" } ], "scores": [ { "cvss_v2": { "baseScore": 7.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ] }, { "cve": "CVE-2012-4715", "cwe": { "id": "CWE-703", "name": "Improper Check or Handling of Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "Buffer overflow in LogReceiver.exe in Rockwell Automation RSLinx Enterprise CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (daemon crash) or possibly execute arbitrary code via a UDP packet with a certain integer length value that is (1) too large or (2) too small, leading to improper handling by Logger.dll.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "remediations": [ { "category": "mitigation", "details": "Rockwell Automation\u2019s recommendation to asset owners using FTSP or RSLinx CPR9 through CPR9-SR4 is to upgrade to CPR9-SR5 or newer. Rockwell Automation also recommends that all asset owners using FTSP or RSLinx CPR9-SR5 and newer should apply the correlating patch for the version they are using.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation Security Advisory link (login is required): (https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599" }, { "category": "mitigation", "details": "In addition, asset owners can find security information for other Rockwell Automation products at the Security Advisory Index page link below (login is required): (https://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102" } ], "scores": [ { "cvss_v2": { "baseScore": 7.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ] }, { "cve": "CVE-2013-2805", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it receives a datagram with an incorrect value in the \u201cRecord Data Size\u201d field. By sending a datagram to the service over Port 4444/UDP with the \u201cRecord Data Size\u201d field modified to an oversized value, an attacker could cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to this vulnerability can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "remediations": [ { "category": "mitigation", "details": "Rockwell Automation\u2019s recommendation to asset owners using FTSP or RSLinx CPR9 through CPR9-SR4 is to upgrade to CPR9-SR5 or newer. Rockwell Automation also recommends that all asset owners using FTSP or RSLinx CPR9-SR5 and newer should apply the correlating patch for the version they are using.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation Security Advisory link (login is required): (https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599" }, { "category": "mitigation", "details": "In addition, asset owners can find security information for other Rockwell Automation products at the Security Advisory Index page link below (login is required): (https://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102" } ], "scores": [ { "cvss_v2": { "baseScore": 7.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ] }, { "cve": "CVE-2013-2806", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the \u201cEnd of Current Record\u201d field. By sending a datagram to the service over Port 4444/UDP with the \u201cRecord Data Size\u201d field modified to a specifically oversized value, the service will calculate an undersized value for the \u201cTotal Record Size.\u201d Then the service will calculate an incorrect value for the \u201cEnd of Current Record\u201d field causing access violations that lead to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation security advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "remediations": [ { "category": "mitigation", "details": "Rockwell Automation\u2019s recommendation to asset owners using FTSP or RSLinx CPR9 through CPR9-SR4 is to upgrade to CPR9-SR5 or newer. Rockwell Automation also recommends that all asset owners using FTSP or RSLinx CPR9-SR5 and newer should apply the correlating patch for the version they are using.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation Security Advisory link (login is required): (https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599" }, { "category": "mitigation", "details": "In addition, asset owners can find security information for other Rockwell Automation products at the Security Advisory Index page link below (login is required): (https://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102" } ], "scores": [ { "cvss_v2": { "baseScore": 7.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ] }, { "cve": "CVE-2013-2807", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the \u201cTotal Record Size\u201d field. By sending a datagram to the service over Port 4444/UDP with the \u201cRecord Data Size\u201d field modified to a specifically oversized value, the service will calculate an undersized value for the \u201cTotal Record Size\u201d that will cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "remediations": [ { "category": "mitigation", "details": "Rockwell Automation\u2019s recommendation to asset owners using FTSP or RSLinx CPR9 through CPR9-SR4 is to upgrade to CPR9-SR5 or newer. Rockwell Automation also recommends that all asset owners using FTSP or RSLinx CPR9-SR5 and newer should apply the correlating patch for the version they are using.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, { "category": "mitigation", "details": "The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation Security Advisory link (login is required): (https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599" }, { "category": "mitigation", "details": "In addition, asset owners can find security information for other Rockwell Automation products at the Security Advisory Index page link below (login is required): (https://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ], "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102" } ], "scores": [ { "cvss_v2": { "baseScore": 7.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ] } ] }
ghsa-mwv2-9vmf-ph7h
Vulnerability from github
Integer overflow in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a large integer value.
{ "affected": [], "aliases": [ "CVE-2012-4714" ], "database_specific": { "cwe_ids": [], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2013-04-18T02:25:00Z", "severity": "HIGH" }, "details": "Integer overflow in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a large integer value.", "id": "GHSA-mwv2-9vmf-ph7h", "modified": "2022-05-17T05:11:34Z", "published": "2022-05-17T05:11:34Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2012-4714" }, { "type": "WEB", "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599" }, { "type": "WEB", "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-095-02.pdf" } ], "schema_version": "1.4.0", "severity": [] }
fkie_cve-2012-4714
Vulnerability from fkie_nvd
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:*:*:*:*:*:*:*", "matchCriteriaId": "E47A7DE6-DA1D-4D35-B745-5EFB71A6394B", "vulnerable": true }, { "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:sr1:*:*:*:*:*:*", "matchCriteriaId": "2DED3EBE-9371-46EB-9BCA-BA771AF10F61", "vulnerable": true }, { "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:sr2:*:*:*:*:*:*", "matchCriteriaId": "24D48E36-78BA-48F6-B839-73163BC53634", "vulnerable": true }, { "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:sr3:*:*:*:*:*:*", "matchCriteriaId": "D54DE200-9BF1-425F-914A-E70178E627A8", "vulnerable": true }, { "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:sr4:*:*:*:*:*:*", "matchCriteriaId": "D9E3406C-AFF7-41BD-B4C3-258ED12C182C", "vulnerable": true }, { "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:sr5:*:*:*:*:*:*", "matchCriteriaId": "E702BB80-DB34-4726-B64F-251C3E1730FD", "vulnerable": true }, { "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:sr5.1:*:*:*:*:*:*", "matchCriteriaId": "C027452D-493A-46BB-B094-F2D3427B0D1F", "vulnerable": true }, { "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_services_platform:cpr9:sr6:*:*:*:*:*:*", "matchCriteriaId": "229339FD-4EE3-49B1-8E57-00D5F4622A43", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Integer overflow in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a large integer value." }, { "lang": "es", "value": "Desbordamiento de entero en RNADiagnostics.dll de Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, y CPR9-SR6 permite a atacantes remotos causar una denegaci\u00f3n de servicio (interrupci\u00f3n del servicio o la ca\u00edda del demonio RNADiagReceiver.exe) a trav\u00e9s de los datos de UDP que especifica un gran valor entero." } ], "id": "CVE-2012-4714", "lastModified": "2025-04-11T00:51:21.963", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ] }, "published": "2013-04-18T02:25:36.990", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "US Government Resource" ], "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-095-02.pdf" }, { "source": "ics-cert@hq.dhs.gov", "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "US Government Resource" ], "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-095-02.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Deferred", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-189" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.