Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T23:29:56.827Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://support.automation.siemens.com/WW/view/en/29054992" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf" }, { "name": "simatic-wincc-runtime-bo(69803)", "tags": [ "vdb-entry", "x_refsource_XF", "x_transferred" ], "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69803" }, { "name": "46011", "tags": [ "third-party-advisory", "x_refsource_SECUNIA", "x_transferred" ], "url": "http://secunia.com/advisories/46011" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2011-09-06T00:00:00", "descriptions": [ { "lang": "en", "value": "Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2017-08-28T12:57:01", "orgId": "37e5125f-f79b-445b-8fad-9564f167944b", "shortName": "certcc" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "http://support.automation.siemens.com/WW/view/en/29054992" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf" }, { "name": "simatic-wincc-runtime-bo(69803)", "tags": [ "vdb-entry", "x_refsource_XF" ], "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69803" }, { "name": "46011", "tags": [ "third-party-advisory", "x_refsource_SECUNIA" ], "url": "http://secunia.com/advisories/46011" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cert@cert.org", "ID": "CVE-2011-3321", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://support.automation.siemens.com/WW/view/en/29054992", "refsource": "MISC", "url": "http://support.automation.siemens.com/WW/view/en/29054992" }, { "name": "http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf", "refsource": "CONFIRM", "url": "http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf" }, { "name": "simatic-wincc-runtime-bo(69803)", "refsource": "XF", "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69803" }, { "name": "46011", "refsource": "SECUNIA", "url": "http://secunia.com/advisories/46011" }, { "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf", "refsource": "MISC", "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b", "assignerShortName": "certcc", "cveId": "CVE-2011-3321", "datePublished": "2011-09-15T21:00:00", "dateReserved": "2011-08-29T00:00:00", "dateUpdated": "2024-08-06T23:29:56.827Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2011-3321\",\"sourceIdentifier\":\"cret@cert.org\",\"published\":\"2011-09-16T12:35:26.450\",\"lastModified\":\"2024-11-21T01:30:15.513\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308.\"},{\"lang\":\"es\",\"value\":\"Desbordamiento de buffer de memoria din\u00e1mica en Siemens WinCC Runtime Advanced Loader, tal como se usa en SIMATIC WinCC flexible Runtime y SIMATIC WinCC (TIA Portal) Runtime Advanced, permite a atacantes remotos provocar una denegaci\u00f3n de servicio (corrupci\u00f3n de memoria) o posiblemente ejecutar c\u00f3digo arbitrario a trav\u00e9s de un paquete modificado al puerto TCP 2308.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:C/I:C/A:C\",\"baseScore\":9.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.6,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_flexible_runtime:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BA49B1B5-57A3-4405-964F-258B10BAD144\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:advanced:*:*:*\",\"matchCriteriaId\":\"1116304B-6CD9-4D44-BC95-B945D82873A4\"}]}]}],\"references\":[{\"url\":\"http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf\",\"source\":\"cret@cert.org\"},{\"url\":\"http://secunia.com/advisories/46011\",\"source\":\"cret@cert.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://support.automation.siemens.com/WW/view/en/29054992\",\"source\":\"cret@cert.org\"},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf\",\"source\":\"cret@cert.org\",\"tags\":[\"US Government Resource\"]},{\"url\":\"https://exchange.xforce.ibmcloud.com/vulnerabilities/69803\",\"source\":\"cret@cert.org\"},{\"url\":\"http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://secunia.com/advisories/46011\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://support.automation.siemens.com/WW/view/en/29054992\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"US Government Resource\"]},{\"url\":\"https://exchange.xforce.ibmcloud.com/vulnerabilities/69803\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.