Rockwell Automation CompactLogix 5370拒绝服务漏洞
Description
Rockwell Automation CompactLogix 5370是美国罗克韦尔(Rockwell Automation)公司的一款可编程逻辑控制器。 Rockwell Automation CompactLogix 5370存在拒绝服务漏洞,该漏洞源于发送格式错误的CIP forward open消息,攻击者可利用该漏洞导致重大不可恢复故障,需要重启才能恢复。
Severity
Patch Name
Rockwell Automation CompactLogix 5370拒绝服务漏洞的补丁
Patch Description
Rockwell Automation CompactLogix 5370是美国罗克韦尔(Rockwell Automation)公司的一款可编程逻辑控制器。 Rockwell Automation CompactLogix 5370存在拒绝服务漏洞,该漏洞源于发送格式错误的CIP forward open消息,攻击者可利用该漏洞导致重大不可恢复故障,需要重启才能恢复。目前,供应商发布了安全公告及相关补丁信息,修复了此漏洞。
Formal description

厂商已发布了漏洞修复程序,请及时关注更新: https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1770.html

Reference
https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1770.html
Impacted products
Name
['Rockwell Automation CompactLogix 5370 <=34.013', 'Rockwell Automation CompactLogix 5370 <=35.012', 'Rockwell Automation CompactLogix 5370 <=36.011']
Show details on source website

{
  "cves": {
    "cve": {
      "cveNumber": "CVE-2025-11743",
      "cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2025-11743"
    }
  },
  "description": "Rockwell Automation CompactLogix 5370\u662f\u7f8e\u56fd\u7f57\u514b\u97e6\u5c14\uff08Rockwell Automation\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u53ef\u7f16\u7a0b\u903b\u8f91\u63a7\u5236\u5668\u3002\n\nRockwell Automation CompactLogix 5370\u5b58\u5728\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u53d1\u9001\u683c\u5f0f\u9519\u8bef\u7684CIP forward open\u6d88\u606f\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5bfc\u81f4\u91cd\u5927\u4e0d\u53ef\u6062\u590d\u6545\u969c\uff0c\u9700\u8981\u91cd\u542f\u624d\u80fd\u6062\u590d\u3002",
  "formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1770.html",
  "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
  "number": "CNVD-2026-10855",
  "openTime": "2026-02-10",
  "patchDescription": "Rockwell Automation CompactLogix 5370\u662f\u7f8e\u56fd\u7f57\u514b\u97e6\u5c14\uff08Rockwell Automation\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u53ef\u7f16\u7a0b\u903b\u8f91\u63a7\u5236\u5668\u3002\r\n\r\nRockwell Automation CompactLogix 5370\u5b58\u5728\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u53d1\u9001\u683c\u5f0f\u9519\u8bef\u7684CIP forward open\u6d88\u606f\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5bfc\u81f4\u91cd\u5927\u4e0d\u53ef\u6062\u590d\u6545\u969c\uff0c\u9700\u8981\u91cd\u542f\u624d\u80fd\u6062\u590d\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
  "patchName": "Rockwell Automation CompactLogix 5370\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\u7684\u8865\u4e01",
  "products": {
    "product": [
      "Rockwell Automation CompactLogix 5370 \u003c=34.013",
      "Rockwell Automation CompactLogix 5370 \u003c=35.012",
      "Rockwell Automation CompactLogix 5370 \u003c=36.011"
    ]
  },
  "referenceLink": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1770.html",
  "serverity": "\u4e2d",
  "submitTime": "2026-01-30",
  "title": "Rockwell Automation CompactLogix 5370\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e"
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…