Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneImpacted products
Vendor | Product | Description | ||
---|---|---|---|---|
N/A | N/A | SCD6000 Industrial RTU version SCD6000 SY11012 11_M et antérieures | ||
N/A | N/A | Modicon BMENOC 0311 | ||
N/A | N/A | EVlink City (EVC1S22P4 / EVC1S7P4), EVlink Parking (EVW2 / EVF2 / EVP2PE), EVlink Smart Wallbox EVB1A toutes versions antérieures à R8 V3.4.0.2 | ||
N/A | N/A | Modicon BMENOC 0321 | ||
N/A | N/A | Modicon M580 | ||
N/A | N/A | EcoStruxure™ Power Monitoring Expert versions V9.0 et antérieures | ||
N/A | N/A | IGSS Data Collector (dc.exe) version 15.0.0.21320 et antérieures | ||
N/A | N/A | APDU9xxx with NMC3 version V1.0.0.28 et antérieures | ||
N/A | N/A | AP7xxxx and AP8xxx with NMC2 version V6.9.6 et antérieures | ||
N/A | N/A | AP7xxx and AP8xxx with NMC3 version V1.1.0.3 et antérieures |
References
Title | Publication Time | Tags | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "SCD6000 Industrial RTU version SCD6000 SY11012 11_M et ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Modicon BMENOC 0311", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "EVlink City (EVC1S22P4 / EVC1S7P4), EVlink Parking (EVW2 / EVF2 / EVP2PE), EVlink Smart Wallbox EVB1A toutes versions ant\u00e9rieures \u00e0 R8 V3.4.0.2", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Modicon BMENOC 0321", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Modicon M580", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "EcoStruxure\u2122 Power Monitoring Expert versions V9.0 et ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "IGSS Data Collector (dc.exe) version 15.0.0.21320 et ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "APDU9xxx with NMC3 version V1.0.0.28 et ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "AP7xxxx and AP8xxx with NMC2 version V6.9.6 et ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "AP7xxx and AP8xxx with NMC3 version V1.1.0.3 et ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2020-35198", "url": "https://www.cve.org/CVERecord?id=CVE-2020-35198" }, { "name": "CVE-2021-22725", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22725" }, { "name": "CVE-2019-6848", "url": "https://www.cve.org/CVERecord?id=CVE-2019-6848" }, { "name": "CVE-2021-22156", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22156" }, { "name": "CVE-2021-22823", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22823" }, { "name": "CVE-2021-22818", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22818" }, { "name": "CVE-2021-22820", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22820" }, { "name": "CVE-2021-22821", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22821" }, { "name": "CVE-2021-22824", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22824" }, { "name": "CVE-2021-22822", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22822" }, { "name": "CVE-2019-6849", "url": "https://www.cve.org/CVERecord?id=CVE-2019-6849" }, { "name": "CVE-2021-22825", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22825" }, { "name": "CVE-2021-44228", "url": "https://www.cve.org/CVERecord?id=CVE-2021-44228" }, { "name": "CVE-2021-22724", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22724" }, { "name": "CVE-2020-28895", "url": "https://www.cve.org/CVERecord?id=CVE-2020-28895" }, { "name": "CVE-2021-22826", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22826" }, { "name": "CVE-2019-6850", "url": "https://www.cve.org/CVERecord?id=CVE-2019-6850" }, { "name": "CVE-2021-22827", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22827" }, { "name": "CVE-2021-22819", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22819" } ], "initial_release_date": "2021-12-15T00:00:00", "last_revision_date": "2021-12-15T00:00:00", "links": [], "reference": "CERTFR-2021-AVI-953", "revisions": [ { "description": "Version initiale", "revision_date": "2021-12-15T00:00:00.000000" } ], "risks": [ { "description": "D\u00e9ni de service \u00e0 distance" }, { "description": "Injection de code indirecte \u00e0 distance (XSS)" }, { "description": "Injection de requ\u00eates ill\u00e9gitimes par rebond (CSRF)" }, { "description": "Ex\u00e9cution de code arbitraire \u00e0 distance" }, { "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es" }, { "description": "Contournement de la politique de s\u00e9curit\u00e9" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-348-02 du 14 d\u00e9cembre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-348-01 du 14 d\u00e9cembre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SSEVD-2021-348-03 du 14 d\u00e9cembre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-03" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2019-281-04 du 14 d\u00e9cembre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2019-281-04" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-348-04 du 14 d\u00e9cembre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-04" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-05 du 14 d\u00e9cembre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-05" } ] }
CVE-2021-22822 (GCVE-0-2021-22822)
Vulnerability from cvelistv5
Published
2022-01-28 19:09
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A CWE-79 Improper Neutralization of Input During Web Page Generation (�Cross-site Scripting�) vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)
References
URL | Tags | |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.563Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-79 Improper Neutralization of Input During Web Page Generation (\ufffdCross-site Scripting\ufffd) vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T19:09:38", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22822", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-79 Improper Neutralization of Input During Web Page Generation (\ufffdCross-site Scripting\ufffd) vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22822", "datePublished": "2022-01-28T19:09:38", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.563Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2019-6848 (GCVE-0-2019-6848)
Vulnerability from cvelistv5
Published
2019-10-29 14:53
Modified
2024-08-04 20:31
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-755 - Improper Handling of Exceptional Conditions
Summary
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info), which could cause a Denial of Service attack on the PLC when sending specific data on the REST API of the controller/communication module.
References
URL | Tags | ||||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info) |
Version: Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info) |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:31:04.396Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-04/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info)", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info)" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info), which could cause a Denial of Service attack on the PLC when sending specific data on the REST API of the controller/communication module." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-755", "description": "CWE-755: Improper Handling of Exceptional Conditions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-04-19T12:18:21", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-04/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2019-6848", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info)", "version": { "version_data": [ { "version_value": "Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info)" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info), which could cause a Denial of Service attack on the PLC when sending specific data on the REST API of the controller/communication module." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-755: Improper Handling of Exceptional Conditions" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.se.com/ww/en/download/document/SEVD-2019-281-04/", "refsource": "MISC", "url": "https://www.se.com/ww/en/download/document/SEVD-2019-281-04/" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2019-6848", "datePublished": "2019-10-29T14:53:10", "dateReserved": "2019-01-25T00:00:00", "dateUpdated": "2024-08-04T20:31:04.396Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22818 (GCVE-0-2021-22818)
Vulnerability from cvelistv5
Published
2022-01-28 19:09
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to gain unauthorized access to the charging station web interface by performing brute force attacks. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)
References
URL | Tags | |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.562Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to gain unauthorized access to the charging station web interface by performing brute force attacks. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T19:09:35", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22818", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to gain unauthorized access to the charging station web interface by performing brute force attacks. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22818", "datePublished": "2022-01-28T19:09:35", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.562Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22821 (GCVE-0-2021-22821)
Vulnerability from cvelistv5
Published
2022-01-28 19:09
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A CWE-918 Server-Side Request Forgery (SSRF) vulnerability exists that could cause the station web server to forward requests to unintended network targets when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)
References
URL | Tags | |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.453Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-918 Server-Side Request Forgery (SSRF) vulnerability exists that could cause the station web server to forward requests to unintended network targets when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T19:09:37", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22821", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-918 Server-Side Request Forgery (SSRF) vulnerability exists that could cause the station web server to forward requests to unintended network targets when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22821", "datePublished": "2022-01-28T19:09:37", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.453Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22725 (GCVE-0-2021-22725)
Vulnerability from cvelistv5
Published
2022-01-28 19:09
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A CVE-352 Cross-Site Request Forgery (CSRF) vulnerability exists that could allow an attacker to impersonate the user or carry out actions on their behalf when crafted malicious parameters are submitted in POST requests sent to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)
References
URL | Tags | |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.418Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CVE-352 Cross-Site Request Forgery (CSRF) vulnerability exists that could allow an attacker to impersonate the user or carry out actions on their behalf when crafted malicious parameters are submitted in POST requests sent to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T19:09:34", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22725", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CVE-352 Cross-Site Request Forgery (CSRF) vulnerability exists that could allow an attacker to impersonate the user or carry out actions on their behalf when crafted malicious parameters are submitted in POST requests sent to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22725", "datePublished": "2022-01-28T19:09:34", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.418Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22826 (GCVE-0-2021-22826)
Vulnerability from cvelistv5
Published
2022-01-28 19:09
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versions
References
URL | Tags | |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.530Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-03" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure\ufffd Power Monitoring Expert 9.0 and prior versions" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T19:09:38", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-03" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22826", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure\ufffd Power Monitoring Expert 9.0 and prior versions" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-03", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-03" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22826", "datePublished": "2022-01-28T19:09:38", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.530Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2019-6849 (GCVE-0-2019-6849)
Vulnerability from cvelistv5
Published
2019-10-29 14:53
Modified
2024-08-04 20:31
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-200 - Information Exposure
Summary
A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when using specific Modbus services provided by the REST API of the controller/communication module.
References
URL | Tags | ||||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321 |
Version: Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:31:04.468Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when using specific Modbus services provided by the REST API of the controller/communication module." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200: Information Exposure", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-10-29T14:53:44", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2019-6849", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321", "version": { "version_data": [ { "version_value": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when using specific Modbus services provided by the REST API of the controller/communication module." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-200: Information Exposure" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04", "refsource": "CONFIRM", "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2019-6849", "datePublished": "2019-10-29T14:53:44", "dateReserved": "2019-01-25T00:00:00", "dateUpdated": "2024-08-04T20:31:04.468Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22823 (GCVE-0-2021-22823)
Vulnerability from cvelistv5
Published
2022-02-11 17:40
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-306 - Missing Authentication for Critical Function
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)
References
URL | Tags | |
---|---|---|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior) |
Version: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior) |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.467Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306: Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-02-11T17:40:39", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22823", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)", "version": { "version_data": [ { "version_value": "Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-306: Missing Authentication for Critical Function" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22823", "datePublished": "2022-02-11T17:40:39", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.467Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22820 (GCVE-0-2021-22820)
Vulnerability from cvelistv5
Published
2022-01-28 19:09
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access over a hijacked session to the charger station web server even after the legitimate user account holder has changed his password. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)
References
URL | Tags | |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.469Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access over a hijacked session to the charger station web server even after the legitimate user account holder has changed his password. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T19:09:36", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22820", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access over a hijacked session to the charger station web server even after the legitimate user account holder has changed his password. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22820", "datePublished": "2022-01-28T19:09:36", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.469Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-44228 (GCVE-0-2021-44228)
Vulnerability from cvelistv5
Published
2021-12-10 00:00
Modified
2025-07-30 01:37
Severity ?
VLAI Severity ?
EPSS score ?
CWE
Summary
Apache Log4j2 2.0-beta9 through 2.15.0 (excluding security releases 2.12.2, 2.12.3, and 2.3.1) JNDI features used in configuration, log messages, and parameters do not protect against attacker controlled LDAP and other JNDI related endpoints. An attacker who can control log messages or log message parameters can execute arbitrary code loaded from LDAP servers when message lookup substitution is enabled. From log4j 2.15.0, this behavior has been disabled by default. From version 2.16.0 (along with 2.12.2, 2.12.3, and 2.3.1), this functionality has been completely removed. Note that this vulnerability is specific to log4j-core and does not affect log4net, log4cxx, or other Apache Logging Services projects.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Apache Software Foundation | Apache Log4j2 |
Version: 2.0-beta9 < log4j-core* |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:17:24.696Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://logging.apache.org/log4j/2.x/security.html" }, { "name": "[oss-security] 20211210 CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints", "tags": [ "mailing-list", "x_transferred" ], "url": "http://www.openwall.com/lists/oss-security/2021/12/10/1" }, { "name": "[oss-security] 20211210 Re: CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints", "tags": [ "mailing-list", "x_transferred" ], "url": "http://www.openwall.com/lists/oss-security/2021/12/10/2" }, { "name": "20211210 Vulnerability in Apache Log4j Library Affecting Cisco Products: December 2021", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd" }, { "name": "[oss-security] 20211210 Re: CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints", "tags": [ "mailing-list", "x_transferred" ], "url": "http://www.openwall.com/lists/oss-security/2021/12/10/3" }, { "tags": [ "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20211210-0007/" }, { "tags": [ "x_transferred" ], "url": "http://packetstormsecurity.com/files/165225/Apache-Log4j2-2.14.1-Remote-Code-Execution.html" }, { "tags": [ "x_transferred" ], "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0032" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com/security-alerts/alert-cve-2021-44228.html" }, { "name": "DSA-5020", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.debian.org/security/2021/dsa-5020" }, { "name": "[debian-lts-announce] 20211212 [SECURITY] [DLA 2842-1] apache-log4j2 security update", "tags": [ "mailing-list", "x_transferred" ], "url": "https://lists.debian.org/debian-lts-announce/2021/12/msg00007.html" }, { "name": "FEDORA-2021-f0f501d01f", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/VU57UJDCFIASIO35GC55JMKSRXJMCDFM/" }, { "name": "Microsoft\u2019s Response to CVE-2021-44228 Apache Log4j 2", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://msrc-blog.microsoft.com/2021/12/11/microsofts-response-to-cve-2021-44228-apache-log4j2/" }, { "name": "[oss-security] 20211213 Re: CVE-2021-4104: Deserialization of untrusted data in JMSAppender in Apache Log4j 1.2", "tags": [ "mailing-list", "x_transferred" ], "url": "http://www.openwall.com/lists/oss-security/2021/12/13/2" }, { "name": "[oss-security] 20211213 CVE-2021-4104: Deserialization of untrusted data in JMSAppender in Apache Log4j 1.2", "tags": [ "mailing-list", "x_transferred" ], "url": "http://www.openwall.com/lists/oss-security/2021/12/13/1" }, { "name": "[oss-security] 20211214 CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack", "tags": [ "mailing-list", "x_transferred" ], "url": "http://www.openwall.com/lists/oss-security/2021/12/14/4" }, { "name": "20211210 A Vulnerability in Apache Log4j Library Affecting Cisco Products: December 2021", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd" }, { "name": "VU#930724", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://www.kb.cert.org/vuls/id/930724" }, { "tags": [ "x_transferred" ], "url": "https://twitter.com/kurtseifried/status/1469345530182455296" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661247.pdf" }, { "tags": [ "x_transferred" ], "url": "http://packetstormsecurity.com/files/165260/VMware-Security-Advisory-2021-0028.html" }, { "tags": [ "x_transferred" ], "url": "http://packetstormsecurity.com/files/165270/Apache-Log4j2-2.14.1-Remote-Code-Execution.html" }, { "tags": [ "x_transferred" ], "url": "http://packetstormsecurity.com/files/165261/Apache-Log4j2-2.14.1-Information-Disclosure.html" }, { "tags": [ "x_transferred" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00646.html" }, { "name": "20211210 Vulnerabilities in Apache Log4j Library Affecting Cisco Products: December 2021", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd" }, { "name": "[oss-security] 20211215 Re: CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack", "tags": [ "mailing-list", "x_transferred" ], "url": "http://www.openwall.com/lists/oss-security/2021/12/15/3" }, { "tags": [ "x_transferred" ], "url": "http://packetstormsecurity.com/files/165282/Log4j-Payload-Generator.html" }, { "tags": [ "x_transferred" ], "url": "http://packetstormsecurity.com/files/165281/Log4j2-Log4Shell-Regexes.html" }, { "tags": [ "x_transferred" ], "url": "http://packetstormsecurity.com/files/165307/Log4j-Remote-Code-Execution-Word-Bypassing.html" }, { "tags": [ "x_transferred" ], "url": "http://packetstormsecurity.com/files/165311/log4j-scan-Extensive-Scanner.html" }, { "tags": [ "x_transferred" ], "url": "http://packetstormsecurity.com/files/165306/L4sh-Log4j-Remote-Code-Execution.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-714170.pdf" }, { "name": "FEDORA-2021-66d6c484f3", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/M5CSVUNV4HWZZXGOKNSK6L7RPM7BOKIB/" }, { "tags": [ "x_transferred" ], "url": "http://packetstormsecurity.com/files/165371/VMware-Security-Advisory-2021-0028.4.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-397453.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479842.pdf" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpujan2022.html" }, { "tags": [ "x_transferred" ], "url": "http://packetstormsecurity.com/files/165532/Log4Shell-HTTP-Header-Injection.html" }, { "tags": [ "x_transferred" ], "url": "https://github.com/cisagov/log4j-affected-db/blob/develop/SOFTWARE-LIST.md" }, { "tags": [ "x_transferred" ], "url": "http://packetstormsecurity.com/files/165642/VMware-vCenter-Server-Unauthenticated-Log4Shell-JNDI-Injection-Remote-Code-Execution.html" }, { "tags": [ "x_transferred" ], "url": "http://packetstormsecurity.com/files/165673/UniFi-Network-Application-Unauthenticated-Log4Shell-Remote-Code-Execution.html" }, { "name": "20220314 APPLE-SA-2022-03-14-7 Xcode 13.3", "tags": [ "mailing-list", "x_transferred" ], "url": "http://seclists.org/fulldisclosure/2022/Mar/23" }, { "tags": [ "x_transferred" ], "url": "https://www.bentley.com/en/common-vulnerability-exposure/be-2022-0001" }, { "tags": [ "x_transferred" ], "url": "https://github.com/cisagov/log4j-affected-db" }, { "tags": [ "x_transferred" ], "url": "https://support.apple.com/kb/HT213189" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" }, { "tags": [ "x_transferred" ], "url": "https://github.com/nu11secur1ty/CVE-mitre/tree/main/CVE-2021-44228" }, { "tags": [ "x_transferred" ], "url": "https://www.nu11secur1ty.com/2021/12/cve-2021-44228.html" }, { "name": "20220721 Open-Xchange Security Advisory 2022-07-21", "tags": [ "mailing-list", "x_transferred" ], "url": "http://seclists.org/fulldisclosure/2022/Jul/11" }, { "tags": [ "x_transferred" ], "url": "http://packetstormsecurity.com/files/167794/Open-Xchange-App-Suite-7.10.x-Cross-Site-Scripting-Command-Injection.html" }, { "tags": [ "x_transferred" ], "url": "http://packetstormsecurity.com/files/167917/MobileIron-Log4Shell-Remote-Command-Execution.html" }, { "name": "20221208 Intel Data Center Manager \u003c= 5.1 Local Privileges Escalation", "tags": [ "mailing-list", "x_transferred" ], "url": "http://seclists.org/fulldisclosure/2022/Dec/2" }, { "tags": [ "x_transferred" ], "url": "http://packetstormsecurity.com/files/171626/AD-Manager-Plus-7122-Remote-Code-Execution.html" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2021-44228", "options": [ { "Exploitation": "active" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-04T14:25:34.416117Z", "version": "2.0.3" }, "type": "ssvc" } }, { "other": { "content": { "dateAdded": "2021-12-10", "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-44228" }, "type": "kev" } } ], "providerMetadata": { "dateUpdated": "2025-07-30T01:37:52.215Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "timeline": [ { "lang": "en", "time": "2021-12-10T00:00:00+00:00", "value": "CVE-2021-44228 added to CISA KEV" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Apache Log4j2", "vendor": "Apache Software Foundation", "versions": [ { "changes": [ { "at": "2.3.1", "status": "unaffected" }, { "at": "2.4", "status": "affected" }, { "at": "2.12.2", "status": "unaffected" }, { "at": "2.13.0", "status": "affected" }, { "at": "2.15.0", "status": "unaffected" } ], "lessThan": "log4j-core*", "status": "affected", "version": "2.0-beta9", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "This issue was discovered by Chen Zhaojun of Alibaba Cloud Security Team." } ], "descriptions": [ { "lang": "en", "value": "Apache Log4j2 2.0-beta9 through 2.15.0 (excluding security releases 2.12.2, 2.12.3, and 2.3.1) JNDI features used in configuration, log messages, and parameters do not protect against attacker controlled LDAP and other JNDI related endpoints. An attacker who can control log messages or log message parameters can execute arbitrary code loaded from LDAP servers when message lookup substitution is enabled. From log4j 2.15.0, this behavior has been disabled by default. From version 2.16.0 (along with 2.12.2, 2.12.3, and 2.3.1), this functionality has been completely removed. Note that this vulnerability is specific to log4j-core and does not affect log4net, log4cxx, or other Apache Logging Services projects." } ], "metrics": [ { "other": { "content": { "other": "critical" }, "type": "unknown" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-502", "description": "CWE-502 Deserialization of Untrusted Data", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400 Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20 Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-03T00:00:00.000Z", "orgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09", "shortName": "apache" }, "references": [ { "url": "https://logging.apache.org/log4j/2.x/security.html" }, { "name": "[oss-security] 20211210 CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints", "tags": [ "mailing-list" ], "url": "http://www.openwall.com/lists/oss-security/2021/12/10/1" }, { "name": "[oss-security] 20211210 Re: CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints", "tags": [ "mailing-list" ], "url": "http://www.openwall.com/lists/oss-security/2021/12/10/2" }, { "name": "20211210 Vulnerability in Apache Log4j Library Affecting Cisco Products: December 2021", "tags": [ "vendor-advisory" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd" }, { "name": "[oss-security] 20211210 Re: CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints", "tags": [ "mailing-list" ], "url": "http://www.openwall.com/lists/oss-security/2021/12/10/3" }, { "url": "https://security.netapp.com/advisory/ntap-20211210-0007/" }, { "url": "http://packetstormsecurity.com/files/165225/Apache-Log4j2-2.14.1-Remote-Code-Execution.html" }, { "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0032" }, { "url": "https://www.oracle.com/security-alerts/alert-cve-2021-44228.html" }, { "name": "DSA-5020", "tags": [ "vendor-advisory" ], "url": "https://www.debian.org/security/2021/dsa-5020" }, { "name": "[debian-lts-announce] 20211212 [SECURITY] [DLA 2842-1] apache-log4j2 security update", "tags": [ "mailing-list" ], "url": "https://lists.debian.org/debian-lts-announce/2021/12/msg00007.html" }, { "name": "FEDORA-2021-f0f501d01f", "tags": [ "vendor-advisory" ], "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/VU57UJDCFIASIO35GC55JMKSRXJMCDFM/" }, { "name": "Microsoft\u2019s Response to CVE-2021-44228 Apache Log4j 2", "tags": [ "vendor-advisory" ], "url": "https://msrc-blog.microsoft.com/2021/12/11/microsofts-response-to-cve-2021-44228-apache-log4j2/" }, { "name": "[oss-security] 20211213 Re: CVE-2021-4104: Deserialization of untrusted data in JMSAppender in Apache Log4j 1.2", "tags": [ "mailing-list" ], "url": "http://www.openwall.com/lists/oss-security/2021/12/13/2" }, { "name": "[oss-security] 20211213 CVE-2021-4104: Deserialization of untrusted data in JMSAppender in Apache Log4j 1.2", "tags": [ "mailing-list" ], "url": "http://www.openwall.com/lists/oss-security/2021/12/13/1" }, { "name": "[oss-security] 20211214 CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack", "tags": [ "mailing-list" ], "url": "http://www.openwall.com/lists/oss-security/2021/12/14/4" }, { "name": "20211210 A Vulnerability in Apache Log4j Library Affecting Cisco Products: December 2021", "tags": [ "vendor-advisory" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd" }, { "name": "VU#930724", "tags": [ "third-party-advisory" ], "url": "https://www.kb.cert.org/vuls/id/930724" }, { "url": "https://twitter.com/kurtseifried/status/1469345530182455296" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661247.pdf" }, { "url": "http://packetstormsecurity.com/files/165260/VMware-Security-Advisory-2021-0028.html" }, { "url": "http://packetstormsecurity.com/files/165270/Apache-Log4j2-2.14.1-Remote-Code-Execution.html" }, { "url": "http://packetstormsecurity.com/files/165261/Apache-Log4j2-2.14.1-Information-Disclosure.html" }, { "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00646.html" }, { "name": "20211210 Vulnerabilities in Apache Log4j Library Affecting Cisco Products: December 2021", "tags": [ "vendor-advisory" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd" }, { "name": "[oss-security] 20211215 Re: CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack", "tags": [ "mailing-list" ], "url": "http://www.openwall.com/lists/oss-security/2021/12/15/3" }, { "url": "http://packetstormsecurity.com/files/165282/Log4j-Payload-Generator.html" }, { "url": "http://packetstormsecurity.com/files/165281/Log4j2-Log4Shell-Regexes.html" }, { "url": "http://packetstormsecurity.com/files/165307/Log4j-Remote-Code-Execution-Word-Bypassing.html" }, { "url": "http://packetstormsecurity.com/files/165311/log4j-scan-Extensive-Scanner.html" }, { "url": "http://packetstormsecurity.com/files/165306/L4sh-Log4j-Remote-Code-Execution.html" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-714170.pdf" }, { "name": "FEDORA-2021-66d6c484f3", "tags": [ "vendor-advisory" ], "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/M5CSVUNV4HWZZXGOKNSK6L7RPM7BOKIB/" }, { "url": "http://packetstormsecurity.com/files/165371/VMware-Security-Advisory-2021-0028.4.html" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-397453.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479842.pdf" }, { "url": "https://www.oracle.com/security-alerts/cpujan2022.html" }, { "url": "http://packetstormsecurity.com/files/165532/Log4Shell-HTTP-Header-Injection.html" }, { "url": "https://github.com/cisagov/log4j-affected-db/blob/develop/SOFTWARE-LIST.md" }, { "url": "http://packetstormsecurity.com/files/165642/VMware-vCenter-Server-Unauthenticated-Log4Shell-JNDI-Injection-Remote-Code-Execution.html" }, { "url": "http://packetstormsecurity.com/files/165673/UniFi-Network-Application-Unauthenticated-Log4Shell-Remote-Code-Execution.html" }, { "name": "20220314 APPLE-SA-2022-03-14-7 Xcode 13.3", "tags": [ "mailing-list" ], "url": "http://seclists.org/fulldisclosure/2022/Mar/23" }, { "url": "https://www.bentley.com/en/common-vulnerability-exposure/be-2022-0001" }, { "url": "https://github.com/cisagov/log4j-affected-db" }, { "url": "https://support.apple.com/kb/HT213189" }, { "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" }, { "url": "https://github.com/nu11secur1ty/CVE-mitre/tree/main/CVE-2021-44228" }, { "url": "https://www.nu11secur1ty.com/2021/12/cve-2021-44228.html" }, { "name": "20220721 Open-Xchange Security Advisory 2022-07-21", "tags": [ "mailing-list" ], "url": "http://seclists.org/fulldisclosure/2022/Jul/11" }, { "url": "http://packetstormsecurity.com/files/167794/Open-Xchange-App-Suite-7.10.x-Cross-Site-Scripting-Command-Injection.html" }, { "url": "http://packetstormsecurity.com/files/167917/MobileIron-Log4Shell-Remote-Command-Execution.html" }, { "name": "20221208 Intel Data Center Manager \u003c= 5.1 Local Privileges Escalation", "tags": [ "mailing-list" ], "url": "http://seclists.org/fulldisclosure/2022/Dec/2" }, { "url": "http://packetstormsecurity.com/files/171626/AD-Manager-Plus-7122-Remote-Code-Execution.html" } ], "source": { "discovery": "UNKNOWN" }, "title": "Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints", "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09", "assignerShortName": "apache", "cveId": "CVE-2021-44228", "datePublished": "2021-12-10T00:00:00.000Z", "dateReserved": "2021-11-26T00:00:00.000Z", "dateUpdated": "2025-07-30T01:37:52.215Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22824 (GCVE-0-2021-22824)
Vulnerability from cvelistv5
Published
2022-02-11 17:40
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-120 - Buffer Copy without Checking Size of Input
Summary
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)
References
URL | Tags | |
---|---|---|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior) |
Version: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior) |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.555Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120: Buffer Copy without Checking Size of Input", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-02-11T17:40:40", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22824", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)", "version": { "version_data": [ { "version_value": "Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-120: Buffer Copy without Checking Size of Input" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22824", "datePublished": "2022-02-11T17:40:40", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.555Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22156 (GCVE-0-2021-22156)
Vulnerability from cvelistv5
Published
2021-08-17 18:35
Modified
2025-08-22 15:20
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Denial of service or arbitrary code execution
- CWE-190 - Integer Overflow or Wraparound
Summary
An integer overflow vulnerability in the calloc() function of the C runtime library of affected versions of BlackBerry® QNX Software Development Platform (SDP) version(s) 6.5.0SP1 and earlier, QNX OS for Medical 1.1 and earlier, and QNX OS for Safety 1.0.1 and earlier that could allow an attacker to potentially perform a denial of service or execute arbitrary code.
References
URL | Tags | |||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
BlackBerry | QNX Software Development Platform (SDP), QNX OS for Medical and QNX OS for Safety |
Version: QNX SDP 6.5.0 SP1 and earlier Version: QNX OS for Medical 1.1 and earlier Version: QNX OS for Safety 1.0.1 and earlier |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:37:17.775Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://support.blackberry.com/kb/articleDetail?articleNumber=000082334" }, { "name": "20210818 BlackBerry QNX-2021-001 Vulnerability Affecting Cisco Products: August 2021", "tags": [ "vendor-advisory", "x_refsource_CISCO", "x_transferred" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-qnx-TOxjVPdL" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "QNX Software Development Platform (SDP), QNX OS for Medical and QNX OS for Safety", "vendor": "BlackBerry", "versions": [ { "status": "affected", "version": "QNX SDP 6.5.0 SP1 and earlier" }, { "status": "affected", "version": "QNX OS for Medical 1.1 and earlier" }, { "status": "affected", "version": "QNX OS for Safety 1.0.1 and earlier" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eAn integer overflow vulnerability in the calloc() function of the C runtime library of affected versions of BlackBerry\u00ae QNX Software Development Platform (SDP) version(s) 6.5.0SP1 and earlier, QNX OS for Medical 1.1 and earlier, and QNX OS for Safety 1.0.1 and earlier that could allow an attacker to potentially perform a denial of service or execute arbitrary code.\u003c/p\u003e" } ], "value": "An integer overflow vulnerability in the calloc() function of the C runtime library of affected versions of BlackBerry\u00ae QNX Software Development Platform (SDP) version(s) 6.5.0SP1 and earlier, QNX OS for Medical 1.1 and earlier, and QNX OS for Safety 1.0.1 and earlier that could allow an attacker to potentially perform a denial of service or execute arbitrary code." } ], "impacts": [ { "capecId": "CAPEC-92", "descriptions": [ { "lang": "en", "value": "CAPEC-92 Forced Integer Overflow" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "description": "Denial of service or arbitrary code execution", "lang": "en" } ] }, { "descriptions": [ { "cweId": "CWE-190", "description": "CWE-190 Integer Overflow or Wraparound", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-08-22T15:20:31.911Z", "orgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c", "shortName": "blackberry" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://support.blackberry.com/kb/articleDetail?articleNumber=000082334" }, { "name": "20210818 BlackBerry QNX-2021-001 Vulnerability Affecting Cisco Products: August 2021", "tags": [ "vendor-advisory", "x_refsource_CISCO" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-qnx-TOxjVPdL" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "secure@blackberry.com", "ID": "CVE-2021-22156", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "BlackBerry QNX Software Development Platform (SDP), QNX OS for Medical and QNX OS for Safety", "version": { "version_data": [ { "version_value": "QNX SDP 6.5.0 SP1 and earlier" }, { "version_value": "QNX OS for Medical 1.1 and earlier" }, { "version_value": "QNX OS for Safety 1.0.1 and earlier" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An integer overflow vulnerability in the calloc() function of the C runtime library of affected versions of BlackBerry\u00ae QNX Software Development Platform (SDP) version(s) 6.5.0SP1 and earlier, QNX OS for Medical 1.1 and earlier, and QNX OS for Safety 1.0.1 and earlier that could allow an attacker to potentially perform a denial of service or execute arbitrary code." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Denial of service or arbitrary code execution" } ] } ] }, "references": { "reference_data": [ { "name": "https://support.blackberry.com/kb/articleDetail?articleNumber=000082334", "refsource": "MISC", "url": "https://support.blackberry.com/kb/articleDetail?articleNumber=000082334" }, { "name": "20210818 BlackBerry QNX-2021-001 Vulnerability Affecting Cisco Products: August 2021", "refsource": "CISCO", "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-qnx-TOxjVPdL" } ] } } } }, "cveMetadata": { "assignerOrgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c", "assignerShortName": "blackberry", "cveId": "CVE-2021-22156", "datePublished": "2021-08-17T18:35:38", "dateReserved": "2021-01-04T00:00:00", "dateUpdated": "2025-08-22T15:20:31.911Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-35198 (GCVE-0-2020-35198)
Vulnerability from cvelistv5
Published
2021-05-12 10:55
Modified
2024-08-04 17:02
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
An issue was discovered in Wind River VxWorks 7. The memory allocator has a possible integer overflow in calculating a memory block's size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.
References
URL | Tags | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T17:02:06.842Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://support2.windriver.com/index.php?page=security-notices" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-35198" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An issue was discovered in Wind River VxWorks 7. The memory allocator has a possible integer overflow in calculating a memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-19T23:22:42", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://support2.windriver.com/index.php?page=security-notices" }, { "tags": [ "x_refsource_MISC" ], "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-35198" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-35198", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered in Wind River VxWorks 7. The memory allocator has a possible integer overflow in calculating a memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://support2.windriver.com/index.php?page=security-notices", "refsource": "MISC", "url": "https://support2.windriver.com/index.php?page=security-notices" }, { "name": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-35198", "refsource": "MISC", "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-35198" }, { "name": "https://www.oracle.com/security-alerts/cpuapr2022.html", "refsource": "MISC", "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-35198", "datePublished": "2021-05-12T10:55:47", "dateReserved": "2020-12-12T00:00:00", "dateUpdated": "2024-08-04T17:02:06.842Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2019-6850 (GCVE-0-2019-6850)
Vulnerability from cvelistv5
Published
2019-10-29 14:54
Modified
2024-08-04 20:31
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-200 - Information Exposure
Summary
A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when reading specific registers with the REST API of the controller/communication module.
References
URL | Tags | ||||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321 |
Version: Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:31:04.356Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when reading specific registers with the REST API of the controller/communication module." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200: Information Exposure", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-10-29T14:54:39", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2019-6850", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321", "version": { "version_data": [ { "version_value": "Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when reading specific registers with the REST API of the controller/communication module." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-200: Information Exposure" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04", "refsource": "CONFIRM", "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-04" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2019-6850", "datePublished": "2019-10-29T14:54:39", "dateReserved": "2019-01-25T00:00:00", "dateUpdated": "2024-08-04T20:31:04.356Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22827 (GCVE-0-2021-22827)
Vulnerability from cvelistv5
Published
2022-01-28 19:09
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22826. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versions
References
URL | Tags | |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.511Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-03" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22826. Affected Product: EcoStruxure\ufffd Power Monitoring Expert 9.0 and prior versions" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T19:09:39", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-03" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22827", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22826. Affected Product: EcoStruxure\ufffd Power Monitoring Expert 9.0 and prior versions" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-03", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-03" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22827", "datePublished": "2022-01-28T19:09:39", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.511Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22724 (GCVE-0-2021-22724)
Vulnerability from cvelistv5
Published
2022-01-28 19:09
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A CVE-352 Cross-Site Request Forgery (CSRF) vulnerability exists that could allow an attacker to impersonate the user or carry out actions on their behalf when crafted malicious parameters are submitted in POST requests sent to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)
References
URL | Tags | |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.217Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CVE-352 Cross-Site Request Forgery (CSRF) vulnerability exists that could allow an attacker to impersonate the user or carry out actions on their behalf when crafted malicious parameters are submitted in POST requests sent to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T19:09:33", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22724", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CVE-352 Cross-Site Request Forgery (CSRF) vulnerability exists that could allow an attacker to impersonate the user or carry out actions on their behalf when crafted malicious parameters are submitted in POST requests sent to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22724", "datePublished": "2022-01-28T19:09:33", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.217Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22819 (GCVE-0-2021-22819)
Vulnerability from cvelistv5
Published
2022-01-28 19:09
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A CWE-1021 Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause unintended modifications of the product settings or user accounts when deceiving the user to use the web interface rendered within iframes. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)
References
URL | Tags | |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.443Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-1021 Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause unintended modifications of the product settings or user accounts when deceiving the user to use the web interface rendered within iframes. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T19:09:35", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22819", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-1021 Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause unintended modifications of the product settings or user accounts when deceiving the user to use the web interface rendered within iframes. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22819", "datePublished": "2022-01-28T19:09:35", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.443Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22825 (GCVE-0-2021-22825)
Vulnerability from cvelistv5
Published
2022-01-28 19:09
Modified
2025-09-08 16:09
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could allow an attacker to access the system with elevated privileges when a privileged account clicks on a malicious URL that compromises the security token. Affected Products: AP7xxxx and AP8xxx with NMC2 (V6.9.6 or earlier), AP7xxx and AP8xxx with NMC3 (V1.1.0.3 or earlier), and APDU9xxx with NMC3 (V1.0.0.28 or earlier)
References
URL | Tags | |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.440Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-04" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2021-22825", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-09-08T16:07:27.598238Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-09-08T16:09:21.462Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could allow an attacker to access the system with elevated privileges when a privileged account clicks on a malicious URL that compromises the security token. Affected Products: AP7xxxx and AP8xxx with NMC2 (V6.9.6 or earlier), AP7xxx and AP8xxx with NMC3 (V1.1.0.3 or earlier), and APDU9xxx with NMC3 (V1.0.0.28 or earlier)" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T19:09:40.000Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-04" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22825", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could allow an attacker to access the system with elevated privileges when a privileged account clicks on a malicious URL that compromises the security token. Affected Products: AP7xxxx and AP8xxx with NMC2 (V6.9.6 or earlier), AP7xxx and AP8xxx with NMC3 (V1.1.0.3 or earlier), and APDU9xxx with NMC3 (V1.0.0.28 or earlier)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-04", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-04" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22825", "datePublished": "2022-01-28T19:09:40.000Z", "dateReserved": "2021-01-06T00:00:00.000Z", "dateUpdated": "2025-09-08T16:09:21.462Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-28895 (GCVE-0-2020-28895)
Vulnerability from cvelistv5
Published
2021-02-03 15:16
Modified
2024-08-04 16:41
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block's size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.
References
URL | Tags | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:41:00.095Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "credits": [ { "lang": "en", "value": "Reported by Omri Ben Bassat \u003cv-obenbassat@microsoft.com\u003e" } ], "datePublic": "2020-12-14T00:00:00", "descriptions": [ { "lang": "en", "value": "In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-19T23:22:39", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327" }, { "tags": [ "x_refsource_MISC" ], "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" } ], "source": { "discovery": "EXTERNAL" }, "title": "integer overflow in calloc", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-28895", "STATE": "PUBLIC", "TITLE": "integer overflow in calloc" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "credit": [ { "lang": "eng", "value": "Reported by Omri Ben Bassat \u003cv-obenbassat@microsoft.com\u003e" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327", "refsource": "MISC", "url": "https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327" }, { "name": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895", "refsource": "MISC", "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895" }, { "name": "https://www.oracle.com/security-alerts/cpuapr2022.html", "refsource": "MISC", "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" } ] }, "source": { "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-28895", "datePublished": "2021-02-03T15:16:34", "dateReserved": "2020-11-17T00:00:00", "dateUpdated": "2024-08-04T16:41:00.095Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…