CERTFR-2020-AVI-090
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens . Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à la confidentialité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneImpacted products
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SIMATIC IPC427D, IPC427E (incl. variante SIPLUS) | ||
| Siemens | N/A | SIMATIC Route Control V8.1 | ||
| Siemens | N/A | SCALANCE M-800 / S615 versions antérieures à V6.1.2 | ||
| Siemens | N/A | SIMATIC WinCC (TIA Portal) V16 | ||
| Siemens | N/A | SIMATIC S7-1200 CPU (incl. variante SIPLUS) | ||
| Siemens | N/A | SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. variante SIPLUS) | ||
| Siemens | N/A | OpenPCS 7 V9.0 | ||
| Siemens | N/A | SIMATIC S7-1500 Software Controller versions antérieures à 20.8 | ||
| Siemens | N/A | SIMATIC ET200MP IM155-5 PN ST (incl. variante SIPLUS) versions antérieures à V4.1.0 | ||
| Siemens | N/A | SIMATIC ET200SP IM155-6 PN ST (incl. variante SIPLUS) versions antérieures à V4.1.0 | ||
| Siemens | N/A | SIMATIC Field PG M4, Field PG M5, Field PG M6 | ||
| Siemens | N/A | SIMATIC S7-400 PN/DP CPU V7 (incl. variante SIPLUS) | ||
| Siemens | N/A | SIPROTEC 4 et SIPROTEC Compact relays equipped with EN100 Ethernet communication modules | ||
| Siemens | N/A | SIMATIC Route Control V8.2 | ||
| Siemens | N/A | SIPORT MP versions antérieures à V3.1.4 | ||
| Siemens | N/A | SCALANCE X-200IRT switch (incl. variante SIPLUS NET) versions antérieures à V5.4.2 | ||
| Siemens | N/A | OZW672 versions antérieures à V10.00 | ||
| Siemens | N/A | SIMATIC CP 1626 | ||
| Siemens | N/A | SCALANCE X-200 switch (incl. variante SIPLUS NET) versions antérieures à V5.2.4 | ||
| Siemens | N/A | SIMATIC CP 1543-1 (incl. variante SIPLUS NET) versions antérieures V2.2 | ||
| Siemens | N/A | SIMATIC NET PC Software | ||
| Siemens | N/A | RUGGEDCOM RM1224 versions antérieures à V6.1.2 | ||
| Siemens | N/A | SIMATIC WinCC V7.3 | ||
| Siemens | N/A | SIMATIC PCS 7 V8.1 | ||
| Siemens | N/A | SCALANCE X-300 switch (incl. X408 et variante SIPLUS NET) versions antérieures à V4.1.3 | ||
| Siemens | N/A | SIMATIC PCS 7 V9.0 | ||
| Siemens | N/A | SCALANCE S602, S612, S623, S627-2M, S627-2M | ||
| Siemens | N/A | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P versions antérieures à V4.6 | ||
| Siemens | N/A | SIMATIC BATCH V8.1 | ||
| Siemens | N/A | SIMATIC BATCH V9.0 | ||
| Siemens | N/A | SIMATIC RF182C | ||
| Siemens | N/A | SCALANCE XR-500 switch versions antérieures à V6.2.3 | ||
| Siemens | N/A | SIMATIC WinCC (TIA Portal) V13 versions antérieures à V13 SP2 | ||
| Siemens | N/A | SCALANCE W700 IEEE 802.11n versions antérieures à V6.4 | ||
| Siemens | N/A | SIMOTION P320-4S | ||
| Siemens | N/A | SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incl. variante SIPLUS NET) | ||
| Siemens | N/A | IE/PB LINK PN IO (incl. variante SIPLUS NET) | ||
| Siemens | N/A | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 versions antérieures à V4.5 Patch 01 | ||
| Siemens | N/A | SIMATIC ET200SP IM155-6 PN HF (incl. variante SIPLUS) versions antérieures à V4.2.2 | ||
| Siemens | N/A | SIMATIC S7-300 PN/DP CPU (incl. les CPUS ET200 associées et variantes SIPLUS) | ||
| Siemens | N/A | SIMATIC RF180C | ||
| Siemens | N/A | SIMATIC CP 343-1 Advanced, CP 343-1, CP 343-1 LEAN, CP 443-1 Advanced, CP 443-1 (incl. variante SIPLUS NET) | ||
| Siemens | N/A | SCALANCE XB-200, XC-200, XP-200, XF-200BA and XR-300WG versions antérieures à V4.1 | ||
| Siemens | N/A | SIMATIC PCS 7 V8.2 | ||
| Siemens | N/A | TIM 1531 IRC (incl. variante SIPLUS NET) versions antérieures à V2.0 | ||
| Siemens | N/A | SIMATIC CP 343-1 ERPC, CP 443-1 OPC UA | ||
| Siemens | N/A | SIMATIC MV400 | ||
| Siemens | N/A | OZW772 versions antérieures à V10.00 | ||
| Siemens | N/A | SIMATIC IPC Support, Package for VxWorks | ||
| Siemens | N/A | SIMATIC WinCC (TIA Portal) V15.1 | ||
| Siemens | N/A | SINAMICS DCP versions antérieures à V1.3 | ||
| Siemens | N/A | SIMATIC CP 1616 et CP 1604 versions antérieures à V2.8.1 | ||
| Siemens | N/A | SIMATIC ET200pro, IM 154-3 PN HF et ET200pro, IM 154-4 PN HF | ||
| Siemens | N/A | SIMATIC WinCC (TIA Portal) V14.0.1 | ||
| Siemens | N/A | SIMATIC IPC127E, IPC427C, IPC477C, IPC477D, IPC477E, IPC477E Pro, IPC527G, IPC547E, IPC547G, IPC627C, IPC627D, IPC627E, IPC647C, IPC647D, IPC647E, IPC677C, IPC677D, IPC677E, IPC827C, IPC827D, IPC827E, IPC847C, IPC847D, IPC847E | ||
| Siemens | N/A | SIMATIC RF600 versions antérieures à V3.2.1 | ||
| Siemens | N/A | SIMATIC ET200AL IM 157-1 PN, ET200ecoPN (excepté 6ES7148-6JD00-0AB0 et 6ES7146-6FF00-0AB0), ET200M IM153-4 PN IO HF (incl. variante SIPLUS), ET200M IM153-4 PN IO ST (incl. variante SIPLUS) | ||
| Siemens | N/A | SIMATIC ET200MP IM155-5 PN HF (incl. variante SIPLUS) versions antérieures à V4.2.0 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU (incl. les CPUS ET200 associées et variantes SIPLUS) versions antérieures à 2.8 | ||
| Siemens | N/A | OpenPCS 7 V8.2 | ||
| Siemens | N/A | SIMATIC CP 1628 versions antérieures à V14.00.15.00_51.25.00.01 | ||
| Siemens | N/A | SIMATIC WinCC V7.5 versions antérieures à 7.5.1 Upd1 | ||
| Siemens | N/A | SIMATIC CP 1623 versions antérieures à V14.00.15.00_51.25.00.01 | ||
| Siemens | N/A | SIMATIC ITP1000 | ||
| Siemens | N/A | SIMATIC Route Control V9.0 | ||
| Siemens | N/A | SIMATIC ET200S, ET200SP IM155-6 PN Basic (incl. variante SIPLUS) | ||
| Siemens | N/A | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller | ||
| Siemens | N/A | OpenPCS 7 V8.1 | ||
| Siemens | N/A | SIMATIC S7-400 PN/DP CPU V6 et antérieures (incl. variante SIPLUS) | ||
| Siemens | N/A | SIMATIC WinCC V7.4 | ||
| Siemens | N/A | SCALANCE XM-400 switch versions antérieures à V6.2.3 | ||
| Siemens | N/A | PROFINET Driver for Controller versions antérieures à V2.1 Patch 03 | ||
| Siemens | N/A | SIMOTION P320-4E | ||
| Siemens | N/A | SIMATIC BATCH V8.2 |
References
| Title | Publication Time | Tags | ||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SIMATIC IPC427D, IPC427E (incl. variante SIPLUS)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Route Control V8.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE M-800 / S615 versions ant\u00e9rieures \u00e0 V6.1.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC (TIA Portal) V16",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1200 CPU (incl. variante SIPLUS)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. variante SIPLUS)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "OpenPCS 7 V9.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 Software Controller versions ant\u00e9rieures \u00e0 20.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET200MP IM155-5 PN ST (incl. variante SIPLUS) versions ant\u00e9rieures \u00e0 V4.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET200SP IM155-6 PN ST (incl. variante SIPLUS) versions ant\u00e9rieures \u00e0 V4.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Field PG M4, Field PG M5, Field PG M6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-400 PN/DP CPU V7 (incl. variante SIPLUS)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPROTEC 4 et SIPROTEC Compact relays equipped with EN100 Ethernet communication modules",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Route Control V8.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPORT MP versions ant\u00e9rieures \u00e0 V3.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X-200IRT switch (incl. variante SIPLUS NET) versions ant\u00e9rieures \u00e0 V5.4.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "OZW672 versions ant\u00e9rieures \u00e0 V10.00",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1626",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X-200 switch (incl. variante SIPLUS NET) versions ant\u00e9rieures \u00e0 V5.2.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1543-1 (incl. variante SIPLUS NET) versions ant\u00e9rieures V2.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET PC Software",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RM1224 versions ant\u00e9rieures \u00e0 V6.1.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC V7.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS 7 V8.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X-300 switch (incl. X408 et variante SIPLUS NET) versions ant\u00e9rieures \u00e0 V4.1.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS 7 V9.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE S602, S612, S623, S627-2M, S627-2M",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P versions ant\u00e9rieures \u00e0 V4.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC BATCH V8.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC BATCH V9.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF182C",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR-500 switch versions ant\u00e9rieures \u00e0 V6.2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC (TIA Portal) V13 versions ant\u00e9rieures \u00e0 V13 SP2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W700 IEEE 802.11n versions ant\u00e9rieures \u00e0 V6.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOTION P320-4S",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incl. variante SIPLUS NET)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "IE/PB LINK PN IO (incl. variante SIPLUS NET)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 versions ant\u00e9rieures \u00e0 V4.5 Patch 01",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET200SP IM155-6 PN HF (incl. variante SIPLUS) versions ant\u00e9rieures \u00e0 V4.2.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 PN/DP CPU (incl. les CPUS ET200 associ\u00e9es et variantes SIPLUS)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF180C",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 343-1 Advanced, CP 343-1, CP 343-1 LEAN, CP 443-1 Advanced, CP 443-1 (incl. variante SIPLUS NET)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB-200, XC-200, XP-200, XF-200BA and XR-300WG versions ant\u00e9rieures \u00e0 V4.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS 7 V8.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 1531 IRC (incl. variante SIPLUS NET) versions ant\u00e9rieures \u00e0 V2.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 343-1 ERPC, CP 443-1 OPC UA",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV400",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "OZW772 versions ant\u00e9rieures \u00e0 V10.00",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC Support, Package for VxWorks",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC (TIA Portal) V15.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS DCP versions ant\u00e9rieures \u00e0 V1.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1616 et CP 1604 versions ant\u00e9rieures \u00e0 V2.8.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET200pro, IM 154-3 PN HF et ET200pro, IM 154-4 PN HF",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC (TIA Portal) V14.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC127E, IPC427C, IPC477C, IPC477D, IPC477E, IPC477E Pro, IPC527G, IPC547E, IPC547G, IPC627C, IPC627D, IPC627E, IPC647C, IPC647D, IPC647E, IPC677C, IPC677D, IPC677E, IPC827C, IPC827D, IPC827E, IPC847C, IPC847D, IPC847E",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF600 versions ant\u00e9rieures \u00e0 V3.2.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET200AL IM 157-1 PN, ET200ecoPN (except\u00e9 6ES7148-6JD00-0AB0 et 6ES7146-6FF00-0AB0), ET200M IM153-4 PN IO HF (incl. variante SIPLUS), ET200M IM153-4 PN IO ST (incl. variante SIPLUS)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET200MP IM155-5 PN HF (incl. variante SIPLUS) versions ant\u00e9rieures \u00e0 V4.2.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU (incl. les CPUS ET200 associ\u00e9es et variantes SIPLUS) versions ant\u00e9rieures \u00e0 2.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "OpenPCS 7 V8.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1628 versions ant\u00e9rieures \u00e0 V14.00.15.00_51.25.00.01",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC V7.5 versions ant\u00e9rieures \u00e0 7.5.1 Upd1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1623 versions ant\u00e9rieures \u00e0 V14.00.15.00_51.25.00.01",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ITP1000",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Route Control V9.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET200S, ET200SP IM155-6 PN Basic (incl. variante SIPLUS)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "OpenPCS 7 V8.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-400 PN/DP CPU V6 et ant\u00e9rieures (incl. variante SIPLUS)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC V7.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XM-400 switch versions ant\u00e9rieures \u00e0 V6.2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "PROFINET Driver for Controller versions ant\u00e9rieures \u00e0 V2.1 Patch 03",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOTION P320-4E",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC BATCH V8.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2019-19282",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19282"
},
{
"name": "CVE-2019-19277",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19277"
},
{
"name": "CVE-2019-13926",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13926"
},
{
"name": "CVE-2019-0152",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-0152"
},
{
"name": "CVE-2019-0169",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-0169"
},
{
"name": "CVE-2019-19281",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19281"
},
{
"name": "CVE-2019-13941",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13941"
},
{
"name": "CVE-2015-5621",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-5621"
},
{
"name": "CVE-2019-18217",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18217"
},
{
"name": "CVE-2019-12815",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-12815"
},
{
"name": "CVE-2019-13940",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13940"
},
{
"name": "CVE-2019-19279",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19279"
},
{
"name": "CVE-2019-13925",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13925"
},
{
"name": "CVE-2019-0151",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-0151"
},
{
"name": "CVE-2019-13946",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13946"
},
{
"name": "CVE-2019-6585",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6585"
},
{
"name": "CVE-2020-19282",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-19282"
},
{
"name": "CVE-2019-13924",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13924"
},
{
"name": "CVE-2018-18065",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-18065"
}
],
"initial_release_date": "2020-02-13T00:00:00",
"last_revision_date": "2020-02-13T00:00:00",
"links": [],
"reference": "CERTFR-2020-AVI-090",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2020-02-13T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens . Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et une atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-398519 du 11 f\u00e9vrier 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-398519.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-940889 du 11 f\u00e9vrier 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940889.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-974843 du 11 f\u00e9vrier 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-974843.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-270778 du 11 f\u00e9vrier 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-270778.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-780073 du 11 f\u00e9vrier 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-780073.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-986695 du 11 f\u00e9vrier 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-986695.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-750824 du 11 f\u00e9vrier 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-750824.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-951513 du 11 f\u00e9vrier 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-951513.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-431678 du 11 f\u00e9vrier 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-431678.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-591405 du 11 f\u00e9vrier 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-978558 du 11 f\u00e9vrier 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-978558.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-978220 du 11 f\u00e9vrier 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-978220.pdf"
}
]
}
CVE-2019-0151 (GCVE-0-2019-0151)
Vulnerability from cvelistv5
Published
2019-11-14 19:07
Modified
2024-08-04 17:44
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Escalation of Privilege
Summary
Insufficient memory protection in Intel(R) TXT for certain Intel(R) Core Processors and Intel(R) Xeon(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access.
References
| URL | Tags | |
|---|---|---|
|
|
||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | 2019.2 IPU – Intel(R) Processor Security |
Version: See provided reference |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T17:44:14.639Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00240.html"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03971en_us"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.f5.com/csp/article/K34425791?utm_source=f5support\u0026amp%3Butm_medium=RSS"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-398519.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "2019.2 IPU \u2013 Intel(R) Processor Security",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See provided reference"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insufficient memory protection in Intel(R) TXT for certain Intel(R) Core Processors and Intel(R) Xeon(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Escalation of Privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-11T11:06:02",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00240.html"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03971en_us"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.f5.com/csp/article/K34425791?utm_source=f5support\u0026amp%3Butm_medium=RSS"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-398519.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2019-0151",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "2019.2 IPU \u2013 Intel(R) Processor Security",
"version": {
"version_data": [
{
"version_value": "See provided reference"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Insufficient memory protection in Intel(R) TXT for certain Intel(R) Core Processors and Intel(R) Xeon(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Escalation of Privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00240.html",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00240.html"
},
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03971en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03971en_us"
},
{
"name": "https://support.f5.com/csp/article/K34425791?utm_source=f5support\u0026amp;utm_medium=RSS",
"refsource": "CONFIRM",
"url": "https://support.f5.com/csp/article/K34425791?utm_source=f5support\u0026amp;utm_medium=RSS"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-398519.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-398519.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2019-0151",
"datePublished": "2019-11-14T19:07:09",
"dateReserved": "2018-11-13T00:00:00",
"dateUpdated": "2024-08-04T17:44:14.639Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-18065 (GCVE-0-2018-18065)
Vulnerability from cvelistv5
Published
2018-10-08 18:00
Modified
2024-08-05 11:01
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
_set_key in agent/helpers/table_container.c in Net-SNMP before 5.8 has a NULL Pointer Exception bug that can be used by an authenticated attacker to remotely cause the instance to crash via a crafted UDP packet, resulting in Denial of Service.
References
| URL | Tags | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T11:01:14.813Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://sourceforge.net/p/net-snmp/code/ci/7ffb8e25a0db851953155de91f0170e9bf8c457d/"
},
{
"name": "45547",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB",
"x_transferred"
],
"url": "https://www.exploit-db.com/exploits/45547/"
},
{
"name": "USN-3792-1",
"tags": [
"vendor-advisory",
"x_refsource_UBUNTU",
"x_transferred"
],
"url": "https://usn.ubuntu.com/3792-1/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://dumpco.re/blog/net-snmp-5.7.3-remote-dos"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20181107-0001/"
},
{
"name": "USN-3792-2",
"tags": [
"vendor-advisory",
"x_refsource_UBUNTU",
"x_transferred"
],
"url": "https://usn.ubuntu.com/3792-2/"
},
{
"name": "USN-3792-3",
"tags": [
"vendor-advisory",
"x_refsource_UBUNTU",
"x_transferred"
],
"url": "https://usn.ubuntu.com/3792-3/"
},
{
"name": "DSA-4314",
"tags": [
"vendor-advisory",
"x_refsource_DEBIAN",
"x_transferred"
],
"url": "https://www.debian.org/security/2018/dsa-4314"
},
{
"name": "106265",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/106265"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.oracle.com/technetwork/security-advisory/cpuoct2019-5072832.html"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-978220.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.paloaltonetworks.com/CVE-2018-18065"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-10-08T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "_set_key in agent/helpers/table_container.c in Net-SNMP before 5.8 has a NULL Pointer Exception bug that can be used by an authenticated attacker to remotely cause the instance to crash via a crafted UDP packet, resulting in Denial of Service."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-17T16:03:47",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://sourceforge.net/p/net-snmp/code/ci/7ffb8e25a0db851953155de91f0170e9bf8c457d/"
},
{
"name": "45547",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB"
],
"url": "https://www.exploit-db.com/exploits/45547/"
},
{
"name": "USN-3792-1",
"tags": [
"vendor-advisory",
"x_refsource_UBUNTU"
],
"url": "https://usn.ubuntu.com/3792-1/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://dumpco.re/blog/net-snmp-5.7.3-remote-dos"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20181107-0001/"
},
{
"name": "USN-3792-2",
"tags": [
"vendor-advisory",
"x_refsource_UBUNTU"
],
"url": "https://usn.ubuntu.com/3792-2/"
},
{
"name": "USN-3792-3",
"tags": [
"vendor-advisory",
"x_refsource_UBUNTU"
],
"url": "https://usn.ubuntu.com/3792-3/"
},
{
"name": "DSA-4314",
"tags": [
"vendor-advisory",
"x_refsource_DEBIAN"
],
"url": "https://www.debian.org/security/2018/dsa-4314"
},
{
"name": "106265",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/106265"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.oracle.com/technetwork/security-advisory/cpuoct2019-5072832.html"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-978220.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.paloaltonetworks.com/CVE-2018-18065"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-18065",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "_set_key in agent/helpers/table_container.c in Net-SNMP before 5.8 has a NULL Pointer Exception bug that can be used by an authenticated attacker to remotely cause the instance to crash via a crafted UDP packet, resulting in Denial of Service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://sourceforge.net/p/net-snmp/code/ci/7ffb8e25a0db851953155de91f0170e9bf8c457d/",
"refsource": "MISC",
"url": "https://sourceforge.net/p/net-snmp/code/ci/7ffb8e25a0db851953155de91f0170e9bf8c457d/"
},
{
"name": "45547",
"refsource": "EXPLOIT-DB",
"url": "https://www.exploit-db.com/exploits/45547/"
},
{
"name": "USN-3792-1",
"refsource": "UBUNTU",
"url": "https://usn.ubuntu.com/3792-1/"
},
{
"name": "https://dumpco.re/blog/net-snmp-5.7.3-remote-dos",
"refsource": "MISC",
"url": "https://dumpco.re/blog/net-snmp-5.7.3-remote-dos"
},
{
"name": "https://security.netapp.com/advisory/ntap-20181107-0001/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20181107-0001/"
},
{
"name": "USN-3792-2",
"refsource": "UBUNTU",
"url": "https://usn.ubuntu.com/3792-2/"
},
{
"name": "USN-3792-3",
"refsource": "UBUNTU",
"url": "https://usn.ubuntu.com/3792-3/"
},
{
"name": "DSA-4314",
"refsource": "DEBIAN",
"url": "https://www.debian.org/security/2018/dsa-4314"
},
{
"name": "106265",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/106265"
},
{
"name": "https://www.oracle.com/technetwork/security-advisory/cpuoct2019-5072832.html",
"refsource": "MISC",
"url": "https://www.oracle.com/technetwork/security-advisory/cpuoct2019-5072832.html"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-978220.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-978220.pdf"
},
{
"name": "https://security.paloaltonetworks.com/CVE-2018-18065",
"refsource": "CONFIRM",
"url": "https://security.paloaltonetworks.com/CVE-2018-18065"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-18065",
"datePublished": "2018-10-08T18:00:00",
"dateReserved": "2018-10-08T00:00:00",
"dateUpdated": "2024-08-05T11:01:14.813Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-12815 (GCVE-0-2019-12815)
Vulnerability from cvelistv5
Published
2019-07-19 22:56
Modified
2024-08-04 23:32
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
An arbitrary file copy vulnerability in mod_copy in ProFTPD up to 1.3.5b allows for remote code execution and information disclosure without authentication, a related issue to CVE-2015-3306.
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:32:55.303Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://tbspace.de/cve201912815proftpd.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://bugs.proftpd.org/show_bug.cgi?id=4372"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/proftpd/proftpd/pull/816"
},
{
"name": "109339",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/109339"
},
{
"name": "FEDORA-2019-82b0f48691",
"tags": [
"vendor-advisory",
"x_refsource_FEDORA",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/XM5FPBAGSIKV6YJZEPM6GPGJO5JFT7XU/"
},
{
"name": "FEDORA-2019-e9187610c3",
"tags": [
"vendor-advisory",
"x_refsource_FEDORA",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/OJDQ3XUYWO42TJBO53NUWDZRA35QMVEI/"
},
{
"name": "20190805 [SECURITY] [DSA 4491-1] proftpd-dfsg security update",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ",
"x_transferred"
],
"url": "https://seclists.org/bugtraq/2019/Aug/3"
},
{
"name": "DSA-4491",
"tags": [
"vendor-advisory",
"x_refsource_DEBIAN",
"x_transferred"
],
"url": "https://www.debian.org/security/2019/dsa-4491"
},
{
"name": "[debian-lts-announce] 20190807 [SECURITY] [DLA 1873-1] proftpd-dfsg security update",
"tags": [
"mailing-list",
"x_refsource_MLIST",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2019/08/msg00006.html"
},
{
"name": "openSUSE-SU-2019:1836",
"tags": [
"vendor-advisory",
"x_refsource_SUSE",
"x_transferred"
],
"url": "http://lists.opensuse.org/opensuse-security-announce/2019-08/msg00004.html"
},
{
"name": "openSUSE-SU-2019:1870",
"tags": [
"vendor-advisory",
"x_refsource_SUSE",
"x_transferred"
],
"url": "http://lists.opensuse.org/opensuse-security-announce/2019-08/msg00022.html"
},
{
"name": "GLSA-201908-16",
"tags": [
"vendor-advisory",
"x_refsource_GENTOO",
"x_transferred"
],
"url": "https://security.gentoo.org/glsa/201908-16"
},
{
"name": "openSUSE-SU-2020:0031",
"tags": [
"vendor-advisory",
"x_refsource_SUSE",
"x_transferred"
],
"url": "http://lists.opensuse.org/opensuse-security-announce/2020-01/msg00009.html"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940889.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An arbitrary file copy vulnerability in mod_copy in ProFTPD up to 1.3.5b allows for remote code execution and information disclosure without authentication, a related issue to CVE-2015-3306."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-11T10:06:15",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://tbspace.de/cve201912815proftpd.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://bugs.proftpd.org/show_bug.cgi?id=4372"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/proftpd/proftpd/pull/816"
},
{
"name": "109339",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/109339"
},
{
"name": "FEDORA-2019-82b0f48691",
"tags": [
"vendor-advisory",
"x_refsource_FEDORA"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/XM5FPBAGSIKV6YJZEPM6GPGJO5JFT7XU/"
},
{
"name": "FEDORA-2019-e9187610c3",
"tags": [
"vendor-advisory",
"x_refsource_FEDORA"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/OJDQ3XUYWO42TJBO53NUWDZRA35QMVEI/"
},
{
"name": "20190805 [SECURITY] [DSA 4491-1] proftpd-dfsg security update",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ"
],
"url": "https://seclists.org/bugtraq/2019/Aug/3"
},
{
"name": "DSA-4491",
"tags": [
"vendor-advisory",
"x_refsource_DEBIAN"
],
"url": "https://www.debian.org/security/2019/dsa-4491"
},
{
"name": "[debian-lts-announce] 20190807 [SECURITY] [DLA 1873-1] proftpd-dfsg security update",
"tags": [
"mailing-list",
"x_refsource_MLIST"
],
"url": "https://lists.debian.org/debian-lts-announce/2019/08/msg00006.html"
},
{
"name": "openSUSE-SU-2019:1836",
"tags": [
"vendor-advisory",
"x_refsource_SUSE"
],
"url": "http://lists.opensuse.org/opensuse-security-announce/2019-08/msg00004.html"
},
{
"name": "openSUSE-SU-2019:1870",
"tags": [
"vendor-advisory",
"x_refsource_SUSE"
],
"url": "http://lists.opensuse.org/opensuse-security-announce/2019-08/msg00022.html"
},
{
"name": "GLSA-201908-16",
"tags": [
"vendor-advisory",
"x_refsource_GENTOO"
],
"url": "https://security.gentoo.org/glsa/201908-16"
},
{
"name": "openSUSE-SU-2020:0031",
"tags": [
"vendor-advisory",
"x_refsource_SUSE"
],
"url": "http://lists.opensuse.org/opensuse-security-announce/2020-01/msg00009.html"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940889.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-12815",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An arbitrary file copy vulnerability in mod_copy in ProFTPD up to 1.3.5b allows for remote code execution and information disclosure without authentication, a related issue to CVE-2015-3306."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://tbspace.de/cve201912815proftpd.html",
"refsource": "MISC",
"url": "https://tbspace.de/cve201912815proftpd.html"
},
{
"name": "http://bugs.proftpd.org/show_bug.cgi?id=4372",
"refsource": "MISC",
"url": "http://bugs.proftpd.org/show_bug.cgi?id=4372"
},
{
"name": "https://github.com/proftpd/proftpd/pull/816",
"refsource": "MISC",
"url": "https://github.com/proftpd/proftpd/pull/816"
},
{
"name": "109339",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/109339"
},
{
"name": "FEDORA-2019-82b0f48691",
"refsource": "FEDORA",
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/XM5FPBAGSIKV6YJZEPM6GPGJO5JFT7XU/"
},
{
"name": "FEDORA-2019-e9187610c3",
"refsource": "FEDORA",
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/OJDQ3XUYWO42TJBO53NUWDZRA35QMVEI/"
},
{
"name": "20190805 [SECURITY] [DSA 4491-1] proftpd-dfsg security update",
"refsource": "BUGTRAQ",
"url": "https://seclists.org/bugtraq/2019/Aug/3"
},
{
"name": "DSA-4491",
"refsource": "DEBIAN",
"url": "https://www.debian.org/security/2019/dsa-4491"
},
{
"name": "[debian-lts-announce] 20190807 [SECURITY] [DLA 1873-1] proftpd-dfsg security update",
"refsource": "MLIST",
"url": "https://lists.debian.org/debian-lts-announce/2019/08/msg00006.html"
},
{
"name": "openSUSE-SU-2019:1836",
"refsource": "SUSE",
"url": "http://lists.opensuse.org/opensuse-security-announce/2019-08/msg00004.html"
},
{
"name": "openSUSE-SU-2019:1870",
"refsource": "SUSE",
"url": "http://lists.opensuse.org/opensuse-security-announce/2019-08/msg00022.html"
},
{
"name": "GLSA-201908-16",
"refsource": "GENTOO",
"url": "https://security.gentoo.org/glsa/201908-16"
},
{
"name": "openSUSE-SU-2020:0031",
"refsource": "SUSE",
"url": "http://lists.opensuse.org/opensuse-security-announce/2020-01/msg00009.html"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940889.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940889.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-12815",
"datePublished": "2019-07-19T22:56:14",
"dateReserved": "2019-06-13T00:00:00",
"dateUpdated": "2024-08-04T23:32:55.303Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-13940 (GCVE-0-2019-13940)
Vulnerability from cvelistv5
Published
2020-02-11 15:36
Modified
2024-08-05 00:05
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-400 - Uncontrolled Resource Consumption
Summary
A vulnerability has been identified in SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions < V3.X.17), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.1), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 315-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 317-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 319-3 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions < V3.X.17), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX 2010 (All versions), SIMATIC WinAC RTX F 2010 (All versions), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions < V3.X.17), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions < V3.X.17), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions < V3.X.17), SIPLUS S7-300 CPU 315-2 PN/DP (All versions < V3.X.17), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions < V3.X.17), SIPLUS S7-300 CPU 317-2 PN/DP (All versions < V3.X.17), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions < V3.X.17). Affected devices contain a vulnerability that could cause a denial of service condition of the web server
by sending specially crafted HTTP requests to ports 80/tcp and 443/tcp.
Beyond the web service, no other functions or interfaces are affected by the denial of service condition.
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC ET 200pro IM154-8 PN/DP CPU |
Version: All versions < V3.X.17 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T00:05:44.018Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-431678.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM154-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM154-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM154-8FX PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200S IM151-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200S IM151-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 314C-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 319-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 319F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX F 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200S IM151-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200S IM151-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 314C-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 315-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 315F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 317-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 317F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions \u003c V3.X.17), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions \u003c V3.X.17), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions \u003c V3.X.17), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions \u003c V3.X.17), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions \u003c V3.X.17), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.1), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions \u003c V3.X.17), SIMATIC S7-300 CPU 315-2 PN/DP (All versions \u003c V3.X.17), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions \u003c V3.X.17), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions \u003c V3.X.17), SIMATIC S7-300 CPU 317-2 PN/DP (All versions \u003c V3.X.17), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions \u003c V3.X.17), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions \u003c V3.X.17), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions \u003c V3.X.17), SIMATIC S7-300 CPU 319-3 PN/DP (All versions \u003c V3.X.17), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions \u003c V3.X.17), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX 2010 (All versions), SIMATIC WinAC RTX F 2010 (All versions), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions \u003c V3.X.17), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions \u003c V3.X.17), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions \u003c V3.X.17), SIPLUS S7-300 CPU 315-2 PN/DP (All versions \u003c V3.X.17), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions \u003c V3.X.17), SIPLUS S7-300 CPU 317-2 PN/DP (All versions \u003c V3.X.17), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions \u003c V3.X.17). Affected devices contain a vulnerability that could cause a denial of service condition of the web server\r\nby sending specially crafted HTTP requests to ports 80/tcp and 443/tcp.\r\n\r\nBeyond the web service, no other functions or interfaces are affected by the denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-10T11:39:13.999Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-431678.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-13940",
"datePublished": "2020-02-11T15:36:10",
"dateReserved": "2019-07-18T00:00:00",
"dateUpdated": "2024-08-05T00:05:44.018Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-0169 (GCVE-0-2019-0169)
Vulnerability from cvelistv5
Published
2019-12-18 21:07
Modified
2024-08-04 17:44
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Escalation of Privilege, Denial of Service, Information Disclosure
Summary
Heap overflow in subsystem in Intel(R) CSME before versions 11.8.70, 11.11.70, 11.22.70, 12.0.45; Intel(R) TXE before versions 3.1.70 and 4.0.20 may allow an unauthenticated user to potentially enable escalation of privileges, information disclosure or denial of service via adjacent access.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) TXE |
Version: See provided reference |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T17:44:14.755Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00241.html"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-398519.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) TXE",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See provided reference"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Heap overflow in subsystem in Intel(R) CSME before versions 11.8.70, 11.11.70, 11.22.70, 12.0.45; Intel(R) TXE before versions 3.1.70 and 4.0.20 may allow an unauthenticated user to potentially enable escalation of privileges, information disclosure or denial of service via adjacent access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Escalation of Privilege, Denial of Service, Information Disclosure",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-11T11:06:01",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00241.html"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-398519.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2019-0169",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) TXE",
"version": {
"version_data": [
{
"version_value": "See provided reference"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Heap overflow in subsystem in Intel(R) CSME before versions 11.8.70, 11.11.70, 11.22.70, 12.0.45; Intel(R) TXE before versions 3.1.70 and 4.0.20 may allow an unauthenticated user to potentially enable escalation of privileges, information disclosure or denial of service via adjacent access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Escalation of Privilege, Denial of Service, Information Disclosure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00241.html",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00241.html"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-398519.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-398519.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2019-0169",
"datePublished": "2019-12-18T21:07:38",
"dateReserved": "2018-11-13T00:00:00",
"dateUpdated": "2024-08-04T17:44:14.755Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-19282 (GCVE-0-2019-19282)
Vulnerability from cvelistv5
Published
2020-03-10 19:16
Modified
2024-08-05 02:09
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-131 - Incorrect Calculation of Buffer Size
Summary
A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions < V8.2 Upd12), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions < V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions < V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition.
Successful exploitation requires no system privileges and no user interaction.
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | OpenPCS 7 V8.1 |
Version: All versions |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:09:39.657Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-270778.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "OpenPCS 7 V8.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "OpenPCS 7 V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "OpenPCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.0 Upd3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC BATCH V8.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC BATCH V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.2 Upd12"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC BATCH V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.0 SP1 Upd5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC NET PC Software V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 14"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC NET PC Software V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC NET PC Software V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V8.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.0 SP3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Route Control V8.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Route Control V8.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Route Control V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.0 Upd4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC (TIA Portal) V13",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13 SP2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC (TIA Portal) V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 10"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC (TIA Portal) V15.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC (TIA Portal) V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Update 14"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 SP1 Update 1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions \u003c V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions \u003c V8.2 Upd12), SIMATIC BATCH V9.0 (All versions \u003c V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions \u003c V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions \u003c V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions \u003c V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition.\nSuccessful exploitation requires no system privileges and no user interaction."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-131",
"description": "CWE-131: Incorrect Calculation of Buffer Size",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T09:01:49.748Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-270778.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-19282",
"datePublished": "2020-03-10T19:16:17",
"dateReserved": "2019-11-26T00:00:00",
"dateUpdated": "2024-08-05T02:09:39.657Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-19279 (GCVE-0-2019-19279)
Vulnerability from cvelistv5
Published
2020-03-10 19:16
Modified
2024-08-05 02:09
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-20 - Improper Input Validation
Summary
A vulnerability has been identified in SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modules (All versions). Specially crafted packets sent to port 50000/UDP of the EN100 Ethernet communication modules could cause a Denial-of-Service of the affected device. A manual reboot is required to recover the service of the device. At the time of advisory publication no public exploitation of this security vulnerability was known to Siemens.
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens AG | SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modules |
Version: All versions |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:09:39.609Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-974843.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modules",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modules (All versions). Specially crafted packets sent to port 50000/UDP of the EN100 Ethernet communication modules could cause a Denial-of-Service of the affected device. A manual reboot is required to recover the service of the device. At the time of advisory publication no public exploitation of this security vulnerability was known to Siemens."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-03-10T19:16:17",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-974843.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-19279",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modules",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modules (All versions). Specially crafted packets sent to port 50000/UDP of the EN100 Ethernet communication modules could cause a Denial-of-Service of the affected device. A manual reboot is required to recover the service of the device. At the time of advisory publication no public exploitation of this security vulnerability was known to Siemens."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20: Improper Input Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-974843.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-974843.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-19279",
"datePublished": "2020-03-10T19:16:17",
"dateReserved": "2019-11-26T00:00:00",
"dateUpdated": "2024-08-05T02:09:39.609Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-13925 (GCVE-0-2019-13925)
Vulnerability from cvelistv5
Published
2020-02-11 15:36
Modified
2024-08-05 00:05
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-400 - Uncontrolled Resource Consumption
Summary
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SCALANCE S602 |
Version: All versions >= V3.0 and < V4.1 |
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T00:05:43.784Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SCALANCE S602",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
},
{
"product": "SCALANCE S612",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
},
{
"product": "SCALANCE S623",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
},
{
"product": "SCALANCE S627-2M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-22T20:42:18",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-13925",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SCALANCE S602",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
}
},
{
"product_name": "SCALANCE S612",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
}
},
{
"product_name": "SCALANCE S623",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
}
},
{
"product_name": "SCALANCE S627-2M",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400: Uncontrolled Resource Consumption"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-13925",
"datePublished": "2020-02-11T15:36:10",
"dateReserved": "2019-07-18T00:00:00",
"dateUpdated": "2024-08-05T00:05:43.784Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-13941 (GCVE-0-2019-13941)
Vulnerability from cvelistv5
Published
2020-02-11 15:36
Modified
2024-08-05 00:05
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-552 - Files or Directories Accessible to External Parties
Summary
A vulnerability has been identified in OZW672 (All versions < V10.00), OZW772 (All versions < V10.00). Vulnerable versions of OZW Web Server use predictable path names for project files that legitimately authenticated users have created by using the application's export function. By accessing a specific uniform resource locator on the web server, a remote attacker could be able to download a project file without prior authentication. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected system. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens AG | OZW672 |
Version: All versions < V10.00 |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T00:05:43.901Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-986695.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-09"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "OZW672",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V10.00"
}
]
},
{
"product": "OZW772",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V10.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in OZW672 (All versions \u003c V10.00), OZW772 (All versions \u003c V10.00). Vulnerable versions of OZW Web Server use predictable path names for project files that legitimately authenticated users have created by using the application\u0027s export function. By accessing a specific uniform resource locator on the web server, a remote attacker could be able to download a project file without prior authentication. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected system. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-552",
"description": "CWE-552: Files or Directories Accessible to External Parties",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-03-10T19:16:14",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-986695.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-09"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-13941",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "OZW672",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V10.00"
}
]
}
},
{
"product_name": "OZW772",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V10.00"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in OZW672 (All versions \u003c V10.00), OZW772 (All versions \u003c V10.00). Vulnerable versions of OZW Web Server use predictable path names for project files that legitimately authenticated users have created by using the application\u0027s export function. By accessing a specific uniform resource locator on the web server, a remote attacker could be able to download a project file without prior authentication. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected system. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-552: Files or Directories Accessible to External Parties"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-986695.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-986695.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-09",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-09"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-13941",
"datePublished": "2020-02-11T15:36:10",
"dateReserved": "2019-07-18T00:00:00",
"dateUpdated": "2024-08-05T00:05:43.901Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-13946 (GCVE-0-2019-13946)
Vulnerability from cvelistv5
Published
2020-02-11 15:36
Modified
2024-08-05 00:05
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-400 - Uncontrolled Resource Consumption
Summary
Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit
internal resource allocation when multiple legitimate diagnostic package
requests are sent to the DCE-RPC interface.
This could lead to a denial of service condition due to lack of memory
for devices that include a vulnerable version of the stack.
The security vulnerability could be exploited by an attacker with network
access to an affected device. Successful exploitation requires no system
privileges and no user interaction. An attacker could use the vulnerability
to compromise the availability of the device.
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
Version: 0 < * |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2019-13946",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T18:06:01.358486Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T18:06:09.778Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-05T00:05:44.023Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-780073.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-780073.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V4.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V4.6"
}
]
},
{
"defaultStatus": "unknown",
"product": "PROFINET Driver for Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RM1224 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M804PB",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M812-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M816-1 ADSL-Router",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M826-2 SHDSL-Router",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M874-3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-3 (ROK)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (EU)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M876-4 (NAM)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE S615 LAN-Router",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W-700 IEEE 802.11n family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c= V6.0.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X200-4P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V5.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X201-3P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V5.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X201-3P IRT PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V5.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X202-2IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V5.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X202-2P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V5.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X202-2P IRT PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V5.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X204-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X204-2FM",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X204-2LD",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X204-2LD TS",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X204-2TS",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X204IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V5.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X204IRT PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V5.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X206-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X206-1LD",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X208PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X212-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X212-2LD",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X216",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X224",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (230V, coated)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (24V, coated)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (2x 230V, coated)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (2x 230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (2x 24V, coated)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X302-7 EEC (2x 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X304-2FE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X306-1LD FE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (230V, coated)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (24V, coated)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (2x 230V, coated)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (2x 230V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (2x 24V, coated)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-2 EEC (2x 24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-3",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-3LD",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X307-3LD",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LD",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LD",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LH",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LH",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LH+",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2LH+",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M PoE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M TS",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X308-2M TS",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X310",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X310",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X310FE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X310FE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X320-1 FE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X320-1-2LD FE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X408-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XB-200 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XC-200",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF-200BA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF201-3P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V5.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF202-2P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V5.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V5.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V5.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF206-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM-400 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V6.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XP-200",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR-300WG family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR-500 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V6.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (230V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (230V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (230V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (230V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M TS (24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-12M TS (24V)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (230V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1616 and CP 1604",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V2.8"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 ERPC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 Lean",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 OPC UA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200AL IM 157-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200M IM 153-4 PN IO HF (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200M IM 153-4 PN IO ST (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-3 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-4 PN HF",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN: IO-Link Master",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200S (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC Support, Package for VxWorks",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-B",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-B Body",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-P Body",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV440 HR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV440 SR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV440 UR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF180C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF182C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF600R family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION D",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION P",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS DCP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V1.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 343-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 343-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 343-1 Lean",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 443-1 Advanced",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE X308-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOFTNET-IE PNIO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit\ninternal resource allocation when multiple legitimate diagnostic package\nrequests are sent to the DCE-RPC interface.\nThis could lead to a denial of service condition due to lack of memory\nfor devices that include a vulnerable version of the stack.\n\nThe security vulnerability could be exploited by an attacker with network\naccess to an affected device. Successful exploitation requires no system\nprivileges and no user interaction. An attacker could use the vulnerability\nto compromise the availability of the device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T12:03:58.088Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-780073.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-780073.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-13946",
"datePublished": "2020-02-11T15:36:10",
"dateReserved": "2019-07-18T00:00:00",
"dateUpdated": "2024-08-05T00:05:44.023Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-19281 (GCVE-0-2019-19281)
Vulnerability from cvelistv5
Published
2020-03-10 19:16
Modified
2024-08-05 02:09
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-400 - Uncontrolled Resource Consumption ('Resource Exhaustion')
Summary
A vulnerability has been identified in SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V2.5 and < V20.8), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 and < V2.8), SIMATIC S7-1500 Software Controller (All versions >= V2.5 and < V20.8). Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a Denial-of-Service condition. The vulnerability can be triggered if specially crafted UDP packets are sent to the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the device availability.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens AG | SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) |
Version: All versions >= V2.5 and < V20.8 |
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:09:39.528Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-750824.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-11"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.5 and \u003c V20.8"
}
]
},
{
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.5 and \u003c V2.8"
}
]
},
{
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.5 and \u003c V20.8"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V2.5 and \u003c V20.8), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.5 and \u003c V2.8), SIMATIC S7-1500 Software Controller (All versions \u003e= V2.5 and \u003c V20.8). Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a Denial-of-Service condition. The vulnerability can be triggered if specially crafted UDP packets are sent to the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the device availability."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption (\u0027Resource Exhaustion\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-02T21:49:46",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-750824.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-11"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-19281",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V2.5 and \u003c V20.8"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V2.5 and \u003c V2.8"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 Software Controller",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V2.5 and \u003c V20.8"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V2.5 and \u003c V20.8), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.5 and \u003c V2.8), SIMATIC S7-1500 Software Controller (All versions \u003e= V2.5 and \u003c V20.8). Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a Denial-of-Service condition. The vulnerability can be triggered if specially crafted UDP packets are sent to the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the device availability."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400: Uncontrolled Resource Consumption (\u0027Resource Exhaustion\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-750824.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-750824.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-11",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-11"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-19281",
"datePublished": "2020-03-10T19:16:17",
"dateReserved": "2019-11-26T00:00:00",
"dateUpdated": "2024-08-05T02:09:39.528Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-0152 (GCVE-0-2019-0152)
Vulnerability from cvelistv5
Published
2019-11-14 19:06
Modified
2024-08-04 17:44
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Escalation of Privilege
Summary
Insufficient memory protection in System Management Mode (SMM) and Intel(R) TXT for certain Intel(R) Xeon(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access.
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | 2019.2 IPU – Intel(R) Processor Security |
Version: See provided reference |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T17:44:14.767Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00240.html"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03971en_us"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.f5.com/csp/article/K34425791?utm_source=f5support\u0026amp%3Butm_medium=RSS"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-398519.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "2019.2 IPU \u2013 Intel(R) Processor Security",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See provided reference"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insufficient memory protection in System Management Mode (SMM) and Intel(R) TXT for certain Intel(R) Xeon(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Escalation of Privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-11T11:06:03",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00240.html"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03971en_us"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.f5.com/csp/article/K34425791?utm_source=f5support\u0026amp%3Butm_medium=RSS"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-398519.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"ID": "CVE-2019-0152",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "2019.2 IPU \u2013 Intel(R) Processor Security",
"version": {
"version_data": [
{
"version_value": "See provided reference"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Insufficient memory protection in System Management Mode (SMM) and Intel(R) TXT for certain Intel(R) Xeon(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Escalation of Privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00240.html",
"refsource": "MISC",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00240.html"
},
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03971en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03971en_us"
},
{
"name": "https://support.f5.com/csp/article/K34425791?utm_source=f5support\u0026amp;utm_medium=RSS",
"refsource": "CONFIRM",
"url": "https://support.f5.com/csp/article/K34425791?utm_source=f5support\u0026amp;utm_medium=RSS"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-398519.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-398519.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2019-0152",
"datePublished": "2019-11-14T19:06:54",
"dateReserved": "2018-11-13T00:00:00",
"dateUpdated": "2024-08-04T17:44:14.767Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-18217 (GCVE-0-2019-18217)
Vulnerability from cvelistv5
Published
2019-10-21 03:12
Modified
2024-08-05 01:47
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
ProFTPD before 1.3.6b and 1.3.7rc before 1.3.7rc2 allows remote unauthenticated denial-of-service due to incorrect handling of overly long commands because main.c in a child process enters an infinite loop.
References
| URL | Tags | |||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T01:47:13.989Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/proftpd/proftpd/issues/846"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/proftpd/proftpd/blob/master/RELEASE_NOTES"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/proftpd/proftpd/blob/1.3.6/RELEASE_NOTES"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/proftpd/proftpd/blob/master/NEWS"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/proftpd/proftpd/blob/1.3.6/NEWS"
},
{
"name": "[debian-lts-announce] 20191027 [SECURITY] [DLA 1974-1] proftpd-dfsg security update",
"tags": [
"mailing-list",
"x_refsource_MLIST",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2019/10/msg00036.html"
},
{
"name": "FEDORA-2019-ae019c7e9f",
"tags": [
"vendor-advisory",
"x_refsource_FEDORA",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/NJDQRVZTILBX4BUCTIRKP2WBHDHDCJR5/"
},
{
"name": "FEDORA-2019-848e410cfb",
"tags": [
"vendor-advisory",
"x_refsource_FEDORA",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/YLRPYEEMQJVAXO2SXRGOQ4HBFEEPCNXG/"
},
{
"name": "FEDORA-2019-7559f29ace",
"tags": [
"vendor-advisory",
"x_refsource_FEDORA",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/RB2FPAWDWXT5ALAFIC5Y3RSEMXSFL6H2/"
},
{
"name": "20191106 [SECURITY] [DSA 4559-1] proftpd-dfsg security update",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ",
"x_transferred"
],
"url": "https://seclists.org/bugtraq/2019/Nov/7"
},
{
"name": "DSA-4559",
"tags": [
"vendor-advisory",
"x_refsource_DEBIAN",
"x_transferred"
],
"url": "https://www.debian.org/security/2019/dsa-4559"
},
{
"name": "openSUSE-SU-2020:0031",
"tags": [
"vendor-advisory",
"x_refsource_SUSE",
"x_transferred"
],
"url": "http://lists.opensuse.org/opensuse-security-announce/2020-01/msg00009.html"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940889.pdf"
},
{
"name": "GLSA-202003-35",
"tags": [
"vendor-advisory",
"x_refsource_GENTOO",
"x_transferred"
],
"url": "https://security.gentoo.org/glsa/202003-35"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "ProFTPD before 1.3.6b and 1.3.7rc before 1.3.7rc2 allows remote unauthenticated denial-of-service due to incorrect handling of overly long commands because main.c in a child process enters an infinite loop."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-03-16T22:06:08",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/proftpd/proftpd/issues/846"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/proftpd/proftpd/blob/master/RELEASE_NOTES"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/proftpd/proftpd/blob/1.3.6/RELEASE_NOTES"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/proftpd/proftpd/blob/master/NEWS"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/proftpd/proftpd/blob/1.3.6/NEWS"
},
{
"name": "[debian-lts-announce] 20191027 [SECURITY] [DLA 1974-1] proftpd-dfsg security update",
"tags": [
"mailing-list",
"x_refsource_MLIST"
],
"url": "https://lists.debian.org/debian-lts-announce/2019/10/msg00036.html"
},
{
"name": "FEDORA-2019-ae019c7e9f",
"tags": [
"vendor-advisory",
"x_refsource_FEDORA"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/NJDQRVZTILBX4BUCTIRKP2WBHDHDCJR5/"
},
{
"name": "FEDORA-2019-848e410cfb",
"tags": [
"vendor-advisory",
"x_refsource_FEDORA"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/YLRPYEEMQJVAXO2SXRGOQ4HBFEEPCNXG/"
},
{
"name": "FEDORA-2019-7559f29ace",
"tags": [
"vendor-advisory",
"x_refsource_FEDORA"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/RB2FPAWDWXT5ALAFIC5Y3RSEMXSFL6H2/"
},
{
"name": "20191106 [SECURITY] [DSA 4559-1] proftpd-dfsg security update",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ"
],
"url": "https://seclists.org/bugtraq/2019/Nov/7"
},
{
"name": "DSA-4559",
"tags": [
"vendor-advisory",
"x_refsource_DEBIAN"
],
"url": "https://www.debian.org/security/2019/dsa-4559"
},
{
"name": "openSUSE-SU-2020:0031",
"tags": [
"vendor-advisory",
"x_refsource_SUSE"
],
"url": "http://lists.opensuse.org/opensuse-security-announce/2020-01/msg00009.html"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940889.pdf"
},
{
"name": "GLSA-202003-35",
"tags": [
"vendor-advisory",
"x_refsource_GENTOO"
],
"url": "https://security.gentoo.org/glsa/202003-35"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-18217",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "ProFTPD before 1.3.6b and 1.3.7rc before 1.3.7rc2 allows remote unauthenticated denial-of-service due to incorrect handling of overly long commands because main.c in a child process enters an infinite loop."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/proftpd/proftpd/issues/846",
"refsource": "MISC",
"url": "https://github.com/proftpd/proftpd/issues/846"
},
{
"name": "https://github.com/proftpd/proftpd/blob/master/RELEASE_NOTES",
"refsource": "MISC",
"url": "https://github.com/proftpd/proftpd/blob/master/RELEASE_NOTES"
},
{
"name": "https://github.com/proftpd/proftpd/blob/1.3.6/RELEASE_NOTES",
"refsource": "MISC",
"url": "https://github.com/proftpd/proftpd/blob/1.3.6/RELEASE_NOTES"
},
{
"name": "https://github.com/proftpd/proftpd/blob/master/NEWS",
"refsource": "MISC",
"url": "https://github.com/proftpd/proftpd/blob/master/NEWS"
},
{
"name": "https://github.com/proftpd/proftpd/blob/1.3.6/NEWS",
"refsource": "MISC",
"url": "https://github.com/proftpd/proftpd/blob/1.3.6/NEWS"
},
{
"name": "[debian-lts-announce] 20191027 [SECURITY] [DLA 1974-1] proftpd-dfsg security update",
"refsource": "MLIST",
"url": "https://lists.debian.org/debian-lts-announce/2019/10/msg00036.html"
},
{
"name": "FEDORA-2019-ae019c7e9f",
"refsource": "FEDORA",
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/NJDQRVZTILBX4BUCTIRKP2WBHDHDCJR5/"
},
{
"name": "FEDORA-2019-848e410cfb",
"refsource": "FEDORA",
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/YLRPYEEMQJVAXO2SXRGOQ4HBFEEPCNXG/"
},
{
"name": "FEDORA-2019-7559f29ace",
"refsource": "FEDORA",
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/RB2FPAWDWXT5ALAFIC5Y3RSEMXSFL6H2/"
},
{
"name": "20191106 [SECURITY] [DSA 4559-1] proftpd-dfsg security update",
"refsource": "BUGTRAQ",
"url": "https://seclists.org/bugtraq/2019/Nov/7"
},
{
"name": "DSA-4559",
"refsource": "DEBIAN",
"url": "https://www.debian.org/security/2019/dsa-4559"
},
{
"name": "openSUSE-SU-2020:0031",
"refsource": "SUSE",
"url": "http://lists.opensuse.org/opensuse-security-announce/2020-01/msg00009.html"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940889.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940889.pdf"
},
{
"name": "GLSA-202003-35",
"refsource": "GENTOO",
"url": "https://security.gentoo.org/glsa/202003-35"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-18217",
"datePublished": "2019-10-21T03:12:31",
"dateReserved": "2019-10-21T00:00:00",
"dateUpdated": "2024-08-05T01:47:13.989Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-19282 (GCVE-0-2020-19282)
Vulnerability from cvelistv5
Published
2021-09-09 22:10
Modified
2024-08-04 14:08
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A reflected cross-site scripting (XSS) vulnerability in Jeesns 1.4.2 allows attackers to execute arbitrary web scripts or HTML via a crafted payload in the system error message's text field.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T14:08:30.658Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.seebug.org/vuldb/ssvid-97940"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/zchuanzhao/jeesns/issues/11"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A reflected cross-site scripting (XSS) vulnerability in Jeesns 1.4.2 allows attackers to execute arbitrary web scripts or HTML via a crafted payload in the system error message\u0027s text field."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-09-09T22:10:34",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.seebug.org/vuldb/ssvid-97940"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/zchuanzhao/jeesns/issues/11"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-19282",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A reflected cross-site scripting (XSS) vulnerability in Jeesns 1.4.2 allows attackers to execute arbitrary web scripts or HTML via a crafted payload in the system error message\u0027s text field."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.seebug.org/vuldb/ssvid-97940",
"refsource": "MISC",
"url": "https://www.seebug.org/vuldb/ssvid-97940"
},
{
"name": "https://github.com/zchuanzhao/jeesns/issues/11",
"refsource": "MISC",
"url": "https://github.com/zchuanzhao/jeesns/issues/11"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-19282",
"datePublished": "2021-09-09T22:10:34",
"dateReserved": "2020-08-13T00:00:00",
"dateUpdated": "2024-08-04T14:08:30.658Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6585 (GCVE-0-2019-6585)
Vulnerability from cvelistv5
Published
2020-03-10 19:16
Modified
2024-08-04 20:23
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
Summary
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SCALANCE S602 |
Version: All versions >= V3.0 and < V4.1 |
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:23:22.461Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SCALANCE S602",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
},
{
"product": "SCALANCE S612",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
},
{
"product": "SCALANCE S623",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
},
{
"product": "SCALANCE S627-2M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-80",
"description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-22T20:42:19",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-6585",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SCALANCE S602",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
}
},
{
"product_name": "SCALANCE S612",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
}
},
{
"product_name": "SCALANCE S623",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
}
},
{
"product_name": "SCALANCE S627-2M",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-6585",
"datePublished": "2020-03-10T19:16:17",
"dateReserved": "2019-01-22T00:00:00",
"dateUpdated": "2024-08-04T20:23:22.461Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-5621 (GCVE-0-2015-5621)
Vulnerability from cvelistv5
Published
2015-08-19 15:00
Modified
2024-08-06 06:59
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
The snmp_pdu_parse function in snmp_api.c in net-snmp 5.7.2 and earlier does not remove the varBind variable in a netsnmp_variable_list item when parsing of the SNMP PDU fails, which allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a crafted packet.
References
| URL | Tags | ||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T06:59:02.679Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "openSUSE-SU-2015:1502",
"tags": [
"vendor-advisory",
"x_refsource_SUSE",
"x_transferred"
],
"url": "http://lists.opensuse.org/opensuse-updates/2015-09/msg00004.html"
},
{
"name": "45547",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB",
"x_transferred"
],
"url": "https://www.exploit-db.com/exploits/45547/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://sourceforge.net/p/net-snmp/code/ci/f23bcd3ac6ddee5d0a48f9703007ccc738914791/"
},
{
"name": "RHSA-2015:1636",
"tags": [
"vendor-advisory",
"x_refsource_REDHAT",
"x_transferred"
],
"url": "http://rhn.redhat.com/errata/RHSA-2015-1636.html"
},
{
"name": "1033304",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1033304"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=1212408"
},
{
"name": "USN-2711-1",
"tags": [
"vendor-advisory",
"x_refsource_UBUNTU",
"x_transferred"
],
"url": "http://www.ubuntu.com/usn/USN-2711-1"
},
{
"name": "[oss-security] 20150416 Re: net-snmp snmp_pdu_parse() function incompletely initializaition vulnerability",
"tags": [
"mailing-list",
"x_refsource_MLIST",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2015/04/16/15"
},
{
"name": "[oss-security] 20150413 net-snmp snmp_pdu_parse() function incompletely initializaition vulnerability",
"tags": [
"mailing-list",
"x_refsource_MLIST",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2015/04/13/1"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://support.citrix.com/article/CTX209443"
},
{
"name": "DSA-4154",
"tags": [
"vendor-advisory",
"x_refsource_DEBIAN",
"x_transferred"
],
"url": "https://www.debian.org/security/2018/dsa-4154"
},
{
"name": "[oss-security] 20150731 Re: net-snmp snmp_pdu_parse() function incompletely initializaition vulnerability",
"tags": [
"mailing-list",
"x_refsource_MLIST",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2015/07/31/1"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://sourceforge.net/p/net-snmp/bugs/2615/"
},
{
"name": "76380",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/76380"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-978220.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2015-04-13T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The snmp_pdu_parse function in snmp_api.c in net-snmp 5.7.2 and earlier does not remove the varBind variable in a netsnmp_variable_list item when parsing of the SNMP PDU fails, which allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a crafted packet."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-11T10:06:22",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "openSUSE-SU-2015:1502",
"tags": [
"vendor-advisory",
"x_refsource_SUSE"
],
"url": "http://lists.opensuse.org/opensuse-updates/2015-09/msg00004.html"
},
{
"name": "45547",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB"
],
"url": "https://www.exploit-db.com/exploits/45547/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://sourceforge.net/p/net-snmp/code/ci/f23bcd3ac6ddee5d0a48f9703007ccc738914791/"
},
{
"name": "RHSA-2015:1636",
"tags": [
"vendor-advisory",
"x_refsource_REDHAT"
],
"url": "http://rhn.redhat.com/errata/RHSA-2015-1636.html"
},
{
"name": "1033304",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1033304"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=1212408"
},
{
"name": "USN-2711-1",
"tags": [
"vendor-advisory",
"x_refsource_UBUNTU"
],
"url": "http://www.ubuntu.com/usn/USN-2711-1"
},
{
"name": "[oss-security] 20150416 Re: net-snmp snmp_pdu_parse() function incompletely initializaition vulnerability",
"tags": [
"mailing-list",
"x_refsource_MLIST"
],
"url": "http://www.openwall.com/lists/oss-security/2015/04/16/15"
},
{
"name": "[oss-security] 20150413 net-snmp snmp_pdu_parse() function incompletely initializaition vulnerability",
"tags": [
"mailing-list",
"x_refsource_MLIST"
],
"url": "http://www.openwall.com/lists/oss-security/2015/04/13/1"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://support.citrix.com/article/CTX209443"
},
{
"name": "DSA-4154",
"tags": [
"vendor-advisory",
"x_refsource_DEBIAN"
],
"url": "https://www.debian.org/security/2018/dsa-4154"
},
{
"name": "[oss-security] 20150731 Re: net-snmp snmp_pdu_parse() function incompletely initializaition vulnerability",
"tags": [
"mailing-list",
"x_refsource_MLIST"
],
"url": "http://www.openwall.com/lists/oss-security/2015/07/31/1"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://sourceforge.net/p/net-snmp/bugs/2615/"
},
{
"name": "76380",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/76380"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-978220.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2015-5621",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The snmp_pdu_parse function in snmp_api.c in net-snmp 5.7.2 and earlier does not remove the varBind variable in a netsnmp_variable_list item when parsing of the SNMP PDU fails, which allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a crafted packet."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "openSUSE-SU-2015:1502",
"refsource": "SUSE",
"url": "http://lists.opensuse.org/opensuse-updates/2015-09/msg00004.html"
},
{
"name": "45547",
"refsource": "EXPLOIT-DB",
"url": "https://www.exploit-db.com/exploits/45547/"
},
{
"name": "http://sourceforge.net/p/net-snmp/code/ci/f23bcd3ac6ddee5d0a48f9703007ccc738914791/",
"refsource": "CONFIRM",
"url": "http://sourceforge.net/p/net-snmp/code/ci/f23bcd3ac6ddee5d0a48f9703007ccc738914791/"
},
{
"name": "RHSA-2015:1636",
"refsource": "REDHAT",
"url": "http://rhn.redhat.com/errata/RHSA-2015-1636.html"
},
{
"name": "1033304",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1033304"
},
{
"name": "https://bugzilla.redhat.com/show_bug.cgi?id=1212408",
"refsource": "CONFIRM",
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=1212408"
},
{
"name": "USN-2711-1",
"refsource": "UBUNTU",
"url": "http://www.ubuntu.com/usn/USN-2711-1"
},
{
"name": "[oss-security] 20150416 Re: net-snmp snmp_pdu_parse() function incompletely initializaition vulnerability",
"refsource": "MLIST",
"url": "http://www.openwall.com/lists/oss-security/2015/04/16/15"
},
{
"name": "[oss-security] 20150413 net-snmp snmp_pdu_parse() function incompletely initializaition vulnerability",
"refsource": "MLIST",
"url": "http://www.openwall.com/lists/oss-security/2015/04/13/1"
},
{
"name": "http://support.citrix.com/article/CTX209443",
"refsource": "CONFIRM",
"url": "http://support.citrix.com/article/CTX209443"
},
{
"name": "DSA-4154",
"refsource": "DEBIAN",
"url": "https://www.debian.org/security/2018/dsa-4154"
},
{
"name": "[oss-security] 20150731 Re: net-snmp snmp_pdu_parse() function incompletely initializaition vulnerability",
"refsource": "MLIST",
"url": "http://www.openwall.com/lists/oss-security/2015/07/31/1"
},
{
"name": "https://sourceforge.net/p/net-snmp/bugs/2615/",
"refsource": "CONFIRM",
"url": "https://sourceforge.net/p/net-snmp/bugs/2615/"
},
{
"name": "76380",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/76380"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-978220.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-978220.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2015-5621",
"datePublished": "2015-08-19T15:00:00",
"dateReserved": "2015-07-22T00:00:00",
"dateUpdated": "2024-08-06T06:59:02.679Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-13924 (GCVE-0-2019-13924)
Vulnerability from cvelistv5
Published
2020-02-11 00:00
Modified
2024-08-05 00:05
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-693 - Protection Mechanism Failure
Summary
A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SCALANCE S602 |
Version: All versions < V4.1 |
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T00:05:43.919Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-951513.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-07"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SCALANCE S602",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1"
}
]
},
{
"product": "SCALANCE S612",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1"
}
]
},
{
"product": "SCALANCE S623",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1"
}
]
},
{
"product": "SCALANCE S627-2M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1"
}
]
},
{
"product": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 5.2.4"
}
]
},
{
"product": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE X-200RNA switch family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.7"
}
]
},
{
"product": "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 4.1.3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003c V4.1), SCALANCE S612 (All versions \u003c V4.1), SCALANCE S623 (All versions \u003c V4.1), SCALANCE S627-2M (All versions \u003c V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-200RNA switch family (All versions \u003c V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-693",
"description": "CWE-693: Protection Mechanism Failure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-13T00:00:00",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-951513.pdf"
},
{
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-07"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-13924",
"datePublished": "2020-02-11T00:00:00",
"dateReserved": "2019-07-18T00:00:00",
"dateUpdated": "2024-08-05T00:05:43.919Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-19277 (GCVE-0-2019-19277)
Vulnerability from cvelistv5
Published
2020-03-10 19:16
Modified
2024-08-05 02:09
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-778 - Insufficient Logging
Summary
A vulnerability has been identified in SIPORT MP (All versions < 3.1.4). Vulnerable versions of the device allow the creation of special accounts ("service users") with administrative privileges that could enable a remote authenticated attacker to perform actions that are not visible to other users of the system, such as granting persons access to a secured area.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens AG | SIPORT MP |
Version: All versions < 3.1.4 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:09:39.511Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-978558.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-08"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIPORT MP",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 3.1.4"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIPORT MP (All versions \u003c 3.1.4). Vulnerable versions of the device allow the creation of special accounts (\"service users\") with administrative privileges that could enable a remote authenticated attacker to perform actions that are not visible to other users of the system, such as granting persons access to a secured area."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-778",
"description": "CWE-778: Insufficient Logging",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-03-30T17:26:16",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-978558.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-08"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-19277",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIPORT MP",
"version": {
"version_data": [
{
"version_value": "All versions \u003c 3.1.4"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIPORT MP (All versions \u003c 3.1.4). Vulnerable versions of the device allow the creation of special accounts (\"service users\") with administrative privileges that could enable a remote authenticated attacker to perform actions that are not visible to other users of the system, such as granting persons access to a secured area."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-778: Insufficient Logging"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-978558.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-978558.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-08",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-08"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-19277",
"datePublished": "2020-03-10T19:16:17",
"dateReserved": "2019-11-26T00:00:00",
"dateUpdated": "2024-08-05T02:09:39.511Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-13926 (GCVE-0-2019-13926)
Vulnerability from cvelistv5
Published
2020-02-11 15:36
Modified
2024-08-05 00:05
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-400 - Uncontrolled Resource Consumption
Summary
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SCALANCE S602 |
Version: All versions >= V3.0 and < V4.1 |
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T00:05:43.805Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SCALANCE S602",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
},
{
"product": "SCALANCE S612",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
},
{
"product": "SCALANCE S623",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
},
{
"product": "SCALANCE S627-2M",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-22T20:42:18",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-13926",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SCALANCE S602",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
}
},
{
"product_name": "SCALANCE S612",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
}
},
{
"product_name": "SCALANCE S623",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
}
},
{
"product_name": "SCALANCE S627-2M",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V3.0 and \u003c V4.1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400: Uncontrolled Resource Consumption"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-13926",
"datePublished": "2020-02-11T15:36:10",
"dateReserved": "2019-07-18T00:00:00",
"dateUpdated": "2024-08-05T00:05:43.805Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…