CERTFR-2018-AVI-376
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans SCADA les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneImpacted products
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SIMATIC STEP 7 (TIA Portal) et WinCC (TIA Portal) V14 versions antérieures à V14 SP1 Update 6 | ||
| Siemens | N/A | Automation License Manager 5 versions antérieures à V5.3.4.4 | ||
| Siemens | N/A | Sinumerik Integrate Access MyMachine versions antérieures à V4.1.8 | ||
| Siemens | N/A | SINUMERIK Integrate Operate Client versions antérieures à V2.0.12 ou V3.0.12 | ||
| Siemens | N/A | SIMATIC STEP 7 (TIA Portal) et WinCC (TIAPortal) V15 versions antérieures à V15 Update 2 | ||
| Siemens | N/A | Automation License Manager 6 versions antérieures à V6.0.1 |
References
| Title | Publication Time | Tags | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SIMATIC STEP 7 (TIA Portal) et WinCC (TIA Portal) V14 versions ant\u00e9rieures \u00e0 V14 SP1 Update 6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Automation License Manager 5 versions ant\u00e9rieures \u00e0 V5.3.4.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Sinumerik Integrate Access MyMachine versions ant\u00e9rieures \u00e0 V4.1.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK Integrate Operate Client versions ant\u00e9rieures \u00e0 V2.0.12 ou V3.0.12",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC STEP 7 (TIA Portal) et WinCC (TIAPortal) V15 versions ant\u00e9rieures \u00e0 V15 Update 2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Automation License Manager 6 versions ant\u00e9rieures \u00e0 V6.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2018-11453",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-11453"
},
{
"name": "CVE-2017-3737",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-3737"
},
{
"name": "CVE-2018-11456",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-11456"
},
{
"name": "CVE-2018-11455",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-11455"
},
{
"name": "CVE-2018-11454",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-11454"
}
],
"initial_release_date": "2018-08-07T00:00:00",
"last_revision_date": "2018-08-07T00:00:00",
"links": [],
"reference": "CERTFR-2018-AVI-376",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2018-08-07T00:00:00.000000"
}
],
"risks": [
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "D\u00e9ni de service"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans SCADA les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service et une\natteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans SCADA les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 SCADA Siemens ssa-179516 du 07 ao\u00fbt 2018",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-179516.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 SCADA Siemens ssa-920962 du 07 ao\u00fbt 2018",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-920962.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 SCADA Siemens ssa-979106 du 07 ao\u00fbt 2018",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979106.pdf"
}
]
}
CVE-2018-11455 (GCVE-0-2018-11455)
Vulnerability from cvelistv5
Published
2018-08-07 15:00
Modified
2024-08-05 08:10
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Summary
A vulnerability has been identified in Automation License Manager 5 (All versions < 5.3.4.4), Automation License Manager 6 (All versions < 6.0.1). A directory traversal vulnerability could allow a remote attacker to move arbitrary files, which can result in code execution, compromising confidentiality, integrity and availability of the system. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges or special conditions of the system, but user interaction is required.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens AG | Automation License Manager 5, Automation License Manager 6 |
Version: Automation License Manager 5 : All versions < 5.3.4.4 Version: Automation License Manager 6 : All versions < 6.0.1 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T08:10:14.446Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "105114",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105114"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-920962.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Automation License Manager 5, Automation License Manager 6",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "Automation License Manager 5 : All versions \u003c 5.3.4.4"
},
{
"status": "affected",
"version": "Automation License Manager 6 : All versions \u003c 6.0.1"
}
]
}
],
"datePublic": "2018-08-07T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Automation License Manager 5 (All versions \u003c 5.3.4.4), Automation License Manager 6 (All versions \u003c 6.0.1). A directory traversal vulnerability could allow a remote attacker to move arbitrary files, which can result in code execution, compromising confidentiality, integrity and availability of the system. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges or special conditions of the system, but user interaction is required."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-21T09:57:01",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "105114",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105114"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-920962.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2018-11455",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Automation License Manager 5, Automation License Manager 6",
"version": {
"version_data": [
{
"version_value": "Automation License Manager 5 : All versions \u003c 5.3.4.4"
},
{
"version_value": "Automation License Manager 6 : All versions \u003c 6.0.1"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Automation License Manager 5 (All versions \u003c 5.3.4.4), Automation License Manager 6 (All versions \u003c 6.0.1). A directory traversal vulnerability could allow a remote attacker to move arbitrary files, which can result in code execution, compromising confidentiality, integrity and availability of the system. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges or special conditions of the system, but user interaction is required."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "105114",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105114"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-920962.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-920962.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2018-11455",
"datePublished": "2018-08-07T15:00:00",
"dateReserved": "2018-05-25T00:00:00",
"dateUpdated": "2024-08-05T08:10:14.446Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-11456 (GCVE-0-2018-11456)
Vulnerability from cvelistv5
Published
2018-08-07 15:00
Modified
2024-08-05 08:10
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-284 - Improper Access Control
Summary
A vulnerability has been identified in Automation License Manager 5 (All versions < 5.3.4.4). An attacker with network access to the device could send specially crafted network packets to determine whether or not a network port on another remote system is accessible or not. This allows the attacker to do basic network scanning using the victims machine. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges, no user interaction is required. The impact is limited to determining whether or not a port on a target system is accessible by the affected device.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens AG | Automation License Manager 5 |
Version: Automation License Manager 5 : All versions < 5.3.4.4 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T08:10:14.363Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "105114",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105114"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-920962.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Automation License Manager 5",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "Automation License Manager 5 : All versions \u003c 5.3.4.4"
}
]
}
],
"datePublic": "2018-08-07T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Automation License Manager 5 (All versions \u003c 5.3.4.4). An attacker with network access to the device could send specially crafted network packets to determine whether or not a network port on another remote system is accessible or not. This allows the attacker to do basic network scanning using the victims machine. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges, no user interaction is required. The impact is limited to determining whether or not a port on a target system is accessible by the affected device."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-21T09:57:01",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "105114",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105114"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-920962.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2018-11456",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Automation License Manager 5",
"version": {
"version_data": [
{
"version_value": "Automation License Manager 5 : All versions \u003c 5.3.4.4"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Automation License Manager 5 (All versions \u003c 5.3.4.4). An attacker with network access to the device could send specially crafted network packets to determine whether or not a network port on another remote system is accessible or not. This allows the attacker to do basic network scanning using the victims machine. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges, no user interaction is required. The impact is limited to determining whether or not a port on a target system is accessible by the affected device."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284: Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "105114",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105114"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-920962.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-920962.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2018-11456",
"datePublished": "2018-08-07T15:00:00",
"dateReserved": "2018-05-25T00:00:00",
"dateUpdated": "2024-08-05T08:10:14.363Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-11454 (GCVE-0-2018-11454)
Vulnerability from cvelistv5
Published
2018-08-07 15:00
Modified
2024-09-16 18:03
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-276 - Incorrect Default Permissions
Summary
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to manipulate resources which may be transferred to devices and executed there by a different user. No special privileges are required, but the victim needs to transfer the manipulated files to a device. Execution is caused on the target device rather than on the PG device.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens AG | SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 |
Version: SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 : All versions Version: SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 : All versions < V13 SP2 Update 2 Version: SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 : All versions < V14 SP1 Update 6 Version: SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 : All versions < V15 Update 2 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T08:10:14.570Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "105115",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105115"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979106.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 : All versions"
},
{
"status": "affected",
"version": "SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 : All versions \u003c V13 SP2 Update 2"
},
{
"status": "affected",
"version": "SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 : All versions \u003c V14 SP1 Update 6"
},
{
"status": "affected",
"version": "SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 : All versions \u003c V15 Update 2"
}
]
}
],
"datePublic": "2018-08-07T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions \u003c V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions \u003c V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to manipulate resources which may be transferred to devices and executed there by a different user. No special privileges are required, but the victim needs to transfer the manipulated files to a device. Execution is caused on the target device rather than on the PG device."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276: Incorrect Default Permissions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-10-10T16:57:01",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "105115",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105115"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979106.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"DATE_PUBLIC": "2018-08-07T00:00:00",
"ID": "CVE-2018-11454",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15",
"version": {
"version_data": [
{
"version_value": "SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 : All versions"
},
{
"version_value": "SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 : All versions \u003c V13 SP2 Update 2"
},
{
"version_value": "SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 : All versions \u003c V14 SP1 Update 6"
},
{
"version_value": "SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 : All versions \u003c V15 Update 2"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions \u003c V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions \u003c V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to manipulate resources which may be transferred to devices and executed there by a different user. No special privileges are required, but the victim needs to transfer the manipulated files to a device. Execution is caused on the target device rather than on the PG device."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-276: Incorrect Default Permissions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "105115",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105115"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-979106.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979106.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2018-11454",
"datePublished": "2018-08-07T15:00:00Z",
"dateReserved": "2018-05-25T00:00:00",
"dateUpdated": "2024-09-16T18:03:30.602Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-3737 (GCVE-0-2017-3737)
Vulnerability from cvelistv5
Published
2017-12-07 16:00
Modified
2024-09-17 03:53
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Unauthenticated read/unencrypted write
Summary
OpenSSL 1.0.2 (starting from version 1.0.2b) introduced an "error state" mechanism. The intent was that if a fatal error occurred during a handshake then OpenSSL would move into the error state and would immediately fail if you attempted to continue the handshake. This works as designed for the explicit handshake functions (SSL_do_handshake(), SSL_accept() and SSL_connect()), however due to a bug it does not work correctly if SSL_read() or SSL_write() is called directly. In that scenario, if the handshake fails then a fatal error will be returned in the initial function call. If SSL_read()/SSL_write() is subsequently called by the application for the same SSL object then it will succeed and the data is passed without being decrypted/encrypted directly from the SSL/TLS record layer. In order to exploit this issue an application bug would have to be present that resulted in a call to SSL_read()/SSL_write() being issued after having already received a fatal error. OpenSSL version 1.0.2b-1.0.2m are affected. Fixed in OpenSSL 1.0.2n. OpenSSL 1.1.0 is not affected.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| OpenSSL Software Foundation | OpenSSL |
Version: 1.0.2b-1.0.2m |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:39:40.599Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "RHSA-2018:2185",
"tags": [
"vendor-advisory",
"x_refsource_REDHAT",
"x_transferred"
],
"url": "https://access.redhat.com/errata/RHSA-2018:2185"
},
{
"name": "RHSA-2018:2186",
"tags": [
"vendor-advisory",
"x_refsource_REDHAT",
"x_transferred"
],
"url": "https://access.redhat.com/errata/RHSA-2018:2186"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://github.com/openssl/openssl/commit/898fb884b706aaeb283de4812340bb0bde8476dc"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpujul2018-4258247.html"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpujan2018-3236628.html"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20180419-0002/"
},
{
"name": "FreeBSD-SA-17:12",
"tags": [
"vendor-advisory",
"x_refsource_FREEBSD",
"x_transferred"
],
"url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-17:12.openssl.asc"
},
{
"name": "GLSA-201712-03",
"tags": [
"vendor-advisory",
"x_refsource_GENTOO",
"x_transferred"
],
"url": "https://security.gentoo.org/glsa/201712-03"
},
{
"name": "1039978",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1039978"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.openssl.org/news/secadv/20171207.txt"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.digitalmunition.me/2017/12/cve-2017-3737-openssl-security-bypass-vulnerability/"
},
{
"name": "RHSA-2018:0998",
"tags": [
"vendor-advisory",
"x_refsource_REDHAT",
"x_transferred"
],
"url": "https://access.redhat.com/errata/RHSA-2018:0998"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2018-3678067.html"
},
{
"name": "DSA-4065",
"tags": [
"vendor-advisory",
"x_refsource_DEBIAN",
"x_transferred"
],
"url": "https://www.debian.org/security/2017/dsa-4065"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-179516.pdf"
},
{
"name": "102103",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/102103"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.tenable.com/security/tns-2017-16"
},
{
"name": "RHSA-2018:2187",
"tags": [
"vendor-advisory",
"x_refsource_REDHAT",
"x_transferred"
],
"url": "https://access.redhat.com/errata/RHSA-2018:2187"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20180117-0002/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20171208-0001/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.oracle.com/technetwork/security-advisory/cpujul2019-5072835.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "OpenSSL",
"vendor": "OpenSSL Software Foundation",
"versions": [
{
"status": "affected",
"version": "1.0.2b-1.0.2m"
}
]
}
],
"datePublic": "2017-12-07T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "OpenSSL 1.0.2 (starting from version 1.0.2b) introduced an \"error state\" mechanism. The intent was that if a fatal error occurred during a handshake then OpenSSL would move into the error state and would immediately fail if you attempted to continue the handshake. This works as designed for the explicit handshake functions (SSL_do_handshake(), SSL_accept() and SSL_connect()), however due to a bug it does not work correctly if SSL_read() or SSL_write() is called directly. In that scenario, if the handshake fails then a fatal error will be returned in the initial function call. If SSL_read()/SSL_write() is subsequently called by the application for the same SSL object then it will succeed and the data is passed without being decrypted/encrypted directly from the SSL/TLS record layer. In order to exploit this issue an application bug would have to be present that resulted in a call to SSL_read()/SSL_write() being issued after having already received a fatal error. OpenSSL version 1.0.2b-1.0.2m are affected. Fixed in OpenSSL 1.0.2n. OpenSSL 1.1.0 is not affected."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Unauthenticated read/unencrypted write",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-07-23T22:31:33",
"orgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
"shortName": "openssl"
},
"references": [
{
"name": "RHSA-2018:2185",
"tags": [
"vendor-advisory",
"x_refsource_REDHAT"
],
"url": "https://access.redhat.com/errata/RHSA-2018:2185"
},
{
"name": "RHSA-2018:2186",
"tags": [
"vendor-advisory",
"x_refsource_REDHAT"
],
"url": "https://access.redhat.com/errata/RHSA-2018:2186"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/openssl/openssl/commit/898fb884b706aaeb283de4812340bb0bde8476dc"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpujul2018-4258247.html"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpujan2018-3236628.html"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20180419-0002/"
},
{
"name": "FreeBSD-SA-17:12",
"tags": [
"vendor-advisory",
"x_refsource_FREEBSD"
],
"url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-17:12.openssl.asc"
},
{
"name": "GLSA-201712-03",
"tags": [
"vendor-advisory",
"x_refsource_GENTOO"
],
"url": "https://security.gentoo.org/glsa/201712-03"
},
{
"name": "1039978",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1039978"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.openssl.org/news/secadv/20171207.txt"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.digitalmunition.me/2017/12/cve-2017-3737-openssl-security-bypass-vulnerability/"
},
{
"name": "RHSA-2018:0998",
"tags": [
"vendor-advisory",
"x_refsource_REDHAT"
],
"url": "https://access.redhat.com/errata/RHSA-2018:0998"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2018-3678067.html"
},
{
"name": "DSA-4065",
"tags": [
"vendor-advisory",
"x_refsource_DEBIAN"
],
"url": "https://www.debian.org/security/2017/dsa-4065"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-179516.pdf"
},
{
"name": "102103",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/102103"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.tenable.com/security/tns-2017-16"
},
{
"name": "RHSA-2018:2187",
"tags": [
"vendor-advisory",
"x_refsource_REDHAT"
],
"url": "https://access.redhat.com/errata/RHSA-2018:2187"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20180117-0002/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20171208-0001/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.oracle.com/technetwork/security-advisory/cpujul2019-5072835.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "openssl-security@openssl.org",
"DATE_PUBLIC": "2017-12-07T00:00:00",
"ID": "CVE-2017-3737",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "OpenSSL",
"version": {
"version_data": [
{
"version_value": "1.0.2b-1.0.2m"
}
]
}
}
]
},
"vendor_name": "OpenSSL Software Foundation"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "OpenSSL 1.0.2 (starting from version 1.0.2b) introduced an \"error state\" mechanism. The intent was that if a fatal error occurred during a handshake then OpenSSL would move into the error state and would immediately fail if you attempted to continue the handshake. This works as designed for the explicit handshake functions (SSL_do_handshake(), SSL_accept() and SSL_connect()), however due to a bug it does not work correctly if SSL_read() or SSL_write() is called directly. In that scenario, if the handshake fails then a fatal error will be returned in the initial function call. If SSL_read()/SSL_write() is subsequently called by the application for the same SSL object then it will succeed and the data is passed without being decrypted/encrypted directly from the SSL/TLS record layer. In order to exploit this issue an application bug would have to be present that resulted in a call to SSL_read()/SSL_write() being issued after having already received a fatal error. OpenSSL version 1.0.2b-1.0.2m are affected. Fixed in OpenSSL 1.0.2n. OpenSSL 1.1.0 is not affected."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Unauthenticated read/unencrypted write"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "RHSA-2018:2185",
"refsource": "REDHAT",
"url": "https://access.redhat.com/errata/RHSA-2018:2185"
},
{
"name": "RHSA-2018:2186",
"refsource": "REDHAT",
"url": "https://access.redhat.com/errata/RHSA-2018:2186"
},
{
"name": "https://github.com/openssl/openssl/commit/898fb884b706aaeb283de4812340bb0bde8476dc",
"refsource": "CONFIRM",
"url": "https://github.com/openssl/openssl/commit/898fb884b706aaeb283de4812340bb0bde8476dc"
},
{
"name": "http://www.oracle.com/technetwork/security-advisory/cpujul2018-4258247.html",
"refsource": "CONFIRM",
"url": "http://www.oracle.com/technetwork/security-advisory/cpujul2018-4258247.html"
},
{
"name": "http://www.oracle.com/technetwork/security-advisory/cpujan2018-3236628.html",
"refsource": "CONFIRM",
"url": "http://www.oracle.com/technetwork/security-advisory/cpujan2018-3236628.html"
},
{
"name": "https://security.netapp.com/advisory/ntap-20180419-0002/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20180419-0002/"
},
{
"name": "FreeBSD-SA-17:12",
"refsource": "FREEBSD",
"url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-17:12.openssl.asc"
},
{
"name": "GLSA-201712-03",
"refsource": "GENTOO",
"url": "https://security.gentoo.org/glsa/201712-03"
},
{
"name": "1039978",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1039978"
},
{
"name": "https://www.openssl.org/news/secadv/20171207.txt",
"refsource": "CONFIRM",
"url": "https://www.openssl.org/news/secadv/20171207.txt"
},
{
"name": "https://www.digitalmunition.me/2017/12/cve-2017-3737-openssl-security-bypass-vulnerability/",
"refsource": "MISC",
"url": "https://www.digitalmunition.me/2017/12/cve-2017-3737-openssl-security-bypass-vulnerability/"
},
{
"name": "RHSA-2018:0998",
"refsource": "REDHAT",
"url": "https://access.redhat.com/errata/RHSA-2018:0998"
},
{
"name": "http://www.oracle.com/technetwork/security-advisory/cpuapr2018-3678067.html",
"refsource": "CONFIRM",
"url": "http://www.oracle.com/technetwork/security-advisory/cpuapr2018-3678067.html"
},
{
"name": "DSA-4065",
"refsource": "DEBIAN",
"url": "https://www.debian.org/security/2017/dsa-4065"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-179516.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-179516.pdf"
},
{
"name": "102103",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/102103"
},
{
"name": "https://www.tenable.com/security/tns-2017-16",
"refsource": "CONFIRM",
"url": "https://www.tenable.com/security/tns-2017-16"
},
{
"name": "RHSA-2018:2187",
"refsource": "REDHAT",
"url": "https://access.redhat.com/errata/RHSA-2018:2187"
},
{
"name": "https://security.netapp.com/advisory/ntap-20180117-0002/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20180117-0002/"
},
{
"name": "https://security.netapp.com/advisory/ntap-20171208-0001/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20171208-0001/"
},
{
"name": "https://www.oracle.com/technetwork/security-advisory/cpujul2019-5072835.html",
"refsource": "MISC",
"url": "https://www.oracle.com/technetwork/security-advisory/cpujul2019-5072835.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
"assignerShortName": "openssl",
"cveId": "CVE-2017-3737",
"datePublished": "2017-12-07T16:00:00Z",
"dateReserved": "2016-12-16T00:00:00",
"dateUpdated": "2024-09-17T03:53:31.262Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-11453 (GCVE-0-2018-11453)
Vulnerability from cvelistv5
Published
2018-08-07 15:00
Modified
2024-09-16 17:42
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-276 - Incorrect Default Permissions
Summary
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to insert specially crafted files which may prevent TIA Portal startup (Denial-of-Service) or lead to local code execution. No special privileges are required, but the victim needs to attempt to start TIA Portal after the manipulation.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens AG | SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 |
Version: SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 : All versions Version: SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 : All versions < V13 SP2 Update 2 Version: SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 : All versions < V14 SP1 Update 6 Version: SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 : All versions < V15 Update 2 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T08:10:14.192Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "105115",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105115"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979106.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 : All versions"
},
{
"status": "affected",
"version": "SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 : All versions \u003c V13 SP2 Update 2"
},
{
"status": "affected",
"version": "SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 : All versions \u003c V14 SP1 Update 6"
},
{
"status": "affected",
"version": "SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 : All versions \u003c V15 Update 2"
}
]
}
],
"datePublic": "2018-08-07T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions \u003c V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions \u003c V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to insert specially crafted files which may prevent TIA Portal startup (Denial-of-Service) or lead to local code execution. No special privileges are required, but the victim needs to attempt to start TIA Portal after the manipulation."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276: Incorrect Default Permissions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-10-10T16:57:01",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "105115",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105115"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979106.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"DATE_PUBLIC": "2018-08-07T00:00:00",
"ID": "CVE-2018-11453",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15",
"version": {
"version_data": [
{
"version_value": "SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 : All versions"
},
{
"version_value": "SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 : All versions \u003c V13 SP2 Update 2"
},
{
"version_value": "SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 : All versions \u003c V14 SP1 Update 6"
},
{
"version_value": "SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 : All versions \u003c V15 Update 2"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions \u003c V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions \u003c V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to insert specially crafted files which may prevent TIA Portal startup (Denial-of-Service) or lead to local code execution. No special privileges are required, but the victim needs to attempt to start TIA Portal after the manipulation."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-276: Incorrect Default Permissions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "105115",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105115"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-979106.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979106.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2018-11453",
"datePublished": "2018-08-07T15:00:00Z",
"dateReserved": "2018-05-25T00:00:00",
"dateUpdated": "2024-09-16T17:42:55.535Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…