ICSA-23-131-03
Vulnerability from csaf_cisa
Published
2023-05-09 00:00
Modified
2023-05-09 00:00
Summary
Siemens Siveillance
Notes
Summary
Both the Event Server and the Management Server components of Siveillance Video deserialize data without sufficient validations. This could allow an authenticated remote attacker to execute code on the affected system.
Siemens has released updates for the affected products and recommends to update to the latest versions. The provided cumulative hotfix releases include the fixes for both Event Server (ES) and Management Server (MS). Ensure to apply the fixes on all relevant servers in your deployment.
General Recommendations
As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Both the Event Server and the Management Server components of Siveillance Video deserialize data without sufficient validations. This could allow an authenticated remote attacker to execute code on the affected system.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions. The provided cumulative hotfix releases include the fixes for both Event Server (ES) and Management Server (MS). Ensure to apply the fixes on all relevant servers in your deployment.", "title": "Summary" }, { "category": "general", "text": "As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-789345: Code Execution Vulnerabilities in Siveillance Video Event and Management Servers - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-789345.json" }, { "category": "self", "summary": "SSA-789345: Code Execution Vulnerabilities in Siveillance Video Event and Management Servers - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-789345.html" }, { "category": "self", "summary": "SSA-789345: Code Execution Vulnerabilities in Siveillance Video Event and Management Servers - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789345.pdf" }, { "category": "self", "summary": "SSA-789345: Code Execution Vulnerabilities in Siveillance Video Event and Management Servers - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-789345.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-23-131-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-131-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-131-03 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-131-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Siveillance", "tracking": { "current_release_date": "2023-05-09T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-131-03", "initial_release_date": "2023-05-09T00:00:00.000000Z", "revision_history": [ { "date": "2023-05-09T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cvers:/_V20.2_HotfixRev14", "product": { "name": "Siveillance Video 2020 R2", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Siveillance Video 2020 R2" }, { "branches": [ { "category": "product_version_range", "name": "\u003cvers:/_V20.3_HotfixRev12", "product": { "name": "Siveillance Video 2020 R3", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Siveillance Video 2020 R3" }, { "branches": [ { "category": "product_version_range", "name": "\u003cvers:/_V21.1_HotfixRev12", "product": { "name": "Siveillance Video 2021 R1", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Siveillance Video 2021 R1" }, { "branches": [ { "category": "product_version_range", "name": "\u003cvers:/_V21.2_HotfixRev8", "product": { "name": "Siveillance Video 2021 R2", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Siveillance Video 2021 R2" }, { "branches": [ { "category": "product_version_range", "name": "\u003cvers:/_V22.1_HotfixRev7", "product": { "name": "Siveillance Video 2022 R1", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "Siveillance Video 2022 R1" }, { "branches": [ { "category": "product_version_range", "name": "\u003cvers:/_V22.2_HotfixRev5", "product": { "name": "Siveillance Video 2022 R2", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "Siveillance Video 2022 R2" }, { "branches": [ { "category": "product_version_range", "name": "\u003cvers:/_V22.3_HotfixRev2", "product": { "name": "Siveillance Video 2022 R3", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "Siveillance Video 2022 R3" }, { "branches": [ { "category": "product_version_range", "name": "\u003cvers:/_V23.1_HotfixRev1", "product": { "name": "Siveillance Video 2023 R1", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "Siveillance Video 2023 R1" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-30898", "cwe": { "id": "CWE-502", "name": "Deserialization of Untrusted Data" }, "notes": [ { "category": "summary", "text": "The Event Server component of affected applications deserializes data without sufficient validations. This could allow an authenticated remote attacker to execute code on the affected system.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V20.2 HotfixRev14 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109781128/" }, { "category": "vendor_fix", "details": "Update to V20.3 HotfixRev12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109791980/" }, { "category": "vendor_fix", "details": "Update to V21.1 HotfixRev12 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109801904/" }, { "category": "vendor_fix", "details": "Update to V21.2 HotfixRev8 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805466/" }, { "category": "vendor_fix", "details": "Update to V22.1 HotfixRev7 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109810201/" }, { "category": "vendor_fix", "details": "Update to V22.2 HotfixRev5 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109812608/" }, { "category": "vendor_fix", "details": "Update to V22.3 HotfixRev2 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815353/" }, { "category": "vendor_fix", "details": "Update to V23.1 HotfixRev1 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109820659/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.9, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2023-30898" }, { "cve": "CVE-2023-30899", "cwe": { "id": "CWE-502", "name": "Deserialization of Untrusted Data" }, "notes": [ { "category": "summary", "text": "The Management Server component of affected applications deserializes data without sufficient validations. This could allow an authenticated remote attacker to execute code on the affected system.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V20.2 HotfixRev14 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109781128/" }, { "category": "vendor_fix", "details": "Update to V20.3 HotfixRev12 or later version", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109791980/" }, { "category": "vendor_fix", "details": "Update to V21.1 HotfixRev12 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109801904/" }, { "category": "vendor_fix", "details": "Update to V21.2 HotfixRev8 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805466/" }, { "category": "vendor_fix", "details": "Update to V22.1 HotfixRev7 or later version", "product_ids": [ "CSAFPID-0005" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109810201/" }, { "category": "vendor_fix", "details": "Update to V22.2 HotfixRev5 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109812608/" }, { "category": "vendor_fix", "details": "Update to V22.3 HotfixRev2 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109815353/" }, { "category": "vendor_fix", "details": "Update to V23.1 HotfixRev1 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109820659/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.9, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008" ] } ], "title": "CVE-2023-30899" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…