ICSA-22-055-03
Vulnerability from csaf_cisa
Published
2022-02-24 00:00
Modified
2022-02-24 00:00
Summary
Schneider Electric Easergy P5 and P3

Notes

CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities may disclose device credentials, cause a denial-of-service condition, device reboot, or allow an attacker to gain full control of the relay. This could result in loss of protection to your electrical network.
Critical infrastructure sectors
Commercial Facilities, Energy
Countries/areas deployed
Worldwide
Company headquarters location
France
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
Exploitability
No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.



{
  "document": {
    "acknowledgments": [
      {
        "names": [
          "Timoth\u00e9e Chauvin",
          "Paul Noalhyt",
          "Yuanzhe Wu"
        ],
        "organization": "Red Balloon Security",
        "summary": "reporting these vulnerabilities to CISA"
      }
    ],
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited",
      "tlp": {
        "label": "WHITE",
        "url": "https://us-cert.cisa.gov/tlp/"
      }
    },
    "lang": "en-US",
    "notes": [
      {
        "category": "general",
        "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
        "title": "CISA Disclaimer"
      },
      {
        "category": "legal_disclaimer",
        "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
        "title": "Legal Notice"
      },
      {
        "category": "summary",
        "text": "Successful exploitation of these vulnerabilities may disclose device credentials, cause a denial-of-service condition, device reboot, or allow an attacker to gain full control of the relay. This could result in loss of protection to your electrical network.",
        "title": "Risk evaluation"
      },
      {
        "category": "other",
        "text": "Commercial Facilities, Energy",
        "title": "Critical infrastructure sectors"
      },
      {
        "category": "other",
        "text": "Worldwide",
        "title": "Countries/areas deployed"
      },
      {
        "category": "other",
        "text": "France",
        "title": "Company headquarters location"
      },
      {
        "category": "general",
        "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
        "title": "Recommended Practices"
      },
      {
        "category": "other",
        "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.",
        "title": "Exploitability"
      }
    ],
    "publisher": {
      "category": "coordinator",
      "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
      "name": "CISA",
      "namespace": "https://www.cisa.gov/"
    },
    "references": [
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-22-055-03 JSON",
        "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-055-03.json"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-22-055-03 Web Version",
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-055-03"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
      }
    ],
    "title": "Schneider Electric Easergy P5 and P3",
    "tracking": {
      "current_release_date": "2022-02-24T00:00:00.000000Z",
      "generator": {
        "engine": {
          "name": "CISA CSAF Generator",
          "version": "1.0.0"
        }
      },
      "id": "ICSA-22-055-03",
      "initial_release_date": "2022-02-24T00:00:00.000000Z",
      "revision_history": [
        {
          "date": "2022-02-24T00:00:00.000000Z",
          "legacy_version": "Initial",
          "number": "1",
          "summary": "ICSA-22-055-03 Schneider Electric Easergy P5 and P3"
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c 30.205",
                "product": {
                  "name": "Easergy P3: All versions prior to v30.205",
                  "product_id": "CSAFPID-0001"
                }
              }
            ],
            "category": "product_name",
            "name": "Easergy P3"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c 01.401.102",
                "product": {
                  "name": "Easergy P5 All firmware: versions prior to v01.401.102",
                  "product_id": "CSAFPID-0002"
                }
              }
            ],
            "category": "product_name",
            "name": "Easergy P5 All firmware"
          }
        ],
        "category": "vendor",
        "name": "Schneider Electric Software, LLC"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2022-22722",
      "cwe": {
        "id": "CWE-798",
        "name": "Use of Hard-coded Credentials"
      },
      "notes": [
        {
          "category": "summary",
          "text": "If an attacker were to obtain the SSH cryptographic key for the device and take active control of the local operational network connected to this product, they could observe and manipulate traffic associated with product configuration. This could result in information disclosure. CVE-2022-22722 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).",
          "title": "Vulnerability Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-22722"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "Schneider Electric recommends users using Easergy P5 upgrade to v01.402.101 and users using Easergy P3 upgrade to version 30.205. These firmware upgrades include a fix for the identified vulnerabilities and are available upon request from Schneider Electric\u0027s Customer Care Center.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ],
          "url": "https://www.se.com/us/en/work/support/contacts.jsp"
        },
        {
          "category": "mitigation",
          "details": "Disable the GOOSE service of the product to reduce the risk of exposure. If GOOSE is needed for the application, use it only in a secure local area network.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "For more information see Schneider Electric\u0027s security notifications: SEVD-2022-011-03, SEVD-2022-011-04",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ],
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03"
        },
        {
          "category": "mitigation",
          "details": "Schneider Electric recommends users use appropriate patching methodologies when applying these patches to their systems. Schneider Electric recommends the use of backups and an evaluation of the impact of these patches in a test and development environment or on an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center for assistance removing a patch.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ],
          "url": "https://www.se.com/us/en/work/support/contacts.jsp"
        },
        {
          "category": "mitigation",
          "details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Install physical controls so no unauthorized personnel can access industrial control and safety systems, components, peripheral equipment, and networks.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Never connect programming software to any network other than a network intended to for the devices.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc., before use in the terminals or any node connected to these networks.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Minimize network exposure for all control system devices and systems and ensure they are not accessible from the Internet.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand VPNs are only as secure as the connected devices.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ]
    },
    {
      "cve": "CVE-2022-22723",
      "cwe": {
        "id": "CWE-120",
        "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
      },
      "notes": [
        {
          "category": "summary",
          "text": "A buffer copy without checking size of input vulnerability exists in Easergy P5 devices that could lead to a buffer overflow, causing program crashes and arbitrary code execution when specially crafted packets are sent to the device over the network. Protection functions and tripping functions via GOOSE can be impacted. CVE-2022-22723 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
          "title": "Vulnerability Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-22723"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "Schneider Electric recommends users using Easergy P5 upgrade to v01.402.101 and users using Easergy P3 upgrade to version 30.205. These firmware upgrades include a fix for the identified vulnerabilities and are available upon request from Schneider Electric\u0027s Customer Care Center.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ],
          "url": "https://www.se.com/us/en/work/support/contacts.jsp"
        },
        {
          "category": "mitigation",
          "details": "For CVE-2022-22723 and CVE-2022-22725 only, if users choose not to apply the remediation provided above, they should immediately apply the following mitigation to reduce the risk of exploit:",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Disable the GOOSE service of the product to reduce the risk of exposure. If GOOSE is needed for the application, use it only in a secure local area network.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "For more information see Schneider Electric\u0027s security notifications: SEVD-2022-011-03, SEVD-2022-011-04",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ],
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03"
        },
        {
          "category": "mitigation",
          "details": "Schneider Electric recommends users use appropriate patching methodologies when applying these patches to their systems. Schneider Electric recommends the use of backups and an evaluation of the impact of these patches in a test and development environment or on an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center for assistance removing a patch.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ],
          "url": "https://www.se.com/us/en/work/support/contacts.jsp"
        },
        {
          "category": "mitigation",
          "details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Install physical controls so no unauthorized personnel can access industrial control and safety systems, components, peripheral equipment, and networks.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Never connect programming software to any network other than a network intended to for the devices.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc., before use in the terminals or any node connected to these networks.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Minimize network exposure for all control system devices and systems and ensure they are not accessible from the Internet.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand VPNs are only as secure as the connected devices.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ]
    },
    {
      "cve": "CVE-2022-22725",
      "cwe": {
        "id": "CWE-120",
        "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
      },
      "notes": [
        {
          "category": "summary",
          "text": "A buffer copy without checking size of input vulnerability exists in Easergy P3 devices that could lead to a buffer overflow, causing program crashes and arbitrary code execution when specially crafted packets are sent to the device over the network. Protection functions and tripping functions via GOOSE can be impacted. CVE-2022-22725 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
          "title": "Vulnerability Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-22725"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "Schneider Electric recommends users using Easergy P5 upgrade to v01.402.101 and users using Easergy P3 upgrade to version 30.205. These firmware upgrades include a fix for the identified vulnerabilities and are available upon request from Schneider Electric\u0027s Customer Care Center.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ],
          "url": "https://www.se.com/us/en/work/support/contacts.jsp"
        },
        {
          "category": "mitigation",
          "details": "For CVE-2022-22723 and CVE-2022-22725 only, if users choose not to apply the remediation provided above, they should immediately apply the following mitigation to reduce the risk of exploit:",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Disable the GOOSE service of the product to reduce the risk of exposure. If GOOSE is needed for the application, use it only in a secure local area network.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "For more information see Schneider Electric\u0027s security notifications: SEVD-2022-011-03, SEVD-2022-011-04",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ],
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03"
        },
        {
          "category": "mitigation",
          "details": "Schneider Electric recommends users use appropriate patching methodologies when applying these patches to their systems. Schneider Electric recommends the use of backups and an evaluation of the impact of these patches in a test and development environment or on an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center for assistance removing a patch.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ],
          "url": "https://www.se.com/us/en/work/support/contacts.jsp"
        },
        {
          "category": "mitigation",
          "details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Install physical controls so no unauthorized personnel can access industrial control and safety systems, components, peripheral equipment, and networks.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Never connect programming software to any network other than a network intended to for the devices.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc., before use in the terminals or any node connected to these networks.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Minimize network exposure for all control system devices and systems and ensure they are not accessible from the Internet.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand VPNs are only as secure as the connected devices.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ]
    },
    {
      "cve": "CVE-2022-34758",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An Improper Input Validation vulnerability exists in Easergy P5 devices that cause the device watchdog function to be disabled if the attacker had access to privileged user credentials. CVE-2022-34758 has been assigned to this vulnerability. A CVSS v3 base score of 5.1 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:L).",
          "title": "Vulnerability Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-34758"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:L"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "Schneider Electric recommends users using Easergy P5 upgrade to v01.402.101 and users using Easergy P3 upgrade to version 30.205. These firmware upgrades include a fix for the identified vulnerabilities and are available upon request from Schneider Electric\u0027s Customer Care Center.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ],
          "url": "https://www.se.com/us/en/work/support/contacts.jsp"
        },
        {
          "category": "mitigation",
          "details": "Disable the GOOSE service of the product to reduce the risk of exposure. If GOOSE is needed for the application, use it only in a secure local area network.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "For more information see Schneider Electric\u0027s security notifications: SEVD-2022-011-03, SEVD-2022-011-04",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ],
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03"
        },
        {
          "category": "mitigation",
          "details": "Schneider Electric recommends users use appropriate patching methodologies when applying these patches to their systems. Schneider Electric recommends the use of backups and an evaluation of the impact of these patches in a test and development environment or on an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center for assistance removing a patch.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ],
          "url": "https://www.se.com/us/en/work/support/contacts.jsp"
        },
        {
          "category": "mitigation",
          "details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Install physical controls so no unauthorized personnel can access industrial control and safety systems, components, peripheral equipment, and networks.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Never connect programming software to any network other than a network intended to for the devices.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc., before use in the terminals or any node connected to these networks.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "Minimize network exposure for all control system devices and systems and ensure they are not accessible from the Internet.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand VPNs are only as secure as the connected devices.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:L",
            "version": "3.0"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ]
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…