CVE-2025-9574 (GCVE-0-2025-9574)
Vulnerability from cvelistv5
Published
2025-10-20 16:56
Modified
2025-10-20 17:32
Severity ?
9.9 (Critical) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:H/S:N/AU:Y/R:U/V:D/RE:M/U:Red
9.1 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
9.1 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
VLAI Severity ?
EPSS score ?
CWE
- CWE-306 - Missing Authentication for Critical Function
Summary
Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.This issue affects .
All firmware versions with the Serial Number from 2000 to 5166
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
ABB | ALS-mini-s4 IP |
Version: 0 < |
|||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-9574", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-10-20T17:31:19.456273Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-10-20T17:32:51.170Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "ALS-mini-s4 IP", "vendor": "ABB", "versions": [ { "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ALS-mini-s8 IP", "vendor": "ABB", "versions": [ { "status": "affected", "version": "0" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "ABB acknowledges Souvik Kandar of MicroSec (microsec.io), for reporting vulnerabilities in responsible disclosure." } ], "datePublic": "2025-10-20T00:36:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.\u003cp\u003eThis issue affects .\u0026nbsp;\n\nAll firmware versions with the Serial Number from 2000 to 5166\n\n\u003c/p\u003e" } ], "value": "Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.This issue affects .\u00a0\n\nAll firmware versions with the Serial Number from 2000 to 5166" } ], "metrics": [ { "cvssV4_0": { "Automatable": "YES", "Recovery": "USER", "Safety": "NEGLIGIBLE", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 9.9, "baseSeverity": "CRITICAL", "privilegesRequired": "NONE", "providerUrgency": "RED", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "DIFFUSE", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:H/S:N/AU:Y/R:U/V:D/RE:M/U:Red", "version": "4.0", "vulnAvailabilityImpact": "NONE", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "MODERATE" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] }, { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-10-20T16:56:32.337Z", "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "shortName": "ABB" }, "references": [ { "url": "https://search.abb.com/library/Download.aspx?DocumentID=4TZ00000006007\u0026LanguageCode=en\u0026DocumentPartId=PDF\u0026Action=Launch" } ], "source": { "discovery": "UNKNOWN" }, "title": "Missing Authentication Vulnerability", "workarounds": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Workarounds are specific measures that a user can take to help block an attack. ABB has tested the following workarounds. Although these workarounds will not correct the underlying vulnerability, they can\nhelp block known attack vectors. When a workaround reduces functionality, this is identified below as\n\u201cImpact of workaround\u201d.\u003cbr\u003e\u003cbr\u003e\n\u2013 Physically disconnect the ethernet port if embedded web server is not being used.\u003cbr\u003e\u003cbr\u003e\nImpact of workaround\n\u003cbr\u003e\u003cbr\u003eThe embedded web server and all its functionalities, incl. load monitoring, alarms, remote configuration,\netc. will not be accessible. However, the product will continue functioning as normal based on configured control parameters.\n\n\u003cbr\u003e" } ], "value": "Workarounds are specific measures that a user can take to help block an attack. ABB has tested the following workarounds. Although these workarounds will not correct the underlying vulnerability, they can\nhelp block known attack vectors. When a workaround reduces functionality, this is identified below as\n\u201cImpact of workaround\u201d.\n\n\n\u2013 Physically disconnect the ethernet port if embedded web server is not being used.\n\n\nImpact of workaround\n\n\nThe embedded web server and all its functionalities, incl. load monitoring, alarms, remote configuration,\netc. will not be accessible. However, the product will continue functioning as normal based on configured control parameters." } ], "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "assignerShortName": "ABB", "cveId": "CVE-2025-9574", "datePublished": "2025-10-20T16:56:32.337Z", "dateReserved": "2025-08-28T10:04:01.947Z", "dateUpdated": "2025-10-20T17:32:51.170Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2025-9574\",\"sourceIdentifier\":\"cybersecurity@ch.abb.com\",\"published\":\"2025-10-20T17:15:39.367\",\"lastModified\":\"2025-10-20T17:15:39.367\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.This issue affects .\u00a0\\n\\nAll firmware versions with the Serial Number from 2000 to 5166\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cybersecurity@ch.abb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:N/AU:Y/R:U/V:D/RE:M/U:Red\",\"baseScore\":9.9,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"NONE\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"HIGH\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NEGLIGIBLE\",\"Automatable\":\"YES\",\"Recovery\":\"USER\",\"valueDensity\":\"DIFFUSE\",\"vulnerabilityResponseEffort\":\"MODERATE\",\"providerUrgency\":\"RED\"}}],\"cvssMetricV31\":[{\"source\":\"cybersecurity@ch.abb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":5.2}]},\"weaknesses\":[{\"source\":\"cybersecurity@ch.abb.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"references\":[{\"url\":\"https://search.abb.com/library/Download.aspx?DocumentID=4TZ00000006007\u0026LanguageCode=en\u0026DocumentPartId=PDF\u0026Action=Launch\",\"source\":\"cybersecurity@ch.abb.com\"}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-9574\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-10-20T17:31:19.456273Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-10-20T17:32:43.042Z\"}}], \"cna\": {\"title\": \"Missing Authentication Vulnerability\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"ABB acknowledges Souvik Kandar of MicroSec (microsec.io), for reporting vulnerabilities in responsible disclosure.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NEGLIGIBLE\", \"version\": \"4.0\", \"Recovery\": \"USER\", \"baseScore\": 9.9, \"Automatable\": \"YES\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"valueDensity\": \"DIFFUSE\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:H/S:N/AU:Y/R:U/V:D/RE:M/U:Red\", \"providerUrgency\": \"RED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"HIGH\", \"vulnAvailabilityImpact\": \"NONE\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"MODERATE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.1, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"ABB\", \"product\": \"ALS-mini-s4 IP\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"ABB\", \"product\": \"ALS-mini-s8 IP\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2025-10-20T00:36:00.000Z\", \"references\": [{\"url\": \"https://search.abb.com/library/Download.aspx?DocumentID=4TZ00000006007\u0026LanguageCode=en\u0026DocumentPartId=PDF\u0026Action=Launch\"}], \"workarounds\": [{\"lang\": \"en\", \"value\": \"Workarounds are specific measures that a user can take to help block an attack. ABB has tested the following workarounds. Although these workarounds will not correct the underlying vulnerability, they can\\nhelp block known attack vectors. When a workaround reduces functionality, this is identified below as\\n\\u201cImpact of workaround\\u201d.\\n\\n\\n\\u2013 Physically disconnect the ethernet port if embedded web server is not being used.\\n\\n\\nImpact of workaround\\n\\n\\nThe embedded web server and all its functionalities, incl. load monitoring, alarms, remote configuration,\\netc. will not be accessible. However, the product will continue functioning as normal based on configured control parameters.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Workarounds are specific measures that a user can take to help block an attack. ABB has tested the following workarounds. Although these workarounds will not correct the underlying vulnerability, they can\\nhelp block known attack vectors. When a workaround reduces functionality, this is identified below as\\n\\u201cImpact of workaround\\u201d.\u003cbr\u003e\u003cbr\u003e\\n\\u2013 Physically disconnect the ethernet port if embedded web server is not being used.\u003cbr\u003e\u003cbr\u003e\\nImpact of workaround\\n\u003cbr\u003e\u003cbr\u003eThe embedded web server and all its functionalities, incl. load monitoring, alarms, remote configuration,\\netc. will not be accessible. However, the product will continue functioning as normal based on configured control parameters.\\n\\n\u003cbr\u003e\", \"base64\": false}]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.This issue affects .\\u00a0\\n\\nAll firmware versions with the Serial Number from 2000 to 5166\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.\u003cp\u003eThis issue affects .\u0026nbsp;\\n\\nAll firmware versions with the Serial Number from 2000 to 5166\\n\\n\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-306\", \"description\": \"CWE-306 Missing Authentication for Critical Function\"}]}], \"providerMetadata\": {\"orgId\": \"2b718523-d88f-4f37-9bbd-300c20644bf9\", \"shortName\": \"ABB\", \"dateUpdated\": \"2025-10-20T16:56:32.337Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2025-9574\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-10-20T17:32:51.170Z\", \"dateReserved\": \"2025-08-28T10:04:01.947Z\", \"assignerOrgId\": \"2b718523-d88f-4f37-9bbd-300c20644bf9\", \"datePublished\": \"2025-10-20T16:56:32.337Z\", \"assignerShortName\": \"ABB\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.