CVE-2025-54497 (GCVE-0-2025-54497)
Vulnerability from cvelistv5
Published
2025-09-18 21:24
Modified
2025-09-18 21:24
CWE
Summary
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 to allow management operations such as firmware upgrades and device reboots, which require authentication. A user with protected privileges can successfully invoke the SetSerialPort functionality to modify relevant device properties (such as serial interface settings), contradicting the security model proposed in the user manual.
Show details on NVD website


{
  "containers": {
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "In-Sight 2000 series",
          "vendor": "Cognex",
          "versions": [
            {
              "lessThanOrEqual": "6.5.1",
              "status": "affected",
              "version": "5.x",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "In-Sight 7000 series",
          "vendor": "Cognex",
          "versions": [
            {
              "lessThanOrEqual": "6.5.1",
              "status": "affected",
              "version": "5.x",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "In-Sight 8000 series",
          "vendor": "Cognex",
          "versions": [
            {
              "lessThanOrEqual": "6.5.1",
              "status": "affected",
              "version": "5.x",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "In-Sight 9000 series",
          "vendor": "Cognex",
          "versions": [
            {
              "lessThanOrEqual": "6.5.1",
              "status": "affected",
              "version": "5.x",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "In-Sight Explorer",
          "vendor": "Cognex",
          "versions": [
            {
              "lessThanOrEqual": "6.5.1",
              "status": "affected",
              "version": "5.x",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Diego Giubertoni of Nozomi Networks reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Cognex In-Sight Explorer and In-Sight Camera Firmware expose \na telnet-based service \non port 23 to allow management operations such as firmware upgrades and \ndevice reboots, which require authentication. A user with protected \nprivileges can successfully invoke the SetSerialPort functionality to \nmodify relevant device properties (such as serial interface settings), \ncontradicting the security model proposed in the user manual."
            }
          ],
          "value": "Cognex In-Sight Explorer and In-Sight Camera Firmware expose \na telnet-based service \non port 23 to allow management operations such as firmware upgrades and \ndevice reboots, which require authentication. A user with protected \nprivileges can successfully invoke the SetSerialPort functionality to \nmodify relevant device properties (such as serial interface settings), \ncontradicting the security model proposed in the user manual."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-732",
              "description": "CWE-732",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-18T21:24:05.023Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-06"
        }
      ],
      "source": {
        "advisory": "ICSA-25-261-06",
        "discovery": "EXTERNAL"
      },
      "title": "Cognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Permission Assignment for Critical Resource",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Cognex reports that In-Sight Explorer based vision systems are legacy \nproducts not intended for new applications. To reduce risk, asset owners\n are advised to switch to next generation In-Sight Vision Suite based \nvision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 \nseries embedded cameras.\n\n\u003cbr\u003e"
            }
          ],
          "value": "Cognex reports that In-Sight Explorer based vision systems are legacy \nproducts not intended for new applications. To reduce risk, asset owners\n are advised to switch to next generation In-Sight Vision Suite based \nvision systems, such as the In-Sight 2800, In-Sight 3800, In-Sight 8900 \nseries embedded cameras."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-54497",
    "datePublished": "2025-09-18T21:24:05.023Z",
    "dateReserved": "2025-08-06T16:32:41.300Z",
    "dateUpdated": "2025-09-18T21:24:05.023Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-54497\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2025-09-18T22:15:46.227\",\"lastModified\":\"2025-09-18T22:15:46.227\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Cognex In-Sight Explorer and In-Sight Camera Firmware expose \\na telnet-based service \\non port 23 to allow management operations such as firmware upgrades and \\ndevice reboots, which require authentication. A user with protected \\nprivileges can successfully invoke the SetSerialPort functionality to \\nmodify relevant device properties (such as serial interface settings), \\ncontradicting the security model proposed in the user manual.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.2}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-732\"}]}],\"references\":[{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-06\",\"source\":\"ics-cert@hq.dhs.gov\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…