CVE-2025-30519 (GCVE-0-2025-30519)
Vulnerability from cvelistv5
Published
2025-09-18 20:46
Modified
2025-09-19 13:05
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.3 (Critical) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
9.3 (Critical) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
VLAI Severity ?
EPSS score ?
CWE
Summary
Dover Fueling Solutions ProGauge MagLink LX4 Devices have default root credentials that cannot be changed through standard
administrative means. An attacker with network access to the device can
gain administrative access to the system.
References
Impacted products
Vendor | Product | Version | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Dover Fueling Solutions | ProGauge MagLink LX 4 |
Version: 0 < 4.20.3 |
|||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-30519", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-09-19T13:05:08.342046Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-09-19T13:05:20.889Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "ProGauge MagLink LX 4", "vendor": "Dover Fueling Solutions", "versions": [ { "lessThan": "4.20.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ProGauge MagLink LX Plus", "vendor": "Dover Fueling Solutions", "versions": [ { "lessThan": "4.20.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ProGauge MagLink LX Ultimate", "vendor": "Dover Fueling Solutions", "versions": [ { "lessThan": "5.20.3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Pedro Umbelino of Bitsight TRACE reported these vulnerabilities to CISA." } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Dover Fueling Solutions ProGauge MagLink LX4 Devices\u0026nbsp;have default root credentials that cannot be changed through standard \nadministrative means. An attacker with network access to the device can \ngain administrative access to the system." } ], "value": "Dover Fueling Solutions ProGauge MagLink LX4 Devices\u00a0have default root credentials that cannot be changed through standard \nadministrative means. An attacker with network access to the device can \ngain administrative access to the system." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] }, { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 9.3, "baseSeverity": "CRITICAL", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1391", "description": "CWE-1391", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-09-18T20:46:42.642Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-07" }, { "url": "https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html\"\u003ewebsite\u003c/a\u003e\u0026nbsp;.\u003cp\u003eFor MagLink LX Ultimate devices, Dover Fueling Solutions recommends users \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-ultimate-console.html\"\u003eupdate to version 5.20.3\u003c/a\u003e\u0026nbsp;or later.\u003c/p\u003e\n\u003cp\u003eDover Fueling Solutions recommends all users install the software behind a firewall to minimize risk of remote attacks.\u003c/p\u003e\n\n\u003cbr\u003e" } ], "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions website https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html \u00a0.For MagLink LX Ultimate devices, Dover Fueling Solutions recommends users update to version 5.20.3 https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-ultimate-console.html \u00a0or later.\n\n\nDover Fueling Solutions recommends all users install the software behind a firewall to minimize risk of remote attacks." } ], "source": { "advisory": "ICSA-25-261-07", "discovery": "EXTERNAL" }, "title": "Dover Fueling Solutions ProGauge MagLink LX4 Devices Use of Weak Credentials", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2025-30519", "datePublished": "2025-09-18T20:46:42.642Z", "dateReserved": "2025-08-18T15:32:05.607Z", "dateUpdated": "2025-09-19T13:05:20.889Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2025-30519\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2025-09-18T21:15:47.553\",\"lastModified\":\"2025-09-19T16:00:27.847\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dover Fueling Solutions ProGauge MagLink LX4 Devices\u00a0have default root credentials that cannot be changed through standard \\nadministrative means. An attacker with network access to the device can \\ngain administrative access to the system.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":9.3,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-1391\"}]}],\"references\":[{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-07\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html\",\"source\":\"ics-cert@hq.dhs.gov\"}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-30519\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-09-19T13:05:08.342046Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-09-19T13:05:13.315Z\"}}], \"cna\": {\"title\": \"Dover Fueling Solutions ProGauge MagLink LX4 Devices Use of Weak Credentials\", \"source\": {\"advisory\": \"ICSA-25-261-07\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Pedro Umbelino of Bitsight TRACE reported these vulnerabilities to CISA.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 9.3, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Dover Fueling Solutions\", \"product\": \"ProGauge MagLink LX 4\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"4.20.3\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Dover Fueling Solutions\", \"product\": \"ProGauge MagLink LX Plus\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"4.20.3\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Dover Fueling Solutions\", \"product\": \"ProGauge MagLink LX Ultimate\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"5.20.3\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Dover Fueling Solutions recommends users update their ProGauge MagLink \\ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \\nmodels. The upgrade can be downloaded from the Dover Fueling Solutions website https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html \\u00a0.For MagLink LX Ultimate devices, Dover Fueling Solutions recommends users update to version 5.20.3 https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-ultimate-console.html \\u00a0or later.\\n\\n\\nDover Fueling Solutions recommends all users install the software behind a firewall to minimize risk of remote attacks.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Dover Fueling Solutions recommends users update their ProGauge MagLink \\ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \\nmodels. The upgrade can be downloaded from the Dover Fueling Solutions \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html\\\"\u003ewebsite\u003c/a\u003e\u0026nbsp;.\u003cp\u003eFor MagLink LX Ultimate devices, Dover Fueling Solutions recommends users \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-ultimate-console.html\\\"\u003eupdate to version 5.20.3\u003c/a\u003e\u0026nbsp;or later.\u003c/p\u003e\\n\u003cp\u003eDover Fueling Solutions recommends all users install the software behind a firewall to minimize risk of remote attacks.\u003c/p\u003e\\n\\n\u003cbr\u003e\", \"base64\": false}]}], \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-25-261-07\"}, {\"url\": \"https://www.doverfuelingsolutions.com/mea/en/products-and-solutions/automatic-tank-gauging/consoles/progauge-maglink-lx-4-console.html\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Dover Fueling Solutions ProGauge MagLink LX4 Devices\\u00a0have default root credentials that cannot be changed through standard \\nadministrative means. An attacker with network access to the device can \\ngain administrative access to the system.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Dover Fueling Solutions ProGauge MagLink LX4 Devices\u0026nbsp;have default root credentials that cannot be changed through standard \\nadministrative means. An attacker with network access to the device can \\ngain administrative access to the system.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-1391\", \"description\": \"CWE-1391\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2025-09-18T20:46:42.642Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2025-30519\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-09-19T13:05:20.889Z\", \"dateReserved\": \"2025-08-18T15:32:05.607Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2025-09-18T20:46:42.642Z\", \"assignerShortName\": \"icscert\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…