CVE-2025-23260 (GCVE-0-2025-23260)
Vulnerability from cvelistv5
Published
2025-06-24 17:28
Modified
2025-06-24 18:09
CWE
  • CWE-266 - Incorrect Privilege Assignment
Summary
NVIDIA AIStore contains a vulnerability in the AIS Operator where a user may gain elevated k8s cluster access by using the ServiceAccount attached to the ClusterRole. A successful exploit of this vulnerability may lead to information disclosure.
Impacted products
Vendor Product Version
NVIDIA AIStore Version: All versions prior 2.3.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-23260",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-24T18:08:47.039752Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-24T18:09:56.253Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Kubernetes"
          ],
          "product": "AIStore",
          "vendor": "NVIDIA",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior 2.3.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "NVIDIA AIStore contains a vulnerability in the AIS Operator where a user may gain elevated k8s cluster access by using the ServiceAccount attached to the ClusterRole. A successful exploit of this vulnerability may lead to information disclosure."
            }
          ],
          "value": "NVIDIA AIStore contains a vulnerability in the AIS Operator where a user may gain elevated k8s cluster access by using the ServiceAccount attached to the ClusterRole. A successful exploit of this vulnerability may lead to information disclosure."
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Information disclosure"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-266",
              "description": "CWE-266: Incorrect Privilege Assignment",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-24T17:29:27.268Z",
        "orgId": "9576f279-3576-44b5-a4af-b9a8644b2de6",
        "shortName": "nvidia"
      },
      "references": [
        {
          "url": "https://nvidia.custhelp.com/app/answers/detail/a_id/5660"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9576f279-3576-44b5-a4af-b9a8644b2de6",
    "assignerShortName": "nvidia",
    "cveId": "CVE-2025-23260",
    "datePublished": "2025-06-24T17:28:40.319Z",
    "dateReserved": "2025-01-14T01:06:22.263Z",
    "dateUpdated": "2025-06-24T18:09:56.253Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-23260\",\"sourceIdentifier\":\"psirt@nvidia.com\",\"published\":\"2025-06-24T18:15:24.533\",\"lastModified\":\"2025-12-15T18:50:24.243\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"NVIDIA AIStore contains a vulnerability in the AIS Operator where a user may gain elevated k8s cluster access by using the ServiceAccount attached to the ClusterRole. A successful exploit of this vulnerability may lead to information disclosure.\"},{\"lang\":\"es\",\"value\":\"NVIDIA AIStore contiene una vulnerabilidad en el operador AIS que permite a un usuario obtener acceso elevado al cl\u00faster k8s mediante la cuenta de servicio asociada al rol de cl\u00faster. Explotar esta vulnerabilidad podr\u00eda provocar la divulgaci\u00f3n de informaci\u00f3n.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@nvidia.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N\",\"baseScore\":5.0,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.1,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"psirt@nvidia.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-266\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:nvidia:aistore:*:*:*:*:*:kubernetes:*:*\",\"versionEndExcluding\":\"2.3.0\",\"matchCriteriaId\":\"B5F035C3-7B61-4BF8-933B-0D85DBE9ADFC\"}]}]}],\"references\":[{\"url\":\"https://nvidia.custhelp.com/app/answers/detail/a_id/5660\",\"source\":\"psirt@nvidia.com\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-23260\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-06-24T18:08:47.039752Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-06-24T18:08:48.784Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"descriptions\": [{\"lang\": \"en\", \"value\": \"Information disclosure\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"NVIDIA\", \"product\": \"AIStore\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions prior 2.3.0\"}], \"platforms\": [\"Kubernetes\"], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://nvidia.custhelp.com/app/answers/detail/a_id/5660\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"NVIDIA AIStore contains a vulnerability in the AIS Operator where a user may gain elevated k8s cluster access by using the ServiceAccount attached to the ClusterRole. A successful exploit of this vulnerability may lead to information disclosure.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"NVIDIA AIStore contains a vulnerability in the AIS Operator where a user may gain elevated k8s cluster access by using the ServiceAccount attached to the ClusterRole. A successful exploit of this vulnerability may lead to information disclosure.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-266\", \"description\": \"CWE-266: Incorrect Privilege Assignment\"}]}], \"providerMetadata\": {\"orgId\": \"9576f279-3576-44b5-a4af-b9a8644b2de6\", \"shortName\": \"nvidia\", \"dateUpdated\": \"2025-06-24T17:29:27.268Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-23260\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-06-24T18:09:56.253Z\", \"dateReserved\": \"2025-01-14T01:06:22.263Z\", \"assignerOrgId\": \"9576f279-3576-44b5-a4af-b9a8644b2de6\", \"datePublished\": \"2025-06-24T17:28:40.319Z\", \"assignerShortName\": \"nvidia\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…