CVE-2025-12896 (GCVE-0-2025-12896)
Vulnerability from cvelistv5
Published
2025-11-07 20:24
Modified
2025-11-07 20:40
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-307 - Improper Restriction of Excessive Authentication Attempts
Summary
Improper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Solidigm™ | D5-P5316, D7-P5510, D7-P5520/D7-P5620, D5-P5430, D5-P5336 |
Version: All FW prior to ACV10360 Version: All FW prior to JCV10501 Version: All FW prior to 9CV10490 Version: All FW prior to 6DV10341 (8K IU) / 6CV10241 (4K IU) Version: All FW prior to 5CV10326 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-12896",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-11-07T20:39:53.655558Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-11-07T20:40:07.108Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "D5-P5316, D7-P5510, D7-P5520/D7-P5620, D5-P5430, D5-P5336",
"vendor": "Solidigm\u2122",
"versions": [
{
"status": "affected",
"version": "All FW prior to ACV10360"
},
{
"status": "affected",
"version": "All FW prior to JCV10501"
},
{
"status": "affected",
"version": "All FW prior to 9CV10490"
},
{
"status": "affected",
"version": "All FW prior to 6DV10341 (8K IU) / 6CV10241 (4K IU)"
},
{
"status": "affected",
"version": "All FW prior to 5CV10326"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eImproper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device.\u003c/span\u003e\u003cbr\u003e"
}
],
"value": "Improper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device."
}
],
"impacts": [
{
"capecId": "CAPEC-114",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-114 Authentication Abuse"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-307",
"description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-07T20:24:11.186Z",
"orgId": "f946a70c-00eb-42ce-8e9b-634d1f7b5a6f",
"shortName": "Solidigm"
},
"references": [
{
"url": "https://www.solidigm.com/support-page/support-security.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f946a70c-00eb-42ce-8e9b-634d1f7b5a6f",
"assignerShortName": "Solidigm",
"cveId": "CVE-2025-12896",
"datePublished": "2025-11-07T20:24:11.186Z",
"dateReserved": "2025-11-07T18:56:03.627Z",
"dateUpdated": "2025-11-07T20:40:07.108Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-12896\",\"sourceIdentifier\":\"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\",\"published\":\"2025-11-07T21:15:40.750\",\"lastModified\":\"2025-11-07T21:15:40.750\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":4.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":0.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-307\"}]}],\"references\":[{\"url\":\"https://www.solidigm.com/support-page/support-security.html\",\"source\":\"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-12896\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-11-07T20:39:53.655558Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-11-07T20:39:58.336Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"capecId\": \"CAPEC-114\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-114 Authentication Abuse\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 4.4, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Solidigm\\u2122\", \"product\": \"D5-P5316, D7-P5510, D7-P5520/D7-P5620, D5-P5430, D5-P5336\", \"versions\": [{\"status\": \"affected\", \"version\": \"All FW prior to ACV10360\"}, {\"status\": \"affected\", \"version\": \"All FW prior to JCV10501\"}, {\"status\": \"affected\", \"version\": \"All FW prior to 9CV10490\"}, {\"status\": \"affected\", \"version\": \"All FW prior to 6DV10341 (8K IU) / 6CV10241 (4K IU)\"}, {\"status\": \"affected\", \"version\": \"All FW prior to 5CV10326\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.solidigm.com/support-page/support-security.html\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.5.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Improper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eImproper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device.\u003c/span\u003e\u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-307\", \"description\": \"CWE-307 Improper Restriction of Excessive Authentication Attempts\"}]}], \"providerMetadata\": {\"orgId\": \"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\", \"shortName\": \"Solidigm\", \"dateUpdated\": \"2025-11-07T20:24:11.186Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-12896\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-11-07T20:40:07.108Z\", \"dateReserved\": \"2025-11-07T18:56:03.627Z\", \"assignerOrgId\": \"f946a70c-00eb-42ce-8e9b-634d1f7b5a6f\", \"datePublished\": \"2025-11-07T20:24:11.186Z\", \"assignerShortName\": \"Solidigm\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…