CVE-2024-8957
Vulnerability from cvelistv5
Published
2024-09-17 20:08
Modified
2024-11-04 17:20
Severity ?
EPSS score ?
Summary
PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.
References
▼ | URL | Tags | |
---|---|---|---|
disclosure@vulncheck.com | https://ptzoptics.com/firmware-changelog/ | Release Notes | |
disclosure@vulncheck.com | https://vulncheck.com/advisories/ptzoptics-command-injection | Third Party Advisory |
Impacted products
CISA Known exploited vulnerability
Data from the Known Exploited Vulnerabilities Catalog
Date added: 2024-11-04
Due date: 2024-11-25
Required action: Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.
Used in ransomware: Unknown
Notes: https://ptzoptics.com/firmware-changelog/ ; https://nvd.nist.gov/vuln/detail/CVE-2024-8957
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "pt30x-sdi_firmware", "vendor": "ptzoptics", "versions": [ { "lessThan": "6.3.40", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "cpes": [ "cpe:2.3:o:ptzoptics:pt30x-ndi_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "pt30x-ndi_firmware", "vendor": "ptzoptics", "versions": [ { "lessThan": "6.3.40", "status": "affected", "version": "0", "versionType": "semver" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-8957", "options": [ { "Exploitation": "active" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-04T16:04:10.696120Z", "version": "2.0.3" }, "type": "ssvc" } }, { "other": { "content": { "dateAdded": "2024-11-04", "reference": "https://www.cisa.gov/sites/default/files/feeds/known_exploited_vulnerabilities.json" }, "type": "kev" } } ], "providerMetadata": { "dateUpdated": "2024-11-04T17:20:22.792Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "timeline": [ { "lang": "en", "time": "2024-11-04T00:00:00+00:00", "value": "CVE-2024-8957 added to CISA KEV" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "PT30X-SDI", "vendor": "PTZOptics", "versions": [ { "lessThan": "6.3.40", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PT30X-NDI", "vendor": "PTZOptics", "versions": [ { "lessThan": "6.3.40", "status": "affected", "version": "0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Konstantin Lazarev of GreyNoise" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.\u003cbr\u003e" } ], "value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices." } ], "impacts": [ { "capecId": "CAPEC-88", "descriptions": [ { "lang": "en", "value": "CAPEC-88 OS Command Injection" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-17T20:08:25.588Z", "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10", "shortName": "VulnCheck" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://ptzoptics.com/firmware-changelog/" }, { "tags": [ "third-party-advisory" ], "url": "https://vulncheck.com/advisories/ptzoptics-command-injection" } ], "source": { "discovery": "UNKNOWN" }, "tags": [ "x_known-exploited-vulnerability" ], "title": "PTZOptics NDI and SDI Cameras Command Injection via NTP Address Configuration", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10", "assignerShortName": "VulnCheck", "cveId": "CVE-2024-8957", "datePublished": "2024-09-17T20:08:25.588Z", "dateReserved": "2024-09-17T19:08:48.129Z", "dateUpdated": "2024-11-04T17:20:22.792Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "cisa_known_exploited": { "cveID": "CVE-2024-8957", "cwes": "[\"CWE-78\"]", "dateAdded": "2024-11-04", "dueDate": "2024-11-25", "knownRansomwareCampaignUse": "Unknown", "notes": "https://ptzoptics.com/firmware-changelog/ ; https://nvd.nist.gov/vuln/detail/CVE-2024-8957", "product": "PT30X-SDI/NDI Cameras", "requiredAction": "Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.", "shortDescription": "PTZOptics PT30X-SDI/NDI cameras contain an OS command injection vulnerability that allows a remote, authenticated attacker to escalate privileges to root via a crafted payload with the ntp_addr parameter of the /cgi-bin/param.cgi CGI script. ", "vendorProject": "PTZOptics", "vulnerabilityName": "PTZOptics PT30X-SDI/NDI Cameras OS Command Injection Vulnerability" }, "nvd": "{\"cve\":{\"id\":\"CVE-2024-8957\",\"sourceIdentifier\":\"disclosure@vulncheck.com\",\"published\":\"2024-09-17T21:15:13.423\",\"lastModified\":\"2024-11-05T02:00:01.697\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.\"},{\"lang\":\"es\",\"value\":\"PTZOptics PT30X-SDI/NDI-xx anterior al firmware 6.3.40 es vulnerable a un problema de inyecci\u00f3n de comandos del sistema operativo. La c\u00e1mara no valida suficientemente el valor de configuraci\u00f3n ntp_addr, lo que puede provocar la ejecuci\u00f3n de comandos arbitrarios cuando se inicia ntp_client. Cuando se combina con CVE-2024-8956, un atacante remoto y no autenticado puede ejecutar comandos arbitrarios del sistema operativo en los dispositivos afectados.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"disclosure@vulncheck.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"cisaExploitAdd\":\"2024-11-04\",\"cisaActionDue\":\"2024-11-25\",\"cisaRequiredAction\":\"Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.\",\"cisaVulnerabilityName\":\"PTZOptics PT30X-SDI/NDI Cameras OS Command Injection Vulnerability\",\"weaknesses\":[{\"source\":\"disclosure@vulncheck.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.3.40\",\"matchCriteriaId\":\"604C6EEF-4273-4366-AFF2-86C3183F545D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ptzoptics:pt30x-sdi:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7462D89D-2105-417F-AB0E-D23C288156C8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ptzoptics:pt30x-ndi-xx-g2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.3.40\",\"matchCriteriaId\":\"B410E242-DFEE-449D-9687-6F4D0BEB8F63\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ptzoptics:pt30x-ndi-xx-g2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C8F75E95-D59D-45D4-B798-D0493642F53E\"}]}]}],\"references\":[{\"url\":\"https://ptzoptics.com/firmware-changelog/\",\"source\":\"disclosure@vulncheck.com\",\"tags\":[\"Release Notes\"]},{\"url\":\"https://vulncheck.com/advisories/ptzoptics-command-injection\",\"source\":\"disclosure@vulncheck.com\",\"tags\":[\"Third Party Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.