CVE-2024-48989
Vulnerability from cvelistv5
Published
2024-11-13 13:39
Modified
2024-11-13 14:37
Summary
A vulnerability in the PROFINET stack implementation of the IndraDrive (all versions) of Bosch Rexroth allows an attacker to cause a denial of service, rendering the device unresponsive by sending arbitrary UDP messages.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:boschrexrothag:indradrive_fwa_indrv_mp:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "indradrive_fwa_indrv_mp",
            "vendor": "boschrexrothag",
            "versions": [
              {
                "lessThan": "20v36",
                "status": "affected",
                "version": "17vrs",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-48989",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-13T14:28:10.398256Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-770",
                "description": "CWE-770 Allocation of Resources Without Limits or Throttling",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-13T14:37:07.826Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "IndraDrive FWA-INDRV*-MP*",
          "vendor": "Bosch Rexroth AG",
          "versions": [
            {
              "lessThan": "20V36",
              "status": "affected",
              "version": "17VRS",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the PROFINET stack implementation of the IndraDrive (all versions) of Bosch Rexroth allows an attacker to cause a denial of service, rendering the device unresponsive by sending arbitrary UDP messages."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400 Uncontrolled Resource Consumption",
              "lang": "en-US"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-13T13:39:15.659Z",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-315415.html",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-315415.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2024-48989",
    "datePublished": "2024-11-13T13:39:15.659Z",
    "dateReserved": "2024-10-11T12:12:25.507Z",
    "dateUpdated": "2024-11-13T14:37:07.826Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-48989\",\"sourceIdentifier\":\"psirt@bosch.com\",\"published\":\"2024-11-13T14:15:15.417\",\"lastModified\":\"2024-11-13T17:01:16.850\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the PROFINET stack implementation of the IndraDrive (all versions) of Bosch Rexroth allows an attacker to cause a denial of service, rendering the device unresponsive by sending arbitrary UDP messages.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la implementaci\u00f3n de la pila PROFINET del IndraDrive (todas las versiones) de Bosch Rexroth permite a un atacante provocar una denegaci\u00f3n de servicio, dejando el dispositivo sin respuesta mediante el env\u00edo de mensajes UDP arbitrarios.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@bosch.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"psirt@bosch.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-770\"}]}],\"references\":[{\"url\":\"https://psirt.bosch.com/security-advisories/BOSCH-SA-315415.html\",\"source\":\"psirt@bosch.com\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.