CVE-2024-35293 (GCVE-0-2024-35293)
Vulnerability from cvelistv5 – Published: 2024-10-02 09:51 – Updated: 2024-10-02 14:48
VLAI?
Title
Schneider Elektronik Series 700 prone to missing authentication for critical reset function
Summary
An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS.
Severity ?
9.1 (Critical)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Elektronik | Series 700 |
Affected:
0.0.0.0 , ≤ 0.1.17.6
(custom)
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-35293",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-02T14:46:56.834735Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-02T14:48:19.675Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Series 700",
"vendor": "Schneider Elektronik",
"versions": [
{
"lessThanOrEqual": "0.1.17.6",
"status": "affected",
"version": "0.0.0.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Felix Eberstaller and David Schauer from Limes Security"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS."
}
],
"value": "An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-02T09:51:01.799Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.schneider-elektronik.de/wp-content/uploads/2024/07/SAR-202405-1.pdf"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Schneider Elektronik Series 700 prone to missing authentication for critical reset function",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-35293",
"datePublished": "2024-10-02T09:51:01.799Z",
"dateReserved": "2024-05-15T12:37:05.393Z",
"dateUpdated": "2024-10-02T14:48:19.675Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-35293",
"date": "2026-05-09",
"epss": "0.0191",
"percentile": "0.83426"
},
"fkie_nvd": {
"descriptions": "[{\"lang\": \"en\", \"value\": \"An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS.\"}, {\"lang\": \"es\", \"value\": \"Un atacante remoto no autenticado puede usar una vulnerabilidad de autenticaci\\u00f3n faltante para una funci\\u00f3n cr\\u00edtica para reiniciar o borrar los dispositivos afectados, lo que resulta en p\\u00e9rdida de datos y/o un DoS.\"}]",
"id": "CVE-2024-35293",
"lastModified": "2024-10-04T13:50:43.727",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"info@cert.vde.com\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H\", \"baseScore\": 9.1, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.2}]}",
"published": "2024-10-02T10:15:03.160",
"references": "[{\"url\": \"https://www.schneider-elektronik.de/wp-content/uploads/2024/07/SAR-202405-1.pdf\", \"source\": \"info@cert.vde.com\"}]",
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": "[{\"source\": \"info@cert.vde.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-306\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-35293\",\"sourceIdentifier\":\"info@cert.vde.com\",\"published\":\"2024-10-02T10:15:03.160\",\"lastModified\":\"2024-10-04T13:50:43.727\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS.\"},{\"lang\":\"es\",\"value\":\"Un atacante remoto no autenticado puede usar una vulnerabilidad de autenticaci\u00f3n faltante para una funci\u00f3n cr\u00edtica para reiniciar o borrar los dispositivos afectados, lo que resulta en p\u00e9rdida de datos y/o un DoS.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.2}]},\"weaknesses\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"references\":[{\"url\":\"https://www.schneider-elektronik.de/wp-content/uploads/2024/07/SAR-202405-1.pdf\",\"source\":\"info@cert.vde.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-35293\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-10-02T14:46:56.834735Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-10-02T14:48:13.893Z\"}}], \"cna\": {\"title\": \"Schneider Elektronik Series 700 prone to missing authentication for critical reset function\", \"source\": {\"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"Felix Eberstaller and David Schauer from Limes Security\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.1, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Schneider Elektronik\", \"product\": \"Series 700\", \"versions\": [{\"status\": \"affected\", \"version\": \"0.0.0.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"0.1.17.6\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.schneider-elektronik.de/wp-content/uploads/2024/07/SAR-202405-1.pdf\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-306\", \"description\": \"CWE-306: Missing Authentication for Critical Function\"}]}], \"providerMetadata\": {\"orgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"shortName\": \"CERTVDE\", \"dateUpdated\": \"2024-10-02T09:51:01.799Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-35293\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-10-02T14:48:19.675Z\", \"dateReserved\": \"2024-05-15T12:37:05.393Z\", \"assignerOrgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"datePublished\": \"2024-10-02T09:51:01.799Z\", \"assignerShortName\": \"CERTVDE\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…