GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2024-35293 (GCVE-0-2024-35293)

Vulnerability from cvelistv5 – Published: 2024-10-02 09:51 – Updated: 2024-10-02 14:48
VLAI
Title
Schneider Elektronik Series 700 prone to missing authentication for critical reset function
Summary
An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-02 14:46 UTC
CWE
  • CWE-306 - Missing Authentication for Critical Function
References
Impacted products
Vendor Product Version CPE status
Schneider Elektronik Series 700 Affected: 0.0.0.0 , ≤ 0.1.17.6 (custom)
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-35293",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-02T14:46:56.834735Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-02T14:48:19.675Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Series 700",
          "vendor": "Schneider Elektronik",
          "versions": [
            {
              "lessThanOrEqual": "0.1.17.6",
              "status": "affected",
              "version": "0.0.0.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Felix Eberstaller and David Schauer from Limes Security"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS."
            }
          ],
          "value": "An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-02T09:51:01.799Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.schneider-elektronik.de/wp-content/uploads/2024/07/SAR-202405-1.pdf"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Schneider Elektronik Series 700 prone to missing authentication for critical reset function",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2024-35293",
    "datePublished": "2024-10-02T09:51:01.799Z",
    "dateReserved": "2024-05-15T12:37:05.393Z",
    "dateUpdated": "2024-10-02T14:48:19.675Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-35293",
      "date": "2026-09-16",
      "epss": "0.00625",
      "percentile": "0.48333"
    },
    "fkie_nvd": {
      "descriptions": "[{\"lang\": \"en\", \"value\": \"An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS.\"}, {\"lang\": \"es\", \"value\": \"Un atacante remoto no autenticado puede usar una vulnerabilidad de autenticaci\\u00f3n faltante para una funci\\u00f3n cr\\u00edtica para reiniciar o borrar los dispositivos afectados, lo que resulta en p\\u00e9rdida de datos y/o un DoS.\"}]",
      "id": "CVE-2024-35293",
      "lastModified": "2024-10-04T13:50:43.727",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"info@cert.vde.com\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H\", \"baseScore\": 9.1, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.2}]}",
      "published": "2024-10-02T10:15:03.160",
      "references": "[{\"url\": \"https://www.schneider-elektronik.de/wp-content/uploads/2024/07/SAR-202405-1.pdf\", \"source\": \"info@cert.vde.com\"}]",
      "sourceIdentifier": "info@cert.vde.com",
      "vulnStatus": "Awaiting Analysis",
      "weaknesses": "[{\"source\": \"info@cert.vde.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-306\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-35293\",\"sourceIdentifier\":\"info@cert.vde.com\",\"published\":\"2024-10-02T10:15:03.160\",\"lastModified\":\"2026-06-17T07:34:42.220\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS.\"},{\"lang\":\"es\",\"value\":\"Un atacante remoto no autenticado puede usar una vulnerabilidad de autenticaci\u00f3n faltante para una funci\u00f3n cr\u00edtica para reiniciar o borrar los dispositivos afectados, lo que resulta en p\u00e9rdida de datos y/o un DoS.\"}],\"affected\":[{\"source\":\"info@cert.vde.com\",\"affectedData\":[{\"vendor\":\"Schneider Elektronik\",\"product\":\"Series 700\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0.0.0.0\",\"lessThanOrEqual\":\"0.1.17.6\",\"versionType\":\"custom\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.2}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2024-10-02T14:46:56.834735Z\",\"id\":\"CVE-2024-35293\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"partial\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"references\":[{\"url\":\"https://www.schneider-elektronik.de/wp-content/uploads/2024/07/SAR-202405-1.pdf\",\"source\":\"info@cert.vde.com\"}]}}",
    "redhat_vex": {
      "current_release_date": "2025-05-28T19:31:24+00:00",
      "cve": "CVE-2024-35293",
      "id": "CVE-2024-35293",
      "initial_release_date": "2024-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Schneider Elektronik Series 700 prone to missing authentication for critical reset function",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-35293.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-35293\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-10-02T14:46:56.834735Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-10-02T14:48:13.893Z\"}}], \"cna\": {\"title\": \"Schneider Elektronik Series 700 prone to missing authentication for critical reset function\", \"source\": {\"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"Felix Eberstaller and David Schauer from Limes Security\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.1, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Schneider Elektronik\", \"product\": \"Series 700\", \"versions\": [{\"status\": \"affected\", \"version\": \"0.0.0.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"0.1.17.6\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.schneider-elektronik.de/wp-content/uploads/2024/07/SAR-202405-1.pdf\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-306\", \"description\": \"CWE-306: Missing Authentication for Critical Function\"}]}], \"providerMetadata\": {\"orgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"shortName\": \"CERTVDE\", \"dateUpdated\": \"2024-10-02T09:51:01.799Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-35293\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-10-02T14:48:19.675Z\", \"dateReserved\": \"2024-05-15T12:37:05.393Z\", \"assignerOrgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"datePublished\": \"2024-10-02T09:51:01.799Z\", \"assignerShortName\": \"CERTVDE\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…