CVE-2023-50440 (GCVE-0-2023-50440)
Vulnerability from cvelistv5
Published
2023-12-13 00:00
Modified
2025-06-03 13:43
CWE
  • n/a
Summary
ZED containers produced by PRIMX ZED! for Windows before Q.2020.3 (ANSSI qualification submission); ZED! for Windows before Q.2021.2 (ANSSI qualification submission); ZONECENTRAL for Windows before Q.2021.2 (ANSSI qualification submission); ZONECENTRAL for Windows before 2023.5; ZEDMAIL for Windows before 2023.5; ZED! for Windows, Mac, Linux before 2023.5; ZEDFREE for Windows, Mac, Linux before 2023.5; or ZEDPRO for Windows, Mac, Linux before 2023.5 can be modified by an unauthenticated attacker to include a UNC reference so that it could trigger network access to an attacker-controlled computer when opened by the victim.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T22:16:46.889Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.primx.eu/fr/blog/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.primx.eu/en/bulletins/security-bulletin-23B30931/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 5.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-50440",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-22T18:27:33.353117Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-284",
                "description": "CWE-284 Improper Access Control",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-03T13:43:44.490Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "ZED containers produced by PRIMX ZED! for Windows before Q.2020.3 (ANSSI qualification submission); ZED! for Windows before Q.2021.2 (ANSSI qualification submission); ZONECENTRAL for Windows before Q.2021.2 (ANSSI qualification submission); ZONECENTRAL for Windows before 2023.5; ZEDMAIL for Windows before 2023.5; ZED! for Windows, Mac, Linux before 2023.5; ZEDFREE for Windows, Mac, Linux before 2023.5; or ZEDPRO for Windows, Mac, Linux before 2023.5 can be modified by an unauthenticated attacker to include a UNC reference so that it could trigger network access to an attacker-controlled computer when opened by the victim."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-12-13T20:28:25.568Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.primx.eu/fr/blog/"
        },
        {
          "url": "https://www.primx.eu/en/bulletins/security-bulletin-23B30931/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-50440",
    "datePublished": "2023-12-13T00:00:00.000Z",
    "dateReserved": "2023-12-10T00:00:00.000Z",
    "dateUpdated": "2025-06-03T13:43:44.490Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-50440\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2023-12-13T21:15:09.610\",\"lastModified\":\"2025-06-03T14:15:33.780\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"ZED containers produced by PRIMX ZED! for Windows before Q.2020.3 (ANSSI qualification submission); ZED! for Windows before Q.2021.2 (ANSSI qualification submission); ZONECENTRAL for Windows before Q.2021.2 (ANSSI qualification submission); ZONECENTRAL for Windows before 2023.5; ZEDMAIL for Windows before 2023.5; ZED! for Windows, Mac, Linux before 2023.5; ZEDFREE for Windows, Mac, Linux before 2023.5; or ZEDPRO for Windows, Mac, Linux before 2023.5 can be modified by an unauthenticated attacker to include a UNC reference so that it could trigger network access to an attacker-controlled computer when opened by the victim.\"},{\"lang\":\"es\",\"value\":\"Contenedores ZED producidos por PRIMX ZED! para Windows anteriores a Q.2020.3 (presentaci\u00f3n de calificaci\u00f3n ANSSI); ZED! para Windows anteriores a Q.2021.2 (presentaci\u00f3n de calificaci\u00f3n ANSSI); ZONECENTRAL para Windows antes de Q.2021.2 (presentaci\u00f3n de calificaci\u00f3n ANSSI); ZONECENTRAL para Windows antes de 2023.5; ZEDMAIL para Windows antes de 2023.5; ZED! para Windows, Mac, Linux antes de 2023.5; ZEDFREE para Windows, Mac, Linux antes de 2023.5; o ZEDPRO para Windows, Mac, Linux anterior a 2023.5 puede ser modificado por un atacante no autenticado para incluir una referencia UNC de modo que pueda activar el acceso a la red a una maquina controlada por el atacante cuando la v\u00edctima la abra.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:primx:zed\\\\!:*:*:*:*:enterprise:linux:*:*\",\"versionEndExcluding\":\"2023.5\",\"matchCriteriaId\":\"CC444405-D58E-42B4-A1EF-1EF4F0CC6300\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:primx:zed\\\\!:*:*:*:*:enterprise:macos:*:*\",\"versionEndExcluding\":\"2023.5\",\"matchCriteriaId\":\"34D7936A-123E-4582-9F90-2724A814CB0A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:primx:zed\\\\!:*:*:*:*:free:linux:*:*\",\"versionEndExcluding\":\"2023.5\",\"matchCriteriaId\":\"B67C1CB4-F980-4856-82B2-95BECC07F380\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:primx:zed\\\\!:*:*:*:*:free:macos:*:*\",\"versionEndExcluding\":\"2023.5\",\"matchCriteriaId\":\"A895BAFB-8677-4ABB-9188-C84CAA9DC74B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:primx:zed\\\\!:*:*:*:*:free:windows:*:*\",\"versionEndExcluding\":\"2023.5\",\"matchCriteriaId\":\"006184BD-4D3B-4DB1-AE7C-E3B10E683BFB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:primx:zed\\\\!:*:*:*:*:pro:linux:*:*\",\"versionEndExcluding\":\"2023.5\",\"matchCriteriaId\":\"74F37A78-4F7C-4334-B9C1-8D8BA1570527\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:primx:zed\\\\!:*:*:*:*:pro:macos:*:*\",\"versionEndExcluding\":\"2023.5\",\"matchCriteriaId\":\"D1C7B28D-6E45-4B99-B764-2D622DDBE53A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:primx:zed\\\\!:*:*:*:*:pro:windows:*:*\",\"versionEndExcluding\":\"2023.5\",\"matchCriteriaId\":\"ACFFF19C-080B-485E-8E83-927125E5676E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:primx:zed\\\\!:*:*:*:*:enterprise:windows:*:*\",\"versionEndExcluding\":\"q.2020.3\",\"matchCriteriaId\":\"7C67598A-6CE7-4802-BB1F-65D40CF38DAC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:primx:zed\\\\!:*:*:*:*:enterprise:windows:*:*\",\"versionStartIncluding\":\"2023.0\",\"versionEndExcluding\":\"2023.5\",\"matchCriteriaId\":\"1B21D96F-47D7-4DE6-80AD-68986FF75C77\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:primx:zed\\\\!:*:*:*:*:enterprise:windows:*:*\",\"versionStartIncluding\":\"q.2021.0\",\"versionEndExcluding\":\"q.2021.2\",\"matchCriteriaId\":\"747C7A04-7E6E-4A2C-BCFC-01EC16ABE951\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:primx:zedmail:*:*:*:*:*:windows:*:*\",\"versionEndExcluding\":\"2023.5\",\"matchCriteriaId\":\"01B1BDF0-697E-4EA2-8E26-5B786E03FCF1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:primx:zonecentral:*:*:*:*:*:windows:*:*\",\"versionEndExcluding\":\"q.2021.2\",\"matchCriteriaId\":\"60E1C4D1-FD43-44D1-90E3-0A3936D947A2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:primx:zonecentral:*:*:*:*:*:windows:*:*\",\"versionStartIncluding\":\"2023.0\",\"versionEndExcluding\":\"2023.5\",\"matchCriteriaId\":\"5FA52575-445D-48F8-B1D9-F3981DDBD5D3\"}]}]}],\"references\":[{\"url\":\"https://www.primx.eu/en/bulletins/security-bulletin-23B30931/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.primx.eu/fr/blog/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Product\"]},{\"url\":\"https://www.primx.eu/en/bulletins/security-bulletin-23B30931/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.primx.eu/fr/blog/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Product\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.primx.eu/fr/blog/\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://www.primx.eu/en/bulletins/security-bulletin-23B30931/\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T22:16:46.889Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 5.5, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-50440\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-05-22T18:27:33.353117Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-284\", \"description\": \"CWE-284 Improper Access Control\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-06-03T13:41:10.378Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"references\": [{\"url\": \"https://www.primx.eu/fr/blog/\"}, {\"url\": \"https://www.primx.eu/en/bulletins/security-bulletin-23B30931/\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"ZED containers produced by PRIMX ZED! for Windows before Q.2020.3 (ANSSI qualification submission); ZED! for Windows before Q.2021.2 (ANSSI qualification submission); ZONECENTRAL for Windows before Q.2021.2 (ANSSI qualification submission); ZONECENTRAL for Windows before 2023.5; ZEDMAIL for Windows before 2023.5; ZED! for Windows, Mac, Linux before 2023.5; ZEDFREE for Windows, Mac, Linux before 2023.5; or ZEDPRO for Windows, Mac, Linux before 2023.5 can be modified by an unauthenticated attacker to include a UNC reference so that it could trigger network access to an attacker-controlled computer when opened by the victim.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"n/a\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2023-12-13T20:28:25.568Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-50440\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-06-03T13:43:44.490Z\", \"dateReserved\": \"2023-12-10T00:00:00.000Z\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2023-12-13T00:00:00.000Z\", \"assignerShortName\": \"mitre\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…