A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions < V1.17.0), Mendix SAML (Mendix 7 compatible) (All versions >= V1.17.0 < V1.17.2), Mendix SAML (Mendix 8 compatible) (All versions < V2.3.0), Mendix SAML (Mendix 8 compatible) (All versions >= V2.3.0 < V2.3.2), Mendix SAML (Mendix 9 compatible, New Track) (All versions < V3.3.1), Mendix SAML (Mendix 9 compatible, New Track) (All versions >= V3.3.1 < V3.3.5), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions < V3.3.0), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions >= V3.3.0 < V3.3.4). Affected versions of the module insufficiently protect from packet capture replay, only when the not recommended, non default configuration option `'Allow Idp Initiated Authentication'` is enabled. This CVE entry describes the incomplete fix for CVE-2022-37011 in a specific non default configuration.
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Mendix SAML (Mendix 7 compatible) |
Version: All versions < V1.17.0 |
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:54:03.401Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-638652.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-44457",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-01T18:07:08.237002Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-01T18:07:21.381Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Mendix SAML (Mendix 7 compatible)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.17.0"
}
]
},
{
"product": "Mendix SAML (Mendix 7 compatible)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V1.17.0 \u003c V1.17.2"
}
]
},
{
"product": "Mendix SAML (Mendix 8 compatible)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3.0"
}
]
},
{
"product": "Mendix SAML (Mendix 8 compatible)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.3.0 \u003c V2.3.2"
}
]
},
{
"product": "Mendix SAML (Mendix 9 compatible, New Track)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.1"
}
]
},
{
"product": "Mendix SAML (Mendix 9 compatible, New Track)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V3.3.1 \u003c V3.3.5"
}
]
},
{
"product": "Mendix SAML (Mendix 9 compatible, Upgrade Track)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.0"
}
]
},
{
"product": "Mendix SAML (Mendix 9 compatible, Upgrade Track)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V3.3.0 \u003c V3.3.4"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions \u003c V1.17.0), Mendix SAML (Mendix 7 compatible) (All versions \u003e= V1.17.0 \u003c V1.17.2), Mendix SAML (Mendix 8 compatible) (All versions \u003c V2.3.0), Mendix SAML (Mendix 8 compatible) (All versions \u003e= V2.3.0 \u003c V2.3.2), Mendix SAML (Mendix 9 compatible, New Track) (All versions \u003c V3.3.1), Mendix SAML (Mendix 9 compatible, New Track) (All versions \u003e= V3.3.1 \u003c V3.3.5), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions \u003c V3.3.0), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions \u003e= V3.3.0 \u003c V3.3.4). Affected versions of the module insufficiently protect from packet capture replay, only when the not recommended, non default configuration option `\u0027Allow Idp Initiated Authentication\u0027` is enabled. This CVE entry describes the incomplete fix for CVE-2022-37011 in a specific non default configuration."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-294",
"description": "CWE-294: Authentication Bypass by Capture-replay",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-13T00:00:00.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-638652.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-44457",
"datePublished": "2022-11-08T00:00:00.000Z",
"dateReserved": "2022-10-31T00:00:00.000Z",
"dateUpdated": "2025-05-01T18:07:21.381Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2022-44457\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-11-08T11:15:12.257\",\"lastModified\":\"2025-05-01T18:15:50.063\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions \u003c V1.17.0), Mendix SAML (Mendix 7 compatible) (All versions \u003e= V1.17.0 \u003c V1.17.2), Mendix SAML (Mendix 8 compatible) (All versions \u003c V2.3.0), Mendix SAML (Mendix 8 compatible) (All versions \u003e= V2.3.0 \u003c V2.3.2), Mendix SAML (Mendix 9 compatible, New Track) (All versions \u003c V3.3.1), Mendix SAML (Mendix 9 compatible, New Track) (All versions \u003e= V3.3.1 \u003c V3.3.5), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions \u003c V3.3.0), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions \u003e= V3.3.0 \u003c V3.3.4). Affected versions of the module insufficiently protect from packet capture replay, only when the not recommended, non default configuration option `\u0027Allow Idp Initiated Authentication\u0027` is enabled. This CVE entry describes the incomplete fix for CVE-2022-37011 in a specific non default configuration.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Mendix SAML (compatible con Mendix 7) (Todas las versiones \u0026lt; V1.17.0),\\nMendix SAML (compatible con Mendix 7) (Todas las versiones \u0026gt;= V1.17.0 \u0026lt; V1.17.2), \\nMendix SAML (Mendix 8 compatible) (Todas las versiones \u0026lt; V2.3.0), \\nMendix SAML (compatible con Mendix 8) (Todas las versiones \u0026gt; V2.3.0 \u0026lt; V2.3.2), \\nMendix SAML (compatible con Mendix 9, New Track) (Todas las versiones \u0026lt; V3.3.1), \\nMendix SAML (compatible con Mendix 9, New Track) (todas las versiones \u0026gt;= V3.3.1 \u0026lt; V3.3.5), \\nMendix SAML (compatible con Mendix 9, Upgrade Track) (todas las versiones \u0026lt; V3.3.0 ), \\nMendix SAML (compatible con Mendix 9, Upgrade Track) (Todas las versiones \u0026gt; V3.3.0 y \u0026lt; V3.3.4). \\nLas versiones afectadas del m\u00f3dulo no protegen suficientemente contra la reproducci\u00f3n de captura de paquetes, solo cuando la opci\u00f3n de configuraci\u00f3n no predeterminada y no recomendada \\\"\\\"Permitir Autenticaci\u00f3n Iniciada por Idp\\\"\\\" est\u00e1 habilitada. Esta entrada de CVE describe la soluci\u00f3n incompleta para CVE-2022-37011 en una configuraci\u00f3n espec\u00edfica no predeterminada.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-294\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-294\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mendix:saml:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.17.0\",\"matchCriteriaId\":\"FAE0D810-0D2A-4158-B1A1-045743098BA9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mendix:saml:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2.3.0\",\"versionEndExcluding\":\"2.3.2\",\"matchCriteriaId\":\"6C2A31D3-792D-46F1-90C3-818EEE5D1C1B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mendix:saml:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"3.3.0\",\"versionEndExcluding\":\"3.3.4\",\"matchCriteriaId\":\"083B7407-2BCC-41DC-BF2D-2AC3298A7FAA\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-638652.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-638652.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-638652.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T13:54:03.401Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-44457\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-05-01T18:07:08.237002Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-05-01T18:07:17.510Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"Siemens\", \"product\": \"Mendix SAML (Mendix 7 compatible)\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V1.17.0\"}]}, {\"vendor\": \"Siemens\", \"product\": \"Mendix SAML (Mendix 7 compatible)\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003e= V1.17.0 \u003c V1.17.2\"}]}, {\"vendor\": \"Siemens\", \"product\": \"Mendix SAML (Mendix 8 compatible)\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V2.3.0\"}]}, {\"vendor\": \"Siemens\", \"product\": \"Mendix SAML (Mendix 8 compatible)\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003e= V2.3.0 \u003c V2.3.2\"}]}, {\"vendor\": \"Siemens\", \"product\": \"Mendix SAML (Mendix 9 compatible, New Track)\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V3.3.1\"}]}, {\"vendor\": \"Siemens\", \"product\": \"Mendix SAML (Mendix 9 compatible, New Track)\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003e= V3.3.1 \u003c V3.3.5\"}]}, {\"vendor\": \"Siemens\", \"product\": \"Mendix SAML (Mendix 9 compatible, Upgrade Track)\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V3.3.0\"}]}, {\"vendor\": \"Siemens\", \"product\": \"Mendix SAML (Mendix 9 compatible, Upgrade Track)\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003e= V3.3.0 \u003c V3.3.4\"}]}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-638652.pdf\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions \u003c V1.17.0), Mendix SAML (Mendix 7 compatible) (All versions \u003e= V1.17.0 \u003c V1.17.2), Mendix SAML (Mendix 8 compatible) (All versions \u003c V2.3.0), Mendix SAML (Mendix 8 compatible) (All versions \u003e= V2.3.0 \u003c V2.3.2), Mendix SAML (Mendix 9 compatible, New Track) (All versions \u003c V3.3.1), Mendix SAML (Mendix 9 compatible, New Track) (All versions \u003e= V3.3.1 \u003c V3.3.5), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions \u003c V3.3.0), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions \u003e= V3.3.0 \u003c V3.3.4). Affected versions of the module insufficiently protect from packet capture replay, only when the not recommended, non default configuration option `\u0027Allow Idp Initiated Authentication\u0027` is enabled. This CVE entry describes the incomplete fix for CVE-2022-37011 in a specific non default configuration.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-294\", \"description\": \"CWE-294: Authentication Bypass by Capture-replay\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2022-12-13T00:00:00.000Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2022-44457\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-05-01T18:07:21.381Z\", \"dateReserved\": \"2022-10-31T00:00:00.000Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2022-11-08T00:00:00.000Z\", \"assignerShortName\": \"siemens\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…