CVE-2022-37056 (GCVE-0-2022-37056)
Vulnerability from cvelistv5
Published
2022-08-28 16:03
Modified
2025-01-09 17:38
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main,
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing | Exploit, Patch, Third Party Advisory | |
cve@mitre.org | https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308 | ||
cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing | Exploit, Patch, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T10:21:32.734Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2022-37056", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-09T15:56:42.079801Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-09T17:38:08.414Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main," } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-06T14:32:07.758Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.dlink.com/en/security-bulletin/" }, { "url": "https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing" }, { "url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308" } ], "x_generator": { "engine": "enrichogram 0.0.1" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2022-37056", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main," } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.dlink.com/en/security-bulletin/", "refsource": "MISC", "url": "https://www.dlink.com/en/security-bulletin/" }, { "name": "https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing", "refsource": "MISC", "url": "https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-37056", "datePublished": "2022-08-28T16:03:48", "dateReserved": "2022-08-01T00:00:00", "dateUpdated": "2025-01-09T17:38:08.414Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-37056\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2022-08-28T17:15:08.413\",\"lastModified\":\"2025-01-09T18:15:24.797\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main,\"},{\"lang\":\"es\",\"value\":\"D-Link GO-RT-AC750 versiones GORTAC750_revA_v101b03 y GO-RT-AC750_revB_FWv200b02, son vulnerables a una inyecci\u00f3n de comandos por medio de /cgibin, hnap_main,\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dlink:go-rt-ac750_firmware:reva_1.01b03:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1B975BD2-5567-4B7A-BC8D-633B5D446556\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dlink:go-rt-ac750_firmware:revb_2.00b02:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"26C39776-31C6-498B-91C4-2CAB0EEFFEBF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dlink:go-rt-ac750:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EE067003-B0B5-4419-8BB3-A31C015276D0\"}]}]}],\"references\":[{\"url\":\"https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://www.dlink.com/en/security-bulletin/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://www.dlink.com/en/security-bulletin/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.dlink.com/en/security-bulletin/\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}, {\"url\": \"https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T10:21:32.734Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-37056\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-09T15:56:42.079801Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-01-09T17:37:28.335Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"references\": [{\"url\": \"https://www.dlink.com/en/security-bulletin/\"}, {\"url\": \"https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing\"}, {\"url\": \"https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308\"}], \"x_generator\": {\"engine\": \"enrichogram 0.0.1\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main,\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2025-01-06T14:32:07.758Z\"}, \"x_legacyV4Record\": {\"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"n/a\"}]}, \"product_name\": \"n/a\"}]}, \"vendor_name\": \"n/a\"}]}}, \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://www.dlink.com/en/security-bulletin/\", \"name\": \"https://www.dlink.com/en/security-bulletin/\", \"refsource\": \"MISC\"}, {\"url\": \"https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing\", \"name\": \"https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing\", \"refsource\": \"MISC\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main,\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"n/a\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2022-37056\", \"STATE\": \"PUBLIC\", \"ASSIGNER\": \"cve@mitre.org\"}}}}", "cveMetadata": "{\"cveId\": \"CVE-2022-37056\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-01-09T17:38:08.414Z\", \"dateReserved\": \"2022-08-01T00:00:00\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2022-08-28T16:03:48\", \"assignerShortName\": \"mitre\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…