CVE-2022-37056 (GCVE-0-2022-37056)
Vulnerability from cvelistv5
Published
2022-08-28 16:03
Modified
2025-01-09 17:38
Severity ?
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main,
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:21:32.734Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dlink.com/en/security-bulletin/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-37056",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-09T15:56:42.079801Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-09T17:38:08.414Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main,"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-06T14:32:07.758Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.dlink.com/en/security-bulletin/"
        },
        {
          "url": "https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing"
        },
        {
          "url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308"
        }
      ],
      "x_generator": {
        "engine": "enrichogram 0.0.1"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-37056",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main,"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dlink.com/en/security-bulletin/",
              "refsource": "MISC",
              "url": "https://www.dlink.com/en/security-bulletin/"
            },
            {
              "name": "https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing",
              "refsource": "MISC",
              "url": "https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-37056",
    "datePublished": "2022-08-28T16:03:48",
    "dateReserved": "2022-08-01T00:00:00",
    "dateUpdated": "2025-01-09T17:38:08.414Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-37056\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2022-08-28T17:15:08.413\",\"lastModified\":\"2025-01-09T18:15:24.797\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main,\"},{\"lang\":\"es\",\"value\":\"D-Link GO-RT-AC750 versiones GORTAC750_revA_v101b03 y GO-RT-AC750_revB_FWv200b02, son vulnerables a una inyecci\u00f3n de comandos por medio de /cgibin, hnap_main,\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dlink:go-rt-ac750_firmware:reva_1.01b03:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1B975BD2-5567-4B7A-BC8D-633B5D446556\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dlink:go-rt-ac750_firmware:revb_2.00b02:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"26C39776-31C6-498B-91C4-2CAB0EEFFEBF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dlink:go-rt-ac750:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EE067003-B0B5-4419-8BB3-A31C015276D0\"}]}]}],\"references\":[{\"url\":\"https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://www.dlink.com/en/security-bulletin/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://www.dlink.com/en/security-bulletin/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.dlink.com/en/security-bulletin/\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}, {\"url\": \"https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T10:21:32.734Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-37056\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-09T15:56:42.079801Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-01-09T17:37:28.335Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"references\": [{\"url\": \"https://www.dlink.com/en/security-bulletin/\"}, {\"url\": \"https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing\"}, {\"url\": \"https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308\"}], \"x_generator\": {\"engine\": \"enrichogram 0.0.1\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main,\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2025-01-06T14:32:07.758Z\"}, \"x_legacyV4Record\": {\"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"n/a\"}]}, \"product_name\": \"n/a\"}]}, \"vendor_name\": \"n/a\"}]}}, \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://www.dlink.com/en/security-bulletin/\", \"name\": \"https://www.dlink.com/en/security-bulletin/\", \"refsource\": \"MISC\"}, {\"url\": \"https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing\", \"name\": \"https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing\", \"refsource\": \"MISC\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main,\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"n/a\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2022-37056\", \"STATE\": \"PUBLIC\", \"ASSIGNER\": \"cve@mitre.org\"}}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2022-37056\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-01-09T17:38:08.414Z\", \"dateReserved\": \"2022-08-01T00:00:00\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2022-08-28T16:03:48\", \"assignerShortName\": \"mitre\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…