CVE-2021-33718
Vulnerability from cvelistv5
Published
2021-07-13 11:03
Modified
2024-08-03 23:58
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.22), Mendix Applications using Mendix 8 (All versions < V8.18.7), Mendix Applications using Mendix 9 (All versions < V9.3.0). Write access checks of attributes of an object could be bypassed, if user has a write permissions to the first attribute of this object.
References
Impacted products
Vendor | Product | Version | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Mendix Applications using Mendix 7 |
Version: All versions < V7.23.22 |
||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:58:22.807Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-352521.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Mendix Applications using Mendix 7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.23.22" } ] }, { "product": "Mendix Applications using Mendix 8", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.18.7" } ] }, { "product": "Mendix Applications using Mendix 9", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.3.0" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.22), Mendix Applications using Mendix 8 (All versions \u003c V8.18.7), Mendix Applications using Mendix 9 (All versions \u003c V9.3.0). Write access checks of attributes of an object could be bypassed, if user has a write permissions to the first attribute of this object." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-863", "description": "CWE-863: Incorrect Authorization", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-07-13T11:03:06", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-352521.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-33718", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Mendix Applications using Mendix 7", "version": { "version_data": [ { "version_value": "All versions \u003c V7.23.22" } ] } }, { "product_name": "Mendix Applications using Mendix 8", "version": { "version_data": [ { "version_value": "All versions \u003c V8.18.7" } ] } }, { "product_name": "Mendix Applications using Mendix 9", "version": { "version_data": [ { "version_value": "All versions \u003c V9.3.0" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.22), Mendix Applications using Mendix 8 (All versions \u003c V8.18.7), Mendix Applications using Mendix 9 (All versions \u003c V9.3.0). Write access checks of attributes of an object could be bypassed, if user has a write permissions to the first attribute of this object." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-863: Incorrect Authorization" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-352521.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-352521.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-33718", "datePublished": "2021-07-13T11:03:06", "dateReserved": "2021-05-28T00:00:00", "dateUpdated": "2024-08-03T23:58:22.807Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-33718\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-07-13T11:15:10.183\",\"lastModified\":\"2024-11-21T06:09:26.460\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.22), Mendix Applications using Mendix 8 (All versions \u003c V8.18.7), Mendix Applications using Mendix 9 (All versions \u003c V9.3.0). Write access checks of attributes of an object could be bypassed, if user has a write permissions to the first attribute of this object.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en las aplicaciones de Mendix que usan Mendix 7 (todas las versiones anteriores a V7.23.22), las aplicaciones de Mendix que usan Mendix 8 (todas las versiones anteriores a V8.18.7) y las aplicaciones de Mendix que usan Mendix 9 (todas las versiones anteriores a V9.3.0). Las comprobaciones de acceso a la escritura de los atributos de un objeto podr\u00edan ser omitidas, si el usuario presenta permisos de escritura en el primer atributo de este objeto\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.6,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:S/C:N/I:P/A:N\",\"baseScore\":3.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":6.8,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-863\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:mendix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\",\"versionEndExcluding\":\"7.23.22\",\"matchCriteriaId\":\"407BBB53-69B6-4B42-A4D7-3AB55523CDD0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:mendix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.0\",\"versionEndExcluding\":\"8.18.7\",\"matchCriteriaId\":\"2F163BC4-5367-4F46-B20B-60082E95F315\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:mendix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.0\",\"versionEndExcluding\":\"9.3.0\",\"matchCriteriaId\":\"E3BCE4B4-2CDA-464A-A750-4D8219B172D9\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-352521.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-352521.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.