CVE-2021-27663 (GCVE-0-2021-27663)
Vulnerability from cvelistv5 – Published: 2021-08-30 16:37 – Updated: 2024-09-17 03:38
VLAI?
Title
CEM Systems AC2000
Summary
A vulnerability in versions 10.1 through 10.5 of Johnson Controls CEM Systems AC2000 allows a remote attacker to access to the system without adequate authorization. This issue affects: Johnson Controls CEM Systems AC2000 10.1; 10.2; 10.3; 10.4; 10.5.
Severity ?
8.2 (High)
CWE
- CWE-285 - Improper Authorization
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Johnson Controls | CEM Systems AC2000 |
Affected:
10.1 , ≤ 10.5
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T21:26:10.645Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
},
{
"name": "ICS-CERT Advisory",
"tags": [
"third-party-advisory",
"x_refsource_CERT",
"x_transferred"
],
"url": "https://us-cert.gov/ics/advisories/ICSA-21-238-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "CEM Systems AC2000",
"vendor": "Johnson Controls",
"versions": [
{
"lessThanOrEqual": "10.5",
"status": "affected",
"version": "10.1",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-08-30T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in versions 10.1 through 10.5 of Johnson Controls CEM Systems AC2000 allows a remote attacker to access to the system without adequate authorization. This issue affects: Johnson Controls CEM Systems AC2000 10.1; 10.2; 10.3; 10.4; 10.5."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-285",
"description": "CWE-285: Improper Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-08-30T16:37:41",
"orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
"shortName": "jci"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
},
{
"name": "ICS-CERT Advisory",
"tags": [
"third-party-advisory",
"x_refsource_CERT"
],
"url": "https://us-cert.gov/ics/advisories/ICSA-21-238-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Apply a patch to all affected versions and implementations.\nThe fix will also be included in 10.5 Server Feature Pack 2, version 10.6 and all future releases.\nTo access the patch, affected users should contact their CEM support team:\nhttps://www.cemsys.com/support/technical-helpdesk/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "CEM Systems AC2000",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productsecurity@jci.com",
"DATE_PUBLIC": "2021-08-30T14:08:00.000Z",
"ID": "CVE-2021-27663",
"STATE": "PUBLIC",
"TITLE": "CEM Systems AC2000"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "CEM Systems AC2000",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "10.1",
"version_value": "10.5"
}
]
}
}
]
},
"vendor_name": "Johnson Controls"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in versions 10.1 through 10.5 of Johnson Controls CEM Systems AC2000 allows a remote attacker to access to the system without adequate authorization. This issue affects: Johnson Controls CEM Systems AC2000 10.1; 10.2; 10.3; 10.4; 10.5."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-285: Improper Authorization"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories",
"refsource": "CONFIRM",
"url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
},
{
"name": "ICS-CERT Advisory",
"refsource": "CERT",
"url": "https://us-cert.gov/ics/advisories/ICSA-21-238-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Apply a patch to all affected versions and implementations.\nThe fix will also be included in 10.5 Server Feature Pack 2, version 10.6 and all future releases.\nTo access the patch, affected users should contact their CEM support team:\nhttps://www.cemsys.com/support/technical-helpdesk/"
}
],
"source": {
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
"assignerShortName": "jci",
"cveId": "CVE-2021-27663",
"datePublished": "2021-08-30T16:37:41.273754Z",
"dateReserved": "2021-02-24T00:00:00",
"dateUpdated": "2024-09-17T03:38:42.161Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:johnsoncontrols:ac2000_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"10.1\", \"versionEndIncluding\": \"10.5\", \"matchCriteriaId\": \"B7990FFE-22BA-482F-92A0-9E3DA64467A6\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:johnsoncontrols:ac2000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9B69C423-26B0-480F-BDA7-6836945BD47B\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability in versions 10.1 through 10.5 of Johnson Controls CEM Systems AC2000 allows a remote attacker to access to the system without adequate authorization. This issue affects: Johnson Controls CEM Systems AC2000 10.1; 10.2; 10.3; 10.4; 10.5.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad en versiones 10.1 hasta 10.5 de Johnson Controls CEM Systems AC2000, permite a un atacante remoto acceder al sistema sin la autorizaci\\u00f3n adecuada. Este problema afecta a: Johnson Controls CEM Systems AC2000 versiones 10.1; 10.2; 10.3; 10.4; 10.5.\"}]",
"id": "CVE-2021-27663",
"lastModified": "2024-11-21T05:58:24.147",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"productsecurity@jci.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N\", \"baseScore\": 8.2, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 4.2}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:C/I:C/A:C\", \"baseScore\": 9.3, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 8.6, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2021-08-30T18:15:08.663",
"references": "[{\"url\": \"https://us-cert.gov/ics/advisories/ICSA-21-238-01\", \"source\": \"productsecurity@jci.com\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.johnsoncontrols.com/cyber-solutions/security-advisories\", \"source\": \"productsecurity@jci.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://us-cert.gov/ics/advisories/ICSA-21-238-01\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.johnsoncontrols.com/cyber-solutions/security-advisories\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "productsecurity@jci.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"productsecurity@jci.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-285\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-Other\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2021-27663\",\"sourceIdentifier\":\"productsecurity@jci.com\",\"published\":\"2021-08-30T18:15:08.663\",\"lastModified\":\"2024-11-21T05:58:24.147\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in versions 10.1 through 10.5 of Johnson Controls CEM Systems AC2000 allows a remote attacker to access to the system without adequate authorization. This issue affects: Johnson Controls CEM Systems AC2000 10.1; 10.2; 10.3; 10.4; 10.5.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en versiones 10.1 hasta 10.5 de Johnson Controls CEM Systems AC2000, permite a un atacante remoto acceder al sistema sin la autorizaci\u00f3n adecuada. Este problema afecta a: Johnson Controls CEM Systems AC2000 versiones 10.1; 10.2; 10.3; 10.4; 10.5.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productsecurity@jci.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N\",\"baseScore\":8.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":4.2},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:C/I:C/A:C\",\"baseScore\":9.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.6,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productsecurity@jci.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-285\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:johnsoncontrols:ac2000_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"10.1\",\"versionEndIncluding\":\"10.5\",\"matchCriteriaId\":\"B7990FFE-22BA-482F-92A0-9E3DA64467A6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:johnsoncontrols:ac2000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9B69C423-26B0-480F-BDA7-6836945BD47B\"}]}]}],\"references\":[{\"url\":\"https://us-cert.gov/ics/advisories/ICSA-21-238-01\",\"source\":\"productsecurity@jci.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.johnsoncontrols.com/cyber-solutions/security-advisories\",\"source\":\"productsecurity@jci.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://us-cert.gov/ics/advisories/ICSA-21-238-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.johnsoncontrols.com/cyber-solutions/security-advisories\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…