Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2020-8745 (GCVE-0-2020-8745)
Vulnerability from cvelistv5
- escalation of privilege
 
| URL | Tags | ||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
                    
  | 
                |||||||||||||||||||||||||||||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Intel(R) CSME, Intel(R) TXE | 
                    
                      
                        
                          Version: Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 | 
                  
{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T10:12:09.559Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20201113-0005/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20201113-0002/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Intel(R) CSME, Intel(R) TXE",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 may allow an unauthenticated user to potentially enable escalation of privilege via physical access."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "escalation of privilege",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-11T12:06:31",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20201113-0005/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20201113-0002/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@intel.com",
          "ID": "CVE-2020-8745",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Intel(R) CSME, Intel(R) TXE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 may allow an unauthenticated user to potentially enable escalation of privilege via physical access."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "escalation of privilege"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391",
              "refsource": "MISC",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391"
            },
            {
              "name": "https://security.netapp.com/advisory/ntap-20201113-0005/",
              "refsource": "CONFIRM",
              "url": "https://security.netapp.com/advisory/ntap-20201113-0005/"
            },
            {
              "name": "https://security.netapp.com/advisory/ntap-20201113-0002/",
              "refsource": "CONFIRM",
              "url": "https://security.netapp.com/advisory/ntap-20201113-0002/"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2020-8745",
    "datePublished": "2020-11-12T18:06:09",
    "dateReserved": "2020-02-06T00:00:00",
    "dateUpdated": "2024-08-04T10:12:09.559Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2020-8745\",\"sourceIdentifier\":\"secure@intel.com\",\"published\":\"2020-11-12T18:15:17.300\",\"lastModified\":\"2025-03-28T15:19:45.743\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 may allow an unauthenticated user to potentially enable escalation of privilege via physical access.\"},{\"lang\":\"es\",\"value\":\"Una administraci\u00f3n de flujo de control insuficiente en el subsistema para Intel\u00ae CSME versiones anteriores a 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 y 14.5.25, Intel\u00ae TXE versiones anteriores a 3.1.80 y 4.0.30, pueden habilitar a un usuario no autenticado para permitir potencialmente una escalada de privilegios por medio de un acceso f\u00edsico\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":4.6,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"11.8.80\",\"matchCriteriaId\":\"BA64E7EE-8977-4427-9FF9-DD9FE80F02C6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"11.12.0\",\"versionEndExcluding\":\"11.12.80\",\"matchCriteriaId\":\"3DDDD0D3-CE11-49C7-93F7-F2AA1053DD86\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"11.22.0\",\"versionEndExcluding\":\"11.22.80\",\"matchCriteriaId\":\"7A5C4B3E-3C68-4D2B-A181-18A71378362E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.0\",\"versionEndExcluding\":\"12.0.70\",\"matchCriteriaId\":\"EB22E6F2-D34F-4A05-9CC2-BCAF3E84F54E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"14.0\",\"versionEndExcluding\":\"14.0.45\",\"matchCriteriaId\":\"94D40FF5-8E0A-4591-9CE4-2E671C8E4F2E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"14.5.0\",\"versionEndExcluding\":\"14.5.25\",\"matchCriteriaId\":\"2B323721-380E-4222-AB7A-9993BF8DA653\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:trusted_execution_technology:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.1.80\",\"matchCriteriaId\":\"DF1D6613-FA0F-4859-B45C-A0F86BCF1CF8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:trusted_execution_technology:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"4.0\",\"versionEndExcluding\":\"4.0.30\",\"matchCriteriaId\":\"D4BA87F2-F5DE-44A1-B81A-CE1DB5EAFEFA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_drive_controller_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"05.00.01.00\",\"matchCriteriaId\":\"AA19F1AE-18D4-43F6-BBAB-225B241042BC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_drive_controller:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0137C77B-D587-47D6-AEBE-462D00546FD7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_et200sp_1515sp_pc2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"0209.0105\",\"matchCriteriaId\":\"7FC1D3E4-0B86-4464-96BE-D938B379FDAE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_et200sp_1515sp_pc2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4CA8F936-9C3B-46C0-9623-0AF16A4B0294\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"22.01.08\",\"matchCriteriaId\":\"F5320759-AAAB-4FEA-99AB-51A7F7EE9F58\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"506DEE00-30D2-4E29-9645-757EB8778C0F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"ECC5341D-9982-4F18-9C8D-2912DDB8EF9A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8F3C3E60-7C36-4F5D-B454-97C9D0FD9459\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc127e_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"27.01.05\",\"matchCriteriaId\":\"161DFB8B-6B7B-4F6D-9452-EF43A70BBE50\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F63C0B17-60E2-4240-92FD-4B7C7D8F2C8B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"27.01.05\",\"matchCriteriaId\":\"CA71050F-CCED-4885-A483-79CC43F6AEC9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A40D0CDB-7BE6-491F-B730-3B4E10CA159A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"21.01.15\",\"matchCriteriaId\":\"5AECF7C4-3FF7-4663-A49C-9DB91BA5C28E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FDF9D4C3-1892-48FA-95B4-835B636A4005\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc477e_pro:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3FC5CE20-7D08-4496-A857-C3A4BD0AB1AC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc527g_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.4.0\",\"matchCriteriaId\":\"65A6E7CD-4AEA-465D-89B3-6EF66E4F17B6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc527g:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"55156889-E9DA-4F04-B894-339DC39CA942\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc547g_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"r1.30.0\",\"matchCriteriaId\":\"FEA68927-4910-4DF3-A16B-7187099CC063\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc547g:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9EB339B5-602F-4AB5-9998-465FDC6ABD6C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc627e_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"25.02.08\",\"matchCriteriaId\":\"6779ADD8-298D-4FF4-8AD3-82E995B2E144\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9D9AF082-8345-4BE1-B1FC-6E0316BB833B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc647e_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"25.02.08\",\"matchCriteriaId\":\"5D3BECCA-5783-4B3C-B659-21160B4D2726\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E430C4C5-D887-47C6-B50F-66EEE9519151\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc667e_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"25.02.08\",\"matchCriteriaId\":\"6822E36B-D635-498B-9A64-BE427DC798EA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc667e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4E6BC195-47BB-48A7-8D73-F800B4C11599\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_ipc847e_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"25.02.08\",\"matchCriteriaId\":\"9C5CB316-59B9-4DDB-A8B8-14D8BCD991CE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1157418C-14C4-43C4-B63E-7E98D868A94F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"23.01.08\",\"matchCriteriaId\":\"4ABF49D4-34CE-4DEA-AA2E-A40A53472D1F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"187C6D51-5B86-484D-AE0F-26D1C9465580\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinumerik_828d_hw_pu.4_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"08.00.00.00\",\"matchCriteriaId\":\"AC13F580-5446-437D-9982-280C80EAE2D3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinumerik_828d_hw_pu.4:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2C594847-596D-4FA2-B56C-745D0A84EBC9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinumerik_mc_mcu_1720_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"05.00.00.00\",\"matchCriteriaId\":\"DF3A945B-078B-45C6-9BA3-3C52650095F1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinumerik_mc_mcu_1720:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DF61B283-76B7-42BB-B88A-EE12EA5AA905\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinumerik_one_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4FADF6B2-FFE7-4C4E-BF93-61CAA9368285\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinumerik_one:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AE30FFDF-5494-400D-8F88-954A6B1503B9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinumerik_840d_sl_ht_10_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CD5F035E-5F72-4E15-BF13-294C3A833BF7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinumerik_840d_sl_ht_10:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"14CED950-F0AB-48D1-9ED8-3357E02AEADE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinumerik_one_ncu_1740_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"04.00.00.00\",\"matchCriteriaId\":\"BE992410-C477-4901-8B18-8AB866BF11A6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinumerik_one_ncu_1740:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F0BCDA32-9100-4D88-A304-CE989A16A06D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinumerik_one_ppu_1740_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"06.00.00.00\",\"matchCriteriaId\":\"B4A4EDCE-6363-43EB-9CE8-11C0BA40E696\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinumerik_one_ppu_1740:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"75815DC0-5782-4BD6-A9DD-F0BE33D2F5FD\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf\",\"source\":\"secure@intel.com\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20201113-0002/\",\"source\":\"secure@intel.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20201113-0005/\",\"source\":\"secure@intel.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391\",\"source\":\"secure@intel.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20201113-0002/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20201113-0005/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}
  fkie_cve-2020-8745
Vulnerability from fkie_nvd
| URL | Tags | ||
|---|---|---|---|
| secure@intel.com | https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf | Patch, Third Party Advisory | |
| secure@intel.com | https://security.netapp.com/advisory/ntap-20201113-0002/ | Third Party Advisory | |
| secure@intel.com | https://security.netapp.com/advisory/ntap-20201113-0005/ | Third Party Advisory | |
| secure@intel.com | https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391 | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf | Patch, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://security.netapp.com/advisory/ntap-20201113-0002/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://security.netapp.com/advisory/ntap-20201113-0005/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391 | Vendor Advisory | 
{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA64E7EE-8977-4427-9FF9-DD9FE80F02C6",
              "versionEndExcluding": "11.8.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3DDDD0D3-CE11-49C7-93F7-F2AA1053DD86",
              "versionEndExcluding": "11.12.80",
              "versionStartIncluding": "11.12.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A5C4B3E-3C68-4D2B-A181-18A71378362E",
              "versionEndExcluding": "11.22.80",
              "versionStartIncluding": "11.22.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB22E6F2-D34F-4A05-9CC2-BCAF3E84F54E",
              "versionEndExcluding": "12.0.70",
              "versionStartIncluding": "12.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "94D40FF5-8E0A-4591-9CE4-2E671C8E4F2E",
              "versionEndExcluding": "14.0.45",
              "versionStartIncluding": "14.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B323721-380E-4222-AB7A-9993BF8DA653",
              "versionEndExcluding": "14.5.25",
              "versionStartIncluding": "14.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:intel:trusted_execution_technology:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF1D6613-FA0F-4859-B45C-A0F86BCF1CF8",
              "versionEndExcluding": "3.1.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:intel:trusted_execution_technology:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D4BA87F2-F5DE-44A1-B81A-CE1DB5EAFEFA",
              "versionEndExcluding": "4.0.30",
              "versionStartIncluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA19F1AE-18D4-43F6-BBAB-225B241042BC",
              "versionEndExcluding": "05.00.01.00",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_drive_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0137C77B-D587-47D6-AEBE-462D00546FD7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et200sp_1515sp_pc2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FC1D3E4-0B86-4464-96BE-D938B379FDAE",
              "versionEndExcluding": "0209.0105",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et200sp_1515sp_pc2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4CA8F936-9C3B-46C0-9623-0AF16A4B0294",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5320759-AAAB-4FEA-99AB-51A7F7EE9F58",
              "versionEndExcluding": "22.01.08",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "506DEE00-30D2-4E29-9645-757EB8778C0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECC5341D-9982-4F18-9C8D-2912DDB8EF9A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F3C3E60-7C36-4F5D-B454-97C9D0FD9459",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc127e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "161DFB8B-6B7B-4F6D-9452-EF43A70BBE50",
              "versionEndExcluding": "27.01.05",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F63C0B17-60E2-4240-92FD-4B7C7D8F2C8B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA71050F-CCED-4885-A483-79CC43F6AEC9",
              "versionEndExcluding": "27.01.05",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A40D0CDB-7BE6-491F-B730-3B4E10CA159A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5AECF7C4-3FF7-4663-A49C-9DB91BA5C28E",
              "versionEndExcluding": "21.01.15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDF9D4C3-1892-48FA-95B4-835B636A4005",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc477e_pro:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FC5CE20-7D08-4496-A857-C3A4BD0AB1AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc527g_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "65A6E7CD-4AEA-465D-89B3-6EF66E4F17B6",
              "versionEndExcluding": "1.4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc527g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55156889-E9DA-4F04-B894-339DC39CA942",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc547g_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEA68927-4910-4DF3-A16B-7187099CC063",
              "versionEndExcluding": "r1.30.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc547g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9EB339B5-602F-4AB5-9998-465FDC6ABD6C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc627e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6779ADD8-298D-4FF4-8AD3-82E995B2E144",
              "versionEndExcluding": "25.02.08",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D9AF082-8345-4BE1-B1FC-6E0316BB833B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc647e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D3BECCA-5783-4B3C-B659-21160B4D2726",
              "versionEndExcluding": "25.02.08",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E430C4C5-D887-47C6-B50F-66EEE9519151",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc667e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6822E36B-D635-498B-9A64-BE427DC798EA",
              "versionEndExcluding": "25.02.08",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc667e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E6BC195-47BB-48A7-8D73-F800B4C11599",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc847e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C5CB316-59B9-4DDB-A8B8-14D8BCD991CE",
              "versionEndExcluding": "25.02.08",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1157418C-14C4-43C4-B63E-7E98D868A94F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4ABF49D4-34CE-4DEA-AA2E-A40A53472D1F",
              "versionEndExcluding": "23.01.08",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "187C6D51-5B86-484D-AE0F-26D1C9465580",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_828d_hw_pu.4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC13F580-5446-437D-9982-280C80EAE2D3",
              "versionEndExcluding": "08.00.00.00",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_828d_hw_pu.4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C594847-596D-4FA2-B56C-745D0A84EBC9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_mc_mcu_1720_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF3A945B-078B-45C6-9BA3-3C52650095F1",
              "versionEndExcluding": "05.00.00.00",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_mc_mcu_1720:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF61B283-76B7-42BB-B88A-EE12EA5AA905",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_one_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4FADF6B2-FFE7-4C4E-BF93-61CAA9368285",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_one:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE30FFDF-5494-400D-8F88-954A6B1503B9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_ht_10_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CD5F035E-5F72-4E15-BF13-294C3A833BF7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_840d_sl_ht_10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "14CED950-F0AB-48D1-9ED8-3357E02AEADE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_one_ncu_1740_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE992410-C477-4901-8B18-8AB866BF11A6",
              "versionEndExcluding": "04.00.00.00",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_one_ncu_1740:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0BCDA32-9100-4D88-A304-CE989A16A06D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_one_ppu_1740_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B4A4EDCE-6363-43EB-9CE8-11C0BA40E696",
              "versionEndExcluding": "06.00.00.00",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_one_ppu_1740:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "75815DC0-5782-4BD6-A9DD-F0BE33D2F5FD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 may allow an unauthenticated user to potentially enable escalation of privilege via physical access."
    },
    {
      "lang": "es",
      "value": "Una administraci\u00f3n de flujo de control insuficiente en el subsistema para Intel\u00ae CSME versiones anteriores a 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 y 14.5.25, Intel\u00ae TXE versiones anteriores a 3.1.80 y 4.0.30, pueden habilitar a un usuario no autenticado para permitir potencialmente una escalada de privilegios por medio de un acceso f\u00edsico"
    }
  ],
  "id": "CVE-2020-8745",
  "lastModified": "2025-03-28T15:19:45.743",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.6,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "PHYSICAL",
          "availabilityImpact": "HIGH",
          "baseScore": 6.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-11-12T18:15:17.300",
  "references": [
    {
      "source": "secure@intel.com",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf"
    },
    {
      "source": "secure@intel.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20201113-0002/"
    },
    {
      "source": "secure@intel.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20201113-0005/"
    },
    {
      "source": "secure@intel.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20201113-0002/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20201113-0005/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391"
    }
  ],
  "sourceIdentifier": "secure@intel.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}
  CERTFR-2021-AVI-357
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer un déni de service à distance, une atteinte à la confidentialité des données et une élévation de privilèges.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | TECNOMATIX Plan Simulation versions antérieures à 16.0.5 | ||
| Siemens | N/A | SIMATIC NET CP 1545-1, CP 343-1 toutes versions | ||
| Siemens | N/A | SIMATIC NET CP 1243-1, CP 1243-7, CP 1243-8 versions 3.1.39 et ultérieures | ||
| Siemens | N/A | SINAMICS SL150, SM150, SM150i toutes versions | ||
| Siemens | N/A | SIMATIC IPC127E, IPC427E, IPC477E, IPC527G, IPC547G toutes versions | ||
| Siemens | N/A | SINUMERIK ONE 840D et PPU 1740 toutes versions | ||
| Siemens | N/A | MENDIX Database Replication versions antérieures à 7.0.1 | ||
| Siemens | N/A | SINAMICS GH150, GL150 (X30), GM150 (X30), SH150, SM120 avec les versions de HMI Panel antérieures à v16 update 4 | ||
| Siemens | N/A | RUGGEDCOM RM1224 versions antérieures à 6.4 | ||
| Siemens | N/A | SIMATIC WinCC runtime advanced versions antérieures à 16 update 4 | ||
| Siemens | N/A | MENDIX module Excel Importer versions antérieures à 9.0.3 | ||
| Siemens | N/A | SCALANCE XM-400, XR-500, M-800, S615 versions antérieures à 6.4 | ||
| Siemens | N/A | SCALANCE W1750D versions v8.3.0.1, v8.6.0 et v8.7.0 | ||
| Siemens | N/A | SIMATIC MV500 toutes versions | ||
| Siemens | N/A | SIMATIC IPC627E, IPC647E, IPC677E, IPC847E versions antérieures à 25.02.08 | ||
| Siemens | N/A | SIMATIC Cloud Connect 7 toutes versions | ||
| Siemens | N/A | SIMATIC HMI versions antérieures à 16 update 4 | ||
| Siemens | N/A | SINEMA Remote Connect Server versions antérieures à 3.0 SP1 | ||
| Siemens | N/A | SIMATIC ET 200SP Open Controller CPU 1515SP PC2 toutes versions | ||
| Siemens | N/A | SIMATIC Field PG M6 toutes versions | ||
| Siemens | N/A | SIMATIC ITP1000 versions antérieures à 23.01.08 | ||
| Siemens | N/A | TIM 1531 toutes versions | ||
| Siemens | N/A | SIMATIC NET CP 1542, CP 1543-1 versions 2.0 et ultérieures | ||
| Siemens | N/A | SINUMERIK 828D HW PPU.4, MC MCU 170 toutes versions | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1518-4 ou 1518F-4 toutes versions | ||
| Siemens | N/A | SIMATIC Field PG M5 versions antérieures à 22.01.08 | 
| Title | Publication Time | Tags | |
|---|---|---|---|
| 
                   | 
              |||
{
  "$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
  "affected_systems": [
    {
      "description": "TECNOMATIX Plan Simulation versions ant\u00e9rieures \u00e0 16.0.5",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "SIMATIC NET CP 1545-1, CP 343-1 toutes versions",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "SIMATIC NET CP 1243-1, CP 1243-7, CP 1243-8 versions 3.1.39 et ult\u00e9rieures",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "SINAMICS SL150, SM150, SM150i toutes versions",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "SIMATIC IPC127E, IPC427E, IPC477E, IPC527G, IPC547G toutes versions",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "SINUMERIK ONE 840D et PPU 1740 toutes versions",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "MENDIX Database Replication versions ant\u00e9rieures \u00e0 7.0.1",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "SINAMICS GH150, GL150 (X30), GM150 (X30), SH150, SM120 avec les versions de HMI Panel ant\u00e9rieures \u00e0 v16 update 4",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "RUGGEDCOM RM1224 versions ant\u00e9rieures \u00e0 6.4",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "SIMATIC WinCC runtime advanced versions ant\u00e9rieures \u00e0 16 update 4",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "MENDIX module Excel Importer versions ant\u00e9rieures \u00e0 9.0.3",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "SCALANCE XM-400, XR-500, M-800, S615 versions ant\u00e9rieures \u00e0 6.4",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "SCALANCE W1750D versions v8.3.0.1, v8.6.0 et v8.7.0",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "SIMATIC MV500 toutes versions",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "SIMATIC IPC627E, IPC647E, IPC677E, IPC847E versions ant\u00e9rieures \u00e0 25.02.08",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "SIMATIC Cloud Connect 7 toutes versions",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "SIMATIC HMI versions ant\u00e9rieures \u00e0 16 update 4",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "SINEMA Remote Connect Server versions ant\u00e9rieures \u00e0 3.0 SP1",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 toutes versions",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "SIMATIC Field PG M6 toutes versions",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "SIMATIC ITP1000 versions ant\u00e9rieures \u00e0 23.01.08",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "TIM 1531 toutes versions",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "SIMATIC NET CP 1542, CP 1543-1 versions 2.0 et ult\u00e9rieures",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "SINUMERIK 828D HW PPU.4, MC MCU 170 toutes versions",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "SIMATIC S7-1500 CPU 1518-4 ou 1518F-4 toutes versions",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    },
    {
      "description": "SIMATIC Field PG M5 versions ant\u00e9rieures \u00e0 22.01.08",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Siemens",
          "scada": true
        }
      }
    }
  ],
  "affected_systems_content": null,
  "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
  "cves": [
    {
      "name": "CVE-2021-25146",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-25146"
    },
    {
      "name": "CVE-2020-24636",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-24636"
    },
    {
      "name": "CVE-2020-15798",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-15798"
    },
    {
      "name": "CVE-2021-25158",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-25158"
    },
    {
      "name": "CVE-2019-8262",
      "url": "https://www.cve.org/CVERecord?id=CVE-2019-8262"
    },
    {
      "name": "CVE-2019-8277",
      "url": "https://www.cve.org/CVERecord?id=CVE-2019-8277"
    },
    {
      "name": "CVE-2021-25157",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-25157"
    },
    {
      "name": "CVE-2021-25144",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-25144"
    },
    {
      "name": "CVE-2021-27385",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-27385"
    },
    {
      "name": "CVE-2021-25661",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-25661"
    },
    {
      "name": "CVE-2019-8265",
      "url": "https://www.cve.org/CVERecord?id=CVE-2019-8265"
    },
    {
      "name": "CVE-2021-25662",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-25662"
    },
    {
      "name": "CVE-2021-25161",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-25161"
    },
    {
      "name": "CVE-2020-8745",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-8745"
    },
    {
      "name": "CVE-2019-8260",
      "url": "https://www.cve.org/CVERecord?id=CVE-2019-8260"
    },
    {
      "name": "CVE-2021-27386",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-27386"
    },
    {
      "name": "CVE-2019-8263",
      "url": "https://www.cve.org/CVERecord?id=CVE-2019-8263"
    },
    {
      "name": "CVE-2021-25660",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-25660"
    },
    {
      "name": "CVE-2020-28393",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-28393"
    },
    {
      "name": "CVE-2021-25150",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-25150"
    },
    {
      "name": "CVE-2019-8261",
      "url": "https://www.cve.org/CVERecord?id=CVE-2019-8261"
    },
    {
      "name": "CVE-2019-8259",
      "url": "https://www.cve.org/CVERecord?id=CVE-2019-8259"
    },
    {
      "name": "CVE-2019-5317",
      "url": "https://www.cve.org/CVERecord?id=CVE-2019-5317"
    },
    {
      "name": "CVE-2021-25145",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-25145"
    },
    {
      "name": "CVE-2021-31341",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-31341"
    },
    {
      "name": "CVE-2021-27396",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-27396"
    },
    {
      "name": "CVE-2020-8698",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-8698"
    },
    {
      "name": "CVE-2020-25705",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-25705"
    },
    {
      "name": "CVE-2021-25148",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-25148"
    },
    {
      "name": "CVE-2019-8280",
      "url": "https://www.cve.org/CVERecord?id=CVE-2019-8280"
    },
    {
      "name": "CVE-2021-27384",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-27384"
    },
    {
      "name": "CVE-2020-0591",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-0591"
    },
    {
      "name": "CVE-2020-0590",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-0590"
    },
    {
      "name": "CVE-2019-8275",
      "url": "https://www.cve.org/CVERecord?id=CVE-2019-8275"
    },
    {
      "name": "CVE-2021-25149",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-25149"
    },
    {
      "name": "CVE-2020-25242",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-25242"
    },
    {
      "name": "CVE-2021-27397",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-27397"
    },
    {
      "name": "CVE-2019-5319",
      "url": "https://www.cve.org/CVERecord?id=CVE-2019-5319"
    },
    {
      "name": "CVE-2021-25156",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-25156"
    },
    {
      "name": "CVE-2019-8264",
      "url": "https://www.cve.org/CVERecord?id=CVE-2019-8264"
    },
    {
      "name": "CVE-2019-19276",
      "url": "https://www.cve.org/CVERecord?id=CVE-2019-19276"
    },
    {
      "name": "CVE-2020-8694",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-8694"
    },
    {
      "name": "CVE-2021-25160",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-25160"
    },
    {
      "name": "CVE-2021-25159",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-25159"
    },
    {
      "name": "CVE-2021-25155",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-25155"
    },
    {
      "name": "CVE-2021-31339",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-31339"
    },
    {
      "name": "CVE-2021-27383",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-27383"
    },
    {
      "name": "CVE-2020-8744",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-8744"
    },
    {
      "name": "CVE-2021-25143",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-25143"
    },
    {
      "name": "CVE-2021-25162",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-25162"
    },
    {
      "name": "CVE-2021-27398",
      "url": "https://www.cve.org/CVERecord?id=CVE-2021-27398"
    },
    {
      "name": "CVE-2020-24635",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-24635"
    }
  ],
  "initial_release_date": "2021-05-11T00:00:00",
  "last_revision_date": "2021-05-11T00:00:00",
  "links": [
    {
      "title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf"
    },
    {
      "title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-854248.pdf"
    },
    {
      "title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324955.pdf"
    },
    {
      "title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-983548.pdf"
    },
    {
      "title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-723417.pdf"
    },
    {
      "title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-919955.pdf"
    },
    {
      "title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
    },
    {
      "title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-501073.pdf"
    },
    {
      "title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf"
    },
    {
      "title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
    },
    {
      "title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
    },
    {
      "title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-116379.pdf"
    },
    {
      "title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-676775.pdf"
    },
    {
      "title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf"
    }
  ],
  "reference": "CERTFR-2021-AVI-357",
  "revisions": [
    {
      "description": "Version initiale",
      "revision_date": "2021-05-11T00:00:00.000000"
    }
  ],
  "risks": [
    {
      "description": "D\u00e9ni de service \u00e0 distance"
    },
    {
      "description": "Injection de code indirecte \u00e0 distance (XSS)"
    },
    {
      "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
    },
    {
      "description": "\u00c9l\u00e9vation de privil\u00e8ges"
    }
  ],
  "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nun d\u00e9ni de service \u00e0 distance, une atteinte \u00e0 la confidentialit\u00e9 des\ndonn\u00e9es et une \u00e9l\u00e9vation de privil\u00e8ges.\n",
  "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
  "vendor_advisories": [
    {
      "published_at": null,
      "title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
      "url": null
    }
  ]
}
  CERTFR-2020-AVI-733
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans Intel AMT, ISM et Wireless Bluetooth. Elles permettent à un attaquant de provoquer un déni de service à distance, une atteinte à la confidentialité des données et une élévation de privilèges.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Intel | N/A | Intel Wireless Bluetooth versions antérieures à 21.110 | ||
| Intel | N/A | Intel Server Platform Services versions antérieures à SPS_E5_04.01.04.400, SPS_E3_05.01.04.200, SPS_E3_04.01.04.200, SPS_SoC-X_04.00.04.200 et SPS_SoC-A_04.00.04.300 | ||
| Intel | N/A | Intel CSME et Intel AMT versions antérieures à 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 et 14.5.25 | ||
| Intel | N/A | Intel TXE versions antérieures à 3.1.80 et 4.0.30 | ||
| Intel | N/A | Intel Active Management Technology (AMT) et Intel Standard Manageability (ISM) versions antérieures à 11.8.80, 11.12.80, 11.22.80, 12.0.70 et 14.0.45 (pour la vulnérabilité critique CVE-2020-8752) | 
| Title | Publication Time | Tags | ||||||
|---|---|---|---|---|---|---|---|---|
                  
  | 
              ||||||||
{
  "$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
  "affected_systems": [
    {
      "description": "Intel Wireless Bluetooth versions ant\u00e9rieures \u00e0 21.110",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Intel",
          "scada": false
        }
      }
    },
    {
      "description": "Intel Server Platform Services versions ant\u00e9rieures \u00e0 SPS_E5_04.01.04.400, SPS_E3_05.01.04.200, SPS_E3_04.01.04.200, SPS_SoC-X_04.00.04.200 et SPS_SoC-A_04.00.04.300",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Intel",
          "scada": false
        }
      }
    },
    {
      "description": "Intel CSME et Intel AMT versions ant\u00e9rieures \u00e0 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 et 14.5.25",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Intel",
          "scada": false
        }
      }
    },
    {
      "description": "Intel TXE versions ant\u00e9rieures \u00e0 3.1.80 et 4.0.30",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Intel",
          "scada": false
        }
      }
    },
    {
      "description": "Intel Active Management Technology (AMT) et Intel Standard Manageability (ISM) versions ant\u00e9rieures \u00e0 11.8.80, 11.12.80, 11.22.80, 12.0.70 et 14.0.45 (pour la vuln\u00e9rabilit\u00e9 critique CVE-2020-8752)",
      "product": {
        "name": "N/A",
        "vendor": {
          "name": "Intel",
          "scada": false
        }
      }
    }
  ],
  "affected_systems_content": null,
  "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
  "cves": [
    {
      "name": "CVE-2020-8761",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-8761"
    },
    {
      "name": "CVE-2020-8755",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-8755"
    },
    {
      "name": "CVE-2020-8745",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-8745"
    },
    {
      "name": "CVE-2020-12354",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-12354"
    },
    {
      "name": "CVE-2020-12297",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-12297"
    },
    {
      "name": "CVE-2020-12356",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-12356"
    },
    {
      "name": "CVE-2020-8753",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-8753"
    },
    {
      "name": "CVE-2020-8757",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-8757"
    },
    {
      "name": "CVE-2020-8749",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-8749"
    },
    {
      "name": "CVE-2020-12355",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-12355"
    },
    {
      "name": "CVE-2020-12322",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-12322"
    },
    {
      "name": "CVE-2020-8760",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-8760"
    },
    {
      "name": "CVE-2020-12321",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-12321"
    },
    {
      "name": "CVE-2020-12303",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-12303"
    },
    {
      "name": "CVE-2020-8751",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-8751"
    },
    {
      "name": "CVE-2020-8746",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-8746"
    },
    {
      "name": "CVE-2020-8754",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-8754"
    },
    {
      "name": "CVE-2020-8705",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-8705"
    },
    {
      "name": "CVE-2020-8756",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-8756"
    },
    {
      "name": "CVE-2020-8750",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-8750"
    },
    {
      "name": "CVE-2020-12304",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-12304"
    },
    {
      "name": "CVE-2020-8747",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-8747"
    },
    {
      "name": "CVE-2020-8744",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-8744"
    },
    {
      "name": "CVE-2020-8752",
      "url": "https://www.cve.org/CVERecord?id=CVE-2020-8752"
    }
  ],
  "initial_release_date": "2020-11-12T00:00:00",
  "last_revision_date": "2020-11-12T00:00:00",
  "links": [],
  "reference": "CERTFR-2020-AVI-733",
  "revisions": [
    {
      "description": "Version initiale",
      "revision_date": "2020-11-12T00:00:00.000000"
    }
  ],
  "risks": [
    {
      "description": "D\u00e9ni de service \u00e0 distance"
    },
    {
      "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
    },
    {
      "description": "\u00c9l\u00e9vation de privil\u00e8ges"
    }
  ],
  "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans Intel AMT, ISM et\nWireless Bluetooth. Elles permettent \u00e0 un attaquant de provoquer un d\u00e9ni\nde service \u00e0 distance, une atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es et\nune \u00e9l\u00e9vation de privil\u00e8ges.\n",
  "title": "Multiples vuln\u00e9rabilit\u00e9s dans Intel AMT, ISM et Wireless Bluetooth",
  "vendor_advisories": [
    {
      "published_at": null,
      "title": "Bulletin de s\u00e9curit\u00e9 Intel intel-sa-00403 du 10 novembre 2020",
      "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00403.html"
    },
    {
      "published_at": null,
      "title": "Bulletin de s\u00e9curit\u00e9 Intel intel-sa-00391 du 10 novembre 2020",
      "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391.html"
    }
  ]
}
  gsd-2020-8745
Vulnerability from gsd
{
  "GSD": {
    "alias": "CVE-2020-8745",
    "description": "Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 may allow an unauthenticated user to potentially enable escalation of privilege via physical access.",
    "id": "GSD-2020-8745"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2020-8745"
      ],
      "details": "Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 may allow an unauthenticated user to potentially enable escalation of privilege via physical access.",
      "id": "GSD-2020-8745",
      "modified": "2023-12-13T01:21:54.417104Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "secure@intel.com",
        "ID": "CVE-2020-8745",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "Intel(R) CSME, Intel(R) TXE",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "n/a"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 may allow an unauthenticated user to potentially enable escalation of privilege via physical access."
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "escalation of privilege"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391",
            "refsource": "MISC",
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391"
          },
          {
            "name": "https://security.netapp.com/advisory/ntap-20201113-0005/",
            "refsource": "CONFIRM",
            "url": "https://security.netapp.com/advisory/ntap-20201113-0005/"
          },
          {
            "name": "https://security.netapp.com/advisory/ntap-20201113-0002/",
            "refsource": "CONFIRM",
            "url": "https://security.netapp.com/advisory/ntap-20201113-0002/"
          },
          {
            "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf",
            "refsource": "CONFIRM",
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "11.8.80",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "11.12.80",
                "versionStartIncluding": "11.12.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "11.22.80",
                "versionStartIncluding": "11.22.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "12.0.70",
                "versionStartIncluding": "12.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "14.0.45",
                "versionStartIncluding": "14.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "14.5.25",
                "versionStartIncluding": "14.5.0",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          },
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:intel:trusted_execution_technology:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "3.1.80",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:intel:trusted_execution_technology:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.0.30",
                "versionStartIncluding": "4.0",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_drive_controller_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "05.00.01.00",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_drive_controller:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et200sp_1515sp_pc2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "0209.0105",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et200sp_1515sp_pc2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "22.01.08",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_ipc127e_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "27.01.05",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "27.01.05",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "27.01.05",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_ipc477e_pro:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_ipc527g_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.4.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_ipc527g:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_ipc547g_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "r1.30.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_ipc547g:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_ipc627e_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "25.02.08",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_ipc647e_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "25.02.08",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_ipc667e_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "25.02.08",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_ipc667e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_ipc847e_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "25.02.08",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "23.01.08",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_828d_hw_pu.4_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "08.00.00.00",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinumerik_828d_hw_pu.4:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_mc_mcu_1720_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "05.00.00.00",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinumerik_mc_mcu_1720:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_one_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinumerik_one:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_840d_sl_ht_10_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinumerik_840d_sl_ht_10:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_one_ncu_1740_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "04.00.00.00",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinumerik_one_ncu_1740:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_one_ppu_1740_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "06.00.00.00",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinumerik_one_ppu_1740:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@intel.com",
          "ID": "CVE-2020-8745"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 may allow an unauthenticated user to potentially enable escalation of privilege via physical access."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "NVD-CWE-noinfo"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391",
              "refsource": "MISC",
              "tags": [
                "Vendor Advisory"
              ],
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391"
            },
            {
              "name": "https://security.netapp.com/advisory/ntap-20201113-0005/",
              "refsource": "CONFIRM",
              "tags": [
                "Third Party Advisory"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20201113-0005/"
            },
            {
              "name": "https://security.netapp.com/advisory/ntap-20201113-0002/",
              "refsource": "CONFIRM",
              "tags": [
                "Third Party Advisory"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20201113-0002/"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf",
              "refsource": "CONFIRM",
              "tags": [
                "Patch",
                "Third Party Advisory"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.6,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "PARTIAL",
            "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 6.4,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "MEDIUM",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 0.9,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2022-10-14T11:23Z",
      "publishedDate": "2020-11-12T18:15Z"
    }
  }
}
  var-202011-1387
Vulnerability from variot
Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 may allow an unauthenticated user to potentially enable escalation of privilege via physical access. Intel(R) CSME and TXE Contains a privilege management vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state
Show details on source website{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202011-1387",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "converged security and manageability engine",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "intel",
        "version": "11.22.80"
      },
      {
        "model": "simatic ipc427e",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "27.01.05"
      },
      {
        "model": "simatic et200sp 1515sp pc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "0209.0105"
      },
      {
        "model": "sinumerik 840d sl ht 10",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinumerik 828d hw pu.4",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "08.00.00.00"
      },
      {
        "model": "converged security and manageability engine",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "intel",
        "version": "14.0.45"
      },
      {
        "model": "simatic ipc527g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.4.0"
      },
      {
        "model": "simatic ipc627e",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "25.02.08"
      },
      {
        "model": "simatic ipc847e",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "25.02.08"
      },
      {
        "model": "simatic ipc647e",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "25.02.08"
      },
      {
        "model": "simatic ipc667e",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "25.02.08"
      },
      {
        "model": "converged security and manageability engine",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "intel",
        "version": "12.0"
      },
      {
        "model": "simatic ipc127e",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "27.01.05"
      },
      {
        "model": "simatic itp1000",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "23.01.08"
      },
      {
        "model": "simatic drive controller",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "05.00.01.00"
      },
      {
        "model": "converged security and manageability engine",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "intel",
        "version": "11.8.80"
      },
      {
        "model": "converged security and manageability engine",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "intel",
        "version": "14.5.0"
      },
      {
        "model": "converged security and manageability engine",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "intel",
        "version": "14.5.25"
      },
      {
        "model": "sinumerik mc mcu 1720",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "05.00.00.00"
      },
      {
        "model": "sinumerik one",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinumerik one ncu 1740",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "04.00.00.00"
      },
      {
        "model": "trusted execution technology",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "intel",
        "version": "4.0.30"
      },
      {
        "model": "trusted execution technology",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "intel",
        "version": "4.0"
      },
      {
        "model": "simatic field pg m6",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "converged security and manageability engine",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "intel",
        "version": "14.0"
      },
      {
        "model": "sinumerik one ppu 1740",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "06.00.00.00"
      },
      {
        "model": "converged security and manageability engine",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "intel",
        "version": "11.12.80"
      },
      {
        "model": "simatic ipc477e",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "27.01.05"
      },
      {
        "model": "simatic ipc547g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "r1.30.0"
      },
      {
        "model": "simatic field pg m5",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "22.01.08"
      },
      {
        "model": "converged security and manageability engine",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "intel",
        "version": "11.22.0"
      },
      {
        "model": "trusted execution technology",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "intel",
        "version": "3.1.80"
      },
      {
        "model": "converged security and manageability engine",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "intel",
        "version": "12.0.70"
      },
      {
        "model": "converged security and manageability engine",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "intel",
        "version": "11.12.0"
      },
      {
        "model": "trusted execution technology",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30a4\u30f3\u30c6\u30eb",
        "version": null
      },
      {
        "model": "intel csme",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30a4\u30f3\u30c6\u30eb",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-013418"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-8745"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemen reported these vulnerabilities to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-1653"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2020-8745",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.6,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-8745",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.6,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "id": "VHN-186870",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:L/AC:L/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 0.9,
            "id": "CVE-2020-8745",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Physical",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 6.8,
            "baseSeverity": "Medium",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2020-8745",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-8745",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2020-8745",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201911-1653",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-186870",
            "trust": 0.1,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2020-8745",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-186870"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-8745"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-013418"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-1653"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-8745"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 may allow an unauthenticated user to potentially enable escalation of privilege via physical access. Intel(R) CSME and TXE Contains a privilege management vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-8745"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-013418"
      },
      {
        "db": "VULHUB",
        "id": "VHN-186870"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-8745"
      }
    ],
    "trust": 1.8
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-8745",
        "trust": 2.6
      },
      {
        "db": "SIEMENS",
        "id": "SSA-678983",
        "trust": 1.8
      },
      {
        "db": "JVN",
        "id": "JVNVU91051134",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-013418",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-132-05",
        "trust": 0.7
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2020.3958.2",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2020.3958",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2022.2355",
        "trust": 0.6
      },
      {
        "db": "LENOVO",
        "id": "LEN-39432",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-1653",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-186870",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-8745",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-186870"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-8745"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-013418"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-1653"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-8745"
      }
    ]
  },
  "id": "VAR-202011-1387",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-186870"
      }
    ],
    "trust": 0.77708335
  },
  "last_update_date": "2024-11-23T21:18:20.183000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "INTEL-SA-00391",
        "trust": 0.8,
        "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391.html"
      },
      {
        "title": "Intel TXE Security vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=134975"
      },
      {
        "title": "Siemens Security Advisories: Siemens Security Advisory",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=0bfef52a44075162940391ee650c313e"
      },
      {
        "title": "HP: HPSBHF03703 rev. 1  -  Intel\u00ae 2020.2 IPU - CSME, SPS, TXE, AMT, and DAL Security Update",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=hp_bulletin\u0026qid=HPSBHF03703"
      },
      {
        "title": "HP: SUPPORT COMMUNICATION- SECURITY BULLETIN\nHPSBHF03703 rev. 4  -  Intel\u00ae 2020.2 IPU - CSME, SPS, TXE, AMT, and DAL Security Update",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=hp_bulletin\u0026qid=c2cb4814b580012b6267520bd227e8ae"
      },
      {
        "title": "HP: SUPPORT COMMUNICATION- SECURITY BULLETIN\nHPSBHF03703 rev. 4  -  Intel\u00ae 2020.2 IPU - CSME, SPS, TXE, AMT, and DAL Security Update",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=hp_bulletin\u0026qid=f5eb680d1c7e445b4a8fdf769d4117b0"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2020-8745"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-013418"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-1653"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-noinfo",
        "trust": 1.0
      },
      {
        "problemtype": "Improper authority management (CWE-269) [NVD Evaluation ]",
        "trust": 0.8
      },
      {
        "problemtype": "CWE-269",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-186870"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-013418"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-8745"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf"
      },
      {
        "trust": 1.8,
        "url": "https://security.netapp.com/advisory/ntap-20201113-0002/"
      },
      {
        "trust": 1.8,
        "url": "https://security.netapp.com/advisory/ntap-20201113-0005/"
      },
      {
        "trust": 1.8,
        "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-8745"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91051134/"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2020.3958/"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-132-05"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2020.3958.2/"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2022.2355"
      },
      {
        "trust": 0.6,
        "url": "https://support.lenovo.com/us/en/product_security/len-39432"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/intel-processors-multiple-vulnerabilities-via-csme-sps-txe-amt-dal-33887"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-132-05"
      },
      {
        "trust": 0.1,
        "url": "https://support.hp.com/us-en/document/c06962103"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-186870"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-8745"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-013418"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-1653"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-8745"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-186870"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-8745"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-013418"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-1653"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-8745"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-11-12T00:00:00",
        "db": "VULHUB",
        "id": "VHN-186870"
      },
      {
        "date": "2020-11-12T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-8745"
      },
      {
        "date": "2021-07-02T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-013418"
      },
      {
        "date": "2019-11-10T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201911-1653"
      },
      {
        "date": "2020-11-12T18:15:17.300000",
        "db": "NVD",
        "id": "CVE-2020-8745"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-10-14T00:00:00",
        "db": "VULHUB",
        "id": "VHN-186870"
      },
      {
        "date": "2021-07-21T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-8745"
      },
      {
        "date": "2021-07-02T04:36:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-013418"
      },
      {
        "date": "2022-10-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201911-1653"
      },
      {
        "date": "2024-11-21T05:39:22.207000",
        "db": "NVD",
        "id": "CVE-2020-8745"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Intel(R)\u00a0CSME\u00a0 and \u00a0TXE\u00a0 Vulnerability in privilege management",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-013418"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-1653"
      }
    ],
    "trust": 0.6
  }
}
  ICSA-22-132-05
Vulnerability from csaf_cisa
Notes
{
  "document": {
    "acknowledgments": [
      {
        "organization": "Siemens",
        "summary": "reporting these vulnerabilities to CISA"
      }
    ],
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited",
      "tlp": {
        "label": "WHITE",
        "url": "https://us-cert.cisa.gov/tlp/"
      }
    },
    "lang": "en-US",
    "notes": [
      {
        "category": "general",
        "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
        "title": "CISA Disclaimer"
      },
      {
        "category": "legal_disclaimer",
        "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
        "title": "Legal Notice"
      },
      {
        "category": "summary",
        "text": "Successful exploitation of these vulnerabilities may allow an authenticated user to enable escalation of privilege via local access.",
        "title": "Risk evaluation"
      },
      {
        "category": "other",
        "text": "Multiple Sectors",
        "title": "Critical infrastructure sectors"
      },
      {
        "category": "other",
        "text": "Worldwide",
        "title": "Countries/areas deployed"
      },
      {
        "category": "other",
        "text": "Germany",
        "title": "Company headquarters location"
      },
      {
        "category": "general",
        "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "other",
        "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.",
        "title": "Exploitability"
      }
    ],
    "publisher": {
      "category": "coordinator",
      "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
      "name": "CISA",
      "namespace": "https://www.cisa.gov/"
    },
    "references": [
      {
        "category": "external",
        "summary": "SSA-678983: Vulnerabilities in Industrial PCs and CNC devices using Intel CPUs (November 2020) - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-678983.json"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-22-132-05 JSON",
        "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-132-05.json"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-22-132-05 Web Version",
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-132-05"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
      },
      {
        "category": "external",
        "summary": "SSA-678983: Vulnerabilities in Industrial PCs and CNC devices using Intel CPUs (November 2020) - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf"
      },
      {
        "category": "external",
        "summary": "SSA-678983: Vulnerabilities in Industrial PCs and CNC devices using Intel CPUs (November 2020) - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-678983.txt"
      }
    ],
    "title": "Siemens Industrial PCs and CNC devices",
    "tracking": {
      "current_release_date": "2022-05-12T00:00:00.000000Z",
      "generator": {
        "engine": {
          "name": "CISA CSAF Generator",
          "version": "1.0.0"
        }
      },
      "id": "ICSA-22-132-05",
      "initial_release_date": "2022-05-12T00:00:00.000000Z",
      "revision_history": [
        {
          "date": "2022-05-12T00:00:00.000000Z",
          "legacy_version": "Initial",
          "number": "1",
          "summary": "ICSA-22-132-05 Siemens Industrial PCs and CNC devices"
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V05.00.01.00",
                "product": {
                  "name": "SIMATIC Drive Controller family",
                  "product_id": "CSAFPID-0001"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC Drive Controller family"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V0209_0105",
                "product": {
                  "name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
                  "product_id": "CSAFPID-0002"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V22.01.08",
                "product": {
                  "name": "SIMATIC Field PG M5",
                  "product_id": "CSAFPID-0003"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC Field PG M5"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V26.01.08",
                "product": {
                  "name": "SIMATIC Field PG M6",
                  "product_id": "CSAFPID-0004"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC Field PG M6"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC IPC127E",
                  "product_id": "CSAFPID-0005"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC127E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V21.01.15",
                "product": {
                  "name": "SIMATIC IPC427E (incl. SIPLUS variants)",
                  "product_id": "CSAFPID-0006"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC427E (incl. SIPLUS variants)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V21.01.15",
                "product": {
                  "name": "SIMATIC IPC477E",
                  "product_id": "CSAFPID-0007"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC477E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V21.01.15",
                "product": {
                  "name": "SIMATIC IPC477E Pro",
                  "product_id": "CSAFPID-0008"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC477E Pro"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V1.4.0",
                "product": {
                  "name": "SIMATIC IPC527G",
                  "product_id": "CSAFPID-0009"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC527G"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c R1.30.0",
                "product": {
                  "name": "SIMATIC IPC547G",
                  "product_id": "CSAFPID-00010"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC547G"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V25.02.08",
                "product": {
                  "name": "SIMATIC IPC627E",
                  "product_id": "CSAFPID-00011"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC627E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V25.02.08",
                "product": {
                  "name": "SIMATIC IPC647E",
                  "product_id": "CSAFPID-00012"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC647E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V25.02.08",
                "product": {
                  "name": "SIMATIC IPC677E",
                  "product_id": "CSAFPID-00013"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC677E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V25.02.08",
                "product": {
                  "name": "SIMATIC IPC847E",
                  "product_id": "CSAFPID-00014"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC847E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V23.01.08",
                "product": {
                  "name": "SIMATIC ITP1000",
                  "product_id": "CSAFPID-00015"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC ITP1000"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All Versions \u003c V08.00.00.00",
                "product": {
                  "name": "SINUMERIK 828D HW PU.4",
                  "product_id": "CSAFPID-00016"
                }
              }
            ],
            "category": "product_name",
            "name": "SINUMERIK 828D HW PU.4"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V05.00.00.00",
                "product": {
                  "name": "SINUMERIK MC MCU 1720",
                  "product_id": "CSAFPID-00017"
                }
              }
            ],
            "category": "product_name",
            "name": "SINUMERIK MC MCU 1720"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V08.00.00.00",
                "product": {
                  "name": "SINUMERIK ONE / SINUMERIK 840D sl Handheld Terminal HT 10",
                  "product_id": "CSAFPID-00018"
                }
              }
            ],
            "category": "product_name",
            "name": "SINUMERIK ONE / SINUMERIK 840D sl Handheld Terminal HT 10"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V04.00.00.00",
                "product": {
                  "name": "SINUMERIK ONE NCU 1740",
                  "product_id": "CSAFPID-00019"
                }
              }
            ],
            "category": "product_name",
            "name": "SINUMERIK ONE NCU 1740"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V06.00.00.00",
                "product": {
                  "name": "SINUMERIK ONE PPU 1740",
                  "product_id": "CSAFPID-00020"
                }
              }
            ],
            "category": "product_name",
            "name": "SINUMERIK ONE PPU 1740"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2020-0590",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Improper input validation in BIOS firmware for some Intel Processors may\nallow an authenticated user to potentially enable escalation of privilege\nvia local access. CVE-2020-0590 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0004",
          "CSAFPID-0009",
          "CSAFPID-00010",
          "CSAFPID-00011",
          "CSAFPID-00012",
          "CSAFPID-00013",
          "CSAFPID-00014"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-0590"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible.",
          "product_ids": [
            "CSAFPID-0004",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014"
          ]
        },
        {
          "category": "mitigation",
          "details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: \nhttps://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0004",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V26.01.08 or later version",
          "product_ids": [
            "CSAFPID-0004"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V1.4.0 or later version",
          "product_ids": [
            "CSAFPID-0009"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to R1.30.0 or later version",
          "product_ids": [
            "CSAFPID-00010"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V25.02.08 or later version",
          "product_ids": [
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: \nhttps://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0004",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0004",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014"
          ]
        }
      ],
      "title": "CVE-2020-0590"
    },
    {
      "cve": "CVE-2020-8694",
      "cwe": {
        "id": "CWE-287",
        "name": "Improper Authentication"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Insufficient access control in the Linux kernel driver for some\nIntel Processors may allow an authenticated user to potentially enable\ninformation disclosure via local access. CVE-2020-8694 has been assigned to this vulnerability. A CVSS v3 base score of 5.6 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N).",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0003",
          "CSAFPID-0004",
          "CSAFPID-0006",
          "CSAFPID-0007",
          "CSAFPID-0008",
          "CSAFPID-0009",
          "CSAFPID-00010",
          "CSAFPID-00011",
          "CSAFPID-00012",
          "CSAFPID-00013",
          "CSAFPID-00014",
          "CSAFPID-00015"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8694"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N/E:P/RL:O/RC:C"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible.",
          "product_ids": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015"
          ]
        },
        {
          "category": "mitigation",
          "details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: \nhttps://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V22.01.08 or later version",
          "product_ids": [
            "CSAFPID-0003"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V26.01.08 or later version",
          "product_ids": [
            "CSAFPID-0004"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V21.01.15 or later version",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V1.4.0 or later version",
          "product_ids": [
            "CSAFPID-0009"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to R1.30.0 or later version",
          "product_ids": [
            "CSAFPID-00010"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V25.02.08 or later version",
          "product_ids": [
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V23.01.08 or later version",
          "product_ids": [
            "CSAFPID-00015"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: \nhttps://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.6,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015"
          ]
        }
      ],
      "title": "CVE-2020-8694"
    },
    {
      "cve": "CVE-2020-8698",
      "cwe": {
        "id": "CWE-1189",
        "name": "Improper Isolation of Shared Resources on System-on-a-Chip (SoC)"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Improper isolation of shared resources in some Intel Processors may allow an\nauthenticated user to potentially enable information disclosure via local access. CVE-2020-8698 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0003",
          "CSAFPID-0004",
          "CSAFPID-0006",
          "CSAFPID-0007",
          "CSAFPID-0008",
          "CSAFPID-00011",
          "CSAFPID-00012",
          "CSAFPID-00013",
          "CSAFPID-00014",
          "CSAFPID-00015"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8698"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible.",
          "product_ids": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015"
          ]
        },
        {
          "category": "mitigation",
          "details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: \nhttps://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V22.01.08 or later version",
          "product_ids": [
            "CSAFPID-0003"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V26.01.08 or later version",
          "product_ids": [
            "CSAFPID-0004"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V21.01.15 or later version",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V25.02.08 or later version",
          "product_ids": [
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V23.01.08 or later version",
          "product_ids": [
            "CSAFPID-00015"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: \nhttps://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015"
          ]
        }
      ],
      "title": "CVE-2020-8698"
    },
    {
      "cve": "CVE-2020-8745",
      "cwe": {
        "id": "CWE-269",
        "name": "Improper Privilege Management"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 may allow an unauthenticated user to potentially enable escalation of privilege via physical access. CVE-2020-8745 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003",
          "CSAFPID-0004",
          "CSAFPID-0005",
          "CSAFPID-0006",
          "CSAFPID-0007",
          "CSAFPID-0008",
          "CSAFPID-0009",
          "CSAFPID-00011",
          "CSAFPID-00012",
          "CSAFPID-00013",
          "CSAFPID-00014",
          "CSAFPID-00015",
          "CSAFPID-00016",
          "CSAFPID-00017",
          "CSAFPID-00018",
          "CSAFPID-00019",
          "CSAFPID-00020"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8745"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00018",
            "CSAFPID-00019",
            "CSAFPID-00020"
          ]
        },
        {
          "category": "mitigation",
          "details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: \nhttps://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00018",
            "CSAFPID-00019",
            "CSAFPID-00020"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V22.01.08 or later version",
          "product_ids": [
            "CSAFPID-0003"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V26.01.08 or later version",
          "product_ids": [
            "CSAFPID-0004"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V27.01.05 or later version",
          "product_ids": [
            "CSAFPID-0005"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V21.01.15 or later version",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V1.4.0 or later version",
          "product_ids": [
            "CSAFPID-0009"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V25.02.08 or later version",
          "product_ids": [
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V23.01.08 or later version",
          "product_ids": [
            "CSAFPID-00015"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V0209_0105 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109743969/"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00017"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V08.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00016",
            "CSAFPID-00018"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V06.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00020"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.01.00 or later version\nThe update can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-0001"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V04.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00019"
          ]
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: \nhttps://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00018",
            "CSAFPID-00019",
            "CSAFPID-00020"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00018",
            "CSAFPID-00019",
            "CSAFPID-00020"
          ]
        }
      ],
      "title": "CVE-2020-8745"
    }
  ]
}
  icsa-22-132-05
Vulnerability from csaf_cisa
Notes
{
  "document": {
    "acknowledgments": [
      {
        "organization": "Siemens",
        "summary": "reporting these vulnerabilities to CISA"
      }
    ],
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited",
      "tlp": {
        "label": "WHITE",
        "url": "https://us-cert.cisa.gov/tlp/"
      }
    },
    "lang": "en-US",
    "notes": [
      {
        "category": "general",
        "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
        "title": "CISA Disclaimer"
      },
      {
        "category": "legal_disclaimer",
        "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
        "title": "Legal Notice"
      },
      {
        "category": "summary",
        "text": "Successful exploitation of these vulnerabilities may allow an authenticated user to enable escalation of privilege via local access.",
        "title": "Risk evaluation"
      },
      {
        "category": "other",
        "text": "Multiple Sectors",
        "title": "Critical infrastructure sectors"
      },
      {
        "category": "other",
        "text": "Worldwide",
        "title": "Countries/areas deployed"
      },
      {
        "category": "other",
        "text": "Germany",
        "title": "Company headquarters location"
      },
      {
        "category": "general",
        "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "other",
        "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.",
        "title": "Exploitability"
      }
    ],
    "publisher": {
      "category": "coordinator",
      "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
      "name": "CISA",
      "namespace": "https://www.cisa.gov/"
    },
    "references": [
      {
        "category": "external",
        "summary": "SSA-678983: Vulnerabilities in Industrial PCs and CNC devices using Intel CPUs (November 2020) - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-678983.json"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-22-132-05 JSON",
        "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-132-05.json"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-22-132-05 Web Version",
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-132-05"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
      },
      {
        "category": "external",
        "summary": "SSA-678983: Vulnerabilities in Industrial PCs and CNC devices using Intel CPUs (November 2020) - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf"
      },
      {
        "category": "external",
        "summary": "SSA-678983: Vulnerabilities in Industrial PCs and CNC devices using Intel CPUs (November 2020) - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-678983.txt"
      }
    ],
    "title": "Siemens Industrial PCs and CNC devices",
    "tracking": {
      "current_release_date": "2022-05-12T00:00:00.000000Z",
      "generator": {
        "engine": {
          "name": "CISA CSAF Generator",
          "version": "1.0.0"
        }
      },
      "id": "ICSA-22-132-05",
      "initial_release_date": "2022-05-12T00:00:00.000000Z",
      "revision_history": [
        {
          "date": "2022-05-12T00:00:00.000000Z",
          "legacy_version": "Initial",
          "number": "1",
          "summary": "ICSA-22-132-05 Siemens Industrial PCs and CNC devices"
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V05.00.01.00",
                "product": {
                  "name": "SIMATIC Drive Controller family",
                  "product_id": "CSAFPID-0001"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC Drive Controller family"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V0209_0105",
                "product": {
                  "name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
                  "product_id": "CSAFPID-0002"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V22.01.08",
                "product": {
                  "name": "SIMATIC Field PG M5",
                  "product_id": "CSAFPID-0003"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC Field PG M5"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V26.01.08",
                "product": {
                  "name": "SIMATIC Field PG M6",
                  "product_id": "CSAFPID-0004"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC Field PG M6"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC IPC127E",
                  "product_id": "CSAFPID-0005"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC127E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V21.01.15",
                "product": {
                  "name": "SIMATIC IPC427E (incl. SIPLUS variants)",
                  "product_id": "CSAFPID-0006"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC427E (incl. SIPLUS variants)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V21.01.15",
                "product": {
                  "name": "SIMATIC IPC477E",
                  "product_id": "CSAFPID-0007"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC477E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V21.01.15",
                "product": {
                  "name": "SIMATIC IPC477E Pro",
                  "product_id": "CSAFPID-0008"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC477E Pro"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V1.4.0",
                "product": {
                  "name": "SIMATIC IPC527G",
                  "product_id": "CSAFPID-0009"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC527G"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c R1.30.0",
                "product": {
                  "name": "SIMATIC IPC547G",
                  "product_id": "CSAFPID-00010"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC547G"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V25.02.08",
                "product": {
                  "name": "SIMATIC IPC627E",
                  "product_id": "CSAFPID-00011"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC627E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V25.02.08",
                "product": {
                  "name": "SIMATIC IPC647E",
                  "product_id": "CSAFPID-00012"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC647E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V25.02.08",
                "product": {
                  "name": "SIMATIC IPC677E",
                  "product_id": "CSAFPID-00013"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC677E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V25.02.08",
                "product": {
                  "name": "SIMATIC IPC847E",
                  "product_id": "CSAFPID-00014"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC IPC847E"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All BIOS versions \u003c V23.01.08",
                "product": {
                  "name": "SIMATIC ITP1000",
                  "product_id": "CSAFPID-00015"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC ITP1000"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All Versions \u003c V08.00.00.00",
                "product": {
                  "name": "SINUMERIK 828D HW PU.4",
                  "product_id": "CSAFPID-00016"
                }
              }
            ],
            "category": "product_name",
            "name": "SINUMERIK 828D HW PU.4"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V05.00.00.00",
                "product": {
                  "name": "SINUMERIK MC MCU 1720",
                  "product_id": "CSAFPID-00017"
                }
              }
            ],
            "category": "product_name",
            "name": "SINUMERIK MC MCU 1720"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V08.00.00.00",
                "product": {
                  "name": "SINUMERIK ONE / SINUMERIK 840D sl Handheld Terminal HT 10",
                  "product_id": "CSAFPID-00018"
                }
              }
            ],
            "category": "product_name",
            "name": "SINUMERIK ONE / SINUMERIK 840D sl Handheld Terminal HT 10"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V04.00.00.00",
                "product": {
                  "name": "SINUMERIK ONE NCU 1740",
                  "product_id": "CSAFPID-00019"
                }
              }
            ],
            "category": "product_name",
            "name": "SINUMERIK ONE NCU 1740"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V06.00.00.00",
                "product": {
                  "name": "SINUMERIK ONE PPU 1740",
                  "product_id": "CSAFPID-00020"
                }
              }
            ],
            "category": "product_name",
            "name": "SINUMERIK ONE PPU 1740"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2020-0590",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Improper input validation in BIOS firmware for some Intel Processors may\nallow an authenticated user to potentially enable escalation of privilege\nvia local access. CVE-2020-0590 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0004",
          "CSAFPID-0009",
          "CSAFPID-00010",
          "CSAFPID-00011",
          "CSAFPID-00012",
          "CSAFPID-00013",
          "CSAFPID-00014"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-0590"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible.",
          "product_ids": [
            "CSAFPID-0004",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014"
          ]
        },
        {
          "category": "mitigation",
          "details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: \nhttps://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0004",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V26.01.08 or later version",
          "product_ids": [
            "CSAFPID-0004"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V1.4.0 or later version",
          "product_ids": [
            "CSAFPID-0009"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to R1.30.0 or later version",
          "product_ids": [
            "CSAFPID-00010"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V25.02.08 or later version",
          "product_ids": [
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: \nhttps://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0004",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0004",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014"
          ]
        }
      ],
      "title": "CVE-2020-0590"
    },
    {
      "cve": "CVE-2020-8694",
      "cwe": {
        "id": "CWE-287",
        "name": "Improper Authentication"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Insufficient access control in the Linux kernel driver for some\nIntel Processors may allow an authenticated user to potentially enable\ninformation disclosure via local access. CVE-2020-8694 has been assigned to this vulnerability. A CVSS v3 base score of 5.6 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N).",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0003",
          "CSAFPID-0004",
          "CSAFPID-0006",
          "CSAFPID-0007",
          "CSAFPID-0008",
          "CSAFPID-0009",
          "CSAFPID-00010",
          "CSAFPID-00011",
          "CSAFPID-00012",
          "CSAFPID-00013",
          "CSAFPID-00014",
          "CSAFPID-00015"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8694"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N/E:P/RL:O/RC:C"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible.",
          "product_ids": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015"
          ]
        },
        {
          "category": "mitigation",
          "details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: \nhttps://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V22.01.08 or later version",
          "product_ids": [
            "CSAFPID-0003"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V26.01.08 or later version",
          "product_ids": [
            "CSAFPID-0004"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V21.01.15 or later version",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V1.4.0 or later version",
          "product_ids": [
            "CSAFPID-0009"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to R1.30.0 or later version",
          "product_ids": [
            "CSAFPID-00010"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V25.02.08 or later version",
          "product_ids": [
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V23.01.08 or later version",
          "product_ids": [
            "CSAFPID-00015"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: \nhttps://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.6,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00010",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015"
          ]
        }
      ],
      "title": "CVE-2020-8694"
    },
    {
      "cve": "CVE-2020-8698",
      "cwe": {
        "id": "CWE-1189",
        "name": "Improper Isolation of Shared Resources on System-on-a-Chip (SoC)"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Improper isolation of shared resources in some Intel Processors may allow an\nauthenticated user to potentially enable information disclosure via local access. CVE-2020-8698 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0003",
          "CSAFPID-0004",
          "CSAFPID-0006",
          "CSAFPID-0007",
          "CSAFPID-0008",
          "CSAFPID-00011",
          "CSAFPID-00012",
          "CSAFPID-00013",
          "CSAFPID-00014",
          "CSAFPID-00015"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8698"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible.",
          "product_ids": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015"
          ]
        },
        {
          "category": "mitigation",
          "details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: \nhttps://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V22.01.08 or later version",
          "product_ids": [
            "CSAFPID-0003"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V26.01.08 or later version",
          "product_ids": [
            "CSAFPID-0004"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V21.01.15 or later version",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V25.02.08 or later version",
          "product_ids": [
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V23.01.08 or later version",
          "product_ids": [
            "CSAFPID-00015"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: \nhttps://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015"
          ]
        }
      ],
      "title": "CVE-2020-8698"
    },
    {
      "cve": "CVE-2020-8745",
      "cwe": {
        "id": "CWE-269",
        "name": "Improper Privilege Management"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 may allow an unauthenticated user to potentially enable escalation of privilege via physical access. CVE-2020-8745 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003",
          "CSAFPID-0004",
          "CSAFPID-0005",
          "CSAFPID-0006",
          "CSAFPID-0007",
          "CSAFPID-0008",
          "CSAFPID-0009",
          "CSAFPID-00011",
          "CSAFPID-00012",
          "CSAFPID-00013",
          "CSAFPID-00014",
          "CSAFPID-00015",
          "CSAFPID-00016",
          "CSAFPID-00017",
          "CSAFPID-00018",
          "CSAFPID-00019",
          "CSAFPID-00020"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8745"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00018",
            "CSAFPID-00019",
            "CSAFPID-00020"
          ]
        },
        {
          "category": "mitigation",
          "details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: \nhttps://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00018",
            "CSAFPID-00019",
            "CSAFPID-00020"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V22.01.08 or later version",
          "product_ids": [
            "CSAFPID-0003"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V26.01.08 or later version",
          "product_ids": [
            "CSAFPID-0004"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V27.01.05 or later version",
          "product_ids": [
            "CSAFPID-0005"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V21.01.15 or later version",
          "product_ids": [
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V1.4.0 or later version",
          "product_ids": [
            "CSAFPID-0009"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V25.02.08 or later version",
          "product_ids": [
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V23.01.08 or later version",
          "product_ids": [
            "CSAFPID-00015"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109763408"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V0209_0105 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109743969/"
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00017"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V08.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00016",
            "CSAFPID-00018"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V06.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00020"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V05.00.01.00 or later version\nThe update can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-0001"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update BIOS to V04.00.00.00 or later version\nSINUMERIK software can be obtained from your local Siemens account manager.",
          "product_ids": [
            "CSAFPID-00019"
          ]
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: \nhttps://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00018",
            "CSAFPID-00019",
            "CSAFPID-00020"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-00011",
            "CSAFPID-00012",
            "CSAFPID-00013",
            "CSAFPID-00014",
            "CSAFPID-00015",
            "CSAFPID-00016",
            "CSAFPID-00017",
            "CSAFPID-00018",
            "CSAFPID-00019",
            "CSAFPID-00020"
          ]
        }
      ],
      "title": "CVE-2020-8745"
    }
  ]
}
  ghsa-wc8w-gx27-xp92
Vulnerability from github
Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 may allow an unauthenticated user to potentially enable escalation of privilege via physical access.
{
  "affected": [],
  "aliases": [
    "CVE-2020-8745"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-269"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2020-11-12T18:15:00Z",
    "severity": "MODERATE"
  },
  "details": "Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 may allow an unauthenticated user to potentially enable escalation of privilege via physical access.",
  "id": "GHSA-wc8w-gx27-xp92",
  "modified": "2025-03-28T15:31:42Z",
  "published": "2022-05-24T17:34:11Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2020-8745"
    },
    {
      "type": "WEB",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf"
    },
    {
      "type": "WEB",
      "url": "https://security.netapp.com/advisory/ntap-20201113-0002"
    },
    {
      "type": "WEB",
      "url": "https://security.netapp.com/advisory/ntap-20201113-0005"
    },
    {
      "type": "WEB",
      "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
      "type": "CVSS_V3"
    }
  ]
}
  Sightings
| Author | Source | Type | Date | 
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
 - Confirmed: The vulnerability is confirmed from an analyst perspective.
 - Published Proof of Concept: A public proof of concept is available for this vulnerability.
 - Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
 - Patched: This vulnerability was successfully patched by the user reporting the sighting.
 - Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
 - Not confirmed: The user expresses doubt about the veracity of the vulnerability.
 - Not patched: This vulnerability was not successfully patched by the user reporting the sighting.