Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2018-17899
Vulnerability from cvelistv5
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://laquisscada.com/instale1.php | Product, Vendor Advisory | |
ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/105719 | Third Party Advisory, VDB Entry | |
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01 | Third Party Advisory, US Government Resource | |
nvd@nist.gov | https://exchange.xforce.ibmcloud.com/vulnerabilities/151420 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://laquisscada.com/instale1.php | Product, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/105719 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01 | Third Party Advisory, US Government Resource |
Vendor | Product | Version | |
---|---|---|---|
▼ | LCDS - Leão Consultoria e Desenvolvimento de Sistemas LTDA ME | LAquis SCADA |
Version: 4.1.0.3870 and prior |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:01:14.645Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://laquisscada.com/instale1.php" }, { "name": "105719", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/105719" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "LAquis SCADA", "vendor": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas LTDA ME", "versions": [ { "status": "affected", "version": "4.1.0.3870 and prior" } ] } ], "datePublic": "2018-10-16T00:00:00", "descriptions": [ { "lang": "en", "value": "LAquis SCADA Versions 4.1.0.3870 and prior has a path traversal vulnerability, which may allow remote code execution." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "PATH TRAVERSAL CWE-22", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-25T09:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "http://laquisscada.com/instale1.php" }, { "name": "105719", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/105719" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2018-10-16T00:00:00", "ID": "CVE-2018-17899", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "LAquis SCADA", "version": { "version_data": [ { "version_value": "4.1.0.3870 and prior" } ] } } ] }, "vendor_name": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas LTDA ME" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "LAquis SCADA Versions 4.1.0.3870 and prior has a path traversal vulnerability, which may allow remote code execution." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "PATH TRAVERSAL CWE-22" } ] } ] }, "references": { "reference_data": [ { "name": "http://laquisscada.com/instale1.php", "refsource": "MISC", "url": "http://laquisscada.com/instale1.php" }, { "name": "105719", "refsource": "BID", "url": "http://www.securityfocus.com/bid/105719" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-17899", "datePublished": "2018-10-17T02:00:00Z", "dateReserved": "2018-10-02T00:00:00", "dateUpdated": "2024-09-17T00:45:27.781Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2018-17899\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2018-10-17T02:29:01.000\",\"lastModified\":\"2024-11-21T03:55:10.040\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"LAquis SCADA Versions 4.1.0.3870 and prior has a path traversal vulnerability, which may allow remote code execution.\"},{\"lang\":\"es\",\"value\":\"LAquis SCADA en versiones 4.1.0.3870 y anteriores tiene una vulnerabilidad de salto de directorio que podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-22\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-22\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.1.0.3870\",\"matchCriteriaId\":\"B5F605D9-73FC-4D5B-9884-50512081BF6F\"}]}]}],\"references\":[{\"url\":\"http://laquisscada.com/instale1.php\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Product\",\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/105719\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://exchange.xforce.ibmcloud.com/vulnerabilities/151420\",\"source\":\"nvd@nist.gov\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"http://laquisscada.com/instale1.php\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Product\",\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/105719\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
var-201810-0486
Vulnerability from variot
LAquis SCADA Versions 4.1.0.3870 and prior has a path traversal vulnerability, which may allow remote code execution. LAquis SCADA Contains a path traversal vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current process. LAquis SCADA is a suite of SCADA software for monitoring and data acquisition. LAquis SCADA Smart Security Manager is prone to following multiple security vulnerabilities: 1. Remote-code execution vulnerability 2. Multiple unspecified interger overflow vulnerability 3. Directory traversal vulnerability 4. Failed attacks may cause a denial-of-service condition. LAquis SCADA mart Security Manager Versions 4.1.0.3870 and prior versions are vulnerable
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0486", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "laquis scada", "scope": "lte", "trust": 1.8, "vendor": "lcds", "version": "4.1.0.3870" }, { "model": "software", "scope": null, "trust": 0.7, "vendor": "laquis scada", "version": null }, { "model": "\\342\\200\\223 le\\303\\243o consultoria e desenvolvimento de sistemas ltda me laquis scada \u003c=4.1.0.3870", "scope": null, "trust": 0.6, "vendor": "lcds", "version": null }, { "model": "laquis scada", "scope": "eq", "trust": 0.6, "vendor": "lcds", "version": "4.1.0.3870" }, { "model": "le\u00e3o consultoria e desenvolvimento de sistemas ltda me laquis scada smart security manager", "scope": "eq", "trust": 0.3, "vendor": "lcds", "version": "-4.1.0.3870" }, { "model": "le\u00e3o consultoria e desenvolvimento de sistemas ltda me laquis scada smart security manager", "scope": "ne", "trust": 0.3, "vendor": "lcds", "version": "-4.1.0.4114" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "laquis scada", "version": "*" } ], "sources": [ { "db": "IVD", "id": "7d85b771-463f-11e9-9ac8-000c29342cb1" }, { "db": "ZDI", "id": "ZDI-18-1252" }, { "db": "CNVD", "id": "CNVD-2018-21321" }, { "db": "BID", "id": "105719" }, { "db": "JVNDB", "id": "JVNDB-2018-011035" }, { "db": "CNNVD", "id": "CNNVD-201810-761" }, { "db": "NVD", "id": "CVE-2018-17899" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:lcds:laquis_scada", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011035" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Esteban Ruiz (mr_me) of Source Incite", "sources": [ { "db": "ZDI", "id": "ZDI-18-1252" } ], "trust": 0.7 }, "cve": "CVE-2018-17899", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CVE-2018-17899", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 2.5, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2018-21321", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "7d85b771-463f-11e9-9ac8-000c29342cb1", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.9 [IVD]" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2018-17899", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-17899", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2018-17899", "trust": 0.8, "value": "High" }, { "author": "ZDI", "id": "CVE-2018-17899", "trust": 0.7, "value": "MEDIUM" }, { "author": "CNVD", "id": "CNVD-2018-21321", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201810-761", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "7d85b771-463f-11e9-9ac8-000c29342cb1", "trust": 0.2, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "7d85b771-463f-11e9-9ac8-000c29342cb1" }, { "db": "ZDI", "id": "ZDI-18-1252" }, { "db": "CNVD", "id": "CNVD-2018-21321" }, { "db": "JVNDB", "id": "JVNDB-2018-011035" }, { "db": "CNNVD", "id": "CNNVD-201810-761" }, { "db": "NVD", "id": "CVE-2018-17899" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "LAquis SCADA Versions 4.1.0.3870 and prior has a path traversal vulnerability, which may allow remote code execution. LAquis SCADA Contains a path traversal vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current process. LAquis SCADA is a suite of SCADA software for monitoring and data acquisition. LAquis SCADA Smart Security Manager is prone to following multiple security vulnerabilities:\n1. Remote-code execution vulnerability\n2. Multiple unspecified interger overflow vulnerability\n3. Directory traversal vulnerability\n4. Failed attacks may cause a denial-of-service condition. \nLAquis SCADA mart Security Manager Versions 4.1.0.3870 and prior versions are vulnerable", "sources": [ { "db": "NVD", "id": "CVE-2018-17899" }, { "db": "JVNDB", "id": "JVNDB-2018-011035" }, { "db": "ZDI", "id": "ZDI-18-1252" }, { "db": "CNVD", "id": "CNVD-2018-21321" }, { "db": "BID", "id": "105719" }, { "db": "IVD", "id": "7d85b771-463f-11e9-9ac8-000c29342cb1" } ], "trust": 3.24 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-17899", "trust": 4.2 }, { "db": "ICS CERT", "id": "ICSA-18-289-01", "trust": 2.7 }, { "db": "BID", "id": "105719", "trust": 1.9 }, { "db": "CNVD", "id": "CNVD-2018-21321", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201810-761", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2018-011035", "trust": 0.8 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-6373", "trust": 0.7 }, { "db": "ZDI", "id": "ZDI-18-1252", "trust": 0.7 }, { "db": "IVD", "id": "7D85B771-463F-11E9-9AC8-000C29342CB1", "trust": 0.2 } ], "sources": [ { "db": "IVD", "id": "7d85b771-463f-11e9-9ac8-000c29342cb1" }, { "db": "ZDI", "id": "ZDI-18-1252" }, { "db": "CNVD", "id": "CNVD-2018-21321" }, { "db": "BID", "id": "105719" }, { "db": "JVNDB", "id": "JVNDB-2018-011035" }, { "db": "CNNVD", "id": "CNNVD-201810-761" }, { "db": "NVD", "id": "CVE-2018-17899" } ] }, "id": "VAR-201810-0486", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "7d85b771-463f-11e9-9ac8-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-21321" } ], "trust": 1.5753561 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "7d85b771-463f-11e9-9ac8-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-21321" } ] }, "last_update_date": "2024-11-23T22:06:35.219000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "LAquis SCADA software", "trust": 0.8, "url": "https://laquisscada.com/instale1.php" }, { "title": "LAquis SCADA has issued an update to correct this vulnerability.", "trust": 0.7, "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01" }, { "title": "Patch for LAquis SCADA Path Traversal Vulnerability (CNVD-2018-21321)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/142797" }, { "title": "LAquis SCADA Repair measures for path traversal vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=85844" } ], "sources": [ { "db": "ZDI", "id": "ZDI-18-1252" }, { "db": "CNVD", "id": "CNVD-2018-21321" }, { "db": "JVNDB", "id": "JVNDB-2018-011035" }, { "db": "CNNVD", "id": "CNNVD-201810-761" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-22", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011035" }, { "db": "NVD", "id": "CVE-2018-17899" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.4, "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-289-01" }, { "trust": 1.9, "url": "http://laquisscada.com/instale1.php" }, { "trust": 1.6, "url": "http://www.securityfocus.com/bid/105719" }, { "trust": 1.6, "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/151420" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-17899" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-17899" } ], "sources": [ { "db": "ZDI", "id": "ZDI-18-1252" }, { "db": "CNVD", "id": "CNVD-2018-21321" }, { "db": "BID", "id": "105719" }, { "db": "JVNDB", "id": "JVNDB-2018-011035" }, { "db": "CNNVD", "id": "CNNVD-201810-761" }, { "db": "NVD", "id": "CVE-2018-17899" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "7d85b771-463f-11e9-9ac8-000c29342cb1" }, { "db": "ZDI", "id": "ZDI-18-1252" }, { "db": "CNVD", "id": "CNVD-2018-21321" }, { "db": "BID", "id": "105719" }, { "db": "JVNDB", "id": "JVNDB-2018-011035" }, { "db": "CNNVD", "id": "CNNVD-201810-761" }, { "db": "NVD", "id": "CVE-2018-17899" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-10-18T00:00:00", "db": "IVD", "id": "7d85b771-463f-11e9-9ac8-000c29342cb1" }, { "date": "2018-10-16T00:00:00", "db": "ZDI", "id": "ZDI-18-1252" }, { "date": "2018-10-18T00:00:00", "db": "CNVD", "id": "CNVD-2018-21321" }, { "date": "2018-10-16T00:00:00", "db": "BID", "id": "105719" }, { "date": "2019-01-04T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-011035" }, { "date": "2018-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-761" }, { "date": "2018-10-17T02:29:01", "db": "NVD", "id": "CVE-2018-17899" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-10-16T00:00:00", "db": "ZDI", "id": "ZDI-18-1252" }, { "date": "2019-01-23T00:00:00", "db": "CNVD", "id": "CNVD-2018-21321" }, { "date": "2018-10-16T00:00:00", "db": "BID", "id": "105719" }, { "date": "2019-01-04T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-011035" }, { "date": "2019-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-761" }, { "date": "2024-11-21T03:55:10.040000", "db": "NVD", "id": "CVE-2018-17899" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-761" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "LAquis SCADA Path traversal vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-011035" }, { "db": "CNNVD", "id": "CNNVD-201810-761" } ], "trust": 1.4 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Path traversal", "sources": [ { "db": "IVD", "id": "7d85b771-463f-11e9-9ac8-000c29342cb1" }, { "db": "CNNVD", "id": "CNNVD-201810-761" } ], "trust": 0.8 } }
ICSA-18-289-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Mat Powell", "Ashraf Alharbi (Ha5ha5hin)" ], "organization": "Trend Micro \u0027s Zero Day Initiative", "summary": "reporting these vulnerabilities to NCCIC" }, { "names": [ "rgod" ], "organization": "9SG Security Team", "summary": "reporting these vulnerabilities to NCCIC" }, { "names": [ "Esteban Ruiz (mr_me)" ], "organization": "Source Incite", "summary": "reporting these vulnerabilities to NCCIC" }, { "names": [ "b0nd @garage4hackers" ], "summary": "reporting these vulnerabilities to NCCIC" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code, crash the system, or write controlled content to the target system.", "title": "Risk evaluation" }, { "category": "other", "text": "Chemical, Commercial Facilities, Energy, Food and Agriculture, Transportation Systems, Water and Wastewater Systems", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "South America", "title": "Countries/areas deployed" }, { "category": "other", "text": "Brazil", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-18-289-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2018/icsa-18-289-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-18-289-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-18-289-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas Ltda ME LAquis SCADA", "tracking": { "current_release_date": "2018-10-16T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-18-289-01", "initial_release_date": "2018-10-16T00:00:00.000000Z", "revision_history": [ { "date": "2018-10-16T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-18-289-01 LCDS - Leao Consultoria e Desenvolvimento de Sistemas LTDA ME LAquis SCADA" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c= 4.1.0.3870", "product": { "name": "Smart Security Manager: Versions 4.1.0.3870 and prior", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Smart Security Manager" } ], "category": "vendor", "name": "LCDS - Le\u00c3\u00a3o Consultoria e Desenvolvimento de Sistemas LTDA ME" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-17893", "cwe": { "id": "CWE-822", "name": "Untrusted Pointer Dereference" }, "notes": [ { "category": "summary", "text": "An untrusted pointer dereference vulnerability has been identified, which may allow remote code execution.CVE-2018-17893 has been assigned to this vulnerability. A CVSS v3 base score of 5.6 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-17893" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L" } ], "remediations": [ { "category": "mitigation", "details": "LCDS recommends that users update to Version 4.1.0.4114, which can be found at the following location:", "product_ids": [ "CSAFPID-0001" ], "url": "http://laquisscada.com/instale1.php" } ], "scores": [ { "cvss_v3": { "baseScore": 5.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-17895", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Several out-of-bounds read vulnerabilities have been identified, which may allow remote code execution.CVE-2018-17895 has been assigned to these vulnerabilities. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-17895" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L" } ], "remediations": [ { "category": "mitigation", "details": "LCDS recommends that users update to Version 4.1.0.4114, which can be found at the following location:", "product_ids": [ "CSAFPID-0001" ], "url": "http://laquisscada.com/instale1.php" } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-17897", "cwe": { "id": "CWE-680", "name": "Integer Overflow to Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Several integer overflow to buffer overflow vulnerabilities have been identified, which may allow remote code execution.CVE-2018-17897 has been assigned to these vulnerabilities. A CVSS v3 base score of 5.6 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-17897" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L" } ], "remediations": [ { "category": "mitigation", "details": "LCDS recommends that users update to Version 4.1.0.4114, which can be found at the following location:", "product_ids": [ "CSAFPID-0001" ], "url": "http://laquisscada.com/instale1.php" } ], "scores": [ { "cvss_v3": { "baseScore": 5.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-17899", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "summary", "text": "A path traversal vulnerability has been identified, which may allow remote code execution.CVE-2018-17899 has been assigned to this vulnerability. A CVSS v3 base score of 6.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-17899" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L" } ], "remediations": [ { "category": "mitigation", "details": "LCDS recommends that users update to Version 4.1.0.4114, which can be found at the following location:", "product_ids": [ "CSAFPID-0001" ], "url": "http://laquisscada.com/instale1.php" } ], "scores": [ { "cvss_v3": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-17901", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "When processing project files the application fails to sanitize user input prior to performing write operations on a stack object, which may allow an attacker to execute code under the current process.CVE-2018-17901 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-17901" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L" } ], "remediations": [ { "category": "mitigation", "details": "LCDS recommends that users update to Version 4.1.0.4114, which can be found at the following location:", "product_ids": [ "CSAFPID-0001" ], "url": "http://laquisscada.com/instale1.php" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-17911", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Several stack-based buffer overflow vulnerabilities have been identified, which may allow remote code execution.CVE-2018-17911 has been assigned to these vulnerabilities. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-17911" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "LCDS recommends that users update to Version 4.1.0.4114, which can be found at the following location:", "product_ids": [ "CSAFPID-0001" ], "url": "http://laquisscada.com/instale1.php" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
icsa-18-289-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Mat Powell", "Ashraf Alharbi (Ha5ha5hin)" ], "organization": "Trend Micro \u0027s Zero Day Initiative", "summary": "reporting these vulnerabilities to NCCIC" }, { "names": [ "rgod" ], "organization": "9SG Security Team", "summary": "reporting these vulnerabilities to NCCIC" }, { "names": [ "Esteban Ruiz (mr_me)" ], "organization": "Source Incite", "summary": "reporting these vulnerabilities to NCCIC" }, { "names": [ "b0nd @garage4hackers" ], "summary": "reporting these vulnerabilities to NCCIC" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code, crash the system, or write controlled content to the target system.", "title": "Risk evaluation" }, { "category": "other", "text": "Chemical, Commercial Facilities, Energy, Food and Agriculture, Transportation Systems, Water and Wastewater Systems", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "South America", "title": "Countries/areas deployed" }, { "category": "other", "text": "Brazil", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-18-289-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2018/icsa-18-289-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-18-289-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-18-289-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas Ltda ME LAquis SCADA", "tracking": { "current_release_date": "2018-10-16T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-18-289-01", "initial_release_date": "2018-10-16T00:00:00.000000Z", "revision_history": [ { "date": "2018-10-16T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-18-289-01 LCDS - Leao Consultoria e Desenvolvimento de Sistemas LTDA ME LAquis SCADA" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c= 4.1.0.3870", "product": { "name": "Smart Security Manager: Versions 4.1.0.3870 and prior", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Smart Security Manager" } ], "category": "vendor", "name": "LCDS - Le\u00c3\u00a3o Consultoria e Desenvolvimento de Sistemas LTDA ME" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-17893", "cwe": { "id": "CWE-822", "name": "Untrusted Pointer Dereference" }, "notes": [ { "category": "summary", "text": "An untrusted pointer dereference vulnerability has been identified, which may allow remote code execution.CVE-2018-17893 has been assigned to this vulnerability. A CVSS v3 base score of 5.6 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-17893" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L" } ], "remediations": [ { "category": "mitigation", "details": "LCDS recommends that users update to Version 4.1.0.4114, which can be found at the following location:", "product_ids": [ "CSAFPID-0001" ], "url": "http://laquisscada.com/instale1.php" } ], "scores": [ { "cvss_v3": { "baseScore": 5.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-17895", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Several out-of-bounds read vulnerabilities have been identified, which may allow remote code execution.CVE-2018-17895 has been assigned to these vulnerabilities. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-17895" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L" } ], "remediations": [ { "category": "mitigation", "details": "LCDS recommends that users update to Version 4.1.0.4114, which can be found at the following location:", "product_ids": [ "CSAFPID-0001" ], "url": "http://laquisscada.com/instale1.php" } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-17897", "cwe": { "id": "CWE-680", "name": "Integer Overflow to Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Several integer overflow to buffer overflow vulnerabilities have been identified, which may allow remote code execution.CVE-2018-17897 has been assigned to these vulnerabilities. A CVSS v3 base score of 5.6 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-17897" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L" } ], "remediations": [ { "category": "mitigation", "details": "LCDS recommends that users update to Version 4.1.0.4114, which can be found at the following location:", "product_ids": [ "CSAFPID-0001" ], "url": "http://laquisscada.com/instale1.php" } ], "scores": [ { "cvss_v3": { "baseScore": 5.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-17899", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "summary", "text": "A path traversal vulnerability has been identified, which may allow remote code execution.CVE-2018-17899 has been assigned to this vulnerability. A CVSS v3 base score of 6.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-17899" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L" } ], "remediations": [ { "category": "mitigation", "details": "LCDS recommends that users update to Version 4.1.0.4114, which can be found at the following location:", "product_ids": [ "CSAFPID-0001" ], "url": "http://laquisscada.com/instale1.php" } ], "scores": [ { "cvss_v3": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-17901", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "When processing project files the application fails to sanitize user input prior to performing write operations on a stack object, which may allow an attacker to execute code under the current process.CVE-2018-17901 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-17901" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L" } ], "remediations": [ { "category": "mitigation", "details": "LCDS recommends that users update to Version 4.1.0.4114, which can be found at the following location:", "product_ids": [ "CSAFPID-0001" ], "url": "http://laquisscada.com/instale1.php" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-17911", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Several stack-based buffer overflow vulnerabilities have been identified, which may allow remote code execution.CVE-2018-17911 has been assigned to these vulnerabilities. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-17911" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "LCDS recommends that users update to Version 4.1.0.4114, which can be found at the following location:", "product_ids": [ "CSAFPID-0001" ], "url": "http://laquisscada.com/instale1.php" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
fkie_cve-2018-17899
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://laquisscada.com/instale1.php | Product, Vendor Advisory | |
ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/105719 | Third Party Advisory, VDB Entry | |
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01 | Third Party Advisory, US Government Resource | |
nvd@nist.gov | https://exchange.xforce.ibmcloud.com/vulnerabilities/151420 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://laquisscada.com/instale1.php | Product, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/105719 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01 | Third Party Advisory, US Government Resource |
Vendor | Product | Version | |
---|---|---|---|
lcds | laquis_scada | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*", "matchCriteriaId": "B5F605D9-73FC-4D5B-9884-50512081BF6F", "versionEndIncluding": "4.1.0.3870", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "LAquis SCADA Versions 4.1.0.3870 and prior has a path traversal vulnerability, which may allow remote code execution." }, { "lang": "es", "value": "LAquis SCADA en versiones 4.1.0.3870 y anteriores tiene una vulnerabilidad de salto de directorio que podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo." } ], "id": "CVE-2018-17899", "lastModified": "2024-11-21T03:55:10.040", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-17T02:29:01.000", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Product", "Vendor Advisory" ], "url": "http://laquisscada.com/instale1.php" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/105719" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01" }, { "source": "nvd@nist.gov", "tags": [ "Third Party Advisory" ], "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/151420" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Product", "Vendor Advisory" ], "url": "http://laquisscada.com/instale1.php" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/105719" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
gsd-2018-17899
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2018-17899", "description": "LAquis SCADA Versions 4.1.0.3870 and prior has a path traversal vulnerability, which may allow remote code execution.", "id": "GSD-2018-17899" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2018-17899" ], "details": "LAquis SCADA Versions 4.1.0.3870 and prior has a path traversal vulnerability, which may allow remote code execution.", "id": "GSD-2018-17899", "modified": "2023-12-13T01:22:31.344118Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2018-10-16T00:00:00", "ID": "CVE-2018-17899", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "LAquis SCADA", "version": { "version_data": [ { "version_value": "4.1.0.3870 and prior" } ] } } ] }, "vendor_name": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas LTDA ME" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "LAquis SCADA Versions 4.1.0.3870 and prior has a path traversal vulnerability, which may allow remote code execution." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "PATH TRAVERSAL CWE-22" } ] } ] }, "references": { "reference_data": [ { "name": "http://laquisscada.com/instale1.php", "refsource": "MISC", "url": "http://laquisscada.com/instale1.php" }, { "name": "105719", "refsource": "BID", "url": "http://www.securityfocus.com/bid/105719" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "4.1.0.3870", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2018-17899" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "LAquis SCADA Versions 4.1.0.3870 and prior has a path traversal vulnerability, which may allow remote code execution." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-22" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01", "refsource": "MISC", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01" }, { "name": "http://laquisscada.com/instale1.php", "refsource": "MISC", "tags": [ "Product", "Vendor Advisory" ], "url": "http://laquisscada.com/instale1.php" }, { "name": "105719", "refsource": "BID", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/105719" }, { "name": "https://exchange.xforce.ibmcloud.com/vulnerabilities/151420", "refsource": "MISC", "tags": [ "Third Party Advisory" ], "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/151420" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": true }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9 } }, "lastModifiedDate": "2019-10-09T23:37Z", "publishedDate": "2018-10-17T02:29Z" } } }
ghsa-fqm8-4qp5-8qr2
Vulnerability from github
LAquis SCADA Versions 4.1.0.3870 and prior has a path traversal vulnerability, which may allow remote code execution.
{ "affected": [], "aliases": [ "CVE-2018-17899" ], "database_specific": { "cwe_ids": [ "CWE-22" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2018-10-17T02:29:00Z", "severity": "HIGH" }, "details": "LAquis SCADA Versions 4.1.0.3870 and prior has a path traversal vulnerability, which may allow remote code execution.", "id": "GHSA-fqm8-4qp5-8qr2", "modified": "2022-05-13T01:33:47Z", "published": "2022-05-13T01:33:47Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2018-17899" }, { "type": "WEB", "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/151420" }, { "type": "WEB", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01" }, { "type": "WEB", "url": "http://laquisscada.com/instale1.php" }, { "type": "WEB", "url": "http://www.securityfocus.com/bid/105719" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.