CVE-2017-7575 (GCVE-0-2017-7575)
Vulnerability from cvelistv5
Published
2017-04-06 21:00
Modified
2024-08-05 16:04
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Schneider Electric Modicon TM221CE16R 1.3.3.3 devices allow remote attackers to discover the application-protection password via a \x00\x01\x00\x00\x00\x05\x01\x5a\x00\x03\x00 request to the Modbus port (502/tcp). Subsequently the application may be arbitrarily downloaded, modified, and uploaded.
References
| URL | Tags | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:04:12.098Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-02"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://os-s.net/advisories/OSS-2017-01.pdf"
},
{
"name": "97523",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/97523"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2017-04-06T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Schneider Electric Modicon TM221CE16R 1.3.3.3 devices allow remote attackers to discover the application-protection password via a \\x00\\x01\\x00\\x00\\x00\\x05\\x01\\x5a\\x00\\x03\\x00 request to the Modbus port (502/tcp). Subsequently the application may be arbitrarily downloaded, modified, and uploaded."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-04-14T04:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-02"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://os-s.net/advisories/OSS-2017-01.pdf"
},
{
"name": "97523",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/97523"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-7575",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Schneider Electric Modicon TM221CE16R 1.3.3.3 devices allow remote attackers to discover the application-protection password via a \\x00\\x01\\x00\\x00\\x00\\x05\\x01\\x5a\\x00\\x03\\x00 request to the Modbus port (502/tcp). Subsequently the application may be arbitrarily downloaded, modified, and uploaded."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-02",
"refsource": "CONFIRM",
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-02"
},
{
"name": "https://os-s.net/advisories/OSS-2017-01.pdf",
"refsource": "MISC",
"url": "https://os-s.net/advisories/OSS-2017-01.pdf"
},
{
"name": "97523",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/97523"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2017-7575",
"datePublished": "2017-04-06T21:00:00",
"dateReserved": "2017-04-06T00:00:00",
"dateUpdated": "2024-08-05T16:04:12.098Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2017-7575\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2017-04-06T21:59:00.337\",\"lastModified\":\"2025-04-20T01:37:25.860\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Schneider Electric Modicon TM221CE16R 1.3.3.3 devices allow remote attackers to discover the application-protection password via a \\\\x00\\\\x01\\\\x00\\\\x00\\\\x00\\\\x05\\\\x01\\\\x5a\\\\x00\\\\x03\\\\x00 request to the Modbus port (502/tcp). Subsequently the application may be arbitrarily downloaded, modified, and uploaded.\"},{\"lang\":\"es\",\"value\":\"Los dispositivos Schneider Electric Modicon TM221CE16R 1.3.3.3 permiten a atacantes remotos descubrir la contrase\u00f1a de protecci\u00f3n de la aplicaci\u00f3n a trav\u00e9s de una solicitud \\\\x00\\\\x01\\\\x00\\\\x00\\\\x00\\\\x05\\\\x01\\\\x5a\\\\x00\\\\x03\\\\x00 al puerto Modbus (502/tcp). Posteriormente la aplicaci\u00f3n puede descargarse, modificarse y cargarse arbitrariamente.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_tm221ce16r_firmware:1.3.3.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"26C40BAF-2C91-4069-A62E-1B1E60BA1619\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_tm221ce16r:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"00715571-AC4B-4B1F-8E65-385B56F2004C\"}]}]}],\"references\":[{\"url\":\"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-02\",\"source\":\"cve@mitre.org\"},{\"url\":\"http://www.securityfocus.com/bid/97523\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://os-s.net/advisories/OSS-2017-01.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.securityfocus.com/bid/97523\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://os-s.net/advisories/OSS-2017-01.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…