Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2011-4876 (GCVE-0-2011-4876)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-07T00:16:35.056Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "46997", "tags": [ "third-party-advisory", "x_refsource_SECUNIA", "x_transferred" ], "url": "http://secunia.com/advisories/46997" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "name": "18166", "tags": [ "exploit", "x_refsource_EXPLOIT-DB", "x_transferred" ], "url": "http://www.exploit-db.com/exploits/18166" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://aluigi.org/adv/winccflex_1-adv.txt" }, { "name": "simatic-hmiload-dir-traversal(71450)", "tags": [ "vdb-entry", "x_refsource_XF", "x_transferred" ], "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71450" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf" }, { "name": "77381", "tags": [ "vdb-entry", "x_refsource_OSVDB", "x_transferred" ], "url": "http://www.osvdb.org/77381" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2011-12-02T00:00:00", "descriptions": [ { "lang": "en", "value": "Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2017-08-28T12:57:01", "orgId": "37e5125f-f79b-445b-8fad-9564f167944b", "shortName": "certcc" }, "references": [ { "name": "46997", "tags": [ "third-party-advisory", "x_refsource_SECUNIA" ], "url": "http://secunia.com/advisories/46997" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "name": "18166", "tags": [ "exploit", "x_refsource_EXPLOIT-DB" ], "url": "http://www.exploit-db.com/exploits/18166" }, { "tags": [ "x_refsource_MISC" ], "url": "http://aluigi.org/adv/winccflex_1-adv.txt" }, { "name": "simatic-hmiload-dir-traversal(71450)", "tags": [ "vdb-entry", "x_refsource_XF" ], "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71450" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf" }, { "name": "77381", "tags": [ "vdb-entry", "x_refsource_OSVDB" ], "url": "http://www.osvdb.org/77381" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cert@cert.org", "ID": "CVE-2011-4876", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "46997", "refsource": "SECUNIA", "url": "http://secunia.com/advisories/46997" }, { "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf", "refsource": "MISC", "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf" }, { "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf", "refsource": "MISC", "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf" }, { "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf", "refsource": "CONFIRM", "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "name": "18166", "refsource": "EXPLOIT-DB", "url": "http://www.exploit-db.com/exploits/18166" }, { "name": "http://aluigi.org/adv/winccflex_1-adv.txt", "refsource": "MISC", "url": "http://aluigi.org/adv/winccflex_1-adv.txt" }, { "name": "simatic-hmiload-dir-traversal(71450)", "refsource": "XF", "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71450" }, { "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf", "refsource": "MISC", "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf" }, { "name": "77381", "refsource": "OSVDB", "url": "http://www.osvdb.org/77381" } ] } } } }, "cveMetadata": { "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b", "assignerShortName": "certcc", "cveId": "CVE-2011-4876", "datePublished": "2012-02-03T20:00:00", "dateReserved": "2011-12-21T00:00:00", "dateUpdated": "2024-08-07T00:16:35.056Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2011-4876\",\"sourceIdentifier\":\"cret@cert.org\",\"published\":\"2012-02-03T20:55:01.937\",\"lastModified\":\"2025-04-11T00:51:21.963\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string.\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad de salto de directorio en HmiLoad del cargador de tiempo de ejecuci\u00f3n (\\\"runtime loader\\\") de Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; y WinCC flexible Runtime, si el modo de transferencia (\\\"Transfer Mode\\\") est\u00e1 habilitado, permite a atacantes remotos ejecutar, leer, crear, modificar o borrar archivos arbitrarios a trav\u00e9s de los caracteres .. (punto punto) en una cadena.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:C/I:C/A:C\",\"baseScore\":9.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.6,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-22\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc_flexible:2004:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7D596C29-36F8-44F2-897D-FD107769E5A9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc_flexible:2005:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2D84E29A-4BC2-4229-83C3-D9F7A641D19C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc_flexible:2007:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9B3ADDE1-1F91-43E7-A3C3-3069916F4B23\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc_flexible:2008:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1432EC7A-47B2-41D1-B90B-72DBB79AC266\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:v11:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"18A9883B-80E1-4B2E-88DA-D2326AE3DC08\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_hmi_panels:comfort_panels:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DC593746-B329-43EA-8CA1-AA56AC5A3B10\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_hmi_panels:mobile_panels:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1DF877E8-A0D1-4444-99F2-8A3E8ED4D31B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_hmi_panels:mp:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"442AC914-BDD5-4D0C-9E04-88F60EE2B730\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_hmi_panels:op:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D9749966-1666-4F7D-90D0-17AFBB88AE83\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_hmi_panels:tp:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9471D239-08B1-4076-82F7-2B73F4E343CE\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc_runtime_advanced:v11:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1AE3AE80-C7A2-4581-993A-536936F6D315\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc_flexible_runtime:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6F785262-BBFB-4A0C-A7DC-97F5D6B94BB0\"}]}]}],\"references\":[{\"url\":\"http://aluigi.org/adv/winccflex_1-adv.txt\",\"source\":\"cret@cert.org\"},{\"url\":\"http://secunia.com/advisories/46997\",\"source\":\"cret@cert.org\"},{\"url\":\"http://www.exploit-db.com/exploits/18166\",\"source\":\"cret@cert.org\"},{\"url\":\"http://www.osvdb.org/77381\",\"source\":\"cret@cert.org\"},{\"url\":\"http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf\",\"source\":\"cret@cert.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf\",\"source\":\"cret@cert.org\"},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf\",\"source\":\"cret@cert.org\"},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf\",\"source\":\"cret@cert.org\",\"tags\":[\"US Government Resource\"]},{\"url\":\"https://exchange.xforce.ibmcloud.com/vulnerabilities/71450\",\"source\":\"cret@cert.org\"},{\"url\":\"http://aluigi.org/adv/winccflex_1-adv.txt\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://secunia.com/advisories/46997\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.exploit-db.com/exploits/18166\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.osvdb.org/77381\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"US Government Resource\"]},{\"url\":\"https://exchange.xforce.ibmcloud.com/vulnerabilities/71450\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}" } }
var-201202-0163
Vulnerability from variot
Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string. plural Siemens Product runtime loader HmiLoad Is Transfer A directory traversal vulnerability exists when the mode is enabled.By a third party .. ( Dot dot ) Arbitrary files may be executed, read, created, modified, or deleted via strings containing. Miniweb has a security vulnerability that allows an attacker to submit a specially crafted HTTP POST request to allow the server to access any illegal memory area while checking the extension of the requested file. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. HmiLoad provides functions that read data and unicode strings with stack-based buffer overflows, allowing an attacker to exploit a vulnerability to execute arbitrary code. HmiLoad has multiple security vulnerabilities that allow an attacker to stop a service or crash a service in multiple ways. A directory traversal vulnerability exists in the HmiLoad server that allows reading, writing, and deleting arbitrary files outside of the specified directory. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. When the transfer mode is enabled, the runtime loader listens on the 2308/TCP or 50523/TCP port, but does not verify the submitted string, allowing the attacker to read and write any file in the file system. Attackers can exploit these issues to execute arbitrary code in the context of the affected application, read/write or delete arbitrary files outside of the server root directory, or cause denial-of-service conditions; other attacks may also be possible. (dots) in strings. ----------------------------------------------------------------------
Secunia is hiring!
Find your next job here:
http://secunia.com/company/jobs/
TITLE: Siemens SIMATIC WinCC Flexible HMI Miniweb Two Vulnerabilities
SECUNIA ADVISORY ID: SA46997
VERIFY ADVISORY: Secunia.com http://secunia.com/advisories/46997/ Customer Area (Credentials Required) https://ca.secunia.com/?page=viewadvisory&vuln_id=46997
RELEASE DATE: 2011-11-30
DISCUSS ADVISORY: http://secunia.com/advisories/46997/#comments
AVAILABLE ON SITE AND IN CUSTOMER AREA: * Last Update * Popularity * Comments * Criticality Level * Impact * Where * Solution Status * Operating System / Software * CVE Reference(s)
http://secunia.com/advisories/46997/
ONLY AVAILABLE IN CUSTOMER AREA: * Authentication Level * Report Reliability * Secunia PoC * Secunia Analysis * Systems Affected * Approve Distribution * Remediation Status * Secunia CVSS Score * CVSS
https://ca.secunia.com/?page=viewadvisory&vuln_id=46997
ONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI: * AUTOMATED SCANNING
http://secunia.com/vulnerability_scanning/personal/ http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/
DESCRIPTION: Luigi Auriemma has discovered two vulnerabilities in Siemens SIMATIC WinCC Flexible, which can be exploited by malicious people to disclose potentially sensitive information and cause a DoS (Denial of Service).
1) An input sanitisation error in Miniweb.exe when handling HTTP GET requests can be exploited to download arbitrary files via directory traversal attacks sent in a web request.
2) An input validation error in Miniweb.exe when handling HTTP POST requests can be exploited to crash the process via specially crafted content sent in a web request.
The vulnerabilities are confirmed in version 2008 SP2 Upd13 (K01.03.02.13_01.02.00.01). Other versions may also be affected.
SOLUTION: Restrict access to trusted hosts only.
PROVIDED AND/OR DISCOVERED BY: Luigi Auriemma
ORIGINAL ADVISORY: http://aluigi.altervista.org/adv/winccflex_1-adv.txt
OTHER REFERENCES: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
DEEP LINKS: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED DESCRIPTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED SOLUTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXPLOIT: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities.
Subscribe: http://secunia.com/advisories/secunia_security_advisories/
Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/
Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.
Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org
Show details on source website
{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0163", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc flexible runtime", "scope": null, "trust": 3.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc flexible sp2", "scope": "eq", "trust": 3.3, "vendor": "siemens", "version": "2008" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "mp" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "op" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 2.4, "vendor": "siemens", "version": "tp" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2007" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2005" }, { "model": "simatic wincc flexible", "scope": "eq", "trust": 1.7, "vendor": "siemens", "version": "2004" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "2008" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "comfort_panels" }, { "model": "wincc runtime advanced", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "wincc", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "v11" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "mobile_panels" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "2007" }, { "model": "simatic wincc", "scope": "eq", "trust": 1.4, "vendor": "siemens", "version": "v11" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2004" }, { "model": "wincc flexible runtime", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "wincc flexible", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2005" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "comfort panels" }, { "model": "simatic hmi panels", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "mobile panels" }, { "model": "simatic wincc flexible rumtime", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "v11" }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic hmi panels", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "wincc flexible runtime", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc flexible runtime", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic wincc flexible sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2008" }, { "model": "simatic wincc flexible sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2005" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2004" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2005" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2007" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible", "version": "2008" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc", "version": "v11" }, { "model": "comfort panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mobile panels", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "mp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "op", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": "tp", "scope": null, "trust": 0.2, "vendor": "simatic hmi panels", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc runtime advanced", "version": "v11" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc flexible runtime", "version": "*" } ], "sources": [ { "db": "IVD", "id": "28b71d12-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "CNVD", "id": "CNVD-2012-0466" }, { "db": "BID", "id": "50828" }, { "db": "JVNDB", "id": "JVNDB-2012-001318" }, { "db": "CNNVD", "id": "CNNVD-201202-091" }, { "db": "NVD", "id": "CVE-2011-4876" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001318" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Luigi Auriemma", "sources": [ { "db": "BID", "id": "50828" }, { "db": "CNNVD", "id": "CNNVD-201111-480" } ], "trust": 0.9 }, "cve": "CVE-2011-4876", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "CVE-2011-4876", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "28b71d12-2354-11e6-abef-000c29c66e3d", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "VHN-52821", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2011-4876", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2011-4876", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-201202-091", "trust": 0.6, "value": "CRITICAL" }, { "author": "IVD", "id": "28b71d12-2354-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "CRITICAL" }, { "author": "VULHUB", "id": "VHN-52821", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "28b71d12-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52821" }, { "db": "JVNDB", "id": "JVNDB-2012-001318" }, { "db": "CNNVD", "id": "CNNVD-201202-091" }, { "db": "NVD", "id": "CVE-2011-4876" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string. plural Siemens Product runtime loader HmiLoad Is Transfer A directory traversal vulnerability exists when the mode is enabled.By a third party .. ( Dot dot ) Arbitrary files may be executed, read, created, modified, or deleted via strings containing. Miniweb has a security vulnerability that allows an attacker to submit a specially crafted HTTP POST request to allow the server to access any illegal memory area while checking the extension of the requested file. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. HmiLoad provides functions that read data and unicode strings with stack-based buffer overflows, allowing an attacker to exploit a vulnerability to execute arbitrary code. HmiLoad has multiple security vulnerabilities that allow an attacker to stop a service or crash a service in multiple ways. A directory traversal vulnerability exists in the HmiLoad server that allows reading, writing, and deleting arbitrary files outside of the specified directory. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. When the transfer mode is enabled, the runtime loader listens on the 2308/TCP or 50523/TCP port, but does not verify the submitted string, allowing the attacker to read and write any file in the file system. \nAttackers can exploit these issues to execute arbitrary code in the context of the affected application, read/write or delete arbitrary files outside of the server root directory, or cause denial-of-service conditions; other attacks may also be possible. (dots) in strings. ----------------------------------------------------------------------\n\nSecunia is hiring!\n\nFind your next job here:\n\nhttp://secunia.com/company/jobs/\n\n----------------------------------------------------------------------\n\nTITLE:\nSiemens SIMATIC WinCC Flexible HMI Miniweb Two Vulnerabilities\n\nSECUNIA ADVISORY ID:\nSA46997\n\nVERIFY ADVISORY:\nSecunia.com\nhttp://secunia.com/advisories/46997/\nCustomer Area (Credentials Required)\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=46997\n\nRELEASE DATE:\n2011-11-30\n\nDISCUSS ADVISORY:\nhttp://secunia.com/advisories/46997/#comments\n\nAVAILABLE ON SITE AND IN CUSTOMER AREA:\n * Last Update\n * Popularity\n * Comments\n * Criticality Level\n * Impact\n * Where\n * Solution Status\n * Operating System / Software\n * CVE Reference(s)\n\nhttp://secunia.com/advisories/46997/\n\nONLY AVAILABLE IN CUSTOMER AREA:\n * Authentication Level\n * Report Reliability\n * Secunia PoC\n * Secunia Analysis\n * Systems Affected\n * Approve Distribution\n * Remediation Status\n * Secunia CVSS Score\n * CVSS\n\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=46997\n\nONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI:\n * AUTOMATED SCANNING\n\nhttp://secunia.com/vulnerability_scanning/personal/\nhttp://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/\n\nDESCRIPTION:\nLuigi Auriemma has discovered two vulnerabilities in Siemens SIMATIC\nWinCC Flexible, which can be exploited by malicious people to\ndisclose potentially sensitive information and cause a DoS (Denial of\nService). \n\n1) An input sanitisation error in Miniweb.exe when handling HTTP GET\nrequests can be exploited to download arbitrary files via directory\ntraversal attacks sent in a web request. \n\n2) An input validation error in Miniweb.exe when handling HTTP POST\nrequests can be exploited to crash the process via specially crafted\ncontent sent in a web request. \n\nThe vulnerabilities are confirmed in version 2008 SP2 Upd13\n(K01.03.02.13_01.02.00.01). Other versions may also be affected. \n\nSOLUTION:\nRestrict access to trusted hosts only. \n\nPROVIDED AND/OR DISCOVERED BY:\nLuigi Auriemma\n\nORIGINAL ADVISORY:\nhttp://aluigi.altervista.org/adv/winccflex_1-adv.txt\n\nOTHER REFERENCES:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nDEEP LINKS:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED DESCRIPTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED SOLUTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXPLOIT:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\nprivate users keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n", "sources": [ { "db": "NVD", "id": "CVE-2011-4876" }, { "db": "JVNDB", "id": "JVNDB-2012-001318" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "CNVD", "id": "CNVD-2012-0466" }, { "db": "BID", "id": "50828" }, { "db": "IVD", "id": "28b71d12-2354-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-52821" }, { "db": "PACKETSTORM", "id": "107419" } ], "trust": 5.49 }, "exploit_availability": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "reference": "https://www.scap.org.cn/vuln/vhn-52821", "trust": 0.1, "type": "unknown" } ], "sources": [ { "db": "VULHUB", "id": "VHN-52821" } ] }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "BID", "id": "50828", "trust": 3.9 }, { "db": "NVD", "id": "CVE-2011-4876", "trust": 3.6 }, { "db": "ICS CERT", "id": "ICSA-12-030-01", "trust": 3.4 }, { "db": "SIEMENS", "id": "SSA-345442", "trust": 1.7 }, { "db": "SECUNIA", "id": "46997", "trust": 1.2 }, { "db": "ICS CERT ALERT", "id": "ICS-ALERT-11-332-02A", "trust": 1.1 }, { "db": "ICS CERT ALERT", "id": "ICS-ALERT-11-332-02", "trust": 1.1 }, { "db": "OSVDB", "id": "77381", "trust": 1.1 }, { "db": "EXPLOIT-DB", "id": "18166", "trust": 1.1 }, { "db": "CNNVD", "id": "CNNVD-201202-091", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2012-0466", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2012-001318", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2011-5108", "trust": 0.6 }, { "db": "CNVD", "id": "CNVD-2011-5110", "trust": 0.6 }, { "db": "CNVD", "id": "CNVD-2011-5103", "trust": 0.6 }, { "db": "CNVD", "id": "CNVD-2011-5107", "trust": 0.6 }, { "db": "CNVD", "id": "CNVD-2011-5105", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-201111-480", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-12-030-01A", "trust": 0.3 }, { "db": "IVD", "id": "28B71D12-2354-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-52821", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "107419", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "28b71d12-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "CNVD", "id": "CNVD-2012-0466" }, { "db": "VULHUB", "id": "VHN-52821" }, { "db": "BID", "id": "50828" }, { "db": "JVNDB", "id": "JVNDB-2012-001318" }, { "db": "PACKETSTORM", "id": "107419" }, { "db": "CNNVD", "id": "CNNVD-201111-480" }, { "db": "CNNVD", "id": "CNNVD-201202-091" }, { "db": "NVD", "id": "CVE-2011-4876" } ] }, "id": "VAR-201202-0163", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "28b71d12-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "CNVD", "id": "CNVD-2012-0466" }, { "db": "VULHUB", "id": "VHN-52821" } ], "trust": 4.568457485714285 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 3.8 } ], "sources": [ { "db": "IVD", "id": "28b71d12-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "CNVD", "id": "CNVD-2012-0466" } ] }, "last_update_date": "2024-11-23T21:46:29.307000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-345442", "trust": 0.8, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc", "trust": 0.8, "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx" }, { "title": "Top Page", "trust": 0.8, "url": "http://www.siemens.com/entry/jp/ja/" }, { "title": "Patch for Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 file download vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/72694" }, { "title": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 memory access vulnerability patch", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/72697" }, { "title": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 Buffer Overflow Vulnerability Patch", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/72705" }, { "title": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 service crash vulnerability patch", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/72689" }, { "title": "Patch for Siemens SIMATIC WinCC HMI Directory Traversal Vulnerability (CNVD-2012-0466)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/9072" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2012-0466" }, { "db": "JVNDB", "id": "JVNDB-2012-001318" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-22", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-52821" }, { "db": "JVNDB", "id": "JVNDB-2012-001318" }, { "db": "NVD", "id": "CVE-2011-4876" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 4.0, "url": "http://aluigi.altervista.org/adv/winccflex_1-adv.txt" }, { "trust": 3.4, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf" }, { "trust": 1.7, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "trust": 1.1, "url": "http://www.exploit-db.com/exploits/18166" }, { "trust": 1.1, "url": "http://aluigi.org/adv/winccflex_1-adv.txt" }, { "trust": 1.1, "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-11-332-02.pdf" }, { "trust": 1.1, "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-11-332-02a.pdf" }, { "trust": 1.1, "url": "http://www.osvdb.org/77381" }, { "trust": 1.1, "url": "http://secunia.com/advisories/46997" }, { "trust": 1.1, "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71450" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4876" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4876" }, { "trust": 0.6, "url": "http://www.securityfocus.com/bid/50828" }, { "trust": 0.3, "url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/pages/default.aspx" }, { "trust": 0.3, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01a.pdf" }, { "trust": 0.1, "url": "http://secunia.com/company/jobs/" }, { "trust": 0.1, "url": "http://secunia.com/vulnerability_intelligence/" }, { "trust": 0.1, "url": "http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/" }, { "trust": 0.1, "url": "http://secunia.com/advisories/secunia_security_advisories/" }, { "trust": 0.1, "url": "http://secunia.com/vulnerability_scanning/personal/" }, { "trust": 0.1, "url": "http://secunia.com/advisories/46997/" }, { "trust": 0.1, "url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org" }, { "trust": 0.1, "url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=46997" }, { "trust": 0.1, "url": "http://secunia.com/advisories/46997/#comments" }, { "trust": 0.1, "url": "http://secunia.com/advisories/about_secunia_advisories/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "CNVD", "id": "CNVD-2012-0466" }, { "db": "VULHUB", "id": "VHN-52821" }, { "db": "BID", "id": "50828" }, { "db": "JVNDB", "id": "JVNDB-2012-001318" }, { "db": "PACKETSTORM", "id": "107419" }, { "db": "CNNVD", "id": "CNNVD-201111-480" }, { "db": "CNNVD", "id": "CNNVD-201202-091" }, { "db": "NVD", "id": "CVE-2011-4876" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "28b71d12-2354-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2011-5108" }, { "db": "CNVD", "id": "CNVD-2011-5110" }, { "db": "CNVD", "id": "CNVD-2011-5103" }, { "db": "CNVD", "id": "CNVD-2011-5107" }, { "db": "CNVD", "id": "CNVD-2011-5105" }, { "db": "CNVD", "id": "CNVD-2012-0466" }, { "db": "VULHUB", "id": "VHN-52821" }, { "db": "BID", "id": "50828" }, { "db": "JVNDB", "id": "JVNDB-2012-001318" }, { "db": "PACKETSTORM", "id": "107419" }, { "db": "CNNVD", "id": "CNNVD-201111-480" }, { "db": "CNNVD", "id": "CNNVD-201202-091" }, { "db": "NVD", "id": "CVE-2011-4876" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2012-02-07T00:00:00", "db": "IVD", "id": "28b71d12-2354-11e6-abef-000c29c66e3d" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5108" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5110" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5103" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5107" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5105" }, { "date": "2012-02-07T00:00:00", "db": "CNVD", "id": "CNVD-2012-0466" }, { "date": "2012-02-03T00:00:00", "db": "VULHUB", "id": "VHN-52821" }, { "date": "2011-11-28T00:00:00", "db": "BID", "id": "50828" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001318" }, { "date": "2011-11-30T03:40:12", "db": "PACKETSTORM", "id": "107419" }, { "date": "1900-01-01T00:00:00", "db": "CNNVD", "id": "CNNVD-201111-480" }, { "date": "2012-02-07T00:00:00", "db": "CNNVD", "id": "CNNVD-201202-091" }, { "date": "2012-02-03T20:55:01.937000", "db": "NVD", "id": "CVE-2011-4876" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2016-03-15T00:00:00", "db": "CNVD", "id": "CNVD-2011-5108" }, { "date": "2016-03-15T00:00:00", "db": "CNVD", "id": "CNVD-2011-5110" }, { "date": "2016-03-15T00:00:00", "db": "CNVD", "id": "CNVD-2011-5103" }, { "date": "2016-03-15T00:00:00", "db": "CNVD", "id": "CNVD-2011-5107" }, { "date": "2011-12-05T00:00:00", "db": "CNVD", "id": "CNVD-2011-5105" }, { "date": "2012-02-07T00:00:00", "db": "CNVD", "id": "CNVD-2012-0466" }, { "date": "2017-08-29T00:00:00", "db": "VULHUB", "id": "VHN-52821" }, { "date": "2012-04-18T21:20:00", "db": "BID", "id": "50828" }, { "date": "2012-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-001318" }, { "date": "2011-11-30T00:00:00", "db": "CNNVD", "id": "CNNVD-201111-480" }, { "date": "2012-02-07T00:00:00", "db": "CNNVD", "id": "CNNVD-201202-091" }, { "date": "2024-11-21T01:33:10.577000", "db": "NVD", "id": "CVE-2011-4876" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201111-480" }, { "db": "CNNVD", "id": "CNNVD-201202-091" } ], "trust": 1.2 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Siemens Product HmiLoad Vulnerable to directory traversal", "sources": [ { "db": "JVNDB", "id": "JVNDB-2012-001318" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Path traversal", "sources": [ { "db": "IVD", "id": "28b71d12-2354-11e6-abef-000c29c66e3d" }, { "db": "CNNVD", "id": "CNNVD-201202-091" } ], "trust": 0.8 } }
icsa-12-030-01a
Vulnerability from csaf_cisa
Notes
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.", "title": "Recommended Practices" } ], "publisher": { "category": "coordinator", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-12-030-01A JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2012/icsa-12-030-01a.json" }, { "category": "self", "summary": "ICS Advisory ICSA-12-030-01A - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-12-030-01a" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014" } ], "title": "Siemens SIMATIC WinCC Vulnerabilities", "tracking": { "current_release_date": "2025-06-09T16:35:39.943110Z", "generator": { "date": "2025-06-09T16:35:39.942994Z", "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-12-030-01A", "initial_release_date": "2012-11-02T06:00:00.000000Z", "revision_history": [ { "date": "2012-11-02T06:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Initial Publication" }, { "date": "2025-06-09T16:35:39.943110Z", "legacy_version": "CSAF Conversion", "number": "2", "summary": "Advisory converted into a CSAF" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "2004|2005|2007|2008", "product": { "name": "Siemens WinCC flexible: 2004|2005|2007|2008", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "WinCC flexible" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Siemens WinCC V11 (TIA portal): vers:all/*", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "WinCC V11 (TIA portal)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Siemens Multiple SIMATIC HMI panels (TP, OP, MP, Comfort Panels, Mobile Panels): vers:all/*", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Multiple SIMATIC HMI panels (TP, OP, MP, Comfort Panels, Mobile Panels)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Siemens WinCC V11 Runtime Advanced: vers:all/*", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "WinCC V11 Runtime Advanced" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Siemens WinCC flexible Runtime: vers:all/*", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "WinCC flexible Runtime" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2011-4508", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "remediations": [ { "category": "mitigation", "details": "Each of the reported vulnerabilities has been addressed by Siemens, as follows: Insecure authentication token generation, cross-site scripting, header injection vulnerability, HMI web server directory traversal, and arbitrary memory read access vulnerabilities - Patches are included in Siemens\u2019 WinCC V11 (TIA Portal) SP2 Update 1WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112582)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112582" }, { "category": "mitigation", "details": "WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112587)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112587" }, { "category": "mitigation", "details": "and WinCC flexible 2008 SP3.WinCC flexible 2008 SP3, (http://support.automation.siemens.com/WW/view/en/57267466).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/57267466" }, { "category": "mitigation", "details": "Weak default passwords - Product documentation contained in WinCC V11 (TIA Portal) SP2 Update 1, and WinCC flexible 2008 SP3 has been updated to tell the user how to set a proper password during initial setup.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Client-side attack via specially crafted files, runtime loader string stack overflow, runtime loader directory traversal, runtime loader DoS - Siemens recommends that users deactivate the transfer mode after device configuration, because the transport mode provides full access to the device. The transport mode was implemented under the assumption that the software would be running in a protected industrial environment. Siemens strongly recommends that users protect systems according to recommended security practicesSiemens Operational Guidelines for Industrial Security, v1.1, (http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf" }, { "category": "mitigation", "details": "Siemens Industrial Security homepage, (http://www.siemens.com/industrialsecurity). and configure the environment according to the operational guidelines.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.siemens.com/industrialsecurity" }, { "category": "mitigation", "details": "Lack of telnet daemon authentication - Because telnet is a clear text protocol, customers are advised to be aware of corresponding risks. The telnet daemon is disabled by default in product versions WinCC flexible 2008 SP3 and newer, as well as WinCC V11 (TIA Portal) SP2 and newer. Siemens recommends disabling the telnet function on SIMATIC panels when telnet is not actively being used.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "scores": [ { "cvss_v2": { "baseScore": 9.3, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2011-4509", "cwe": { "id": "CWE-1392", "name": "Use of Default Credentials" }, "notes": [ { "category": "summary", "text": "The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account, which makes it easier for remote attackers to obtain access via a brute-force approach involving many HTTP requests.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "remediations": [ { "category": "mitigation", "details": "Each of the reported vulnerabilities has been addressed by Siemens, as follows: Insecure authentication token generation, cross-site scripting, header injection vulnerability, HMI web server directory traversal, and arbitrary memory read access vulnerabilities - Patches are included in Siemens\u2019 WinCC V11 (TIA Portal) SP2 Update 1WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112582)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112582" }, { "category": "mitigation", "details": "WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112587)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112587" }, { "category": "mitigation", "details": "and WinCC flexible 2008 SP3.WinCC flexible 2008 SP3, (http://support.automation.siemens.com/WW/view/en/57267466).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/57267466" }, { "category": "mitigation", "details": "Weak default passwords - Product documentation contained in WinCC V11 (TIA Portal) SP2 Update 1, and WinCC flexible 2008 SP3 has been updated to tell the user how to set a proper password during initial setup.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Client-side attack via specially crafted files, runtime loader string stack overflow, runtime loader directory traversal, runtime loader DoS - Siemens recommends that users deactivate the transfer mode after device configuration, because the transport mode provides full access to the device. The transport mode was implemented under the assumption that the software would be running in a protected industrial environment. Siemens strongly recommends that users protect systems according to recommended security practicesSiemens Operational Guidelines for Industrial Security, v1.1, (http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf" }, { "category": "mitigation", "details": "Siemens Industrial Security homepage, (http://www.siemens.com/industrialsecurity). and configure the environment according to the operational guidelines.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.siemens.com/industrialsecurity" }, { "category": "mitigation", "details": "Lack of telnet daemon authentication - Because telnet is a clear text protocol, customers are advised to be aware of corresponding risks. The telnet daemon is disabled by default in product versions WinCC flexible 2008 SP3 and newer, as well as WinCC V11 (TIA Portal) SP2 and newer. Siemens recommends disabling the telnet function on SIMATIC panels when telnet is not actively being used.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "scores": [ { "cvss_v2": { "baseScore": 10.0, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2011-4510", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4511.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "remediations": [ { "category": "mitigation", "details": "Each of the reported vulnerabilities has been addressed by Siemens, as follows: Insecure authentication token generation, cross-site scripting, header injection vulnerability, HMI web server directory traversal, and arbitrary memory read access vulnerabilities - Patches are included in Siemens\u2019 WinCC V11 (TIA Portal) SP2 Update 1WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112582)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112582" }, { "category": "mitigation", "details": "WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112587)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112587" }, { "category": "mitigation", "details": "and WinCC flexible 2008 SP3.WinCC flexible 2008 SP3, (http://support.automation.siemens.com/WW/view/en/57267466).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/57267466" }, { "category": "mitigation", "details": "Weak default passwords - Product documentation contained in WinCC V11 (TIA Portal) SP2 Update 1, and WinCC flexible 2008 SP3 has been updated to tell the user how to set a proper password during initial setup.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Client-side attack via specially crafted files, runtime loader string stack overflow, runtime loader directory traversal, runtime loader DoS - Siemens recommends that users deactivate the transfer mode after device configuration, because the transport mode provides full access to the device. The transport mode was implemented under the assumption that the software would be running in a protected industrial environment. Siemens strongly recommends that users protect systems according to recommended security practicesSiemens Operational Guidelines for Industrial Security, v1.1, (http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf" }, { "category": "mitigation", "details": "Siemens Industrial Security homepage, (http://www.siemens.com/industrialsecurity). and configure the environment according to the operational guidelines.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.siemens.com/industrialsecurity" }, { "category": "mitigation", "details": "Lack of telnet daemon authentication - Because telnet is a clear text protocol, customers are advised to be aware of corresponding risks. The telnet daemon is disabled by default in product versions WinCC flexible 2008 SP3 and newer, as well as WinCC V11 (TIA Portal) SP2 and newer. Siemens recommends disabling the telnet function on SIMATIC panels when telnet is not actively being used.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "scores": [ { "cvss_v2": { "baseScore": 4.3, "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2011-4511", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4510.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "remediations": [ { "category": "mitigation", "details": "Each of the reported vulnerabilities has been addressed by Siemens, as follows: Insecure authentication token generation, cross-site scripting, header injection vulnerability, HMI web server directory traversal, and arbitrary memory read access vulnerabilities - Patches are included in Siemens\u2019 WinCC V11 (TIA Portal) SP2 Update 1WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112582)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112582" }, { "category": "mitigation", "details": "WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112587)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112587" }, { "category": "mitigation", "details": "and WinCC flexible 2008 SP3.WinCC flexible 2008 SP3, (http://support.automation.siemens.com/WW/view/en/57267466).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/57267466" }, { "category": "mitigation", "details": "Weak default passwords - Product documentation contained in WinCC V11 (TIA Portal) SP2 Update 1, and WinCC flexible 2008 SP3 has been updated to tell the user how to set a proper password during initial setup.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Client-side attack via specially crafted files, runtime loader string stack overflow, runtime loader directory traversal, runtime loader DoS - Siemens recommends that users deactivate the transfer mode after device configuration, because the transport mode provides full access to the device. The transport mode was implemented under the assumption that the software would be running in a protected industrial environment. Siemens strongly recommends that users protect systems according to recommended security practicesSiemens Operational Guidelines for Industrial Security, v1.1, (http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf" }, { "category": "mitigation", "details": "Siemens Industrial Security homepage, (http://www.siemens.com/industrialsecurity). and configure the environment according to the operational guidelines.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.siemens.com/industrialsecurity" }, { "category": "mitigation", "details": "Lack of telnet daemon authentication - Because telnet is a clear text protocol, customers are advised to be aware of corresponding risks. The telnet daemon is disabled by default in product versions WinCC flexible 2008 SP3 and newer, as well as WinCC V11 (TIA Portal) SP2 and newer. Siemens recommends disabling the telnet function on SIMATIC panels when telnet is not actively being used.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "scores": [ { "cvss_v2": { "baseScore": 4.3, "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2011-4512", "cwe": { "id": "CWE-94", "name": "Improper Control of Generation of Code (\u0027Code Injection\u0027)" }, "notes": [ { "category": "summary", "text": "CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via unspecified vectors.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "remediations": [ { "category": "mitigation", "details": "Each of the reported vulnerabilities has been addressed by Siemens, as follows: Insecure authentication token generation, cross-site scripting, header injection vulnerability, HMI web server directory traversal, and arbitrary memory read access vulnerabilities - Patches are included in Siemens\u2019 WinCC V11 (TIA Portal) SP2 Update 1WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112582)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112582" }, { "category": "mitigation", "details": "WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112587)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112587" }, { "category": "mitigation", "details": "and WinCC flexible 2008 SP3.WinCC flexible 2008 SP3, (http://support.automation.siemens.com/WW/view/en/57267466).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/57267466" }, { "category": "mitigation", "details": "Weak default passwords - Product documentation contained in WinCC V11 (TIA Portal) SP2 Update 1, and WinCC flexible 2008 SP3 has been updated to tell the user how to set a proper password during initial setup.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Client-side attack via specially crafted files, runtime loader string stack overflow, runtime loader directory traversal, runtime loader DoS - Siemens recommends that users deactivate the transfer mode after device configuration, because the transport mode provides full access to the device. The transport mode was implemented under the assumption that the software would be running in a protected industrial environment. Siemens strongly recommends that users protect systems according to recommended security practicesSiemens Operational Guidelines for Industrial Security, v1.1, (http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf" }, { "category": "mitigation", "details": "Siemens Industrial Security homepage, (http://www.siemens.com/industrialsecurity). and configure the environment according to the operational guidelines.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.siemens.com/industrialsecurity" }, { "category": "mitigation", "details": "Lack of telnet daemon authentication - Because telnet is a clear text protocol, customers are advised to be aware of corresponding risks. The telnet daemon is disabled by default in product versions WinCC flexible 2008 SP3 and newer, as well as WinCC V11 (TIA Portal) SP2 and newer. Siemens recommends disabling the telnet function on SIMATIC panels when telnet is not actively being used.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "scores": [ { "cvss_v2": { "baseScore": 5.0, "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2011-4513", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file, related to the HMI web server and runtime loader.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "remediations": [ { "category": "mitigation", "details": "Each of the reported vulnerabilities has been addressed by Siemens, as follows: Insecure authentication token generation, cross-site scripting, header injection vulnerability, HMI web server directory traversal, and arbitrary memory read access vulnerabilities - Patches are included in Siemens\u2019 WinCC V11 (TIA Portal) SP2 Update 1WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112582)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112582" }, { "category": "mitigation", "details": "WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112587)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112587" }, { "category": "mitigation", "details": "and WinCC flexible 2008 SP3.WinCC flexible 2008 SP3, (http://support.automation.siemens.com/WW/view/en/57267466).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/57267466" }, { "category": "mitigation", "details": "Weak default passwords - Product documentation contained in WinCC V11 (TIA Portal) SP2 Update 1, and WinCC flexible 2008 SP3 has been updated to tell the user how to set a proper password during initial setup.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Client-side attack via specially crafted files, runtime loader string stack overflow, runtime loader directory traversal, runtime loader DoS - Siemens recommends that users deactivate the transfer mode after device configuration, because the transport mode provides full access to the device. The transport mode was implemented under the assumption that the software would be running in a protected industrial environment. Siemens strongly recommends that users protect systems according to recommended security practicesSiemens Operational Guidelines for Industrial Security, v1.1, (http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf" }, { "category": "mitigation", "details": "Siemens Industrial Security homepage, (http://www.siemens.com/industrialsecurity). and configure the environment according to the operational guidelines.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.siemens.com/industrialsecurity" }, { "category": "mitigation", "details": "Lack of telnet daemon authentication - Because telnet is a clear text protocol, customers are advised to be aware of corresponding risks. The telnet daemon is disabled by default in product versions WinCC flexible 2008 SP3 and newer, as well as WinCC V11 (TIA Portal) SP2 and newer. Siemens recommends disabling the telnet function on SIMATIC panels when telnet is not actively being used.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "scores": [ { "cvss_v2": { "baseScore": 10.0, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2011-4514", "cwe": { "id": "CWE-306", "name": "Missing Authentication for Critical Function" }, "notes": [ { "category": "summary", "text": "The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attackers to obtain access via a TCP session.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "remediations": [ { "category": "mitigation", "details": "Each of the reported vulnerabilities has been addressed by Siemens, as follows: Insecure authentication token generation, cross-site scripting, header injection vulnerability, HMI web server directory traversal, and arbitrary memory read access vulnerabilities - Patches are included in Siemens\u2019 WinCC V11 (TIA Portal) SP2 Update 1WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112582)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112582" }, { "category": "mitigation", "details": "WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112587)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112587" }, { "category": "mitigation", "details": "and WinCC flexible 2008 SP3.WinCC flexible 2008 SP3, (http://support.automation.siemens.com/WW/view/en/57267466).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/57267466" }, { "category": "mitigation", "details": "Weak default passwords - Product documentation contained in WinCC V11 (TIA Portal) SP2 Update 1, and WinCC flexible 2008 SP3 has been updated to tell the user how to set a proper password during initial setup.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Client-side attack via specially crafted files, runtime loader string stack overflow, runtime loader directory traversal, runtime loader DoS - Siemens recommends that users deactivate the transfer mode after device configuration, because the transport mode provides full access to the device. The transport mode was implemented under the assumption that the software would be running in a protected industrial environment. Siemens strongly recommends that users protect systems according to recommended security practicesSiemens Operational Guidelines for Industrial Security, v1.1, (http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf" }, { "category": "mitigation", "details": "Siemens Industrial Security homepage, (http://www.siemens.com/industrialsecurity). and configure the environment according to the operational guidelines.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.siemens.com/industrialsecurity" }, { "category": "mitigation", "details": "Lack of telnet daemon authentication - Because telnet is a clear text protocol, customers are advised to be aware of corresponding risks. The telnet daemon is disabled by default in product versions WinCC flexible 2008 SP3 and newer, as well as WinCC V11 (TIA Portal) SP2 and newer. Siemens recommends disabling the telnet function on SIMATIC panels when telnet is not actively being used.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "scores": [ { "cvss_v2": { "baseScore": 10.0, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2011-4875", "cwe": { "id": "CWE-134", "name": "Use of Externally-Controlled Format String" }, "notes": [ { "category": "summary", "text": "Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "remediations": [ { "category": "mitigation", "details": "Each of the reported vulnerabilities has been addressed by Siemens, as follows: Insecure authentication token generation, cross-site scripting, header injection vulnerability, HMI web server directory traversal, and arbitrary memory read access vulnerabilities - Patches are included in Siemens\u2019 WinCC V11 (TIA Portal) SP2 Update 1WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112582)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112582" }, { "category": "mitigation", "details": "WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112587)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112587" }, { "category": "mitigation", "details": "and WinCC flexible 2008 SP3.WinCC flexible 2008 SP3, (http://support.automation.siemens.com/WW/view/en/57267466).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/57267466" }, { "category": "mitigation", "details": "Weak default passwords - Product documentation contained in WinCC V11 (TIA Portal) SP2 Update 1, and WinCC flexible 2008 SP3 has been updated to tell the user how to set a proper password during initial setup.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Client-side attack via specially crafted files, runtime loader string stack overflow, runtime loader directory traversal, runtime loader DoS - Siemens recommends that users deactivate the transfer mode after device configuration, because the transport mode provides full access to the device. The transport mode was implemented under the assumption that the software would be running in a protected industrial environment. Siemens strongly recommends that users protect systems according to recommended security practicesSiemens Operational Guidelines for Industrial Security, v1.1, (http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf" }, { "category": "mitigation", "details": "Siemens Industrial Security homepage, (http://www.siemens.com/industrialsecurity). and configure the environment according to the operational guidelines.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.siemens.com/industrialsecurity" }, { "category": "mitigation", "details": "Lack of telnet daemon authentication - Because telnet is a clear text protocol, customers are advised to be aware of corresponding risks. The telnet daemon is disabled by default in product versions WinCC flexible 2008 SP3 and newer, as well as WinCC V11 (TIA Portal) SP2 and newer. Siemens recommends disabling the telnet function on SIMATIC panels when telnet is not actively being used.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "scores": [ { "cvss_v2": { "baseScore": 9.3, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2011-4876", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "summary", "text": "Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "remediations": [ { "category": "mitigation", "details": "Each of the reported vulnerabilities has been addressed by Siemens, as follows: Insecure authentication token generation, cross-site scripting, header injection vulnerability, HMI web server directory traversal, and arbitrary memory read access vulnerabilities - Patches are included in Siemens\u2019 WinCC V11 (TIA Portal) SP2 Update 1WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112582)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112582" }, { "category": "mitigation", "details": "WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112587)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112587" }, { "category": "mitigation", "details": "and WinCC flexible 2008 SP3.WinCC flexible 2008 SP3, (http://support.automation.siemens.com/WW/view/en/57267466).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/57267466" }, { "category": "mitigation", "details": "Weak default passwords - Product documentation contained in WinCC V11 (TIA Portal) SP2 Update 1, and WinCC flexible 2008 SP3 has been updated to tell the user how to set a proper password during initial setup.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Client-side attack via specially crafted files, runtime loader string stack overflow, runtime loader directory traversal, runtime loader DoS - Siemens recommends that users deactivate the transfer mode after device configuration, because the transport mode provides full access to the device. The transport mode was implemented under the assumption that the software would be running in a protected industrial environment. Siemens strongly recommends that users protect systems according to recommended security practicesSiemens Operational Guidelines for Industrial Security, v1.1, (http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf" }, { "category": "mitigation", "details": "Siemens Industrial Security homepage, (http://www.siemens.com/industrialsecurity). and configure the environment according to the operational guidelines.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.siemens.com/industrialsecurity" }, { "category": "mitigation", "details": "Lack of telnet daemon authentication - Because telnet is a clear text protocol, customers are advised to be aware of corresponding risks. The telnet daemon is disabled by default in product versions WinCC flexible 2008 SP3 and newer, as well as WinCC V11 (TIA Portal) SP2 and newer. Siemens recommends disabling the telnet function on SIMATIC panels when telnet is not actively being used.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "scores": [ { "cvss_v2": { "baseScore": 9.3, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2011-4877", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of service (application crash) by sending crafted data over TCP.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "remediations": [ { "category": "mitigation", "details": "Each of the reported vulnerabilities has been addressed by Siemens, as follows: Insecure authentication token generation, cross-site scripting, header injection vulnerability, HMI web server directory traversal, and arbitrary memory read access vulnerabilities - Patches are included in Siemens\u2019 WinCC V11 (TIA Portal) SP2 Update 1WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112582)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112582" }, { "category": "mitigation", "details": "WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112587)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112587" }, { "category": "mitigation", "details": "and WinCC flexible 2008 SP3.WinCC flexible 2008 SP3, (http://support.automation.siemens.com/WW/view/en/57267466).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/57267466" }, { "category": "mitigation", "details": "Weak default passwords - Product documentation contained in WinCC V11 (TIA Portal) SP2 Update 1, and WinCC flexible 2008 SP3 has been updated to tell the user how to set a proper password during initial setup.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Client-side attack via specially crafted files, runtime loader string stack overflow, runtime loader directory traversal, runtime loader DoS - Siemens recommends that users deactivate the transfer mode after device configuration, because the transport mode provides full access to the device. The transport mode was implemented under the assumption that the software would be running in a protected industrial environment. Siemens strongly recommends that users protect systems according to recommended security practicesSiemens Operational Guidelines for Industrial Security, v1.1, (http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf" }, { "category": "mitigation", "details": "Siemens Industrial Security homepage, (http://www.siemens.com/industrialsecurity). and configure the environment according to the operational guidelines.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.siemens.com/industrialsecurity" }, { "category": "mitigation", "details": "Lack of telnet daemon authentication - Because telnet is a clear text protocol, customers are advised to be aware of corresponding risks. The telnet daemon is disabled by default in product versions WinCC flexible 2008 SP3 and newer, as well as WinCC V11 (TIA Portal) SP2 and newer. Siemens recommends disabling the telnet function on SIMATIC panels when telnet is not actively being used.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "scores": [ { "cvss_v2": { "baseScore": 7.1, "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2011-4878", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "summary", "text": "Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "remediations": [ { "category": "mitigation", "details": "Each of the reported vulnerabilities has been addressed by Siemens, as follows: Insecure authentication token generation, cross-site scripting, header injection vulnerability, HMI web server directory traversal, and arbitrary memory read access vulnerabilities - Patches are included in Siemens\u2019 WinCC V11 (TIA Portal) SP2 Update 1WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112582)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112582" }, { "category": "mitigation", "details": "WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112587)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112587" }, { "category": "mitigation", "details": "and WinCC flexible 2008 SP3.WinCC flexible 2008 SP3, (http://support.automation.siemens.com/WW/view/en/57267466).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/57267466" }, { "category": "mitigation", "details": "Weak default passwords - Product documentation contained in WinCC V11 (TIA Portal) SP2 Update 1, and WinCC flexible 2008 SP3 has been updated to tell the user how to set a proper password during initial setup.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Client-side attack via specially crafted files, runtime loader string stack overflow, runtime loader directory traversal, runtime loader DoS - Siemens recommends that users deactivate the transfer mode after device configuration, because the transport mode provides full access to the device. The transport mode was implemented under the assumption that the software would be running in a protected industrial environment. Siemens strongly recommends that users protect systems according to recommended security practicesSiemens Operational Guidelines for Industrial Security, v1.1, (http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf" }, { "category": "mitigation", "details": "Siemens Industrial Security homepage, (http://www.siemens.com/industrialsecurity). and configure the environment according to the operational guidelines.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.siemens.com/industrialsecurity" }, { "category": "mitigation", "details": "Lack of telnet daemon authentication - Because telnet is a clear text protocol, customers are advised to be aware of corresponding risks. The telnet daemon is disabled by default in product versions WinCC flexible 2008 SP3 and newer, as well as WinCC V11 (TIA Portal) SP2 and newer. Siemens recommends disabling the telnet function on SIMATIC panels when telnet is not actively being used.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "scores": [ { "cvss_v2": { "baseScore": 7.8, "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2011-4879", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "remediations": [ { "category": "mitigation", "details": "Each of the reported vulnerabilities has been addressed by Siemens, as follows: Insecure authentication token generation, cross-site scripting, header injection vulnerability, HMI web server directory traversal, and arbitrary memory read access vulnerabilities - Patches are included in Siemens\u2019 WinCC V11 (TIA Portal) SP2 Update 1WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112582)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112582" }, { "category": "mitigation", "details": "WinCC V11 (TIA Portal) SP2 Update 1, (http://support.automation.siemens.com/WW/view/en/58112587)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/58112587" }, { "category": "mitigation", "details": "and WinCC flexible 2008 SP3.WinCC flexible 2008 SP3, (http://support.automation.siemens.com/WW/view/en/57267466).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://support.automation.siemens.com/WW/view/en/57267466" }, { "category": "mitigation", "details": "Weak default passwords - Product documentation contained in WinCC V11 (TIA Portal) SP2 Update 1, and WinCC flexible 2008 SP3 has been updated to tell the user how to set a proper password during initial setup.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Client-side attack via specially crafted files, runtime loader string stack overflow, runtime loader directory traversal, runtime loader DoS - Siemens recommends that users deactivate the transfer mode after device configuration, because the transport mode provides full access to the device. The transport mode was implemented under the assumption that the software would be running in a protected industrial environment. Siemens strongly recommends that users protect systems according to recommended security practicesSiemens Operational Guidelines for Industrial Security, v1.1, (http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf).", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.industry.siemens.com/topics/global/en/industrial-security/Documents/industrial_security_operational_guidelines_en.pdf" }, { "category": "mitigation", "details": "Siemens Industrial Security homepage, (http://www.siemens.com/industrialsecurity). and configure the environment according to the operational guidelines.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.siemens.com/industrialsecurity" }, { "category": "mitigation", "details": "Lack of telnet daemon authentication - Because telnet is a clear text protocol, customers are advised to be aware of corresponding risks. The telnet daemon is disabled by default in product versions WinCC flexible 2008 SP3 and newer, as well as WinCC V11 (TIA Portal) SP2 and newer. Siemens recommends disabling the telnet function on SIMATIC panels when telnet is not actively being used.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ], "scores": [ { "cvss_v2": { "baseScore": 8.5, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:C", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] } ] }
ghsa-3ppq-p8g9-x6rg
Vulnerability from github
Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string.
{ "affected": [], "aliases": [ "CVE-2011-4876" ], "database_specific": { "cwe_ids": [ "CWE-22" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2012-02-03T20:55:00Z", "severity": "HIGH" }, "details": "Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string.", "id": "GHSA-3ppq-p8g9-x6rg", "modified": "2022-05-17T01:51:17Z", "published": "2022-05-17T01:51:17Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2011-4876" }, { "type": "WEB", "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71450" }, { "type": "WEB", "url": "http://aluigi.org/adv/winccflex_1-adv.txt" }, { "type": "WEB", "url": "http://secunia.com/advisories/46997" }, { "type": "WEB", "url": "http://www.exploit-db.com/exploits/18166" }, { "type": "WEB", "url": "http://www.osvdb.org/77381" }, { "type": "WEB", "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "type": "WEB", "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf" }, { "type": "WEB", "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf" }, { "type": "WEB", "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf" } ], "schema_version": "1.4.0", "severity": [] }
fkie_cve-2011-4876
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
siemens | wincc_flexible | 2004 | |
siemens | wincc_flexible | 2005 | |
siemens | wincc_flexible | 2007 | |
siemens | wincc_flexible | 2008 | |
siemens | wincc | v11 | |
siemens | simatic_hmi_panels | comfort_panels | |
siemens | simatic_hmi_panels | mobile_panels | |
siemens | simatic_hmi_panels | mp | |
siemens | simatic_hmi_panels | op | |
siemens | simatic_hmi_panels | tp | |
siemens | wincc_runtime_advanced | v11 | |
siemens | wincc_flexible_runtime | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:wincc_flexible:2004:*:*:*:*:*:*:*", "matchCriteriaId": "7D596C29-36F8-44F2-897D-FD107769E5A9", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:wincc_flexible:2005:*:*:*:*:*:*:*", "matchCriteriaId": "2D84E29A-4BC2-4229-83C3-D9F7A641D19C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:wincc_flexible:2007:*:*:*:*:*:*:*", "matchCriteriaId": "9B3ADDE1-1F91-43E7-A3C3-3069916F4B23", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:wincc_flexible:2008:*:*:*:*:*:*:*", "matchCriteriaId": "1432EC7A-47B2-41D1-B90B-72DBB79AC266", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:wincc:v11:*:*:*:*:*:*:*", "matchCriteriaId": "18A9883B-80E1-4B2E-88DA-D2326AE3DC08", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:comfort_panels:*:*:*:*:*:*:*", "matchCriteriaId": "DC593746-B329-43EA-8CA1-AA56AC5A3B10", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:mobile_panels:*:*:*:*:*:*:*", "matchCriteriaId": "1DF877E8-A0D1-4444-99F2-8A3E8ED4D31B", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:mp:*:*:*:*:*:*:*", "matchCriteriaId": "442AC914-BDD5-4D0C-9E04-88F60EE2B730", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:op:*:*:*:*:*:*:*", "matchCriteriaId": "D9749966-1666-4F7D-90D0-17AFBB88AE83", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:tp:*:*:*:*:*:*:*", "matchCriteriaId": "9471D239-08B1-4076-82F7-2B73F4E343CE", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:wincc_runtime_advanced:v11:*:*:*:*:*:*:*", "matchCriteriaId": "1AE3AE80-C7A2-4581-993A-536936F6D315", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:wincc_flexible_runtime:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F785262-BBFB-4A0C-A7DC-97F5D6B94BB0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string." }, { "lang": "es", "value": "Vulnerabilidad de salto de directorio en HmiLoad del cargador de tiempo de ejecuci\u00f3n (\"runtime loader\") de Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; y WinCC flexible Runtime, si el modo de transferencia (\"Transfer Mode\") est\u00e1 habilitado, permite a atacantes remotos ejecutar, leer, crear, modificar o borrar archivos arbitrarios a trav\u00e9s de los caracteres .. (punto punto) en una cadena." } ], "id": "CVE-2011-4876", "lastModified": "2025-04-11T00:51:21.963", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ] }, "published": "2012-02-03T20:55:01.937", "references": [ { "source": "cret@cert.org", "url": "http://aluigi.org/adv/winccflex_1-adv.txt" }, { "source": "cret@cert.org", "url": "http://secunia.com/advisories/46997" }, { "source": "cret@cert.org", "url": "http://www.exploit-db.com/exploits/18166" }, { "source": "cret@cert.org", "url": "http://www.osvdb.org/77381" }, { "source": "cret@cert.org", "tags": [ "Vendor Advisory" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "source": "cret@cert.org", "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf" }, { "source": "cret@cert.org", "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf" }, { "source": "cret@cert.org", "tags": [ "US Government Resource" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf" }, { "source": "cret@cert.org", "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71450" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://aluigi.org/adv/winccflex_1-adv.txt" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://secunia.com/advisories/46997" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.exploit-db.com/exploits/18166" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.osvdb.org/77381" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "US Government Resource" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71450" } ], "sourceIdentifier": "cret@cert.org", "vulnStatus": "Deferred", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
gsd-2011-4876
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2011-4876", "description": "Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string.", "id": "GSD-2011-4876" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2011-4876" ], "details": "Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string.", "id": "GSD-2011-4876", "modified": "2023-12-13T01:19:05.195920Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cert@cert.org", "ID": "CVE-2011-4876", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "46997", "refsource": "SECUNIA", "url": "http://secunia.com/advisories/46997" }, { "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf", "refsource": "MISC", "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf" }, { "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf", "refsource": "MISC", "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf" }, { "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf", "refsource": "CONFIRM", "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "name": "18166", "refsource": "EXPLOIT-DB", "url": "http://www.exploit-db.com/exploits/18166" }, { "name": "http://aluigi.org/adv/winccflex_1-adv.txt", "refsource": "MISC", "url": "http://aluigi.org/adv/winccflex_1-adv.txt" }, { "name": "simatic-hmiload-dir-traversal(71450)", "refsource": "XF", "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71450" }, { "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf", "refsource": "MISC", "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf" }, { "name": "77381", "refsource": "OSVDB", "url": "http://www.osvdb.org/77381" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:wincc_flexible:2004:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:wincc_flexible:2008:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:wincc_flexible:2005:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:wincc_flexible:2007:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:wincc:v11:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:simatic_hmi_panels:tp:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:simatic_hmi_panels:op:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:simatic_hmi_panels:mobile_panels:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:simatic_hmi_panels:mp:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:simatic_hmi_panels:comfort_panels:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:wincc_runtime_advanced:v11:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:wincc_flexible_runtime:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cert@cert.org", "ID": "CVE-2011-4876" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-22" } ] } ] }, "references": { "reference_data": [ { "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf", "refsource": "CONFIRM", "tags": [ "Vendor Advisory" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf" }, { "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf", "refsource": "MISC", "tags": [ "US Government Resource" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf" }, { "name": "46997", "refsource": "SECUNIA", "tags": [], "url": "http://secunia.com/advisories/46997" }, { "name": "77381", "refsource": "OSVDB", "tags": [], "url": "http://www.osvdb.org/77381" }, { "name": "18166", "refsource": "EXPLOIT-DB", "tags": [], "url": "http://www.exploit-db.com/exploits/18166" }, { "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf", "refsource": "MISC", "tags": [], "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf" }, { "name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf", "refsource": "MISC", "tags": [], "url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf" }, { "name": "http://aluigi.org/adv/winccflex_1-adv.txt", "refsource": "MISC", "tags": [], "url": "http://aluigi.org/adv/winccflex_1-adv.txt" }, { "name": "simatic-hmiload-dir-traversal(71450)", "refsource": "XF", "tags": [], "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71450" } ] } }, "impact": { "baseMetricV2": { "cvssV2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "userInteractionRequired": false } }, "lastModifiedDate": "2017-08-29T01:30Z", "publishedDate": "2012-02-03T20:55Z" } } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.