CVE-2024-8957 (GCVE-0-2024-8957)
Vulnerability from cvelistv5
Published
2024-09-17 20:08
Modified
2025-12-27 16:47
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "pt30x-sdi_firmware",
"vendor": "ptzoptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:ptzoptics:pt30x-ndi_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "pt30x-ndi_firmware",
"vendor": "ptzoptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8957",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-08T18:25:10.384044Z",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2024-11-04",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2024-8957"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T22:55:44.249Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit",
"technical-description",
"third-party-advisory"
],
"url": "https://www.labs.greynoise.io/grimoire/2024-10-31-sift-0-day-rce/"
},
{
"url": "https://www.greynoise.io/blog/greynoise-intelligence-discovers-zero-day-vulnerabilities-in-live-streaming-cameras-with-the-help-of-ai"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2024-8957"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-11-04T00:00:00+00:00",
"value": "CVE-2024-8957 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PT30X-SDI",
"vendor": "PTZOptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PT30X-NDI",
"vendor": "PTZOptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ptzoptics:pt30x-sdi:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.3.40",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ptzoptics:pt30x-ndi-xx-g2:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.3.40",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Konstantin Lazarev of GreyNoise"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.\u003cbr\u003e"
}
],
"value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-27T16:47:39.385Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://ptzoptics.com/firmware-changelog/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://vulncheck.com/advisories/ptzoptics-command-injection"
}
],
"source": {
"discovery": "UNKNOWN"
},
"tags": [
"x_known-exploited-vulnerability"
],
"title": "PTZOptics NDI and SDI Cameras Command Injection via NTP Address Configuration",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2024-8957",
"datePublished": "2024-09-17T20:08:25.588Z",
"dateReserved": "2024-09-17T19:08:48.129Z",
"dateUpdated": "2025-12-27T16:47:39.385Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-8956 (GCVE-0-2024-8956)
Vulnerability from cvelistv5
Published
2024-09-17 19:59
Modified
2025-11-22 12:09
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-306 - Missing Authentication for Critical Function
Summary
PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "pt30x-sdi_firmware",
"vendor": "ptzoptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:ptzoptics:pt30x-ndi-xx-g2_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "pt30x-ndi-xx-g2_firmware",
"vendor": "ptzoptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8956",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-08T15:54:06.883084Z",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2024-11-04",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2024-8956"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T22:55:44.402Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"technical-description",
"third-party-advisory",
"exploit"
],
"url": "https://www.labs.greynoise.io/grimoire/2024-10-31-sift-0-day-rce/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.greynoise.io/blog/greynoise-intelligence-discovers-zero-day-vulnerabilities-in-live-streaming-cameras-with-the-help-of-ai"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2024-8956"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-11-04T00:00:00+00:00",
"value": "CVE-2024-8956 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PT30X-SDI",
"vendor": "PTZOptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PT30X-NDI",
"vendor": "PTZOptics",
"versions": [
{
"lessThan": "6.3.40",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ptzoptics:pt30x-sdi:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.3.40",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ptzoptics:pt30x-ndi-xx-g2:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.3.40",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Konstantin Lazarev of GreyNoise"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.\u003cbr\u003e"
}
],
"value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file."
}
],
"impacts": [
{
"capecId": "CAPEC-114",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-114 Authentication Abuse"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-22T12:09:58.681Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://ptzoptics.com/firmware-changelog/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://vulncheck.com/advisories/ptzoptics-insufficient-auth"
}
],
"source": {
"discovery": "UNKNOWN"
},
"tags": [
"x_known-exploited-vulnerability"
],
"title": "PTZOptics NDI and SDI Cameras /cgi-bin/param.cgi Insufficient Authentication",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2024-8956",
"datePublished": "2024-09-17T19:59:27.205Z",
"dateReserved": "2024-09-17T19:08:47.005Z",
"dateUpdated": "2025-11-22T12:09:58.681Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}