Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    4 vulnerabilities by Eluktronics

    CVE-2025-7884 (GCVE-0-2025-7884)

    Vulnerability from nvd – Published: 2025-07-20 11:02 – Updated: 2025-07-21 14:31
    VLAI
    Title
    Eluktronics Control Center REG File data authenticity
    Summary
    A vulnerability classified as problematic was found in Eluktronics Control Center 5.23.51.41. Affected by this vulnerability is an unknown functionality of the component REG File Handler. The manipulation leads to insufficient verification of data authenticity. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-345 - Insufficient Verification of Data Authenticity
    Assigner
    References
    Impacted products
    Vendor Product Version
    Eluktronics Control Center Affected: 5.23.51.41
    Create a notification for this product.
    Credits
    pipapupa (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-7884",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-21T14:31:46.276121Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-21T14:31:49.031Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://drive.proton.me/urls/5PQ1VRZ3CG#M2JyUWapaX85"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "REG File Handler"
              ],
              "product": "Control Center",
              "vendor": "Eluktronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "5.23.51.41"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "pipapupa (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability classified as problematic was found in Eluktronics Control Center 5.23.51.41. Affected by this vulnerability is an unknown functionality of the component REG File Handler. The manipulation leads to insufficient verification of data authenticity. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "In Eluktronics Control Center 5.23.51.41 wurde eine problematische Schwachstelle entdeckt. Hierbei betrifft es unbekannten Programmcode der Komponente REG File Handler. Dank Manipulation mit unbekannten Daten kann eine insufficient verification of data authenticity-Schwachstelle ausgenutzt werden. Der Angriff muss lokal angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 1.7,
                "vectorString": "AV:L/AC:L/Au:S/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-345",
                  "description": "Insufficient Verification of Data Authenticity",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-20T11:02:05.370Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-316999 | Eluktronics Control Center REG File data authenticity",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/?id.316999"
            },
            {
              "name": "VDB-316999 | CTI Indicators (IOB, IOC)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.316999"
            },
            {
              "name": "Submit #611436 | Eluktronics Control Center 5.23.51.41 Unsafe Registry Execution via Modifiable .reg Files",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.611436"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://drive.proton.me/urls/5PQ1VRZ3CG#M2JyUWapaX85"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-07-19T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-07-19T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-07-19T09:56:55.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Eluktronics Control Center REG File data authenticity"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-7884",
        "datePublished": "2025-07-20T11:02:05.370Z",
        "dateReserved": "2025-07-19T07:51:49.196Z",
        "dateUpdated": "2025-07-21T14:31:49.031Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-7883 (GCVE-0-2025-7883)

    Vulnerability from nvd – Published: 2025-07-20 10:44 – Updated: 2025-07-21 14:34
    VLAI
    Title
    Eluktronics Control Center Powershell Script Command command injection
    Summary
    A vulnerability classified as critical has been found in Eluktronics Control Center 5.23.51.41. Affected is an unknown function of the file \AiStoneService\MyControlCenter\Command of the component Powershell Script Handler. The manipulation leads to command injection. Attacking locally is a requirement. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Eluktronics Control Center Affected: 5.23.51.41
    Create a notification for this product.
    Credits
    pipapupa (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-7883",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-21T14:33:51.296072Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-21T14:34:09.407Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://drive.proton.me/urls/V5KQBBTH4G#VKpByTUTOWUW"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "Powershell Script Handler"
              ],
              "product": "Control Center",
              "vendor": "Eluktronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "5.23.51.41"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "pipapupa (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability classified as critical has been found in Eluktronics Control Center 5.23.51.41. Affected is an unknown function of the file \\AiStoneService\\MyControlCenter\\Command of the component Powershell Script Handler. The manipulation leads to command injection. Attacking locally is a requirement. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Es wurde eine kritische Schwachstelle in Eluktronics Control Center 5.23.51.41 entdeckt. Dabei betrifft es einen unbekannter Codeteil der Datei \\AiStoneService\\MyControlCenter\\Command der Komponente Powershell Script Handler. Dank der Manipulation mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff hat dabei lokal zu erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.8,
                "vectorString": "AV:L/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-20T10:44:06.279Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-316998 | Eluktronics Control Center Powershell Script Command command injection",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/?id.316998"
            },
            {
              "name": "VDB-316998 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.316998"
            },
            {
              "name": "Submit #611432 | Eluktronics Control Center 5.23.51.41 Elevation Of Privilege",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.611432"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://drive.proton.me/urls/V5KQBBTH4G#VKpByTUTOWUW"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-07-19T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-07-19T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-07-19T09:56:54.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Eluktronics Control Center Powershell Script Command command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-7883",
        "datePublished": "2025-07-20T10:44:06.279Z",
        "dateReserved": "2025-07-19T07:51:40.798Z",
        "dateUpdated": "2025-07-21T14:34:09.407Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-7884 (GCVE-0-2025-7884)

    Vulnerability from cvelistv5 – Published: 2025-07-20 11:02 – Updated: 2025-07-21 14:31
    VLAI
    Title
    Eluktronics Control Center REG File data authenticity
    Summary
    A vulnerability classified as problematic was found in Eluktronics Control Center 5.23.51.41. Affected by this vulnerability is an unknown functionality of the component REG File Handler. The manipulation leads to insufficient verification of data authenticity. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-345 - Insufficient Verification of Data Authenticity
    Assigner
    References
    Impacted products
    Vendor Product Version
    Eluktronics Control Center Affected: 5.23.51.41
    Create a notification for this product.
    Credits
    pipapupa (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-7884",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-21T14:31:46.276121Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-21T14:31:49.031Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://drive.proton.me/urls/5PQ1VRZ3CG#M2JyUWapaX85"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "REG File Handler"
              ],
              "product": "Control Center",
              "vendor": "Eluktronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "5.23.51.41"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "pipapupa (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability classified as problematic was found in Eluktronics Control Center 5.23.51.41. Affected by this vulnerability is an unknown functionality of the component REG File Handler. The manipulation leads to insufficient verification of data authenticity. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "In Eluktronics Control Center 5.23.51.41 wurde eine problematische Schwachstelle entdeckt. Hierbei betrifft es unbekannten Programmcode der Komponente REG File Handler. Dank Manipulation mit unbekannten Daten kann eine insufficient verification of data authenticity-Schwachstelle ausgenutzt werden. Der Angriff muss lokal angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 1.7,
                "vectorString": "AV:L/AC:L/Au:S/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-345",
                  "description": "Insufficient Verification of Data Authenticity",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-20T11:02:05.370Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-316999 | Eluktronics Control Center REG File data authenticity",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/?id.316999"
            },
            {
              "name": "VDB-316999 | CTI Indicators (IOB, IOC)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.316999"
            },
            {
              "name": "Submit #611436 | Eluktronics Control Center 5.23.51.41 Unsafe Registry Execution via Modifiable .reg Files",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.611436"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://drive.proton.me/urls/5PQ1VRZ3CG#M2JyUWapaX85"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-07-19T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-07-19T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-07-19T09:56:55.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Eluktronics Control Center REG File data authenticity"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-7884",
        "datePublished": "2025-07-20T11:02:05.370Z",
        "dateReserved": "2025-07-19T07:51:49.196Z",
        "dateUpdated": "2025-07-21T14:31:49.031Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-7883 (GCVE-0-2025-7883)

    Vulnerability from cvelistv5 – Published: 2025-07-20 10:44 – Updated: 2025-07-21 14:34
    VLAI
    Title
    Eluktronics Control Center Powershell Script Command command injection
    Summary
    A vulnerability classified as critical has been found in Eluktronics Control Center 5.23.51.41. Affected is an unknown function of the file \AiStoneService\MyControlCenter\Command of the component Powershell Script Handler. The manipulation leads to command injection. Attacking locally is a requirement. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Eluktronics Control Center Affected: 5.23.51.41
    Create a notification for this product.
    Credits
    pipapupa (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-7883",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-21T14:33:51.296072Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-21T14:34:09.407Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "exploit"
                ],
                "url": "https://drive.proton.me/urls/V5KQBBTH4G#VKpByTUTOWUW"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "Powershell Script Handler"
              ],
              "product": "Control Center",
              "vendor": "Eluktronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "5.23.51.41"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "pipapupa (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability classified as critical has been found in Eluktronics Control Center 5.23.51.41. Affected is an unknown function of the file \\AiStoneService\\MyControlCenter\\Command of the component Powershell Script Handler. The manipulation leads to command injection. Attacking locally is a requirement. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Es wurde eine kritische Schwachstelle in Eluktronics Control Center 5.23.51.41 entdeckt. Dabei betrifft es einen unbekannter Codeteil der Datei \\AiStoneService\\MyControlCenter\\Command der Komponente Powershell Script Handler. Dank der Manipulation mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff hat dabei lokal zu erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.8,
                "vectorString": "AV:L/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-20T10:44:06.279Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-316998 | Eluktronics Control Center Powershell Script Command command injection",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/?id.316998"
            },
            {
              "name": "VDB-316998 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.316998"
            },
            {
              "name": "Submit #611432 | Eluktronics Control Center 5.23.51.41 Elevation Of Privilege",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.611432"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://drive.proton.me/urls/V5KQBBTH4G#VKpByTUTOWUW"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-07-19T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-07-19T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-07-19T09:56:54.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Eluktronics Control Center Powershell Script Command command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-7883",
        "datePublished": "2025-07-20T10:44:06.279Z",
        "dateReserved": "2025-07-19T07:51:40.798Z",
        "dateUpdated": "2025-07-21T14:34:09.407Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }