    ICSA-26-246-02

    Vulnerability from csaf_cisa - Published: 2026-08-05 06:00 - Updated: 2026-09-03 06:00
    Summary
    IXON VPN Client
    Notes
    Legal Notice and Terms of Use: This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).
    Advisory Summary: Successful exploitation of this vulnerability could allow an attacker to perform remote code execution on the computer running the client with elevated privileges.
    Critical infrastructure sectors: Commercial Facilities, Critical Manufacturing, Energy, Information Technology, Water and Wastewater
    Countries/areas deployed: Worldwide
    Company headquarters location: Netherlands
    Recommended Practices: CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.
    Recommended Practices: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
    Recommended Practices: Locate control system networks and remote devices behind firewalls and isolating them from business networks.
    Recommended Practices: When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.
    Recommended Practices: CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
    Recommended Practices: CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
    Recommended Practices: CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
    Recommended Practices: Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
    Recommended Practices: Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
    Recommended Practices: CISA also recommends users take the following measures to protect themselves from social engineering attacks:
    Recommended Practices: Do not click web links or open attachments in unsolicited email messages.
    Recommended Practices: Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
    Recommended Practices: Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.
    Recommended Practices: No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.
    CWE-93 - Improper Neutralization of CRLF Sequences ('CRLF Injection')
    Affected products
    Product Identifier Version Remediation
    IXON VPN Client: <1.4.7
    IXON / VPN Client
    <1.4.7
    Mitigation
    Mitigation
    Mitigation
    Mitigation fix

    {
      "document": {
        "acknowledgments": [
          {
            "names": [
              "Stan van Duijnhoven",
              "Luuk van Rheden"
            ],
            "organization": "IXON",
            "summary": "reported this vulnerability to CISA"
          }
        ],
        "category": "csaf_security_advisory",
        "csaf_version": "2.0",
        "distribution": {
          "text": "Disclosure is not limited",
          "tlp": {
            "label": "WHITE",
            "url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
          }
        },
        "lang": "en-US",
        "notes": [
          {
            "category": "legal_disclaimer",
            "text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
            "title": "Legal Notice and Terms of Use"
          },
          {
            "category": "summary",
            "text": "Successful exploitation of this vulnerability could allow an attacker to perform remote code execution on the computer running the client with elevated privileges. ",
            "title": "Advisory Summary"
          },
          {
            "category": "other",
            "text": "Commercial Facilities, Critical Manufacturing, Energy, Information Technology, Water and Wastewater",
            "title": "Critical infrastructure sectors"
          },
          {
            "category": "other",
            "text": "Worldwide",
            "title": "Countries/areas deployed"
          },
          {
            "category": "other",
            "text": "Netherlands",
            "title": "Company headquarters location"
          },
          {
            "category": "general",
            "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability.",
            "title": "Recommended Practices"
          },
          {
            "category": "general",
            "text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.",
            "title": "Recommended Practices"
          },
          {
            "category": "general",
            "text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.",
            "title": "Recommended Practices"
          },
          {
            "category": "general",
            "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.",
            "title": "Recommended Practices"
          },
          {
            "category": "general",
            "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
            "title": "Recommended Practices"
          },
          {
            "category": "general",
            "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
            "title": "Recommended Practices"
          },
          {
            "category": "general",
            "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
            "title": "Recommended Practices"
          },
          {
            "category": "general",
            "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
            "title": "Recommended Practices"
          },
          {
            "category": "general",
            "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
            "title": "Recommended Practices"
          },
          {
            "category": "general",
            "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:",
            "title": "Recommended Practices"
          },
          {
            "category": "general",
            "text": "Do not click web links or open attachments in unsolicited email messages.",
            "title": "Recommended Practices"
          },
          {
            "category": "general",
            "text": "Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.",
            "title": "Recommended Practices"
          },
          {
            "category": "general",
            "text": "Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.",
            "title": "Recommended Practices"
          },
          {
            "category": "general",
            "text": "No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.",
            "title": "Recommended Practices"
          }
        ],
        "publisher": {
          "category": "coordinator",
          "contact_details": "central@cisa.dhs.gov",
          "name": "CISA",
          "namespace": "https://www.cisa.gov/"
        },
        "references": [
          {
            "category": "self",
            "summary": "ICS Advisory ICSA-26-246-02 JSON",
            "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-246-02.json"
          },
          {
            "category": "self",
            "summary": "ICSA Advisory ICSA-26-246-02 - Web Version",
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-246-02"
          },
          {
            "category": "external",
            "summary": "Recommended Practices",
            "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
          },
          {
            "category": "external",
            "summary": "Recommended Practices",
            "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
          },
          {
            "category": "external",
            "summary": "Recommended Practices",
            "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
          },
          {
            "category": "external",
            "summary": "Recommended Practices",
            "url": "https://www.cisa.gov/topics/industrial-control-systems"
          },
          {
            "category": "external",
            "summary": "Recommended Practices",
            "url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf"
          },
          {
            "category": "external",
            "summary": "Recommended Practices",
            "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014"
          },
          {
            "category": "external",
            "summary": "Recommended Practices",
            "url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
          },
          {
            "category": "external",
            "summary": "Recommended Practices",
            "url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
          },
          {
            "category": "external",
            "summary": "Recommended Practices",
            "url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
          },
          {
            "category": "external",
            "summary": "Recommended Practices",
            "url": "https://www.cisa.gov/secure-our-world/teach-employees-avoid-phishing"
          },
          {
            "category": "external",
            "summary": "Recommended Practices",
            "url": "https://www.cisa.gov/news-events/news/avoiding-social-engineering-and-phishing-attacks"
          }
        ],
        "title": "IXON VPN Client",
        "tracking": {
          "current_release_date": "2026-09-03T06:00:00.000000Z",
          "generator": {
            "date": "2026-09-02T19:25:31.843512Z",
            "engine": {
              "name": "CISA CSAF Generator",
              "version": "1.0.0"
            }
          },
          "id": "ICSA-26-246-02",
          "initial_release_date": "2026-08-05T06:00:00.000000Z",
          "revision_history": [
            {
              "date": "2026-08-05T06:00:00.000000Z",
              "legacy_version": "Initial",
              "number": "1",
              "summary": "Initial Publication"
            },
            {
              "date": "2026-09-03T06:00:00.000000Z",
              "legacy_version": "Initial Republication by CISA",
              "number": "2",
              "summary": "Initial Republication by CISA"
            }
          ],
          "status": "final",
          "version": "2"
        }
      },
      "product_tree": {
        "branches": [
          {
            "branches": [
              {
                "branches": [
                  {
                    "category": "product_version_range",
                    "name": "\u003c1.4.7",
                    "product": {
                      "name": "IXON VPN Client: \u003c1.4.7",
                      "product_id": "CSAFPID-0001"
                    }
                  }
                ],
                "category": "product_name",
                "name": "VPN Client"
              }
            ],
            "category": "vendor",
            "name": "IXON"
          }
        ]
      },
      "vulnerabilities": [
        {
          "cve": "CVE-2026-75925",
          "cwe": {
            "id": "CWE-93",
            "name": "Improper Neutralization of CRLF Sequences (\u0027CRLF Injection\u0027)"
          },
          "notes": [
            {
              "category": "summary",
              "text": "Improper Neutralization of CRLF Sequences (CWE-93) in IXON VPN Client before version 1.4.7 allows an attacker to execute commands as root or SYSTEM. Configuration values accepted by the local service are written to a file later consumed by a privileged subprocess, without line-ending sequences being neutralised, which allows additional directives to be introduced into that file. The configuration interface accepts changes without authenticating or verifying the origin of the requester (CWE-306, contributing). The injected configuration persists on disk across restarts of the client and the operating system, and the VPN connection continues to function normally, so there is no behavioral change visible to the user.",
              "title": "Vulnerability Summary"
            },
            {
              "category": "details",
              "text": "SSVCv2/E:N/A:Y/2026-09-02T06:00:00.000000Z",
              "title": "SSVC"
            }
          ],
          "product_status": {
            "known_affected": [
              "CSAFPID-0001"
            ]
          },
          "references": [
            {
              "category": "external",
              "summary": "cwe.mitre.org",
              "url": "https://cwe.mitre.org/data/definitions/93.html"
            },
            {
              "category": "external",
              "summary": "www.cve.org",
              "url": "https://www.cve.org/CVERecord?id=CVE-2026-75925"
            },
            {
              "category": "external",
              "summary": "www.first.org",
              "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H"
            },
            {
              "category": "external",
              "summary": "www.first.org",
              "url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H"
            }
          ],
          "remediations": [
            {
              "category": "mitigation",
              "details": "IXON recommends updating the IXON VPN client to version 1.4.7 or later on every computer where it is installed.",
              "product_ids": [
                "CSAFPID-0001"
              ]
            },
            {
              "category": "mitigation",
              "details": "As of August 5, 2026, IXON cloud rejects connections from clients below v1.4.7 at both the portal and the back-end API. Since the privileged subprocess and injected listener are only created when the client connects, unpatched installations cannot complete the exploit chain.",
              "product_ids": [
                "CSAFPID-0001"
              ]
            },
            {
              "category": "mitigation",
              "details": "If the client is no longer needed, IXON recommends uninstalling the VPN client from the computer.",
              "product_ids": [
                "CSAFPID-0001"
              ]
            },
            {
              "category": "mitigation",
              "details": "For more information please refer to the IXON Trust Center Advisory at https://www.ixon.cloud/Advisories/ADV-2026-08-05.pdf.",
              "product_ids": [
                "CSAFPID-0001"
              ],
              "url": "https://www.ixon.cloud/Advisories/ADV-2026-08-05.pdf%60"
            }
          ],
          "scores": [
            {
              "cvss_v3": {
                "baseScore": 9.6,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "products": [
                "CSAFPID-0001"
              ]
            }
          ]
        }
      ]
    }