CVE-2025-10151 (GCVE-0-2025-10151)
Vulnerability from nvd
Published
2025-10-28 07:25
Modified
2025-10-28 13:27
CWE
Summary
Improper locking vulnerability in Softing Industrial Automation GmbH gateways allows infected memory and/or resource leak exposure.This issue affects smartLink HW-PN: from 1.02 through 1.03 smartLink HW-DP: 1.31
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-10151",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-28T13:23:50.979355Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-28T13:27:14.343Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "smartLink HW-PN",
          "vendor": "Softing Industrial Automation GmbH",
          "versions": [
            {
              "lessThanOrEqual": "1.03",
              "status": "affected",
              "version": "1.02",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "smartLink HW-DP",
          "vendor": "Softing Industrial Automation GmbH",
          "versions": [
            {
              "lessThanOrEqual": "1.31",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper locking vulnerability in Softing Industrial Automation GmbH gateways allows infected memory and/or resource leak exposure.\u003cp\u003eThis issue affects\u003c/p\u003e\u003cp\u003esmartLink HW-PN: from 1.02 through 1.03\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.31\u003c/p\u003e"
            }
          ],
          "value": "Improper locking vulnerability in Softing Industrial Automation GmbH gateways allows infected memory and/or resource leak exposure.This issue affects\n\nsmartLink HW-PN: from 1.02 through 1.03\n\nsmartLink HW-DP: 1.31"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-456",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-456 Infected Memory"
            }
          ]
        },
        {
          "capecId": "CAPEC-131",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-131 Resource Leak Exposure"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "YES",
            "Recovery": "USER",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "AMBER",
            "subAvailabilityImpact": "LOW",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "LOW",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:H/SI:L/SA:L/AU:Y/R:U/RE:M/U:Amber",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "MODERATE"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-667",
              "description": "CWE-667 Improper Locking",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-28T07:25:39.639Z",
        "orgId": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
        "shortName": "Softing"
      },
      "references": [
        {
          "tags": [
            "x_html"
          ],
          "url": "https://https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10151.html"
        },
        {
          "tags": [
            "x_json"
          ],
          "url": "https://https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10151.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eThis issue is fixed in\u003c/p\u003e\u003cp\u003esmartLink HW-PN: 1.04\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.32\u003c/p\u003e"
            }
          ],
          "value": "This issue is fixed in\n\nsmartLink HW-PN: 1.04\n\nsmartLink HW-DP: 1.32"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Malicious TCP/IP thread locking leads into diverse malfunctions",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
    "assignerShortName": "Softing",
    "cveId": "CVE-2025-10151",
    "datePublished": "2025-10-28T07:25:39.639Z",
    "dateReserved": "2025-09-09T07:27:10.152Z",
    "dateUpdated": "2025-10-28T13:27:14.343Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-10150 (GCVE-0-2025-10150)
Vulnerability from nvd
Published
2025-10-28 07:24
Modified
2025-10-28 13:28
CWE
Summary
Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.This issue affects smartLink HW-PN: from 1.02 through 1.03 smartLink HW-DP: 1.31
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-10150",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-28T13:27:44.147539Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-28T13:28:01.850Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "smartLink HW-PN",
          "vendor": "Softing Industrial Automation GmbH",
          "versions": [
            {
              "lessThanOrEqual": "1.03",
              "status": "affected",
              "version": "1.02",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "smartLink HW-DP",
          "vendor": "Softing Industrial Automation GmbH",
          "versions": [
            {
              "lessThanOrEqual": "1.31",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:softing_industrial_automation_gmbh:smartlink_hw-pn:*:*:*:*:*:*:*:*",
                  "versionEndIncluding": "1.03",
                  "versionStartIncluding": "1.02",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:softing_industrial_automation_gmbh:smartlink_hw-dp:*:*:*:*:*:*:*:*",
                  "versionEndIncluding": "1.31",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.\u003cp\u003eThis issue affects\u003c/p\u003e\u003cp\u003esmartLink HW-PN: from 1.02 through 1.03\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.31\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.This issue affects\n\nsmartLink HW-PN: from 1.02 through 1.03\n\nsmartLink HW-DP: 1.31"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-25",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-25 Forced Deadlock"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "YES",
            "Recovery": "USER",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "AMBER",
            "subAvailabilityImpact": "LOW",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/AU:Y/R:U/RE:M/U:Amber",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "MODERATE"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-833",
              "description": "CWE-833: Deadlock",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-28T07:24:38.296Z",
        "orgId": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
        "shortName": "Softing"
      },
      "references": [
        {
          "tags": [
            "x_html"
          ],
          "url": "https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10150.html"
        },
        {
          "tags": [
            "x_json"
          ],
          "url": "https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10150.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eThis issue is fixed in\u003c/p\u003e\u003cp\u003esmartLink HW-PN: 1.04\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.32\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "This issue is fixed in\n\nsmartLink HW-PN: 1.04\n\nsmartLink HW-DP: 1.32"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Webserver crash caused by scanning on TCP port 80",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
    "assignerShortName": "Softing",
    "cveId": "CVE-2025-10150",
    "datePublished": "2025-10-28T07:24:38.296Z",
    "dateReserved": "2025-09-09T07:27:03.262Z",
    "dateUpdated": "2025-10-28T13:28:01.850Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-10151 (GCVE-0-2025-10151)
Vulnerability from cvelistv5
Published
2025-10-28 07:25
Modified
2025-10-28 13:27
CWE
Summary
Improper locking vulnerability in Softing Industrial Automation GmbH gateways allows infected memory and/or resource leak exposure.This issue affects smartLink HW-PN: from 1.02 through 1.03 smartLink HW-DP: 1.31
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-10151",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-28T13:23:50.979355Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-28T13:27:14.343Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "smartLink HW-PN",
          "vendor": "Softing Industrial Automation GmbH",
          "versions": [
            {
              "lessThanOrEqual": "1.03",
              "status": "affected",
              "version": "1.02",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "smartLink HW-DP",
          "vendor": "Softing Industrial Automation GmbH",
          "versions": [
            {
              "lessThanOrEqual": "1.31",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper locking vulnerability in Softing Industrial Automation GmbH gateways allows infected memory and/or resource leak exposure.\u003cp\u003eThis issue affects\u003c/p\u003e\u003cp\u003esmartLink HW-PN: from 1.02 through 1.03\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.31\u003c/p\u003e"
            }
          ],
          "value": "Improper locking vulnerability in Softing Industrial Automation GmbH gateways allows infected memory and/or resource leak exposure.This issue affects\n\nsmartLink HW-PN: from 1.02 through 1.03\n\nsmartLink HW-DP: 1.31"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-456",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-456 Infected Memory"
            }
          ]
        },
        {
          "capecId": "CAPEC-131",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-131 Resource Leak Exposure"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "YES",
            "Recovery": "USER",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "AMBER",
            "subAvailabilityImpact": "LOW",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "LOW",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:H/SI:L/SA:L/AU:Y/R:U/RE:M/U:Amber",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "MODERATE"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-667",
              "description": "CWE-667 Improper Locking",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-28T07:25:39.639Z",
        "orgId": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
        "shortName": "Softing"
      },
      "references": [
        {
          "tags": [
            "x_html"
          ],
          "url": "https://https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10151.html"
        },
        {
          "tags": [
            "x_json"
          ],
          "url": "https://https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10151.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eThis issue is fixed in\u003c/p\u003e\u003cp\u003esmartLink HW-PN: 1.04\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.32\u003c/p\u003e"
            }
          ],
          "value": "This issue is fixed in\n\nsmartLink HW-PN: 1.04\n\nsmartLink HW-DP: 1.32"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Malicious TCP/IP thread locking leads into diverse malfunctions",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
    "assignerShortName": "Softing",
    "cveId": "CVE-2025-10151",
    "datePublished": "2025-10-28T07:25:39.639Z",
    "dateReserved": "2025-09-09T07:27:10.152Z",
    "dateUpdated": "2025-10-28T13:27:14.343Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-10150 (GCVE-0-2025-10150)
Vulnerability from cvelistv5
Published
2025-10-28 07:24
Modified
2025-10-28 13:28
CWE
Summary
Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.This issue affects smartLink HW-PN: from 1.02 through 1.03 smartLink HW-DP: 1.31
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-10150",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-28T13:27:44.147539Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-28T13:28:01.850Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "smartLink HW-PN",
          "vendor": "Softing Industrial Automation GmbH",
          "versions": [
            {
              "lessThanOrEqual": "1.03",
              "status": "affected",
              "version": "1.02",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "smartLink HW-DP",
          "vendor": "Softing Industrial Automation GmbH",
          "versions": [
            {
              "lessThanOrEqual": "1.31",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:softing_industrial_automation_gmbh:smartlink_hw-pn:*:*:*:*:*:*:*:*",
                  "versionEndIncluding": "1.03",
                  "versionStartIncluding": "1.02",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:softing_industrial_automation_gmbh:smartlink_hw-dp:*:*:*:*:*:*:*:*",
                  "versionEndIncluding": "1.31",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.\u003cp\u003eThis issue affects\u003c/p\u003e\u003cp\u003esmartLink HW-PN: from 1.02 through 1.03\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.31\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.This issue affects\n\nsmartLink HW-PN: from 1.02 through 1.03\n\nsmartLink HW-DP: 1.31"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-25",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-25 Forced Deadlock"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "YES",
            "Recovery": "USER",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "AMBER",
            "subAvailabilityImpact": "LOW",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/AU:Y/R:U/RE:M/U:Amber",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "MODERATE"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-833",
              "description": "CWE-833: Deadlock",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-28T07:24:38.296Z",
        "orgId": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
        "shortName": "Softing"
      },
      "references": [
        {
          "tags": [
            "x_html"
          ],
          "url": "https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10150.html"
        },
        {
          "tags": [
            "x_json"
          ],
          "url": "https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10150.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eThis issue is fixed in\u003c/p\u003e\u003cp\u003esmartLink HW-PN: 1.04\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.32\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "This issue is fixed in\n\nsmartLink HW-PN: 1.04\n\nsmartLink HW-DP: 1.32"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Webserver crash caused by scanning on TCP port 80",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
    "assignerShortName": "Softing",
    "cveId": "CVE-2025-10150",
    "datePublished": "2025-10-28T07:24:38.296Z",
    "dateReserved": "2025-09-09T07:27:03.262Z",
    "dateUpdated": "2025-10-28T13:28:01.850Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}