Refine your search
4 vulnerabilities found for smartLink HW-DP by Softing Industrial Automation GmbH
CVE-2025-10151 (GCVE-0-2025-10151)
Vulnerability from nvd
Published
2025-10-28 07:25
Modified
2025-10-28 13:27
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-667 - Improper Locking
Summary
Improper locking vulnerability in Softing Industrial Automation GmbH gateways allows infected memory and/or resource leak exposure.This issue affects
smartLink HW-PN: from 1.02 through 1.03
smartLink HW-DP: 1.31
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Softing Industrial Automation GmbH | smartLink HW-PN |
Version: 1.02 < |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-10151",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-28T13:23:50.979355Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T13:27:14.343Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "smartLink HW-PN",
"vendor": "Softing Industrial Automation GmbH",
"versions": [
{
"lessThanOrEqual": "1.03",
"status": "affected",
"version": "1.02",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "smartLink HW-DP",
"vendor": "Softing Industrial Automation GmbH",
"versions": [
{
"lessThanOrEqual": "1.31",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper locking vulnerability in Softing Industrial Automation GmbH gateways allows infected memory and/or resource leak exposure.\u003cp\u003eThis issue affects\u003c/p\u003e\u003cp\u003esmartLink HW-PN: from 1.02 through 1.03\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.31\u003c/p\u003e"
}
],
"value": "Improper locking vulnerability in Softing Industrial Automation GmbH gateways allows infected memory and/or resource leak exposure.This issue affects\n\nsmartLink HW-PN: from 1.02 through 1.03\n\nsmartLink HW-DP: 1.31"
}
],
"impacts": [
{
"capecId": "CAPEC-456",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-456 Infected Memory"
}
]
},
{
"capecId": "CAPEC-131",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-131 Resource Leak Exposure"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "USER",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "AMBER",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:H/SI:L/SA:L/AU:Y/R:U/RE:M/U:Amber",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "MODERATE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-667",
"description": "CWE-667 Improper Locking",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T07:25:39.639Z",
"orgId": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
"shortName": "Softing"
},
"references": [
{
"tags": [
"x_html"
],
"url": "https://https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10151.html"
},
{
"tags": [
"x_json"
],
"url": "https://https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10151.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThis issue is fixed in\u003c/p\u003e\u003cp\u003esmartLink HW-PN: 1.04\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.32\u003c/p\u003e"
}
],
"value": "This issue is fixed in\n\nsmartLink HW-PN: 1.04\n\nsmartLink HW-DP: 1.32"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Malicious TCP/IP thread locking leads into diverse malfunctions",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
"assignerShortName": "Softing",
"cveId": "CVE-2025-10151",
"datePublished": "2025-10-28T07:25:39.639Z",
"dateReserved": "2025-09-09T07:27:10.152Z",
"dateUpdated": "2025-10-28T13:27:14.343Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-10150 (GCVE-0-2025-10150)
Vulnerability from nvd
Published
2025-10-28 07:24
Modified
2025-10-28 13:28
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-833 - Deadlock
Summary
Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.This issue affects
smartLink HW-PN: from 1.02 through 1.03
smartLink HW-DP: 1.31
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Softing Industrial Automation GmbH | smartLink HW-PN |
Version: 1.02 < |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-10150",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-28T13:27:44.147539Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T13:28:01.850Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "smartLink HW-PN",
"vendor": "Softing Industrial Automation GmbH",
"versions": [
{
"lessThanOrEqual": "1.03",
"status": "affected",
"version": "1.02",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "smartLink HW-DP",
"vendor": "Softing Industrial Automation GmbH",
"versions": [
{
"lessThanOrEqual": "1.31",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:softing_industrial_automation_gmbh:smartlink_hw-pn:*:*:*:*:*:*:*:*",
"versionEndIncluding": "1.03",
"versionStartIncluding": "1.02",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:softing_industrial_automation_gmbh:smartlink_hw-dp:*:*:*:*:*:*:*:*",
"versionEndIncluding": "1.31",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.\u003cp\u003eThis issue affects\u003c/p\u003e\u003cp\u003esmartLink HW-PN: from 1.02 through 1.03\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.31\u003cbr\u003e\u003c/p\u003e"
}
],
"value": "Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.This issue affects\n\nsmartLink HW-PN: from 1.02 through 1.03\n\nsmartLink HW-DP: 1.31"
}
],
"impacts": [
{
"capecId": "CAPEC-25",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-25 Forced Deadlock"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "USER",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "AMBER",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/AU:Y/R:U/RE:M/U:Amber",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "MODERATE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-833",
"description": "CWE-833: Deadlock",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T07:24:38.296Z",
"orgId": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
"shortName": "Softing"
},
"references": [
{
"tags": [
"x_html"
],
"url": "https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10150.html"
},
{
"tags": [
"x_json"
],
"url": "https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10150.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThis issue is fixed in\u003c/p\u003e\u003cp\u003esmartLink HW-PN: 1.04\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.32\u003cbr\u003e\u003c/p\u003e"
}
],
"value": "This issue is fixed in\n\nsmartLink HW-PN: 1.04\n\nsmartLink HW-DP: 1.32"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Webserver crash caused by scanning on TCP port 80",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
"assignerShortName": "Softing",
"cveId": "CVE-2025-10150",
"datePublished": "2025-10-28T07:24:38.296Z",
"dateReserved": "2025-09-09T07:27:03.262Z",
"dateUpdated": "2025-10-28T13:28:01.850Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-10151 (GCVE-0-2025-10151)
Vulnerability from cvelistv5
Published
2025-10-28 07:25
Modified
2025-10-28 13:27
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-667 - Improper Locking
Summary
Improper locking vulnerability in Softing Industrial Automation GmbH gateways allows infected memory and/or resource leak exposure.This issue affects
smartLink HW-PN: from 1.02 through 1.03
smartLink HW-DP: 1.31
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Softing Industrial Automation GmbH | smartLink HW-PN |
Version: 1.02 < |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-10151",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-28T13:23:50.979355Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T13:27:14.343Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "smartLink HW-PN",
"vendor": "Softing Industrial Automation GmbH",
"versions": [
{
"lessThanOrEqual": "1.03",
"status": "affected",
"version": "1.02",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "smartLink HW-DP",
"vendor": "Softing Industrial Automation GmbH",
"versions": [
{
"lessThanOrEqual": "1.31",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper locking vulnerability in Softing Industrial Automation GmbH gateways allows infected memory and/or resource leak exposure.\u003cp\u003eThis issue affects\u003c/p\u003e\u003cp\u003esmartLink HW-PN: from 1.02 through 1.03\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.31\u003c/p\u003e"
}
],
"value": "Improper locking vulnerability in Softing Industrial Automation GmbH gateways allows infected memory and/or resource leak exposure.This issue affects\n\nsmartLink HW-PN: from 1.02 through 1.03\n\nsmartLink HW-DP: 1.31"
}
],
"impacts": [
{
"capecId": "CAPEC-456",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-456 Infected Memory"
}
]
},
{
"capecId": "CAPEC-131",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-131 Resource Leak Exposure"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "USER",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "AMBER",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:L/SC:H/SI:L/SA:L/AU:Y/R:U/RE:M/U:Amber",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "MODERATE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-667",
"description": "CWE-667 Improper Locking",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T07:25:39.639Z",
"orgId": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
"shortName": "Softing"
},
"references": [
{
"tags": [
"x_html"
],
"url": "https://https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10151.html"
},
{
"tags": [
"x_json"
],
"url": "https://https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10151.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThis issue is fixed in\u003c/p\u003e\u003cp\u003esmartLink HW-PN: 1.04\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.32\u003c/p\u003e"
}
],
"value": "This issue is fixed in\n\nsmartLink HW-PN: 1.04\n\nsmartLink HW-DP: 1.32"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Malicious TCP/IP thread locking leads into diverse malfunctions",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
"assignerShortName": "Softing",
"cveId": "CVE-2025-10151",
"datePublished": "2025-10-28T07:25:39.639Z",
"dateReserved": "2025-09-09T07:27:10.152Z",
"dateUpdated": "2025-10-28T13:27:14.343Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-10150 (GCVE-0-2025-10150)
Vulnerability from cvelistv5
Published
2025-10-28 07:24
Modified
2025-10-28 13:28
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-833 - Deadlock
Summary
Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.This issue affects
smartLink HW-PN: from 1.02 through 1.03
smartLink HW-DP: 1.31
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Softing Industrial Automation GmbH | smartLink HW-PN |
Version: 1.02 < |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-10150",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-28T13:27:44.147539Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T13:28:01.850Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "smartLink HW-PN",
"vendor": "Softing Industrial Automation GmbH",
"versions": [
{
"lessThanOrEqual": "1.03",
"status": "affected",
"version": "1.02",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "smartLink HW-DP",
"vendor": "Softing Industrial Automation GmbH",
"versions": [
{
"lessThanOrEqual": "1.31",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:softing_industrial_automation_gmbh:smartlink_hw-pn:*:*:*:*:*:*:*:*",
"versionEndIncluding": "1.03",
"versionStartIncluding": "1.02",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:softing_industrial_automation_gmbh:smartlink_hw-dp:*:*:*:*:*:*:*:*",
"versionEndIncluding": "1.31",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.\u003cp\u003eThis issue affects\u003c/p\u003e\u003cp\u003esmartLink HW-PN: from 1.02 through 1.03\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.31\u003cbr\u003e\u003c/p\u003e"
}
],
"value": "Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.This issue affects\n\nsmartLink HW-PN: from 1.02 through 1.03\n\nsmartLink HW-DP: 1.31"
}
],
"impacts": [
{
"capecId": "CAPEC-25",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-25 Forced Deadlock"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "USER",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "AMBER",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/AU:Y/R:U/RE:M/U:Amber",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "MODERATE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-833",
"description": "CWE-833: Deadlock",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T07:24:38.296Z",
"orgId": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
"shortName": "Softing"
},
"references": [
{
"tags": [
"x_html"
],
"url": "https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10150.html"
},
{
"tags": [
"x_json"
],
"url": "https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10150.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThis issue is fixed in\u003c/p\u003e\u003cp\u003esmartLink HW-PN: 1.04\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.32\u003cbr\u003e\u003c/p\u003e"
}
],
"value": "This issue is fixed in\n\nsmartLink HW-PN: 1.04\n\nsmartLink HW-DP: 1.32"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Webserver crash caused by scanning on TCP port 80",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
"assignerShortName": "Softing",
"cveId": "CVE-2025-10150",
"datePublished": "2025-10-28T07:24:38.296Z",
"dateReserved": "2025-09-09T07:27:03.262Z",
"dateUpdated": "2025-10-28T13:28:01.850Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}