Vulnerabilites related to vivo - Wifi
CVE-2021-26278 (GCVE-0-2021-26278)
Vulnerability from cvelistv5
Published
2024-12-17 03:05
Modified
2024-12-17 17:30
CWE
  • CWE-306 - Missing Authentication for Critical Function
Summary
The wifi module exposes the interface and has improper permission control, leaking sensitive information about the device.
Impacted products
Vendor Product Version
vivo Wifi Version: Versions earlier than Android 10
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-26278",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-17T15:25:19.006568Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-17T17:30:08.414Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Wifi",
          "vendor": "vivo",
          "versions": [
            {
              "status": "affected",
              "version": "Versions earlier than Android 10"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The wifi module exposes the interface and has improper permission control, leaking sensitive information about the device.\u003cbr\u003e"
            }
          ],
          "value": "The wifi module exposes the interface and has improper permission control, leaking sensitive information about the device."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-17T03:05:03.842Z",
        "orgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
        "shortName": "Vivo"
      },
      "references": [
        {
          "url": "https://www.vivo.com/en/support/security-advisory-detail?id=7"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Sensitive information leakage vulnerability in wifi module",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
    "assignerShortName": "Vivo",
    "cveId": "CVE-2021-26278",
    "datePublished": "2024-12-17T03:05:03.842Z",
    "dateReserved": "2021-01-27T19:41:45.352Z",
    "dateUpdated": "2024-12-17T17:30:08.414Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-12484 (GCVE-0-2020-12484)
Vulnerability from cvelistv5
Published
2024-12-17 02:36
Modified
2024-12-17 14:54
CWE
  • CWE-306 - Missing Authentication for Critical Function
Summary
When using special mode to connect to enterprise wifi, certain options are not properly configured and attackers can pretend to be enterprise wifi through a carefully constructed wifi with the same name, which can lead to man-in-the-middle attacks.
Impacted products
Vendor Product Version
vivo Wifi Version: Versions earlier than 8.12.0.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-12484",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-17T14:54:11.114793Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-17T14:54:21.557Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Wifi",
          "vendor": "vivo",
          "versions": [
            {
              "status": "affected",
              "version": "Versions earlier than 8.12.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "When using special mode to connect to enterprise wifi, certain options are not properly configured and attackers can pretend to be enterprise wifi through a carefully constructed wifi with the same name, which can lead to man-in-the-middle attacks.\u003cbr\u003e"
            }
          ],
          "value": "When using special mode to connect to enterprise wifi, certain options are not properly configured and attackers can pretend to be enterprise wifi through a carefully constructed wifi with the same name, which can lead to man-in-the-middle attacks."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-151",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-151 Identity Spoofing"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-17T02:36:45.758Z",
        "orgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
        "shortName": "Vivo"
      },
      "references": [
        {
          "url": "https://www.vivo.com/en/support/security-advisory-detail?id=3"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c6f5cd8e-fe3d-4460-82c2-f8a4e7b272c8",
    "assignerShortName": "Vivo",
    "cveId": "CVE-2020-12484",
    "datePublished": "2024-12-17T02:36:45.758Z",
    "dateReserved": "2020-04-30T00:00:00.000Z",
    "dateUpdated": "2024-12-17T14:54:21.557Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}